919 resultados para Maximal monotone operators
Resumo:
The activity of Control Center operators is important to guarantee the effective performance of Power Systems. Operators’ actions are crucial to deal with incidents, especially severe faults like blackouts. In this paper, we present an Intelligent Tutoring approach for training Portuguese Control Center operators in tasks like incident analysis and diagnosis, and service restoration of Power Systems. Intelligent Tutoring System (ITS) approach is used in the training of the operators, having into account context awareness and the unobtrusive integration in the working environment. Several Artificial Intelligence techniques were criteriously used and combined together to obtain an effective Intelligent Tutoring environment, namely Multiagent Systems, Neural Networks, Constraint-based Modeling, Intelligent Planning, Knowledge Representation, Expert Systems, User Modeling, and Intelligent User Interfaces.
Resumo:
Cyber-Physical Systems and Ambient Intelligence are two of the most important and emerging paradigms of our days. The introduction of renewable sources gave origin to a completely different dimension of the distribution generation problem. On the other hand, Electricity Markets introduced a different dimension in the complexity, the economic dimension. Our goal is to study how to proceed with the Intelligent Training of Operators in Power Systems Control Centres, considering the new reality of Renewable Sources, Distributed Generation, and Electricity Markets, under the emerging paradigms of Cyber-Physical Systems and Ambient Intelligence. We propose Intelligent Tutoring Systems as the approach to deal with the intelligent training of operators in these new circumstances.
Resumo:
The activity of Control Center operators is important to guarantee the effective performance of Power Systems. Operators’ actions are crucial to deal with incidents, especially severe faults, like blackouts. In this paper we present an Intelligent Tutoring approach for training Portuguese Control Centre operators in tasks like incident analysis and diagnosis, and service restoration of Power Systems. Intelligent Tutoring System (ITS) approach is used in the training of the operators, taking into account context awareness and the unobtrusive integration in the working environment.
Resumo:
Control Centre operators are essential to assure a good performance of Power Systems. Operators’ actions are critical in dealing with incidents, especially severe faults, like blackouts. In this paper we present an Intelligent Tutoring approach for training Portuguese Control Centre operators in incident analysis and diagnosis, and service restoration of Power Systems, offering context awareness and an easy integration in the working environment.
Resumo:
We perform a comparison between the fractional iteration and decomposition methods applied to the wave equation on Cantor set. The operators are taken in the local sense. The results illustrate the significant features of the two methods which are both very effective and straightforward for solving the differential equations with local fractional derivative.
Resumo:
The definition and programming of distributed applications has become a major research issue due to the increasing availability of (large scale) distributed platforms and the requirements posed by the economical globalization. However, such a task requires a huge effort due to the complexity of the distributed environments: large amount of users may communicate and share information across different authority domains; moreover, the “execution environment” or “computations” are dynamic since the number of users and the computational infrastructure change in time. Grid environments, in particular, promise to be an answer to deal with such complexity, by providing high performance execution support to large amount of users, and resource sharing across different organizations. Nevertheless, programming in Grid environments is still a difficult task. There is a lack of high level programming paradigms and support tools that may guide the application developer and allow reusability of state-of-the-art solutions. Specifically, the main goal of the work presented in this thesis is to contribute to the simplification of the development cycle of applications for Grid environments by bringing structure and flexibility to three stages of that cycle through a commonmodel. The stages are: the design phase, the execution phase, and the reconfiguration phase. The common model is based on the manipulation of patterns through pattern operators, and the division of both patterns and operators into two categories, namely structural and behavioural. Moreover, both structural and behavioural patterns are first class entities at each of the aforesaid stages. At the design phase, patterns can be manipulated like other first class entities such as components. This allows a more structured way to build applications by reusing and composing state-of-the-art patterns. At the execution phase, patterns are units of execution control: it is possible, for example, to start or stop and to resume the execution of a pattern as a single entity. At the reconfiguration phase, patterns can also be manipulated as single entities with the additional advantage that it is possible to perform a structural reconfiguration while keeping some of the behavioural constraints, and vice-versa. For example, it is possible to replace a behavioural pattern, which was applied to some structural pattern, with another behavioural pattern. In this thesis, besides the proposal of the methodology for distributed application development, as sketched above, a definition of a relevant set of pattern operators was made. The methodology and the expressivity of the pattern operators were assessed through the development of several representative distributed applications. To support this validation, a prototype was designed and implemented, encompassing some relevant patterns and a significant part of the patterns operators defined. This prototype was based in the Triana environment; Triana supports the development and deployment of distributed applications in the Grid through a dataflow-based programming model. Additionally, this thesis also presents the analysis of a mapping of some operators for execution control onto the Distributed Resource Management Application API (DRMAA). This assessment confirmed the suitability of the proposed model, as well as the generality and flexibility of the defined pattern operators
Resumo:
MSC Dissertation in Computer Engineering
Resumo:
International Journal of Mathematics and Mathematical Sciences, Vol.2006
Resumo:
Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies
Resumo:
This master’s thesis addresses the maintenance of pre-computed structures, which store a frequent or expensive query, for the nested bag data type in the high level work-flow language Pig Latin. This thesis defines a model suitable to accommodate incremental expressions over nested bags on Pig Latin. Afterwards, the partitioned normal form for sets is extended with further restrictions, in order to accommodate the nested bag model, allow the Pig Latin nest and unnest operators revert each other, and create a suitable environment to the incremental computations. Subsequently, the extended operators – extended union and extended difference – are defined for the nested bag data model with the partitioned normal form for bags (PNF Bag) restriction, and semantics for the extended operators are given. Finally, incremental data propagation expressions are proposed for the nest and unnest operators on the data model proposed with the PNF Bag restriction, and the proof of correctness is given.
Resumo:
To determine whether the slope of a maximal bronchial challenge test (in which FEV1 falls by over 50%) could be extrapolated from a standard bronchial challenge test (in which FEV1 falls up to 20%), 14 asthmatic children performed a single maximal bronchial challenge test with methacholin(dose range: 0.097–30.08 umol) by the dosimeter method. Maximal dose-response curves were included according to the following criteria: (1) at least one more dose beyond a FEV1 ù 20%; and (2) a MFEV1 ù 50%. PD20 FEV1 was calculated, and the slopes of the early part of the dose-response curve (standard dose-response slopes) and of the entire curve (maximal dose-response slopes) were calculated by two methods: the two-point slope (DRR) and the least squares method (LSS) in % FEV1 × umol−1. Maximal dose-response slopes were compared with the corresponding standard dose-response slopes by a paired Student’s t test after logarithmic transformation of the data; the goodness of fit of the LSS was also determined. Maximal dose-response slopes were significantly different (p < 0.0001) from those calculated on the early part of the curve: DRR20% (91.2 ± 2.7 FEV1% z umol−1)was 2.88 times higher than DRR50% (31.6 ± 3.4 DFEV1% z umol−1), and the LSS20% (89.1 ± 2.8% FEV1 z umol−1) was 3.10 times higher than LSS 50% (28.8 ± 1.5%FEV1 z umol−1). The goodness of fit of LSS 50% was significant in all cases, whereas LSS 20% failed to be significant in one. These results suggest that maximal dose-response slopes cannot be predicted from the data of standard bronchial challenge tests.
Resumo:
BACKGROUND: Few randomised studies have compared antiandrogen intermittent hormonal therapy (IHT) with continuous maximal androgen blockade (MAB) therapy for advanced prostate cancer (PCa). OBJECTIVE: To determine whether overall survival (OS) on IHT (cyproterone acetate; CPA) is noninferior to OS on continuous MAB. DESIGN, SETTING, AND PARTICIPANTS: This phase 3 randomised trial compared IHT and continuous MAB in patients with locally advanced or metastatic PCa. INTERVENTION: During induction, patients received CPA 200 mg/d for 2 wk and then monthly depot injections of a luteinising hormone-releasing hormone (LHRH; triptoreline 11.25 mg) analogue plus CPA 200 mg/d. Patients whose prostate-specific antigen (PSA) was <4 ng/ml after 3 mo of induction treatment were randomised to the IHT arm (stopped treatment and restarted on CPA 300 mg/d monotherapy if PSA rose to ≥20 ng/ml or they were symptomatic) or the continuous arm (CPA 200 mg/d plus monthly LHRH analogue). OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Primary outcome measurement was OS. Secondary outcomes included cause-specific survival, time to subjective or objective progression, and quality of life. Time off therapy in the intermittent arm was recorded. RESULTS AND LIMITATIONS: We recruited 1045 patients, of which 918 responded to induction therapy and were randomised (462 to IHT and 456 to continuous MAB). OS was similar between groups (p=0.25), and noninferiority of IHT was demonstrated (hazard ratio [HR]: 0.90; 95% confidence interval [CI], 0.76-1.07). There was a trend for an interaction between PSA and treatment (p=0.05), favouring IHT over continuous therapy in patients with PSA ≤1 ng/ml (HR: 0.79; 95% CI, 0.61-1.02). Men treated with IHT reported better sexual function. Among the 462 patients on IHT, 50% and 28% of patients were off therapy for ≥2.5 yr or >5 yr, respectively, after randomisation. The main limitation is that the length of time for the trial to mature means that other therapies are now available. A second limitation is that T3 patients may now profit from watchful waiting instead of androgen-deprivation therapy. CONCLUSIONS: Noninferiority of IHT in terms of survival and its association with better sexual activity than continuous therapy suggest that IHT should be considered for use in routine clinical practice.
Resumo:
BACKGROUND: Mesenchymal stem/stromal cells have unique properties favorable to their use in clinical practice and have been studied for cardiac repair. However, these cells are larger than coronary microvessels and there is controversy about the risk of embolization and microinfarctions, which could jeopardize the safety and efficacy of intracoronary route for their delivery. The index of microcirculatory resistance (IMR) is an invasive method for quantitatively assessing the coronary microcirculation status. OBJECTIVES: To examine heart microcirculation after intracoronary injection of mesenchymal stem/stromal cells with the index of microcirculatory resistance. METHODS: Healthy swine were randomized to receive by intracoronary route either 30x106 MSC or the same solution with no cells (1% human albumin/PBS) (placebo). Blinded operators took coronary pressure and flow measurements, prior to intracoronary infusion and at 5 and 30 minutes post-delivery. Coronary flow reserve (CFR) and the IMR were compared between groups. RESULTS: CFR and IMR were done with a variance within the 3 transit time measurements of 6% at rest and 11% at maximal hyperemia. After intracoronary infusion there were no significant differences in CFR. The IMR was significantly higher in MSC-injected animals (at 30 minutes, 14.2U vs. 8.8U, p = 0.02) and intragroup analysis showed a significant increase of 112% from baseline to 30 minutes after cell infusion, although no electrocardiographic changes or clinical deterioration were noted. CONCLUSION: Overall, this study provides definitive evidence of microcirculatory disruption upon intracoronary administration of mesenchymal stem/stromal cells, in a large animal model closely resembling human cardiac physiology, function and anatomy.
Resumo:
Dissertação de mestrado em Matemática