919 resultados para Postoperative complication


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND After general surgery, the lower limb experiences some of the highest complication rates. However, little is known about contributing factors to surgical site failure in the lower limb dermatological surgery population. OBJECTIVE To determine the incidence of lower limb surgical site failure and to explore the predictors that contribute to surgical site failure. METHODS A prospective observational study design was used to collect data from 73 participants, from July 2010, to March 2012. Incidence was determined as a percentage of surgical site failure from the total population. Predictors were determined by the use of a binary logistic regression model. RESULTS The surgical site failure rate was 53.4%. Split-skin grafting had a higher failure rate than primary closures, 66% versus 26.1%. Predictors of lower limb surgical site failure were identified as increasing age (p = .04) and the presence of postoperative hematoma (p = .01), with all patients who developed surgical site infection experiencing surgical site failure (p = .01). CONCLUSION Findings from this study confirmed that the lower limb is at high risk of surgical site failure. Two predictors of surgical site failure from this cohort were determined. However, to understand this phenomenon and make recommendations to assist and reduce surgical site complications, further research in this field is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orthotopic liver transplantation began in Brisbane in January 1985. During the first two years of the programme an assessment committee evaluated 55 patients (38 adults, 17 children). Patients were either accepted for transplantation, rejected as unsuitable or deferred for elective reassessment. All of the 10 adults who were rejected for transplantation because they had 'too advanced' disease died within four months of assessment. Six children who were accepted for transplantation died before a suitable donor liver could be found. In the first two years, 21 orthotopic liver transplantations were performed on 18 patients (adults, 13 patients; children, five patients). Fifteen of 21 grafts were procured from within Queensland. Twelve (67%) patients are alive at three to 23 months and all have been discharged from hospital. Deaths in adults were due to sepsis (three patients), aspiration pneumonitis (one patient), rejection and hepatic artery thrombosis (one patient) and the recurrence of a hepatocellular carcinoma five months after discharge from hospital (one patient). Two patients underwent a second transplantation procedure because of chronic rejection at four months and at 11 months, respectively, after the initial operation. One patient received a second transplant for primary graft failure at four days after the operation. A scoring system which considered the presence of pre-operative patient factors, such as coma, ascites, malnutrition and previous abdominal surgery, partly predicted the operative blood loss and patient survival. In conclusion, orthotopic liver transplantation is being performed in Australia with survival rates that are comparable with those of established overseas units.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose This study evaluated the impact of patient set-up errors on the probability of pulmonary and cardiac complications in the irradiation of left-sided breast cancer. Methods and Materials Using the CMS XiO Version 4.6 (CMS Inc., St Louis, MO) radiotherapy planning system's NTCP algorithm and the Lyman -Kutcher-Burman (LKB) model, we calculated the DVH indices for the ipsilateral lung and heart and the resultant normal tissue complication probabilities (NTCP) for radiation-induced pneumonitis and excess cardiac mortality in 12 left-sided breast cancer patients. Results Isocenter shifts in the posterior direction had the greatest effect on the lung V20, heart V25, mean and maximum doses to the lung and the heart. Dose volume histograms (DVH) results show that the ipsilateral lung V20 tolerance was exceeded in 58% of the patients after 1cm posterior shifts. Similarly, the heart V25 tolerance was exceeded after 1cm antero-posterior and left-right isocentric shifts in 70% of the patients. The baseline NTCPs for radiation-induced pneumonitis ranged from 0.73% - 3.4% with a mean value of 1.7%. The maximum reported NTCP for radiation-induced pneumonitis was 5.8% (mean 2.6%) after 1cm posterior isocentric shift. The NTCP for excess cardiac mortality were 0 % in 100% of the patients (n=12) before and after setup error simulations. Conclusions Set-up errors in left sided breast cancer patients have a statistically significant impact on the Lung NTCPs and DVH indices. However, with a central lung distance of 3cm or less (CLD <3cm), and a maximum heart distance of 1.5cm or less (MHD<1.5cm), the treatment plans could tolerate set-up errors of up to 1cm without any change in the NTCP to the heart.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To examine the association between preoperative quality of life (QoL) and postoperative adverse events in women treated for endometrial cancer. Methods: 760 women with apparent Stage I endometrial cancer were randomised into a clinical trial evaluating laparoscopic versus open surgery. This analysis includes women with preoperative QoL measurements, from the Functional Assessment of Cancer Therapy- General (FACT-G) questionnaire, and who were followed up for at least 6 weeks after surgery (n=684). The outcomes for this study were defined as (1) the occurrence of moderate to severe AEs adverse events within 6 months (Common Toxicology Criteria (CTC) grade ≥3); and (2) any Serious Adverse Event (SAE). The association between preoperative QoL and the occurrence of AE was examined, after controlling for baseline comorbidity and other factors. Results: After adjusting for other factors, odds of occurrence of AE of CTC grade ≥3 were significantly increased with each unit decrease in baseline FACT-G score (OR=1.02, 95% CI 1.00-1.03, p=0.030), which was driven by physical well-being (PWB) (OR=1.09, 95% CI 1.04-1.13, p=0.0002) and functional well-being subscales (FWB) (OR=1.04, 95% CI 1.00-1.07, p=0.035). Similarly, odds of SAE occurrence were significantly increased with each unit decrease in baseline FACT-G score (OR=1.02, 95% CI 1.01-1.04, p=0.011), baseline PWB (OR=1.11, 95% CI 1.06-1.16, p<0.0001) or baseline FWB subscales (OR=1.05, 95% CI 1.01-1.10, p=0.0077). Conclusion: Women with early endometrial cancer presenting with lower QoL prior to surgery are at higher risk of developing a serious adverse event following surgery. Funding: Cancer Council Queensland, Cancer Council New South Wales, Cancer Council Victoria, Cancer Council, Western Australia; NHMRC project grant 456110; Cancer Australia project grant 631523; The Women and Infants Research Foundation, Western Australia; Royal Brisbane and Women’s Hospital Foundation; Wesley Research Institute; Gallipoli Research Foundation; Gynetech; TYCO Healthcare, Australia; Johnson and Johnson Medical, Australia; Hunter New England Centre for Gynaecological Cancer; Genesis Oncology Trust; and Smart Health Research Grant QLD Health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Patients may need massive volume-replacement therapy after cardiac surgery because of large fluid transfer perioperatively, and the use of cardiopulmonary bypass. Hemodynamic stability is better maintained with colloids than crystalloids but colloids have more adverse effects such as coagulation disturbances and impairment of renal function than do crystalloids. The present study examined the effects of modern hydroxyethyl starch (HES) and gelatin solutions on blood coagulation and hemodynamics. The mechanism by which colloids disturb blood coagulation was investigated by thromboelastometry (TEM) after cardiac surgery and in vitro by use of experimental hemodilution. Materials and methods: Ninety patients scheduled for elective primary cardiac surgery (Studies I, II, IV, V), and twelve healthy volunteers (Study III) were included in this study. After admission to the cardiac surgical intensive care unit (ICU), patients were randomized to receive different doses of HES 130/0.4, HES 200/0.5, or 4% albumin solutions. Ringer’s acetate or albumin solutions served as controls. Coagulation was assessed by TEM, and hemodynamic measurements were based on thermodilutionally measured cardiac index (CI). Results: HES and gelatin solutions impaired whole blood coagulation similarly as measured by TEM even at a small dose of 7 mL/kg. These solutions reduced clot strength and prolonged clot formation time. These effects were more pronounced with increasing doses of colloids. Neither albumin nor Ringer’s acetate solution disturbed blood coagulation significantly. Coagulation disturbances after infusion of HES or gelatin solutions were clinically slight, and postoperative blood loss was comparable with that of Ringer’s acetate or albumin solutions. Both single and multiple doses of all the colloids increased CI postoperatively, and this effect was dose-dependent. Ringer’s acetate had no effect on CI. At a small dose (7 mL/kg), the effect of gelatin on CI was comparable with that of Ringer’s acetate and significantly less than that of HES 130/0.4 (Study V). However, when the dose was increased to 14 and 21 mL/kg, the hemodynamic effect of gelatin rose and became comparable with that of HES 130/0.4. Conclusions: After cardiac surgery, HES and gelatin solutions impaired clot strength in a dose-dependent manner. The potential mechanisms were interaction with fibrinogen and fibrin formation, resulting in decreased clot strength, and hemodilution. Although the use of HES and gelatin inhibited coagulation, postoperative bleeding on the first postoperative morning in all the study groups was similar. A single dose of HES solutions improved CI postoperatively more than did gelatin, albumin, or Ringer’s acetate. However, when administered in a repeated fashion, (cumulative dose of 14 mL/kg or more), no differences were evident between HES 130/0.4 and gelatin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mediastinitis as a complication after cardiac surgery is rare but disastrous increasing the hospital stay, hospital costs, morbidity and mortality. It occurs in 1-3 % of patients after median sternotomy. The purpose of this study was to find out the risk factors and also to investigate new ways to prevent mediastinitis. First, we assessed operating room air contamination monitoring by comparing the bacteriological technique with continuous particle counting in low level contamination achieved by ultra clean garment options in 66 coronary artery bypass grafting operations. Second, we examined surgical glove perforations and the changes in bacterial flora of surgeons' fingertips in 116 open-heart operations. Third, the effect of gentamicin-collagen sponge on preventing surgical site infections (SSI) was studied in randomized controlled study with 557 participants. Finally, incidence, outcome, and risk factors of mediastinitis were studied in over 10,000 patients. With the alternative garment and textile system (cotton group and clean air suit group), the air counts fell from 25 to 7 colony-forming units/m3 (P<0.01). The contamination of the sternal wound was reduced by 46% and that of the leg wound by >90%. In only 17% operations both gloves were found unpunctured. Frequency of glove perforations and bacteria counts of hands were found to increase with operation time. With local gentamicin prophylaxis slightly less SSIs (4.0 vs. 5.9%) and mediastinitis (1.1 vs. 1.9%) occurred. We identified 120/10713 cases of postoperative mediastinitis (1.1%). During the study period, the patient population grew significantly older, the proportion of women and patients with ASA score >3 increased significantly. In multivariate logistic regression analysis, the only significant predictor for mediastinitis was obesity. Continuous particle monitoring is a good intraoperative method to control the air contamination related to the theatre staff behavior during individual operation. When a glove puncture is detected, both gloves are to be changed. Before donning a new pair of gloves, the renewed disinfection of hands will help to keep their bacterial counts lower even towards the end of long operation. Gentamicin-collagen sponge may have beneficial effects on the prevention of SSI, but further research is needed. Mediastinitis is not diminishing. Larger populations at risk, for example proportions of overweight patients, reinforce the importance of surveillance and pose a challenge in focusing preventive measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Continuous epidural analgesia (CEA) and continuous spinal postoperative analgesia (CSPA) provided by a mixture of local anaesthetic and opioid are widely used for postoperative pain relief. E.g., with the introduction of so-called microcatheters, CSPA found its way particularly in orthopaedic surgery. These techniques, however, may be associated with dose-dependent side-effects as hypotension, weakness in the legs, and nausea and vomiting. At times, they may fail to offer sufficient analgesia, e.g., because of a misplaced catheter. The correct position of an epidural catheter might be confirmed by the supposedly easy and reliable epidural stimulation test (EST). The aims of this thesis were to determine a) whether the efficacy, tolerability, and reliability of CEA might be improved by adding the α2-adrenergic agonists adrenaline and clonidine to CEA, and by the repeated use of EST during CEA; and, b) the feasibility of CSPA given through a microcatheter after vascular surgery. Studies I IV were double-blinded, randomized, and controlled trials; Study V was of a diagnostic, prospective nature. Patients underwent arterial bypass surgery of the legs (I, n=50; IV, n=46), total knee arthroplasty (II, n=70; III, n=72), and abdominal surgery or thoracotomy (V, n=30). Postoperative lumbar CEA consisted of regular mixtures of ropivacaine and fentanyl either without or with adrenaline (2 µg/ml (I) and 4 µg/ml (II)) and clonidine (2 µg/ml (III)). CSPA (IV) was given through a microcatheter (28G) and contained either ropivacaine (max. 2 mg/h) or a mixture of ropivacaine (max. 1 mg/h) and morphine (max. 8 µg/h). Epidural catheter tip position (V) was evaluated both by EST at the moment of catheter placement and several times during CEA, and by epidurography as reference diagnostic test. CEA and CSPA were administered for 24 or 48 h. Study parameters included pain scores assessed with a visual analogue scale, requirements of rescue pain medication, vital signs, and side-effects. Adrenaline (I and II) had no beneficial influence as regards the efficacy or tolerability of CEA. The total amounts of epidurally-infused drugs were even increased in the adrenaline group in Study II (p=0.02, RM ANOVA). Clonidine (III) augmented pain relief with lowered amounts of epidurally infused drugs (p=0.01, RM ANOVA) and reduced need for rescue oxycodone given i.m. (p=0.027, MW-U; median difference 3 mg (95% CI 0 7 mg)). Clonidine did not contribute to sedation and its influence on haemodynamics was minimal. CSPA (IV) provided satisfactory pain relief with only limited blockade of the legs (no inter-group differences). EST (V) was often related to technical problems and difficulties of interpretation, e.g., it failed to identify the four patients whose catheters were outside the spinal canal already at the time of catheter placement. As adjuvants to lumbar CEA, clonidine only slightly improved pain relief, while adrenaline did not provide any benefit. The role of EST applied at the time of epidural catheter placement or repeatedly during CEA remains open. The microcatheter CSPA technique appeared effective and reliable, but needs to be compared to routine CEA after peripheral arterial bypass surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adequacy of anesthesia has been studied since the introduction of balanced general anesthesia. Commercial monitors based on electroencephalographic (EEG) signal analysis have been available for monitoring the hypnotic component of anesthesia from the beginning of the 1990s. Monitors measuring the depth of anesthesia assess the cortical function of the brain, and have gained acceptance during surgical anesthesia with most of the anesthetic agents used. However, due to frequent artifacts, they are considered unsuitable for monitoring consciousness in intensive care patients. The assessment of analgesia is one of the cornerstones of general anesthesia. Prolonged surgical stress may lead to increased morbidity and delayed postoperative recovery. However, no validated monitoring method is currently available for evaluating analgesia during general anesthesia. Awareness during anesthesia is caused by an inadequate level of hypnosis. This rare but severe complication of general anesthesia may lead to marked emotional stress and possibly posttraumatic stress disorder. In the present series of studies, the incidence of awareness and recall during outpatient anesthesia was evaluated and compared with that of in inpatient anesthesia. A total of 1500 outpatients and 2343 inpatients underwent a structured interview. Clear intraoperative recollections were rare the incidence being 0.07% in outpatients and 0.13% in inpatients. No significant differences emerged between outpatients and inpatients. However, significantly smaller doses of sevoflurane were administered to outpatients with awareness than those without recollections (p<0.05). EEG artifacts in 16 brain-dead organ donors were evaluated during organ harvest surgery in a prospective, open, nonselective study. The source of the frontotemporal biosignals in brain-dead subjects was studied, and the resistance of bispectral index (BIS) and Entropy to the signal artifacts was compared. The hypothesis was that in brain-dead subjects, most of the biosignals recorded from the forehead would consist of artifacts. The original EEG was recorded and State Entropy (SE), Response Entropy (RE), and BIS were calculated and monitored during solid organ harvest. SE differed from zero (inactive EEG) in 28%, RE in 29%, and BIS in 68% of the total recording time (p<0.0001 for all). The median values during the operation were SE 0.0, RE 0.0, and BIS 3.0. In four of the 16 organ donors, EEG was not inactive, and unphysiologically distributed, nonreactive rhythmic theta activity was present in the original EEG signal. After the results from subjects with persistent residual EEG activity were excluded, SE, RE, and BIS differed from zero in 17%, 18%, and 62% of the recorded time, respectively (p<0.0001 for all). Due to various artifacts, the highest readings in all indices were recorded without neuromuscular blockade. The main sources of artifacts were electrocauterization, electromyography (EMG), 50-Hz artifact, handling of the donor, ballistocardiography, and electrocardiography. In a prospective, randomized study of 26 patients, the ability of Surgical Stress Index (SSI) to differentiate patients with two clinically different analgesic levels during shoulder surgery was evaluated. SSI values were lower in patients with an interscalene brachial plexus block than in patients without an additional plexus block. In all patients, anesthesia was maintained with desflurane, the concentration of which was targeted to maintain SE at 50. Increased blood pressure or heart rate (HR), movement, and coughing were considered signs of intraoperative nociception and treated with alfentanil. Photoplethysmographic waveforms were collected from the contralateral arm to the operated side, and SSI was calculated offline. Two minutes after skin incision, SSI was not increased in the brachial plexus block group and was lower (38 ± 13) than in the control group (58 ± 13, p<0.005). Among the controls, one minute prior to alfentanil administration, SSI value was higher than during periods of adequate antinociception, 59 ± 11 vs. 39 ± 12 (p<0.01). The total cumulative need for alfentanil was higher in controls (2.7 ± 1.2 mg) than in the brachial plexus block group (1.6 ± 0.5 mg, p=0.008). Tetanic stimulation to the ulnar region of the hand increased SSI significantly only among patients with a brachial plexus block not covering the site of stimulation. Prognostic value of EEG-derived indices was evaluated and compared with Transcranial Doppler Ultrasonography (TCD), serum neuron-specific enolase (NSE) and S-100B after cardiac arrest. Thirty patients resuscitated from out-of-hospital arrest and treated with induced mild hypothermia for 24 h were included. Original EEG signal was recorded, and burst suppression ratio (BSR), RE, SE, and wavelet subband entropy (WSE) were calculated. Neurological outcome during the six-month period after arrest was assessed with the Glasgow-Pittsburgh Cerebral Performance Categories (CPC). Twenty patients had a CPC of 1-2, one patient had a CPC of 3, and nine patients died (CPC 5). BSR, RE, and SE differed between good (CPC 1-2) and poor (CPC 3-5) outcome groups (p=0.011, p=0.011, p=0.008, respectively) during the first 24 h after arrest. WSE was borderline higher in the good outcome group between 24 and 48 h after arrest (p=0.050). All patients with status epilepticus died, and their WSE values were lower (p=0.022). S-100B was lower in the good outcome group upon arrival at the intensive care unit (p=0.010). After hypothermia treatment, NSE and S-100B values were lower (p=0.002 for both) in the good outcome group. The pulsatile index was also lower in the good outcome group (p=0.004). In conclusion, the incidence of awareness in outpatient anesthesia did not differ from that in inpatient anesthesia. Outpatients are not at increased risk for intraoperative awareness relative to inpatients undergoing general anesthesia. SE, RE, and BIS showed non-zero values that normally indicate cortical neuronal function, but were in these subjects mostly due to artifacts after clinical brain death diagnosis. Entropy was more resistant to artifacts than BIS. During general anesthesia and surgery, SSI values were lower in patients with interscalene brachial plexus block covering the sites of nociceptive stimuli. In detecting nociceptive stimuli, SSI performed better than HR, blood pressure, or RE. BSR, RE, and SE differed between the good and poor neurological outcome groups during the first 24 h after cardiac arrest, and they may be an aid in differentiating patients with good neurological outcomes from those with poor outcomes after out-of-hospital cardiac arrest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anterior cruciate ligament (ACL) tear is a common sports injury of the knee. Arthroscopic reconstruction using autogenous graft material is widely used for patients with ACL instability. The grafts most commonly used are the patellar and the hamstring tendons, by various fixation techniques. Although clinical evaluation and conventional radiography are routinely used in follow-up after ACL surgery, magnetic resonance imaging (MRI) plays an important role in the diagnosis of complications after ACL surgery. The aim of this thesis was to study the clinical outcome of patellar and hamstring tendon ACL reconstruction techniques. In addition, the postoperative appearance of the ACL graft was evaluated using several MRI sequences. Of the 175 patients who underwent an arthroscopically assisted ACL reconstruction, 99 patients were randomized into patellar tendon (n=51) or hamstring tendon (n=48) groups. In addition, 62 patients with hamstring graft ACL reconstruction were randomized into either cross-pin (n=31) or interference screw (n=31) fixation groups. Follow-up evaluation determined knee laxity, isokinetic muscle performance and several knee scores. Lateral and anteroposterior view radiographs were obtained. Several MRI sequences were obtained with a 1.5-T imager. The appearance and enhancement pattern of the graft and periligamentous tissue, and the location of bone tunnels were evaluated. After MRI, arthroscopy was performed on 14 symptomatic knees. The results revealed no significant differences in the 2-year outcome between the groups. In the hamstring tendon group, the average femoral and tibial bone tunnel diameter increased during 2 years follow-up by 33% and 23%, respectively. In the asymptomatic knees, the graft showed homogeneous and low signal intensity with periligamentous streaks of intermediate signal intensity on T2-weighted MR images. In the symptomatic knees, arthroscopy revealed 12 abnormal grafts and two meniscal tears, each with an intact graft. Among 3 lax grafts visible on arthroscopy, MRI showed an intact graft and improper bone tunnel placement. For diagnosing graft failure, all MRI findings combined gave a specificity of 90% and a sensitivity of 81%. In conclusion, all techniques appeared to improve patients' performance, and were therefore considered as good choices for ACL reconstruction. In follow-up, MRI permits direct evaluation of the ACL graft, the bone tunnels, and additional disorders of the knee. Bone tunnel enlargement and periligamentous tissue showing contrast enhancement were non-specific MRI findings that did not signify ACL deficiency. With an intact graft and optimal femoral bone tunnel placement, graft deficiency is unlikely, and the MRI examination should be carefully scrutinized for possible other causes for the patients symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To investigate the efficacy of Eye Movement Desensitization and Reprocessing for postoperative pain management in adolescents. Background Eye Movement Desensitization and Reprocessing is an inexpensive, non-pharmacological intervention that has successfully been used to treat chronic pain. It holds promise in the treatment of acute, postsurgical pain based on its purported effects on the brain and nervous system. Design A randomized controlled trial was used. Methods Fifty-six adolescent surgical patients aged between 12-18 years were allocated to gender-balanced Eye Movement Desensitization and Reprocessing (treatment) or non-Eye Movement Desensitization and Reprocessing (control) groups. Pain was measured using the Wong-Baker FACES® Pain Rating Scale (WBFS) before and after the intervention (or non-intervention for the control group). Findings A Wilcoxon signed-rank test demonstrated that the Eye Movement Desensitization and Reprocessing group experienced a significant reduction in pain intensity after treatment intervention, whereas the control group did not. Additionally, a Mann–Whitney U-test showed that, while there was no significant difference between the two groups at time 1, there was a significant difference in pain intensity between the two groups at time 2, with the Eye Movement Desensitization and Reprocessing group experiencing lower levels of pain. Conclusion These results suggest that Eye Movement Desensitization and Reprocessing may be an effective treatment modality for postoperative pain.