998 resultados para Mesoscopic samples


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A combined data matrix consisting of high performance liquid chromatography–diode array detector (HPLC–DAD) and inductively coupled plasma-mass spectrometry (ICP-MS) measurements of samples from the plant roots of the Cortex moutan (CM), produced much better classification and prediction results in comparison with those obtained from either of the individual data sets. The HPLC peaks (organic components) of the CM samples, and the ICP-MS measurements (trace metal elements) were investigated with the use of principal component analysis (PCA) and the linear discriminant analysis (LDA) methods of data analysis; essentially, qualitative results suggested that discrimination of the CM samples from three different provinces was possible with the combined matrix producing best results. Another three methods, K-nearest neighbor (KNN), back-propagation artificial neural network (BP-ANN) and least squares support vector machines (LS-SVM) were applied for the classification and prediction of the samples. Again, the combined data matrix analyzed by the KNN method produced best results (100% correct; prediction set data). Additionally, multiple linear regression (MLR) was utilized to explore any relationship between the organic constituents and the metal elements of the CM samples; the extracted linear regression equations showed that the essential metals as well as some metallic pollutants were related to the organic compounds on the basis of their concentrations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel, highly selective resonance light scattering (RLS) method was researched and developed for the analysis of phenol in different types of industrial water. An important aspect of the method involved the use of graphene quantum dots (GQDs), which were initially obtained from the pyrolysis of citric acid dissolved in aqueous solutions. The GQDs in the presence of horseradish peroxidase (HRP) and H2O2 were found to react quantitatively with phenol such that the RLS spectral band (310 nm) was quantitatively enhanced as a consequence of the interaction between the GQDs and the quinone formed in the above reaction. It was demonstrated that the novel analytical method had better selectivity and sensitivity for the determination of phenol in water as compared to other analytical methods found in the literature. Thus, trace amounts of phenol were detected over the linear ranges of 6.00×10−8–2.16×10−6 M and 2.40×10−6–2.88×10−5 M with a detection limit of 2.20×10−8 M. In addition, three different spiked waste water samples and two untreated lake water samples were analysed for phenol. Satisfactory results were obtained with the use of the novel, sensitive and rapid RLS method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statistical comparison of oil samples is an integral part of oil spill identification, which deals with the process of linking an oil spill with its source of origin. In current practice, a frequentist hypothesis test is often used to evaluate evidence in support of a match between a spill and a source sample. As frequentist tests are only able to evaluate evidence against a hypothesis but not in support of it, we argue that this leads to unsound statistical reasoning. Moreover, currently only verbal conclusions on a very coarse scale can be made about the match between two samples, whereas a finer quantitative assessment would often be preferred. To address these issues, we propose a Bayesian predictive approach for evaluating the similarity between the chemical compositions of two oil samples. We derive the underlying statistical model from some basic assumptions on modeling assays in analytical chemistry, and to further facilitate and improve numerical evaluations, we develop analytical expressions for the key elements of Bayesian inference for this model. The approach is illustrated with both simulated and real data and is shown to have appealing properties in comparison with both standard frequentist and Bayesian approaches

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel near-infrared spectroscopy (NIRS) method has been researched and developed for the simultaneous analyses of the chemical components and associated properties of mint (Mentha haplocalyx Briq.) tea samples. The common analytes were: total polysaccharide content, total flavonoid content, total phenolic content, and total antioxidant activity. To resolve the NIRS data matrix for such analyses, least squares support vector machines was found to be the best chemometrics method for prediction, although it was closely followed by the radial basis function/partial least squares model. Interestingly, the commonly used partial least squares was unsatisfactory in this case. Additionally, principal component analysis and hierarchical cluster analysis were able to distinguish the mint samples according to their four geographical provinces of origin, and this was further facilitated with the use of the chemometrics classification methods-K-nearest neighbors, linear discriminant analysis, and partial least squares discriminant analysis. In general, given the potential savings with sampling and analysis time as well as with the costs of special analytical reagents required for the standard individual methods, NIRS offered a very attractive alternative for the simultaneous analysis of mint samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple one-step electrodeposition method was used to construct a glassy carbon electrode (GCE), which has been modified with Cu doped gold nanoparticles (GNPs), i.e. a Cu@AuNPs/GCE. This electrode was characterized with the use of scanning electron microscopy (SEM) and X-ray diffraction (XRD) techniques. The eugenol was electrocatalytically oxidized at the Cu@AuNPs/GCE. At this electrode, in comparison with the behavior at the GCE alone, the corresponding oxidation peak current was enhanced and the shift of the oxidation potentials to lower values was observed. Electrochemical behavior of eugenol at the Cu@AuNPs/GCE was investigated with the use of the cyclic voltammetry (CV) technique, and additionally, in order to confirm the electrochemical reaction mechanism for o-methoxy phenols, CVs for catechol, guaiacol and vanillin were investigated consecutively. Based on this work, an electrochemical reaction mechanism for o-methoxy phenols was suggested, and in addition, the above Cu@AuNPs/GCE was successfully employed for the analysis of eugenol in food samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An important uncertainty when estimating per capita consumption of, for example, illicit drugs by means of wastewater analysis (sometimes referred to as “sewage epidemiology”) relates to the size and variability of the de facto population in the catchment of interest. In the absence of a day-specific direct population count any indirect surrogate model to estimate population size lacks a standard to assess associated uncertainties. Therefore, the objective of this study was to collect wastewater samples at a unique opportunity, that is, on a census day, as a basis for a model to estimate the number of people contributing to a given wastewater sample. Mass loads for a wide range of pharmaceuticals and personal care products were quantified in influents of ten sewage treatment plants (STP) serving populations ranging from approximately 3500 to 500 000 people. Separate linear models for population size were estimated with the mass loads of the different chemical as the explanatory variable: 14 chemicals showed good, linear relationships, with highest correlations for acesulfame and gabapentin. De facto population was then estimated through Bayesian inference, by updating the population size provided by STP staff (prior knowledge) with measured chemical mass loads. Cross validation showed that large populations can be estimated fairly accurately with a few chemical mass loads quantified from 24-h composite samples. In contrast, the prior knowledge for small population sizes cannot be improved substantially despite the information of multiple chemical mass loads. In the future, observations other than chemical mass loads may improve this deficit, since Bayesian inference allows including any kind of information relating to population size.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Giant Cell Arteritis (GCA) is the most common vasculitis affecting the elderly. Archived formalin-fixed paraffin-embedded (FFPE) temporal artery biopsy (TAB) specimens potentially represent a valuable resource for large-scale genetic analysis of this disease. FFPE TAB samples were obtained from 12 patients with GCA. Extracted TAB DNA was assessed by real time PCR before restoration using the Illumina HD FFPE Restore Kit. Paired FFPE-blood samples were genotyped on the Illumina OmniExpress FFPE microarray. The FFPE samples that passed stringent quality control measures had a mean genotyping success of >97%. When compared with their matching peripheral blood DNA, the mean discordant heterozygote and homozygote single nucleotide polymorphisms calls were 0.0028 and 0.0003, respectively, which is within the accepted tolerance of reproducibility. This work demonstrates that it is possible to successfully obtain high-quality microarray-based genotypes FFPE TAB samples and that this data is similar to that obtained from peripheral blood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most genome-wide association studies to date have been performed in populations of European descent, but there is increasing interest in expanding these studies to other populations. The performance of genotyping chips in Asian populations is not well established. Therefore, we sought to test the performance of widely used fixed-marker, genome-wide association studies chips in the Han Chinese population. Non-HapMap Chinese samples (n = 396) were genotyped using the Illumina OmniExpress and Affymetrix 6.0 platforms, whereas a subset also were genotyped using the Immunochip. Genotyped markers from the Affymetrix 6.0 and Illumina OmniExpress were used for full genome imputation based on the HapMap 2 JPT+CHB (Japanese from Tokyo, Japan and Chinese from Beijing, China) reference panel. The concordance between markers genotypes for the three platforms was very high whether directly genotyped or genotyped and imputed single nucleotide polymorphisms (SNPs; .99.8% for directly genotyped and .99.5% for genotyped and imputed SNPs, respectively) were compared. The OmniExpress chip data enabled more SNPs to be imputed, particularly SNPs with minor allele frequency .5%. The OmniExpress chip achieved better coverage of HapMap SNPs than the Affymetrix 6.0 chip (73.6% vs. 65.9%, respectively, for minor allele frequency .5%). The Affymetrix 6.0 and Illumina OmniExpress chip have similar genotyping accuracy and provide similar accuracy of imputed SNPs. The OmniExpress chip however provides better coverage of Asian HapMap SNPs, although its coverage of HapMap SNPs is moderate. © 2013 Jiang et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental studies of Bi heteroepitaxy on Si(001) have recently uncovered a self-organised nanoline motif which has no detectable width dispersion. The Bi lines can be grown with an aspect ratio that is greater than 350 : 1. This paper describes a study of the nanoline geometry and electronic structure using a combination of scanning tunneling microscopy (STM) and ab initio theoretical methods. In particular, the effect that the lines have on Si(001) surface structure at large length scales, l > 100 nm, is studied. It has been found that Bi line growth on surfaces that have regularly spaced single height steps results in a 'preferred' domain orientation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doppler weather radars with fast scanning rates must estimate spectral moments based on a small number of echo samples. This paper concerns the estimation of mean Doppler velocity in a coherent radar using a short complex time series. Specific results are presented based on 16 samples. A wide range of signal-to-noise ratios are considered, and attention is given to ease of implementation. It is shown that FFT estimators fare poorly in low SNR and/or high spectrum-width situations. Several variants of a vector pulse-pair processor are postulated and an algorithm is developed for the resolution of phase angle ambiguity. This processor is found to be better than conventional processors at very low SNR values. A feasible approximation to the maximum entropy estimator is derived as well as a technique utilizing the maximization of the periodogram. It is found that a vector pulse-pair processor operating with four lags for clear air observation and a single lag (pulse-pair mode) for storm observation may be a good way to estimate Doppler velocities over the entire gamut of weather phenomena.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper considers the one-sample sign test for data obtained from general ranked set sampling when the number of observations for each rank are not necessarily the same, and proposes a weighted sign test because observations with different ranks are not identically distributed. The optimal weight for each observation is distribution free and only depends on its associated rank. It is shown analytically that (1) the weighted version always improves the Pitman efficiency for all distributions; and (2) the optimal design is to select the median from each ranked set.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential for large-scale use of a sensitive real time reverse transcription polymerase chain reaction (RT-PCR) assay was evaluated for the detection of Tomato spotted wilt virus (TSWV) in single and bulked leaf samples by comparing its sensitivity with that of DAS-ELISA. Using total RNA extracted with RNeasy® or leaf soak methods, real time RT-PCR detected TSWV in all infected samples collected from 16 horticultural crop species (including flowers, herbs and vegetables), two arable crop species, and four weed species by both assays. In samples in which DAS-ELISA had previously detected TSWV, real time RT-PCR was effective at detecting it in leaf tissues of all 22 plant species tested at a wide range of concentrations. Bulk samples required more robust and extensive extraction methods with real time RT-PCR, but it generally detected one infected sample in 1000 uninfected ones. By contrast, ELISA was less sensitive when used to test bulked samples, once detecting up to 1 infected in 800 samples with pepper but never detecting more than 1 infected in 200 samples in tomato and lettuce. It was also less reliable than real time RT-PCR when used to test samples from parts of the leaf where the virus concentration was low. The genetic variability among Australian isolates of TSWV was small. Direct sequencing of a 587 bp region of the nucleoprotein gene (S RNA) of 29 isolates from diverse crops and geographical locations yielded a maximum of only 4.3% nucleotide sequence difference. Phylogenetic analysis revealed no obvious groupings of isolates according to geographic origin or host species. TSWV isolates, that break TSWV resistance genes in tomato or pepper did not differ significantly in the N gene region studied, indicating that a different region of the virus genome is responsible for this trait.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The further development of Taqman quantitative real-time PCR (qPCR) assays for the absolute quantitation of Marek's disease virus serotype 1 (MDV1) and Herpesvirus of turkeys (HVT) viruses is described and the sensitivity and reproducibility of each assay reported. Using plasmid DNA copies, the lower limit of detection was determined to be 5 copies for the MDV1 assay and 75 copies for the HVT assay. Both assays were found to be highly reproducible for Ct values and calculated copy numbers with mean intra- and inter-assay coefficients of variation being less than 5% for Ct and 20% for calculated copy number. The genome copy number of MDV1 and HVT viruses was quantified in PBL and feather tips from experimentally infected chickens, and field poultry dust samples. Parallelism was demonstrated between the plasmid-based standard curves, and standard curves derived from infected spleen material containing both viral and host DNA, allowing the latter to be used for absolute quantification. These methods should prove useful for the reliable differentiation and absolute quantitation of MDV1 and HVT viruses in a wide range of samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biodiversity of sharks in the tropical Indo-Pacific is high, but species-specific information to assist sustainable resource exploitation is scarce. The null hypothesis of population genetic homogeneity was tested for scalloped hammerhead shark (Sphyrna lewini, n=244) and the milkshark (Rhizoprionodon acutus, n=209) from northern and eastern Australia, using nuclear (S. lewini, eight microsatellite loci; R. acutus, six loci) and mitochondrial gene markers (873 base pairs of NADH dehydrogenase subunit 4). We were unable to reject genetic homogeneity for S. lewini, which was as expected based on previous studies of this species. Less expected were similar results for R. acutus, which is more benthic and less vagile than S. lewini. These features are probably driving the genetic break found between Australian and central Indonesian R. acutus (F-statistics; mtDNA, 0.751 to 0.903; microsatellite loci, 0.038 to 0.047). Our results support the spatially-homogeneous management plan for shark species in Queensland, but caution is advised for species yet to be studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Small-angle neutron scattering (SANS) and ultra-small angle neutron scattering (USANS) with contrast matching techniques (Melnichenko and others, 2012) were used to investigate size distribution and gas accessibility in pores in an approximately 10.6 cm long Mississippian Barnett Shale butt core from the Fort Worth Basin, Texas, USA. SANS and USANS measurements record scattering from all pores, both open and closed, in the size range 10nm - ~10 μ. The techniques can also be used to determine the material that contains pores and the number of pores as a function of size. By injecting deuterated methane gas (CD4) at contrast matching pressure it is possible to distinguish which pores are accessible, or open, to fluids and which ones are not.