965 resultados para Myocardial perfusion
Resumo:
Introdução – A cintigrafia de perfusão do miocárdio (CPM) é um dos exames complementares de diagnóstico mais indicados na patologia cardiovascular. A atividade extramiocárdica é um problema recorrente na aquisição e avaliação da imagem. Parâmetros como o radiofármaco (RF) administrado, o tipo de esforço, a ingestão de alimentos, o posicionamento e o processamento de imagem influenciam a atividade extramiocárdica na CPM. O objetivo deste estudo é identificar o protocolo da CPM a nível nacional e avaliar a percentagem de repetições das aquisições provocadas por este problema. Metodologia – Para a realização deste estudo, a população selecionada foram os Serviços de Medicina Nuclear (SMN) em Portugal Continental. Foram analisados 15 questionários, respondidos pelos Técnicos Coordenadores dos vários SMN. Foi realizada a associação do comportamento das variáveis, através da estatística descritiva e do Coeficiente de Correlação de Spearman. Resultados – A percentagem de repetições é menor com o uso da 99mTecnécio(Tc)-Tetrofosmina, aquisição de imagens tardias, ingestão de diversos alimentos (água, leite, sumo, pão com manteiga) e com a correção de atenuação. Conclusão – Os resultados obtidos demonstram que a maioria das soluções aplicadas nos SMN resultam numa diminuição das repetições.
Resumo:
Introdução – Os estudos Gated – Single Photon Emission Computed Tomography (SPECT) são uma das técnicas de imagiologia cardíaca que mais evoluiu nas últimas décadas. Para a análise das imagens obtidas, a utilização de softwares de quantificação leva a um aumento da reprodutibilidade e exatidão das interpretações. O objetivo deste estudo consiste em avaliar, em estudos Gated-SPECT, a variabilidade intra e interoperador de parâmetros quantitativos de função e perfusão do miocárdio, obtidos com os softwares Quantitative Gated SPECT (QGS) e Quantitative Perfusion SPECT (QPS). Material e métodos – Recorreu-se a uma amostra não probabilística por conveniência de 52 pacientes, que realizaram estudos Gated-SPECT do miocárdio por razões clínicas e que integravam a base de dados da estação de processamento da Xeleris da ESTeSL. Os cinquenta e dois estudos foram divididos em dois grupos distintos: Grupo I (GI) de 17 pacientes com imagens com perfusão do miocárdio normal; Grupo II (GII) de 35 pacientes que apresentavam defeito de perfusão nas imagens Gated-SPECT. Todos os estudos foram processados 5 vezes por 4 operadores independentes (com experiência de 3 anos em Serviços de Medicina Nuclear com casuística média de 15 exames/semana de estudos Gated-SPECT). Para a avaliação da variabilidade intra e interoperador foi utilizado o teste estatístico de Friedman, considerando α=0,01. Resultados e discussão – Para todos os parâmetros avaliados, os respectivos valores de p não traduziram diferenças estatisticamente significativas (p>α). Assim, não foi verificada variabilidade intra ou interoperador significativa no processamento dos estudos Gated-SPECT do miocárdio. Conclusão – Os softwares QGS e QPS são reprodutíveis na quantificação dos parâmetros de função e perfusão avaliados, não existindo variabilidade introduzida pelo operador.
Resumo:
Myocardial Perfusion Gated Single Photon Emission Tomography (Gated-SPET) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV). The purpose of this study is to evaluate the influence of the total number of counts acquired from myocardium, in the calculation of myocardial functional parameters using routine software procedures. Methods: Gated-SPET studies were simulated using Monte Carlo GATE package and NURBS phantom. Simulated data were reconstructed and processed using the commercial software package Quantitative Gated-SPECT. The Bland-Altman and Mann-Whitney-Wilcoxon tests were used to analyze the influence of the number of total counts in the calculation of LV myocardium functional parameters. Results: In studies simulated with 3MBq in the myocardium there were significant differences in the functional parameters: Left ventricular ejection fraction (LVEF), end-systolic volume (ESV), Motility and Thickness; between studies acquired with 15s/projection and 30s/projection. Simulations with 4.2MBq show significant differences in LVEF, end-diastolic volume (EDV) and Thickness. Meanwhile in the simulations with 5.4MBq and 8.4MBq the differences were statistically significant for Motility and Thickness. Conclusion: The total number of counts per simulation doesn't significantly interfere with the determination of Gated-SPET functional parameters using the administered average activity of 450MBq to 5.4MBq in myocardium.
Resumo:
Mestrado em Medicina Nuclear - Ramo de especialização: Radiofarmácia
Resumo:
Myocardial perfusion gated-single photon emission computed tomography (gated-SPECT) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. The aim of this study is to analyze the influence of counts/pixel and concomitantly the total counts in the myocardium for the calculation of myocardial functional parameters. Material and methods: Gated-SPECT studies were performed using a Monte Carlo GATE simulation package and the NCAT phantom. The simulations of these studies use the radiopharmaceutical 99mTc-labeled tracers (250, 350, 450 and 680MBq) for standard patient types, effectively corresponding to the following activities of myocardium: 3, 4.2, 5.4-8.2MBq. All studies were simulated using 15 and 30s/projection. The simulated data were reconstructed and processed by quantitative-gated-SPECT software, and the analysis of functional parameters in gated-SPECT images was done by using Bland-Altman test and Mann-Whitney-Wilcoxon test. Results: In studies simulated using different times (15 and 30s/projection), it was noted that for the activities for full body: 250 and 350MBq, there were statistically significant differences in parameters Motility and Thickness. For the left ventricular ejection fraction (LVEF), end-systolic volume (ESV) it was only for 250MBq, and 350MBq in the end-diastolic volume (EDV), while the simulated studies with 450 and 680MBq showed no statistically significant differences for global functional parameters: LVEF, EDV and ESV. Conclusion: The number of counts/pixel and, concomitantly, the total counts per simulation do not significantly interfere with the determination of gated-SPECT functional parameters, when using the administered average activity of 450MBq, corresponding to the 5.4MBq of the myocardium, for standard patient types.
Resumo:
Introduction: multimodality environment; requirement for greater understanding of the imaging technologies used, the limitations of these technologies, and how to best interpret the results; dose optimization; introduction of new techniques; current practice and best practice; incidental findings, in low-dose CT images obtained as part of the hybrid imaging process, are an increasing phenomenon with advancing CT technology; resultant ethical and medico-legal dilemmas; understanding limitations of these procedures important when reporting images and recommending follow-up; free-response observer performance study was used to evaluate lesion detection in low-dose CT images obtained during attenuation correction acquisitions for myocardial perfusion imaging, on two hybrid imaging systems.
Resumo:
The acquisition of a Myocardial Perfusion image (MPI) is of great importance for the diagnosis of the coronary artery disease, since it allows to evaluate which areas of the heart aren’t being properly perfused, in rest and stress situations. This exam is greatly influenced by photon attenuation which creates image artifacts and affects quantification. The acquisition of a Computerized Tomography (CT) image makes it possible to get an atomic images which can be used to perform high-quality attenuation corrections of the radiopharmaceutical distribution, in the MPI image. Studies show that by using hybrid imaging to perform diagnosis of the coronary artery disease, there is an increase on the specificity when evaluating the perfusion of the right coronary artery (RCA). Using an iterative algorithm with a resolution recovery software for the reconstruction, which balances the image quality, the administered activity and the scanning time, we aim to evaluate the influence of attenuation correction on the MPI image and the outcome in perfusion quantification and imaging quality.
Resumo:
Introdução – A cintigrafia de perfusão do miocárdio (CPM) desempenha um importante papel no diagnóstico, avaliação e seguimento de pacientes com doença arterial coronária, sendo o seu processamento realizado maioritariamente de forma semiautomática. Uma vez que o desempenho dos técnicos de medicina nuclear (TMN) pode ser afetado por fatores individuais e ambientais, diferentes profissionais que processem os mesmos dados poderão obter diferentes estimativas dos parâmetros quantitativos (PQ). Objetivo – Avaliar a influência da experiência profissional e da função visual no processamento semiautomático da CPM. Analisar a variabilidade intra e interoperador na determinação dos PQ funcionais e de perfusão. Metodologia – Selecionou-se uma amostra de 20 TMN divididos em dois grupos, de acordo com a sua experiência no software Quantitative Gated SPECTTM: Grupo A (GA) – TMN ≥600h de experiência e Grupo B (GB) – TMN sem experiência. Submeteram-se os TMN a uma avaliação ortóptica e ao processamento de 21 CPM, cinco vezes, não consecutivas. Considerou-se uma visão alterada quando pelo menos um parâmetro da função visual se encontrava anormal. Para avaliar a repetibilidade e a reprodutibilidade recorreu-se à determinação dos coeficientes de variação, %. Na comparação dos PQ entre operadores, e para a análise do desempenho entre o GA e GB, aplicou-se o Teste de Friedman e de Wilcoxon, respetivamente, considerando o processamento das mesmas CPM. Para a comparação de TMN com visão normal e alterada na determinação dos PQ utilizou-se o Teste Mann-Whitney e para avaliar a influência da visão para cada PQ recorreu-se ao coeficiente de associação ETA. Diferenças estatisticamente significativas foram assumidas ao nível de significância de 5%. Resultados e Discussão – Verificou-se uma reduzida variabilidade intra (<6,59%) e inter (<5,07%) operador. O GB demonstrou ser o mais discrepante na determinação dos PQ, sendo a parede septal (PS) o único PQ que apresentou diferenças estatisticamente significativas (zw=-2,051, p=0,040), em detrimento do GA. No que se refere à influência da função visual foram detetadas diferenças estatisticamente significativas apenas na fração de ejeção do ventrículo esquerdo (FEVE) (U=11,5, p=0,012) entre TMN com visão normal e alterada, contribuindo a visão em 33,99% para a sua variação. Denotaram-se mais diferenças nos PQ obtidos em TMN que apresentam uma maior incidência de sintomatologia ocular e uma visão binocular diminuída. A FEVE demonstrou ser o parâmetro mais consistente entre operadores (1,86%). Conclusão – A CPM apresenta-se como uma técnica repetível e reprodutível, independente do operador. Verificou-se influência da experiência profissional e da função visual no processamento semiautomático da CPM, nos PQ PS e FEVE, respetivamente.
Resumo:
A par das patologias oncológicas, as doenças do foro cardíaco, em particular a doença arterial coronária, são uma das principais causas de morte nos países industrializados, devido sobretudo, à grande incidência de enfartes do miocárdio. Uma das formas de diagnóstico e avaliação desta condição passa pela obtenção de imagens de perfusão miocárdica com radionuclídeos, realizada por Tomografia por Emissão de Positrões (PET). As soluções injectáveis de [15O]-H2O, [82Rb] e [13N]-NH3 são as mais utilizadas neste tipo de exame clínico. No Instituto de Ciências Nucleares Aplicadas à Saúde (ICNAS), a existência de um ciclotrão tem permitido a produção de uma variedade de radiofármacos, com aplicações em neurologia, oncologia e cardiologia. Recentemente, surgiu a oportunidade de iniciar exames clínicos com [13N]-NH3 para avaliação da perfusão miocárdica. É neste âmbito que surge a oportunidade do presente trabalho, pois antes da sua utilização clínica é necessário realizar a optimização da produção e a validação de todo o processo segundo as normas de Boas Práticas Radiofarmacêuticas. Após uma fase de optimização do processo, procedeu-se à avaliação dos parâmetros físico-químicos e biológicos da preparação de [13N]-NH3, de acordo com as indicações da Farmacopeia Europeia (Ph. Eur.) 8.2. De acordo com as normas farmacêuticas, foram realizados 3 lotes de produção consecutivos para validação da produção de [13N]-NH3. Os resultados mostraram um produto final límpido e ausente de cor, com valores de pH dentro do limite especificado, isto é, entre 4,5 e 8,5. A pureza química das amostras foi verificada, uma vez que relativamente ao teste colorimétrico, a tonalidade da cor da solução de [13N]-NH3 não era mais intensa que a solução de referência. As preparações foram identificadas como sendo [13N]-NH3, através dos resultados obtidos por cromatografia iónica, espectrometria de radiação gama e tempo de semi-vida. Por examinação do cromatograma obtido com a solução a ser testada, observou-se que o pico principal possuia um tempo de retenção aproximadamente igual ao pico do cromatograma obtido para a solução de referência. Além disso, o espectro de radiação gama mostrou um pico de energia 0,511 MeV e um outro adicional de 1,022 MeV para os fotões gama, característico de radionuclídeos emissores de positrões. O tempo de semi-vida manteve-se dentro do intervalo indicado, entre 9 e 11 minutos. Verificou-se, igualmente, a pureza radioquímica das amostras, correspondendo um mínimo de 99% da radioactividade total ao [13N], bem como a pureza radionuclídica, observando-se uma percentagem de impurezas inferiores a 1%, 2h após o fim da síntese. Os testes realizados para verificação da esterilidade e determinação da presença de endotoxinas bacterianas nas preparações de [13N]-NH3 apresentaram-se negativos.Os resultados obtidos contribuem, assim, para a validação do método para a produção de [13N]-NH3, uma vez que cumprem os requisitos especificados nas normas europeias, indicando a obtenção de um produto seguro e com a qualidade necessária para ser administrado em pacientes para avaliação da perfusão cardíaca por PET.
Resumo:
OBJECTIVE: To assess the frequency and severity of the anomalous origin of the left coronary artery (ALCA) from the pulmonary artery (PA). DESIGN OF THE STUDY: Prospective study of case series between March 1991 and December 1994. SETTING: Referral-based Paediatric Cardiology Department of a Tertiary Care Center. PATIENTS AND METHODS: Five consecutive patients (pts) with anomalous origin of the LCA from the PA; there were three infants aged 4 months and two children one 8 year and one 9 year old. There were three girls and two boys. All pts had clinical and 2D-echo and Doppler investigation prior to cardiac catheterization (CC). Indication for CC was based in the association of symptoms and signs of myocarditis or dilated cardiomyopathy of acute or subacute onset and electrocardiographic (ECG) signs of ischemia in infants. In older patients (pts) diagnosis was suspected mainly from ECG. During CC in all pts, aortograms and when necessary selective coronary angiograms were performed. Surgical correction was performed in all children. In two pts stress exercise ECG and stress Thallium studies before and after surgery were performed. RESULTS: two pts had "adult" an three had "infantile" type of ALCA from the PA. CC was performed and diagnosis was confirmed at surgery in all cases. In one child, correct diagnosis was made by ECO prior to CC and in one case LCA to PA fistula was suspected on Colour-Doppler study. No complications were attributed to CC. Several types of surgery were performed: reimplantation of the ALCA from the PA to the aorta (three pts); tunnel connection of the aorta to the ALCA via the PA (one pt) and left internal mammary to LCA anastomosis (one pt). Two infants died intraoperatively due to extensive myocardial infarction and poor left ventricular function. All the three survivors are asymptomatic after a mean follow up of 34 months. Two oldest pts are currently in New York Heart Association functional class I with normal ECG and improved myocardial perfusion on Thallium scan despite almost total occlusion of LCA at the site of implantation in the aorta as diagnosed on coronary angiogram. CONCLUSIONS: ALCA from PA is associated with major morbidity and mortality. Diagnosis should be suspected in pts with unexplained myocardial ischemia on ECG and even more if it is associated to clinical signs of dilated cardiomyopathy or myocarditis. Careful assessment on ECO and pulsed Doppler and colour flow mapping should make the diagnosis in most cases. Although surgery can be performed based only on ECO diagnosis, we strongly advise for angiography in all cases as in our experience there are false negative diagnosis by ECO. Preoperative Thallium studies can be useful for the selection of the type of surgery as pts with very little viable myocardium will not survive the establishment of a direct systemic to coronary blood flow and may be candidates for heart transplantation.
Resumo:
RESUMO: Este trabalho tentou contribuir para a caracterização da fisiopatologia da microcirculação coronária em diferentes formas de patologia com o auxílio da ecocardiografia transtorácica. Com a aplicação da ecocardiografia Doppler transtorácica foi efectuado o estudo da reserva coronária da artéria descendente anterior e com a ecocardiografia de contraste do miocárdio foram analisados parâmetros de perfusão do miocárdio como a velocidade da microcirculação coronária, o volume de sangue miocárdico e a reserva de fluxo miocárdico. Estas técnicas foram utilizadas em diferentes situações fisiopatológicas com particular interesse na hipertrofia ventricular esquerda de diferentes etiologias como a hipertensão arterial, estenose aórtica e cardiomiopatia hipertrófica. Também na diabetes mellitus tipo 2 e na doença coronária aterosclerótica, estudámos as alterações da microcirculação coronária. Com a mesma técnica de ecocardiografia de contraste do miocárdio foi analisada a perfusão do miocárdio num modelo experimental animal sujeito a uma dieta aterogénica. Além das conclusões específicas em relação a cada um dos trabalhos efectuados há a referir como conclusões gerais a sua fácil aplicabilidade e exequibilidade em âmbito clínico, a sua reprodutibilidade e precisão. Quando comparadas com técnicas consideradas de referência mostraram resultados com significativa correlação estatística. Em todos os doentes e nos grupos controle foi possível comprovar e quantificar o gradiente de perfusão transmural em repouso e durante a acção de stress vasodilatador, relevando a importância da perfusão sub-endocárdica na função do ventrículo esquerdo. O estudo da microcirculação coronária no grupo de doentes com hipertrofia ventricular esquerda revelou que no grupo com hipertensão arterial existe disfunção da microcirculação coronária ainda antes de se observar aumento de massa do ventrículo esquerdo, e que esta disfunção é diferente em função da geometria ventricular. Nos doentes com estenose aórtica foi demonstrado que além da disfunção da microcirculação coronária, explicada pelo fenómeno de hipertrofia, existe outro componente extrínseco que depois de corrigido através de cirurgia de substituição valvular, conduziu a uma parcial normalização dos valores de reserva coronária. Na cardiomiopatia hipertrófica observou-se uma grande heterogeneidade de perfusão transmural e foi documentado, em imagens de ecocardiografia de contraste do miocárdio e após análise paramétrica, a ausência de perfusão do miocárdio na região sub-endocárdica durante o stress vasodilatador de reserva coronária diminuídos em fases precoces de evolução da doença. Foi demonstrado que a reserva coronária na DM2 em fases mais avançadas estava significativamente diminuída. Descrevemos também em doentes com DM2 e sem doença coronária angiográfica a existência de disfunção da microcirculação coronária. Durante o stress vasodilatador, observámos e documentámos neste grupo de doentes, a existência de defeitos de perfusão transitórios ou de diminuição da velocidade da microcirculação coronária. No grupo de doentes com doença coronária confirmámos o interesse da avaliação da reserva coronária após intervenção percutânea na definição de prognóstico pós EAM, em termos de recuperação funcional do ventrículo esquerdo. Em doentes com BCRE e de difícil estratificação de risco, foi possível calcular o valor de reserva coronária e estratificar o risco de doença coronária. Num modelo experimental animal demonstrámos a exequibilidade da técnica de ECM, e verificámos que nessas condições experimentais, uma sobrecarga aterogénica na dieta, ao fim de 6 semanas, comprometia severamente a reserva coronária. Estes resultados foram parcialmente reversíveis quando à dieta foi adicionada uma estatina. Estas técnicas pela sua não invasibilidade, fácil acesso, repetibilidade e inocuidade perspectivam-se de grande utilidade na caracterização de doentes com disfunção da microcirculação coronária, nas diferentes áreas de diagnóstico, terapêutica e prevenção. A possibilidade de adaptar a técnica em modelos experimentais animais também nos parece poder vir a ter grande utilidade em investigação.----------------ABSTRACT: This work is intended to be a contribution to the study of coronary microcirculation applying new echocardiographic techniques as transthoracic Doppler echocardiography of coronary arteries and myocardial contrast echocardiography. Coronary flow reserve may be assessed by transthoracic Doppler echocardiography, and important functional microcirculation parameters as microcirculation flow velocity, myocardial blood volume and myocardial flow reserve may be evaluated through myocardial contrast echocardiography. Microcirculation was analysed in different pathophysiological settings. We addressed situations with increased left ventricular mass as systemic arterial hypertension, aortic stenosis and hypertrophic cardiomyopathy. Also coronary microcirculation was studied in type 2 Diabetes and in different clinical forms of atherosclerotic coronary artery disease. Specific and detailed conclusions were withdrawn from each experimental work. In the overall it was concluded that these two techniques were important tools to easily assess specific pathophysiological information about coronary microcirculation at bed side which would be difficult to get through other techniques. When compared with gold standard techniques, similar sensibility and specificity was found. Because of their better temporal and spatial resolution it was possible to analyse the importance of transmural perfusion gradients, both in basal and during vasodilatation, and their relation to ischemia, and mechanical wall kinetics, as wall thickening and motion. Coronary microcirculation dysfunction was found in systemic arterial hypertension early evolution stages, also related to different left ventricular geometric patterns. Different etiopathogenical explanations for aortic stenosis coronary microcirculation dysfunction were analysed and compared after aortic valve replacement. Transmural myocardial perfusion heterogeneity pattern was observed in hypertrophic cardiomyopathy which was aggravated during adenosine challenge. Coronary microcirculation dysfunction was diagnosed in type 2 diabetes both with coronary artery disease and with normal angiographic coronary arteries. Dynamic transitory subendocardial perfusion defects with adenosine vasodilatation were visualized in these patients.In patients with left branch block, transthoracic Doppler echocardiography was able to suggest a coronary reserve cut-off value for risk stratification. Also it was possible with this technique to calculate coronary flow reserve and predict restenosis after PTCA Again, in an experimental animal model, applying myocardial contrast echocardiography technique it was possible to study the consequences of an atherogenic diet and statins action on the coronary microcirculation function. Because these techniques are easily performed at bed side, are harmless, use no ionizing radiation and because of their repeatability, reproducibility and accuracythey are promissory tools to assess coronary microcirculation. Both in clinic and research areas these techniques will probably have a role in clinical diagnosis, prevention and therapeutically decision.
Resumo:
Abstract: Scorpion stings are currently the leading cause of venom-related injury to humans in Brazil and are a significant public health problem globally. Only scorpions of the Tityus genus are of medical importance in Brazil, and Tityus serrulatus is responsible for the most serious envenomations and deaths. The toxic effects of scorpion envenomation are due to a massive release of sympathetic and parasympathetic neurotransmitters; the severity is related to cardiac and hemodynamic changes, with cardiogenic shock and pulmonary edema contributing to the main causes of death. The pathophysiology of cardiac involvement has been discussed for decades and has been attributed to adrenergic discharge and a possible toxic effect of venom on the myocardium, while acute pulmonary edema may have a cardiogenic and/or non-cardiogenic origin. Currently, the clinical data point to catecholamine excess as the cause for reversible scorpion cardiomyopathy . These data include electrocardiographic changes, profiling of cardiac enzymes and troponin I, echocardiographic data with global or regional left ventricle dysfunction, and myocardial perfusion alterations compatible with spasm in the coronary microcirculation. Furthermore, recent data on cardiac magnetic resonance imaging findings, which are similar to those observed for stress-induced cardiomyopathy, have also been linked to catecholamine excess. The efficiency of antivenom serum treatment is controversial in the literature. Our experience in Brazil is that the management of patients with systemic manifestations of scorpion stings is based on three approaches, all of which are extremely important. These include symptomatic treatment, antivenom serum, and cardiorespiratory support.
Resumo:
OBJECTIVE: To test the feasibility, safety and accuracy of the adenosine protocol in the study of myocardial perfusion with microbubbles contrast echocardiography. METHODS: 81 pts (64 male, 60+11 years) were submitted to contrast echocardiography with PESDA (sonicated solution of albumin 20%-1ml, dextrose 5%-12ml and deca-fluorobutane gas-8ml) to study the myocardial perfusion at rest and after bolus injection of adenosine (6 to 18mg) and to coronary angiography within 1 month each other. For each patient 3 left ventricle perfusion beds were considered (total of 243 territories). 208 territories were analyzed and 35 territories were excluded. PESDA was continuously infused (1-2ml/min), titrated for best myocardial contrast. Triggered (1:1) second harmonic imaging was used. RESULTS: Coronary angiography showed 70 flow limiting (> 75%) lesions and 138 no flow limiting lesions. At rest an obvious myocardium contrast enhancement was seen in at least 1 segment of a territory in all patients. After adenosine injection an unquestionable further increase in myocardial contrast was observed in 136 territories (99%) related to no flow limiting lesions, lasting < 10 s, and a myocardial perfusion defect was detected in 68 territories (97%) related to flow limiting lesions. It was observed only 4 false results. There were no serious complications. CONCLUSION: Myocardial perfusion study with PESDA and adenosine protocol is a practical, safe and accurate method to analyze the coronary flow reserve.
Resumo:
OBJECTIVE: To investigate the role of hemodynamic changes occurring during acute MI in subsequent fibrosis deposition within non-MI. METHODS: By using the rat model of MI, 3 groups of 7 rats each [sham, SMI (MI <30%), and LMI (MI >30%)] were compared. Systemic and left ventricular (LV) hemodynamics were recorded 10 minutes before and after coronary artery ligature. Collagen volume fraction (CVF) was calculated in picrosirius red-stained heart tissue sections 4 weeks later. RESULTS: Before surgery, all hemodynamic variables were comparable among groups. After surgery, LV end-diastolic pressure increased and coronary driving pressure decreased significantly in the LMI compared with the sham group. LV dP/dt max and dP/dt min of both the SMI and LMI groups were statistically different from those of the sham group. CVF within non-MI interventricular septum and right ventricle did not differ between each MI group and the sham group. Otherwise, subendocardial (SE) CVF was statistically greater in the LMI group. SE CVF correlated negatively with post-MI systemic blood pressure and coronary driving pressure, and positively with post-MI LV dP/dt min. Stepwise regression analysis identified post-MI coronary driving pressure as an independent predictor of SE CVF. CONCLUSION: LV remodeling in rats with MI is characterized by predominant SE collagen deposition in non-MI and results from a reduction in myocardial perfusion pressure occurring early on in the setting of MI.
Resumo:
We report a rare case of anomalous origin of the left coronary artery from the pulmonary trunk in a 45-year-old woman. The approach and technique used for selective catheterization of an anomalous left coronary artery arising from the pulmonary trunk are described. Six years after diagnosis, echocardiography showed left ventricular disfunction, and surgical treatment was indicated again. The origin of the left coronary artery from the pulmonary trunk was closed, and the postoperative period was uneventful, with recovery of left ventricular function and disappearance of ischemic features on stress myocardial perfusion imaging with 99m Tc-sestamibi, performed 4 weeks after surgery.