843 resultados para Neonatal screening
Resumo:
Preterm infants have an increased risk of low bone mass and subsequent fracture due to limited bone mass accretion in utero and a greater need for bone nutrients. The diagnosis of ostepeonia of prematurity remains difficult as there is no sctreening test which is both sensitive and specific.
Resumo:
First-degree relatives of men with prostate cancer have a higher risk of being diagnosed with prostate cancer than men without a family history. The present review examines the prevalence and predictors of testing in first-degree relatives, perceptions of risk, prostate cancer knowledge and psychological consequences of screening. Medline, PsycInfo and Cinahl databases were searched for articles examining risk perceptions or screening practices of first-degree relatives of men with prostate cancer for the period of 1990 to August 2007. Eighteen studies were eligible for inclusion. First-degree relatives participated in prostate-specific antigen (PSA) testing more and perceived their risk of prostate cancer to be higher than men without a family history. Family history factors (e.g. being an unaffected son rather than an unaffected brother) were consistent predictors of PSA testing. Studies were characterized by sampling biases and a lack of longitudinal assessments. Prospective, longitudinal assessments with well-validated and comprehensive measures are needed to identify factors that cue the uptake of screening and from this develop an evidence base for decision support. Men with a family history may benefit from targeted communication about the risks and benefits of prostate cancer testing that responds to the implications of their heightened risk.
Resumo:
To further investigate the use of DNA repair-enhancing agents for skin cancer prevention, we treated Cdk4R24C/R24C/NrasQ61K mice topically with the T4 endonuclease V DNA repair enzyme (known as Dimericine) immediately prior to neonatal ultraviolet radiation (UVR) exposure, which has a powerful effect in exacerbating melanoma development in the mouse model. Dimericine has been shown to reduce the incidence of basal-cell and squamous cell carcinoma. Unexpectedly, we saw no difference in penetrance or age of onset of melanoma after neonatal UVR between Dimericine-treated and control animals, although the drug reduced DNA damage and cellular proliferation in the skin. Interestingly, epidermal melanocytes removed cyclobutane pyrimidine dimers (CPDs) more efficiently than surrounding keratinocytes. Our study indicates that neonatal UVR-initiated melanomas may be driven by mechanisms other than solely that of a large CPD load and/or their inefficient repair. This is further suggestive of different mechanisms by which UVR may enhance the transformation of keratinocytes and melanocytes.
Resumo:
A wide range of screening strategies have been employed to isolate antibodies and other proteins with specific attributes, including binding affinity, specificity, stability and improved expression. However, there remains no high-throughput system to screen for target-binding proteins in a mammalian, intracellular environment. Such a system would allow binding reagents to be isolated against intracellular clinical targets such as cell signalling proteins associated with tumour formation (p53, ras, cyclin E), proteins associated with neurodegenerative disorders (huntingtin, betaamyloid precursor protein), and various proteins crucial to viral replication (e.g. HIV-1 proteins such as Tat, Rev and Vif-1), which are difficult to screen by phage, ribosome or cell-surface display. This study used the β-lactamase protein complementation assay (PCA) as the display and selection component of a system for screening a protein library in the cytoplasm of HEK 293T cells. The colicin E7 (ColE7) and Immunity protein 7 (Imm7) *Escherichia coli* proteins were used as model interaction partners for developing the system. These proteins drove effective β-lactamase complementation, resulting in a signal-to-noise ratio (9:1 – 13:1) comparable to that of other β-lactamase PCAs described in the literature. The model Imm7-ColE7 interaction was then used to validate protocols for library screening. Single positive cells that harboured the Imm7 and ColE7 binding partners were identified and isolated using flow cytometric cell sorting in combination with the fluorescent β-lactamase substrate, CCF2/AM. A single-cell PCR was then used to amplify the Imm7 coding sequence directly from each sorted cell. With the screening system validated, it was then used to screen a protein library based the Imm7 scaffold against a proof-of-principle target. The wild-type Imm7 sequence, as well as mutants with wild-type residues in the ColE7- binding loop were enriched from the library after a single round of selection, which is consistent with other eukaryotic screening systems such as yeast and mammalian cell-surface display. In summary, this thesis describes a new technology for screening protein libraries in a mammalian, intracellular environment. This system has the potential to complement existing screening technologies by allowing access to intracellular proteins and expanding the range of targets available to the pharmaceutical industry.
Resumo:
Background: The Malnutrition Screening Tool (MST) is a valid nutrition screening tool in the acute hospital setting but has not been assessed in residential aged care facilities. The aim of this secondary analysis was to determine whether the MST could be a useful nutrition screening tool when compared with a full nutrition assessment by Subjective Global Assessment (SGA) in the residential aged care setting. ----- Methods: Two hundred and eighty-five residents (29% male; mean age: 84 ± 9 years) from eight residential aged care facilities in Australia participated. A secondary analysis of data collected during a nutrition intervention study was conducted. The MST consists of two questions related to recent weight loss and appetite. While the MST was not specifically applied, weight loss and appetite information was available and an estimated MST score (0-5) calculated. Nutritional status was assessed by a research assistant trained in using SGA. ----- Results: Malnutrition prevalence was 42.8% (122 malnourished out of 285 residents). Compared to the SGA, the MST was an effective predictor of nutritional risk (sensitivity = 83.6%, specificity = 65.6%, positive predictive value = 0.65, negative predictive value =0.84). ----- Conclusions: The components of the MST have acceptable sensitivity and specificity suggesting it can play a valuable role in quickly identifying malnutrition risk in the residential aged care setting. Further prospective research using the MST tool against a broader array of objective and subjective nutritional parameters is required to confirm its validity as a screening tool in aged care settings.
Resumo:
The World Report on Children and Violence, (Pinheiro, 2006) was produced at the request of the UN Secretary General and the UN General Assembly. This report recommended improvement in research on child abuse. ISPCAN representatives took this charge and developed 3 new instruments. We describe this background and introduce three new measures designed to assess the incidence and prevalence of child abuse and neglect.
Resumo:
Purpose: This two-part research project was undertaken as part of the planning process by Queensland Health (QH), Cancer Screening Services Unit (CSSU), Queensland Bowel Cancer Screening Program (QBCSP), in partnership with the National Bowel Cancer Screening Program (NBCSP), to prepare for the implementation of the NBCSP in public sector colonoscopy services in QLD in late 2006. There was no prior information available on the quality of colonoscopy services in Queensland (QLD) and no prior studies that assessed the quality of colonoscopy training in Australia. Furthermore, the NBCSP was introduced without extra funding for colonoscopy service improvement or provision for increases in colonoscopic capacity resulting from the introduction of the NBCSP. The main purpose of the research was to record baseline data on colonoscopy referral and practice in QLD and current training in colonoscopy Australia-wide. It was undertaken from a quality improvement perspective. Implementation of the NBCSP requires that all aspects of the screening pathway, in particular colonoscopy services for the assessment of positive Faecal Occult Blood Tests (FOBTs), will be effective, efficient, equitable and evidence-based. This study examined two important aspects of the continuous quality improvement framework for the NBCSP as they relate to colonoscopy services: (1) evidence-based practice, and (2) quality of colonoscopy training. The Principal Investigator was employed as Senior Project Officer (Training) in the QBCSP during the conduct of this research project. Recommendations from this research have been used to inform the development and implementation of quality improvement initiatives for provision of colonoscopy in the NBCSP, its QLD counterpart the QBCSP and colonoscopy services in QLD, in general. Methods – Part 1 Chart audit of evidence-based practice: The research was undertaken in two parts from 2005-2007. The first part of this research comprised a retrospective chart audit of 1484 colonoscopy records (some 13% of all colonoscopies conducted in public sector facilities in the year 2005) in three QLD colonoscopy services. Whilst some 70% of colonoscopies are currently conducted in the private sector, only public sector colonoscopy facilities provided colonoscopies under the NBCSP. The aim of this study was to compare colonoscopy referral and practice with explicit criteria derived from the National Health & Medical Research Council (NHMRC) (1999) Clinical Practice Guidelines for the Prevention, Early Detection and Management of Colorectal Cancer, and describe the nature of variance with the guidelines. Symptomatic presentations were the most common indication for colonoscopy (60.9%). These comprised per rectal bleeding (31.0%), change of bowel habit (22.1%), abdominal pain (19.6%), iron deficiency anaemia (16.2%), inflammatory bowel disease (8.9%) and other symptoms (11.4%). Surveillance and follow-up colonoscopies accounted for approximately one-third of the remaining colonoscopy workload across sites. Gastroenterologists (GEs) performed relatively more colonoscopies per annum (59.9%) compared to general surgeons (GS) (24.1%), colorectal surgeons (CRS) (9.4%) and general physicians (GPs) (6.5%). Guideline compliance varied with the designation of the colonoscopist. Compliance was lower for CRS (62.9%) compared to GPs (76.0%), GEs (75.0%), GSs (70.9%, p<0.05). Compliance with guideline recommendations for colonoscopic surveillance for family history of colorectal cancer (23.9%), polyps (37.0%) and a past history of bowel cancer (42.7%), was by comparison significantly lower than for symptomatic presentations (94.4%), (p<0.001). Variation with guideline recommendations occurred more frequently for polyp surveillance (earlier than guidelines recommend, 47.9%) and follow-up for past history of bowel cancer (later than recommended, 61.7%, p<0.001). Bowel cancer cases detected at colonoscopy comprised 3.6% of all audited colonoscopies. Incomplete colonoscopies occurred in 4.3% of audited colonoscopies and were more common among women (76.6%). For all colonoscopies audited, the rate of incomplete colonoscopies for GEs was 1.6% (CI 0.9-2.6), GPs 2.0% (CI 0.6-7.2), GS 7.0% (CI 4.8-10.1) and CRS 16.4% (CI 11.2-23.5). 18.6% (n=55) of patients with a documented family history of bowel cancer had colonoscopy performed against guidelines recommendations (for general (category 1) population risk, for reasons of patient request or family history of polyps, rather than for high risk status for colorectal cancer). In general, family history was inadequately documented and subsequently applied to colonoscopy referral and practice. Methods - Part 2 Surveys of quality of colonoscopy training: The second part of the research consisted of Australia-wide anonymous, self-completed surveys of colonoscopy trainers and their trainees to ascertain their opinions on the current apprenticeship model of colonoscopy in Australia and to identify any training needs. Overall, 127 surveys were received from colonoscopy trainers (estimated response rate 30.2%). Approximately 50% of trainers agreed and 27% disagreed that current numbers of training places were adequate to maintain a skilled colonoscopy workforce in preparation for the NBCSP. Approximately 70% of trainers also supported UK-style colonoscopy training within dedicated accredited training centres using a variety of training approaches including simulation. A collaborative approach with the private sector was seen as beneficial by 65% of trainers. Non-gastroenterologists (non-GEs) were more likely than GEs to be of the opinion that simulators are beneficial for colonoscopy training (χ2-test = 5.55, P = 0.026). Approximately 60% of trainers considered that the current requirements for recognition of training in colonoscopy could be insufficient for trainees to gain competence and 80% of those indicated that ≥ 200 colonoscopies were needed. GEs (73.4%) were more likely than non-GEs (36.2%) to be of the opinion that the Conjoint Committee standard is insufficient to gain competence in colonoscopy (χ2-test = 16.97, P = 0.0001). The majority of trainers did not support training either nurses (73%) or GPs in colonoscopy (71%). Only 81 (estimated response rate 17.9%) surveys were received from GS trainees (72.1%), GE trainees (26.3%) and GP trainees (1.2%). The majority were males (75.9%), with a median age 32 years and who had trained in New South Wales (41.0%) or Victoria (30%). Overall, two-thirds (60.8%) of trainees indicated that they deemed the Conjoint Committee standard sufficient to gain competency in colonoscopy. Between specialties, 75.4% of GS trainees indicated that the Conjoint Committee standard for recognition of colonoscopy was sufficient to gain competence in colonoscopy compared to only 38.5% of GE trainees. Measures of competency assessed and recorded by trainees in logbooks centred mainly on caecal intubation (94.7-100%), complications (78.9-100%) and withdrawal time (51-76.2%). Trainees described limited access to colonoscopy training lists due to the time inefficiency of the apprenticeship model and perceived monopolisation of these by GEs and their trainees. Improvements to the current training model suggested by trainees included: more use of simulation, training tools, a United Kingdom (UK)-style training course, concentration on quality indicators, increased access to training lists, accreditation of trainers and interdisciplinary colonoscopy training. Implications for the NBCSP/QBCSP: The introduction of the NBCSP/QBCSP necessitates higher quality colonoscopy services if it is to achieve its ultimate goal of decreasing the incidence of morbidity and mortality associated with bowel cancer in Australia. This will be achieved under a new paradigm for colonoscopy training and implementation of evidence-based practice across the screening pathway and specifically targeting areas highlighted in this thesis. Recommendations for improvement of NBCSP/QBCSP effectiveness and efficiency include the following: 1. Implementation of NBCSP and QBCSP health promotion activities that target men, in particular, to increase FOBT screening uptake. 2. Improved colonoscopy training for trainees and refresher courses or retraining for existing proceduralists to improve completion rates (especially for female NBCSP/QBCSP participants), and polyp and adenoma detection and removal, including newer techniques to detect flat and depressed lesions. 3. Introduction of colonoscopy training initiatives for trainees that are aligned with NBCSP/QBCSP colonoscopy quality indicators, including measurement of training outcomes using objective quality indicators such as caecal intubation, withdrawal time, and adenoma detection rate. 4. Introduction of standardised, interdisciplinary colonoscopy training to reduce apparent differences between specialties with regard to compliance with guideline recommendations, completion rates, and quality of polypectomy. 5. Improved quality of colonoscopy training by adoption of a UK-style training program with centres of excellence, incorporating newer, more objective assessment methods, use of a variety of training tools such as simulation and rotations of trainees between metropolitan, rural, and public and private sector training facilities. 6. Incorporation of NHMRC guidelines into colonoscopy information systems to improve documentation, provide guideline recommendations at the point of care, use of gastroenterology nurse coordinators to facilitate compliance with guidelines and provision of guideline-based colonoscopy referral letters for GPs. 7. Provision of information and education about the NBCSP/QBCSP, bowel cancer risk factors, including family history and polyp surveillance guidelines, for participants, GPs and proceduralists. 8. Improved referral of NBCSP/QBCSP participants found to have a high-risk family history of bowel cancer to appropriate genetics services.
Resumo:
This collaborative event was organised to coincide with International celebrations by the International Council of Societies of Industrial Design (ICSID). The panel discussion involved industrial designers from a variety of backgrounds including academics, theorists and practitioners. Each panel member was given time to voice their opinion surrounding the theme of WIDD2010 "Industrial Design: Humane Solutions for a Resilient World". The discussion was then extended to the audience through active question and answer time. The panel included: * Professor Vesna Popovic FDIA - Queensland University of Technology * Adam Doyle, Studio Manager - Infinity Design Development * Scott Cox MDIA, Creative Director - Formwerx * Alexander Lotersztain, Director - Derlot * Philip Whiting FDIA, Design Convenor - QCA * Professor Tony Fry, Director Team D/E/S & QCA After this, the documentary by Gary Hewtsit "Objectified" was then screened (75 min).
Resumo:
In a critical review of the literature to assess the efficacy of monotherapy and subsequent combinant anticonvulsant therapy in the treatment of neonatal seizures, four studies were examined; three randomised control trials and one retrospective cohort study. Each study used phenobarbital for monotherapy with doses reaching a maximum of 40mg/kg. Anticonvulsant drugs used in conjunction with phenobarbitone for combinant therapy included midazolam, clonazepam, lorazepam, phenytoin and lignocaine. Each study used an electroencephalograph for seizure diagnosis and neonatal monitoring when determining therapy efficacy and final outcome assessments. Collectively the studies suggest neither monotherapy nor combinant therapy are entirely effective in seizure control. Monotherapy demonstrated a 29% - 50% success rate for complete seizure control whereas combinant therapy administered after the failure of monotherapy demonstrated a success rate of 43% - 100%. When these trials were combined the overall success for monotherapy was 44% (n = 34/78) and for combinant therapy 72% ( n = 56/78). Though the evidence was inconclusive, it would appear that combinant therapy is of greater benefit to infants unresponsive to monotherapy. Further research such as multi-site randomised controlled trials using standardised criteria and data collection are required within this specialised area.
Resumo:
Objective: The Brief Michigan Alcoholism Screening Test (bMAST) is a 10-item test derived from the 25-item Michigan Alcoholism Screening Test (MAST). It is widely used in the assessment of alcohol dependence. In the absence of previous validation studies, the principal aim of this study was to assess the validity and reliability of the bMAST as a measure of the severity of problem drinking. Method: There were 6,594 patients (4,854 men, 1,740 women) who had been referred for alcohol-use disorders to a hospital alcohol and drug service who voluntarily participated in this study. Results: An exploratory factor analysis defined a two-factor solution, consisting of Perception of Current Drinking and Drinking Consequences factors. Structural equation modeling confirmed that the fit of a nine-item, two-factor model was superior to the original one-factor model. Concurrent validity was assessed through simultaneous administration of the Alcohol Use Disorders Identification Test (AUDIT) and associations with alcohol consumption and clinically assessed features of alcohol dependence. The two-factor bMAST model showed moderate correlations with the AUDIT. The two-factor bMAST and AUDIT were similarly associated with quantity of alcohol consumption and clinically assessed dependence severity features. No differences were observed between the existing weighted scoring system and the proposed simple scoring system. Conclusions: In this study, both the existing bMAST total score and the two-factor model identified were as effective as the AUDIT in assessing problem drinking severity. There are additional advantages of employing the two-factor bMAST in the assessment and treatment planning of patients seeking treatment for alcohol-use disorders. (J. Stud. Alcohol Drugs 68: 771-779,2007)
Resumo:
Objectives: To assess the validity of the Waterlow screening tool in a cohort of internal medicine patients and to identify factors contributing to pressure injury. Design: Longitudinal cohort study Setting: A tertiary hospital in Brisbane, Australia Participants: 274 patients admitted through the Emergency Department or outpatient clinics and expected to remain in hospital for at least three days were included in the study. The mean age was 65.3 years. Interventions: Patients were screened on admission using the Waterlow screening tool. Every second day, their pressure ulcer status was monitored and recorded. Main outcome measures: Pressure ulcer incidence Results: Fifteen participants (5.5%) had an existing pressure ulcer and a further 12 (4.4%) developed a pressure ulcer during their hospital stay. Sensitivity of the Waterlow scale was 0.67, (95% CI: 0.35 to 0.88); specificity 0.79, (95% CI: 0.73 to 0.85); PPV 0.13, (95% CI: 0.07 to 0.24); NPV 0.98, (95% CI: 0.94 to 0.99). Conclusion: This study provides further evidence of the poor predictive validity of the Waterlow scale. A suitably powered randomised controlled trial is urgently needed to provide definitive evidence about the usefulness of the Waterlow scale compared with other screening tools and with clinical judgement.