Resumo:
COSTA MIGUEL, M. C.; NONAKA, C. F. W.; GERMANO, A. R.; SOUZA, L. B.; SOUZA, L. B. Oral foreign body granuloma: unusual presentation of a rare adverse reaction to permanent injectable cosmetic filler. International journal of oral and maxillofacial surgery, v. 38, p. 385-387, 2009.
Resumo:
Purpose: The purpose of this study was to evaluate the effects of nicotine and ovariectomy on alveolar bone regeneration after exodontias in rats.Materials and Methods: For 30 days, sham ovariectomized (OVX)/NaCl, sham OVX/nicotine, OVX/NaCl, and OVX/nicotine animals were given 2 daily injections of saline or hemisulfate of nicotine. After this period, exodontic procedures were carried out and treatment continued up to the time of euthanasia on clays 7 and 14 when the alveoli were removed for further analyses.Results: The data confirmed that nicotine significantly delays the alveolar regeneration process after dental extraction in rats and showed that the association of nicotine with ovariectomy exacerbates these results.Conclusion: These results indicate that nicotine potentiated the effect of estrogen deficiency on bone regeneration induced by ovariectomy. (c) 2010 American Association of Oral and Maxillofacial Surgeons Oral Maxillofac Surg 68:2675-2681, 2010
Resumo:
Purpose: Euro-Collins solution was developed for the preservation of organs for transplantation, whose characteristics have raised interest for its use as a storage medium for avulsed teeth before replantation. This study evaluated histologically and morphometrically the healing process of dog teeth replanted after storage in Euro-Collins solution or bovine milk.Materials and Methods: Eighty roots of 4 young adult mongrel clogs were randomly assigned to 4 groups (n = 20) and the root canals were instrumented and obturated with gutta-percha and a calcium hydroxide-based sealer. After 2 weeks, the teeth were extracted and subjected to the following protocols: GI (negative control), replantation immediately after extraction; GII (positive control), bench-drying for 2 hours before replantation; GIII and GIV, immersion in 10 mL of whole bovine milk and Euro-Collins solution at 4 C, respectively, for 8 hours before replantation. The animals were sacrificed 90 days postoperatively. The pieces containing the replanted teeth were subjected to routine processing for histologic and histometric analyses under light microscopy and polarized light microscopy.Results: Root resorption was observed in all groups. GII exhibited the greatest loss of dental structure (P < .01), and inflammatory resorption was predominant in this group. Storage in milk showed poorer results than immediate replantation and storage in Euro-Collins solution (P < .01). The teeth stored in Euro-Collins solution presented similar extension of root resorption and periodontal ligament reorganization to those of immediately replanted teeth.Conclusions: The findings of this study suggest that the Euro-Collins solution is an adequate storage medium for keeping avulsed teeth for up to 8 hours before replantation.
Resumo:
Purpose: This study used bovine ribs to comparatively assess the deformation, roughness, and mass loss for 3 different types of surface treatments with burs, used in osteotomies, for the installation of osseointegrated implants.Materials and Methods: The study used 25 bovine ribs and 3 types of helical burs (2.0 mm and 3.0 mm) for osteotomies during implant placement (a steel bur [G1], a bur with tungsten carbide film coating in a carbon matrix [G2], and a zirconia bur [G3]), which were subdivided into 5 subgroups: 1, 2, 3, 4, and 5, corresponding to 0, 10, 20, 30, and 40 perforations, respectively. The surface roughness (mean roughness [Ra], partial roughness, and maximum roughness) and mass (in grams) of all the burs were measured, and the burs were analyzed in a scanning electron microscope before and after use. Data were tabulated and statistically analyzed by use of the Kruskal-Wallis test, and when a statistically significant difference was found, the Dunn test was used.Results: There was a loss of mass in all groups (G1, G2, and G3), and this loss was gradual, according to the number of perforations made (1, 2, 3, 4, and 5). However, this difference was not statistically significant (P < .05). Regarding the roughness, G3 presented an increase in Ra, partial roughness, and maximum roughness (P < .05) compared with G2 and an increase in Ra compared with G1. There was no statistically significant difference (P > .05) between G1 and G2. The scanning electron microscopy analysis found areas of deformation in all the 2.0-mm samples, with loss of substrates, and this characteristic was more frequent in G3.Conclusions: The 2.0-mm zirconia burs had a greater loss of substrates and abrasive wear in the cutting area. They also presented an increased roughness when compared with the steel and the tungsten carbide coating film in carbon matrix. There was no statistically significant difference (P < .05) between G1 and G2 in any mechanical test carried out. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:e608-e621, 2012
Resumo:
Purpose: This study sought to evaluate the effect of repeated implant drilling on the immediate bone-cell viability, and to evaluate drill wear by scanning electron microscopy.Materials and Methods: The tibiae of 10 rabbits were used, divided into 5 groups (G): G1 corresponded to new drills, and G2, G3, G4, and G5 corresponded to drills used 10, 20, 30, and 40 times, respectively. The animals received 10 sequential osteotomies in each tibia. The animals were euthanized immediately after the osteotomies by perfusion with 4% formaldehyde. Samples then underwent immunohistochemistry processing for ordinal qualitative analysis of osteoprotegerin (OPG), the RANK ligant (RANKL; a tumor-related necrosis factor receptor family), and osteocalcin protein immunolabels, as detected by the immunoperoxidase method and revealed with 3,3-diaminobenzidine. Drill wear and plastic deformation were analyzed by scanning electron microscopy (SEM).Results: The proteins were expressed in osteocytes of the superior bone cortical during the 40 drillings. However, in G4 and G5, a discrete increase in the expression of RANKL was observed, when compared with OPG; this increase was statistically significant in G5 (P = .016). The SEM analysis revealed major plastic deformation and drill wear in G4 and G5.Conclusion: Based on the present methodology, it may be concluded that cell viability is preserved if a less traumatic surgical protocol is used. However, the repeated use of drills alters the protein balance as of the thirtieth perforation. (C) 2008 American Association of Oral and Maxillofacial Surgeons.
Resumo:
This study verified the resistance to displacement of six miniplate fixation methods after sagittal split osteotomy (SSO). SSO was performed in 30 polyurethane synthetic mandible replicas. The distal segments were advanced (4 mm) and specimens were grouped according to the fixation method: four-hole standard miniplate; four-hole locking miniplate; six-hole standard miniplate; six-hole locking miniplate; six-hole standard sagittal miniplate; six-hole locking sagittal miniplate. Biomechanical evaluation was performed by applying compression loads to three points on the second molar region, using an Instron universal testing machine until a 3 mm displacement of the segments occurred. Compression loads able to produce 3 mm displacement were recorded in kN and subjected to analysis of variance (P < 0.01) and Tukey's tests for comparison between groups (P < 0.05). The locking sagittal miniplate showed higher resistance to displacement than the regular four- and six-hole locking and standard miniplates. No significant differences were observed between the locking sagittal miniplate and the regular sagittal or the four-hole locking miniplates. Two of the three groups with the best results had locking plate fixation methods. Fixation of SSO with a single miniplate is better accomplished using six-hole locking sagittal miniplates, six-hole standard sagittal miniplates, or four-hole locking miniplates; these methods are more resistant to displacement.
Resumo:
Traumatic injuries treatment of the fronto-naso-orbito-ethmoidal region has been one of the most challenging treatments within maxillofacial surgery, particularly of extensive orbital defects, very common in this type of pathologic condition. A 48-year-old man involved in a car collision presented an extensive bilateral fracture of the orbit medial wall, nasal bones, the nasal septum, and the frontal anterior table. The clinical and tomographic findings concluded the diagnosis of a maxilla and fronto-naso-orbito-ethmoidal fracture. Among the variety of biomaterials, the titanium mesh was elected because of the extension and magnitude of the bone defect, obtaining this way esthetic and functional results with better prognosis.
Resumo:
Purpose: The aim of this study was to evaluate the satisfaction of patients rehabilitated with zygomatic fixtures and prosthesis with immediate loading.Materials and Methods: The study selected patients who were rehabilitated with zygomatic implants at the clinic of the Latin American Institute for Dental Research and Education (ILAPEO. Curitiba-PR. Brasil) between 2005 and 2009. The patients were asked to answer a control-questionnaire during their follow-up visits. Data were collected regarding the level of patient satisfaction, reason for dissatisfaction, number of post-operative clinical sessions, and the type of complication. Sixteen patients were selected: 10 females and 6 males.Results: Half of the patients were completely satisfied while the other half were satisfied with some complaints. The complaints were related to hygiene, esthetics, phonetics, and discomfort during chewing. Regarding the post-operative evaluation, 50% of the patients were attended due to the prosthesis (62.5%) and the implant (37.5%).Conclusions: The treatment with zygomatic fixtures is predictable and reliable. The patients were satisfied both with implants and prosthesis. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70: 314-319, 2012
Resumo:
This in vitro study evaluated the influence of the type of miniplate and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to four groups (n = 15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0 mm miniplates and 2.0 mm x 6 mm rnonocortical screws. In groups 1 and 2, two conventional (G1) or locking (G2) screws were installed in each bone segment using a conventional (G1) or a locking (02) straight miniplate; in groups 3 and 4, three conventional (03) or locking (04) screws were installed in the proximal segment and four conventional (G3) or locking (04) screws were installed in the distal segment using a conventional (G3) or a locking (G4) seven-hole straight miniplate. The hemimandibles were loaded in compressive strength until a 4 mm displacement occurred between the segments, vertically or horizontally. Locking plate/screw systems provided significantly greater resistance to displacement than conventional ones (p < .01). Locking miniplates offered more resistance than conventional miniplates. Long locking miniplates provided greater stability than short ones.
Resumo:
Eagle syndrome is symptomatic elongation of the styloid process, or calcification of the stylomandibular ligament. Difficulty with deglutition. phonation. cervical movement. and the sensation of a foreign body in the oropharynx are all symptoms of this syndrome. Its treatment consists of partial removal of the styloid process. leaving it within the range of normality. We describe the technique, report it case, and point Out Sortie of the advantages. such as the simplicity of the procedure, reduced operating time, and lack risks of operative complications. (C) 2008 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Resumo:
The purpose of this study was to quantify cephalometric and three-dimensional alterations of the posterior airway space of patients who underwent maxillomandibular advancement surgery. 20 patients treated by maxillomandibular advancement were selected. The minimal postoperative period was 6 months. The treated patients underwent cone-beam computed tomography at 3 distinct time intervals, preoperative (T1), immediate postoperative period up to 15 days after surgery (T2), and late postoperative period at least 6 months after surgery. The results showed that the maxillomandibular advancement promoted an increase in the posterior airway space in each patient in all the analyses performed, with a statistically significant difference between T2 and T1, and between T3 and T1, p < 0.05. There was a statistical difference between T2 and T3 in the analysis of area and volume, which means that the airway space became narrower after 6 months compared with the immediate postoperative period. The maxillomandibular advancement procedure allowed great linear area and volume increase in posterior airway space in the immediate and late postoperative periods, but there was partial loss of the increased space after 6 months. The linear analysis of airway space has limited results when compared with analysis of area and volume.
Resumo:
Purpose: The aim of this in vitro study was to assess the biomechanical stability of 9 different osteosynthesis methods after sagittal split ramus osteotomy by simulating the masticatory forces and using a 3-point biomechanical test method.Materials and Methods: Forty-five polyurethane hemimandibles with bone-like consistency were randomly assigned to 9 groups (n = 5) and subjected to sagittal split ramus osteotomy. After 4-mm advancement of the distal segment, the bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplate/screw systems: group A, one 4-hole conventional straight miniplate; group B, one 4-hole locking straight miniplate; group C, one 4-hole conventional miniplate and one bicortical screw; group D, one 4-hole locking miniplate and 1 bicortical screw; group E, one 6-hole conventional straight miniplate; group F, one 6-hole locking straight miniplate; group (3: two 4-hole conventional straight miniplates; group H. two 4-hole locking straight miniplates; and group 1, 3 bicortical screws in an inverted-L. pattern. All models were mounted on a base especially constructed for this purpose. Using a 3-point biomechanical test model, the hemimandibles were loaded in compressive strength in an Instron machine (Norwood, MA) until a 3-mm displacement occurred between segments vertically or horizontally. Data were analyzed by analysis of variance and Tukey test (alpha = 1%).Results: The multiparametric comparison of the groups showed a statistically significant difference (P<.01) between groups that used 2 miniplates (groups G and H), 1 miniplate and 1 bicortical screw (groups C and D), and only bicortical screws (group D compared with groups that used only 1 miniplate with 2 screws per segment (groups A and B) and 3 screws per segment (groups E and F).Conclusion: The placement of 2.0-mm-diameter bicortical screws in the retromolar region, associated or not with conventional and locking miniplates with monocortical screws, promoted a better stabilization of bone segments. Locking miniplates presented a better performance in bone fixation in all groups. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:724-730, 2010
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this Study was to evaluate Soft tissue response to rnaxillo-mandibular counter-clockwise rotation, with TMJ reconstruction and mandibular advancement using TMJ Concepts (R) total joint prostheses, and maxillary osteotomies in 44 females. All patients were operated at Baylor University Medical Center, Dallas TX, USA, by one Surgeon (Wolford). Eighteen patients had genioplasties with either porous block hydroxyapatite or hard tissue replacement implants (Group 2) 26 had no genioplasty (Group 1). Surgically, the maxilla moved forward and upward by counter-clockwise maxillo-mandibular rotation with greater horizontal movement in Group 2. Vertically, both groups showed diversity of maxillo-mandibular mean movement. Group I showed a consistent 1:0.97 ratio of hard to soft tissue advancement at pogonion; Group 2 results were less consistent, with ratios between 1:0.84 and 1:1.02. Horizontal changes in upper lip morphology after maxillary advancement/impaction, VY closure, and alar base cinch sutures showed greater movement in both groups, than observed in hard tissue. Counter-clockwise rotation of the maxillo-mandibular complex using TMJ Concepts total joint prostheses resulted in similar soft tissue response as previously reported for traditional maxillo-mandibular advancement without counter-clockwise rotation of the occlusal plane. The association of chin implants, in the present sample, showed higher variability of soft tissue response.