981 resultados para Portable.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assembling of a system for field sampling and activity concentration measurement of radon dissolved in groundwater is described. Special attention is given in presenting the calibration procedure to obtain the radon activity concentration in groundwater from the raw counting rate registered in a portable scintillation detector and in establishing the precision of the activity concentration measurements. A field procedure was established and the system tested during one year of monthly observations of (222)Rn activity concentration in groundwater drawn from two wells drilled on metamorphic rocks exposed at Eastern Sao Paulo State, Brazil. The observed mean (222)Rn activity concentrations are 374 Bq/dm(3) in one well and about 1275 Bq/dm(3) in the other one. In both wells the (222)Rn activity concentrations showed a seasonal variation similar to variations previously reported in the literature for the same region. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary beam spectra were obtained for an X-ray industrial equipment (40-150 kV), and for a clinical mammography apparatus (25-35 kV) from beams scattered at angles close to 90 degrees, measured with a CdTe Compton spectrometer. Actual scattering angles were determined from the Compton energy shift of characteristic X-rays or spectra end-point energy. Evaluated contribution of coherent scattering amounts to more than 15% of fluence in mammographic beams. This technique can be used in clinical environments. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The trend away from full-time permanent employment raises questions about the relevance of traditional approaches to managing and compensating employees. Employment in the Australian building industry is characterised by short-term, project-based employment. Employers and unions in the industry have adopted alternative compensation models to accommodate the short-term nature of employment, most notably through portable benefit schemes. In 1997, the Victorian building industry extended the range of portable benefits to include sick leave. Empirical evidence suggests a relationship between employee absence behaviour and accrual entitlement models. Research reported here supports this link, and suggests that both employers and employees can benefit from an alternative, portable, approach to accrued entitlements. Employers can benefit because employees may be less likely to take an instrumental approach to their entitlements. Employees benefit because they are able to accrue entitlements for the period they remain in the building industry, irrespective of the extent to which they change jobs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

If it is the case that artists and art explore organization of the brain (Zeki & Lamb, 1994), then the investigation of response to artistic performance holds promise as a window to perceptual and cognitive processes. The portable Audience Response Facility (pARF) is an instrument for recording real‐time audience response (Stevens et al. 2009). Twenty, handheld, Personal Digital Assistants (PDAs) collect responses on customizable skin interfaces. The pARF server transmits the customizable options, synchronizes devices and collects data for export. In this paper we report ratings of the usability of the pARF that were collected after 37 participants had used it to continuously rate engagement along a single dimension while a female dance artist gave two performances of a short solo contemporary dance work. The motion of the dancer was also captured as she performed the piece but only usability rating data are reported here. Ratings indicate that the cognitive load imposed by continuously rating engagement while watching a dance performance was manageable and the pARF was easy to use. An extended familiarization phase may further reduce dual task demand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The filling of printed forms has always been an issue for the visually impaired. Though optical character recognition technology has helped many blind people to ‘read’ the world, there is not a single device that allows them to fill out a paper-based form without a human assistant. The task of filling forms is however an essential part of their daily lives, for example, for access to social security or benefits. This paper describes a solution that allows a blind person to complete paper-based forms, pervasively and independently, using only off-the-shelf equipment including a Smartphone, a clipboard with sliding ruler, and a ballpoint pen. A dynamic color fiduciary (point of reference) marker is designed so that it can be moved by the user to any part of the form such that all regions can be “visited”. This dynamic color fiduciary marker is robust to camera focus and partial occlusion, allowing flexibility in handling the Smartphone with embedded camera. Feedback is given to the blind user via both voice and tone to facilitate efficient guidance in filling out the form. Experimental results have shown that this prototype can help visually impaired people to fill out a form independently.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The remote real-time detection of specific arsenic species would significantly benefit in minerals processing to mitigate the release of arsenic into aquatic environments and aid in selective mining. At present, there are no technologies available to detect arsenic minerals in bulk volumes outside of laboratories. Here we report on the first room-temperature broadband 75As nuclear quadrupole resonance (NQR) detection of common and abundant arsenic ores in the Earth crust using a large sample (0.78 L) volume prototype sensor. Broadband excitation aids in detection of natural minerals with low crystallinity. We briefly discuss how the proposed NQR detector could be employed in mining operations. Key Points Transformation of chemical analysis method to geophysical detection technologyFirst NQR ore characterization of selected arsenic minerals in bulk volumesBroadband NQR sensor to detect arsenic minerals with low crystallinity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-audio signals have been recorded in the flash ROM memory of a portable MP3 player, in WAV format file, to examine the possibility of using these cheap and small instruments as general-purpose portable data loggers. A 1200-Hz FM carrier modulated by the non-audio signal has replaced the microphone signal, while using the REC operating mode of the MP3 player, which triggers the voice recording function. The signal recovery was carried out by a PLL-based FM demodulator whose input is the FM signal captured in the coil leads of the MP3 player's earphone. Sinusoidal and electrocardiogram signals have been used in the system evaluation. Although the quality of low frequency signals needs improvement, overall the results indicate the viability of the proposal. Suggestions are made for improvements and extensions of the work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To compare results reported for blood gas partial pressures, electrolyte concentrations, and Hct in venous blood samples collected from cattle, horses, and sheep and analyzed by use of a portable clinical analyzer (PCA) and reference analyzer (RA).Animals-Clinically normal animals (24 cattle, 22 horses, and 22 sheep).Procedures-pH; Pco(2); Po(2); total carbon dioxide concentration; oxygen saturation; base excess; concentrations of HCO(3)(-), Na(+), K(+), and ionized calcium; Hct; and hemoglobin concentration were determined with a PCA. Results were compared with those obtained for the same blood sample with an RA. Bias (mean difference) and variability (95% confidence interval) were determined for all data reported. Data were also subjected to analyses by Deming regression and Pearson correlation.Results-Analysis of Bland-Altman plots revealed good agreement between results obtained with the PCA and those obtained with the RA for pH and total carbon dioxide concentration in cattle, K(+) concentration in horses and sheep, and base excess in horses. Except for Na(+) concentration and Hct in horses and sheep, correlation was good or excellent for most variables reported.Conclusions and Clinical Relevance-Data from blood gas and electrolyte analyses obtained by use of the PCA can be used to evaluate the health status of cattle, horses, and sheep. Furthermore, the handheld PCA device may have a great advantage over the RA device as a result of the ability to analyze blood samples on farms that may be located far from urban centers. (Am J Vet Res 2010;71:515-521)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tungsten coil atomic emission spectrometry is an ideal technique for field applications because of its simplicity, low cost, low power requirement, and independence from cooling systems. A new, portable, compact design is reported here. The tungsten coil is extracted from an inexpensive 24 V, 250 W commercial light bulb. The coil is housed in a small, aluminum cell. The emission signal exits from a small aperture in the cell, while the bulk of the blackbody emission from the tungsten coil is blocked. The resulting spectra exhibit extremely low background signals. The atomization cell, a single lens, and a hand-held charge coupled device (CCD) spectrometer are fixed on a 1 x 6 x 30 cm ceramic base. The resulting system is robust and easily transported. A programmable, miniature 400 W solid-state constant current power supply controls the temperature of the coil. Fifteen elements are determined with the system (Ba, Cs, Li, Rb, Cr, Sr, Eu, Yb, Mn, Fe, Cu, Mg, V, Al, and Ga). The precision ranges from 4.3% to 8.4% relative standard deviation for repetitive measurements of the same solution. Detection limits are in the 0.04 to 1500 mu g/L range. Accuracy is tested using standard reference materials for polluted water, peach leaves, and tomato leaves. For those elements present above the detection limit, recoveries range from 72% to 147%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A portable or field test method for simultaneous spectrophotometric determination of calcium and magnesium in water using multivariate partial least squares (PLS) calibration methods is proposed. The method is based on the reaction between the analytes and methylthymol blue at pH 11. The spectral information was used as the X-block, and the Ca(II) and Mg(II) concentrations obtained by a reference technique (ICP-AES) were used as the Y-block. Two series of analyses were performed, with a month's difference between them. The first series was used as the calibration set and the second one as the validation set. Multivariate statistical process control (MSPC) techniques, based on statistics from principal component models, were used to study the features and evolution with time of the spectral signals. Signal standardization was used to correct the deviations between series. Method validation was performed by comparing the predictions of the PLS model with the reference Ca(II) and Mg(II) concentrations determined by ICP-AES using the joint interval test for the slope and intercept of the regression line with errors in both axes. (C) 1998 John Wiley & Sons, Ltd.