974 resultados para LC-ESI-LTQ-Orbitrap


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recently, the prevalence of Fasciola hepatica in some areas has increased considerably and the availability of a vaccine to protect livestock from infection would represent a major advance in tools available for controlling this disease. To date, most vaccine-target discovery research on this parasite has concentrated on proteomic and transcriptomic approaches whereas little work has been carried out on glycosylation. As the F. hepatica tegument (Teg) may contain glycans potentially relevant to vaccine development and the Newly Excysted Juvenile (NEJ) is the first lifecycle stage in contact with the definitive host, our work has focused on assessing the glycosylation of the NEJTeg and identifying the NEJTeg glycoprotein repertoire. After in vitro excystation, NEJ were fixed and NEJTeg was extracted. Matrix-assisted laser desorption ionisation-time of flight-mass spectrometry (MALDI-TOF-MS) analysis of released N-glycans revealed that oligomannose and core-fucosylated truncated N-glycans were the most dominant glycan types. By lectin binding studies these glycans were identified mainly on the NEJ surface, together with the oral and ventral suckers. NEJTeg glycoproteins were affinity purified after targeted biotinylation of the glycans and identified using liquid chromatography and tandem mass spectrometry (LC-MS/MS). From the total set of proteins previously identified in NEJTeg, eighteen were also detected in the glycosylated fraction, including the F. hepatica Cathepsin B3 (FhCB3) and two of the Cathepsin L3 (FhCL3) proteins, among others. To confirm glycosylation of cathepsins, analysis at the glycopeptide level by LC-ESI-ion-trap-MS/MS with collision-induced dissociation (CID) and electron-transfer dissociation (ETD) was carried out. We established that cathepsin B1 (FhCB1) on position N80, and FhCL3 (BN1106_s10139B000014, scaffold10139) on position N153, carry unusual paucimannosidic Man2GlcNAc2 glycans. To our knowledge, this is the first description of F. hepatica NEJ glycosylation and the first report of N-glycosylation of F. hepatica cathepsins. The significance of these findings for immunological studies and vaccine development is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O Rio Grande Sul destaca-se no cenário nacional como grande produtor de diversas culturas, as quais demandam grande quantidade de agrotóxicos das mais diversas classes químicas e toxicidades. No entanto a intensa utilização destes compostos torna-se uma preocupação devido a possíveis contaminações das águas superficiais e subterrâneas. Em virtude da degradação dos mananciais a água mineral passou a ser uma das fontes mais utilizadas para o consumo humano, pois tem-se a percepção de que a mesma possui melhor qualidade que a água tratada, além disso acredita-se que a mesma esta isenta de substâncias orgânicas prejudiciais à saúde humana. Neste trabalho, foi realizada a determinação dos agrotóxicos atrazina, simazina, imazapique, imazetapir, imidacloprido, ciproconazol, tebuconazol e epoxiconazol em água mineral empregando a Microextração Líquido-Líquido Dispersiva (DLLME), Microextração Líquido-Líquido Dispersiva com Solidificação da Gota Orgânica Flutuante (DLLME-SFO) e Cromatografia Líquida acoplada à Espectrometria de Massas em série com fonte de ionização por Eletronebulização (LC-ESI-MS/MS). Para o método empregando DLLME e LC-ESI-MS/MS foram otimizados alguns fatores como o tipo e volume de solvente extrator e dispersor e pH. Após a otimização dos parâmetros de extração, fragmentação dos compostos e separação cromatográfica, o método foi validado avaliando-se curva analítica, linearidade, limites de detecção e quantificação, precisão (repetitividade e precisão intermediária) e exatidão (recuperação). Todas as curvas analíticas apresentaram valores de r maiores que 0,999. Os Limites de Quantificação (LOQs) para o método estiveram na faixa de 5 a 500 ng L-1. Foram obtidas recuperações entre 102 - 120% para a repetibilidade e entre 92 e 110% para a precisão intermediária, com RSD de 2 a 10% para todos os compostos. Para o método empregando DLLME-SFO e LC-ESI-MS/MS foram avaliados alguns parâmetros que afetam a eficiência da extração como, tipo e volume de solvente extrator e dispersor, força iônica e pH. Nas condições ótimas de extração todas as curvas analíticas apresentaram valores de r maiores que 0,997. Os LOQs para o método variaram entre 12,5 - 125 ng L-1. As recuperações foram entre 70 e 118% para a repetitividade e entre 76 e 95% para a precisão intermediária, com RSD de 2 a 18% para todos os compostos. Com relação ao Efeito Matriz (EM) avaliado para todos os compostos pelos dois métodos, foi observado baixo EM. Isso indicou que não é necessário utilizar a curva analítica preparada no extrato branco da matriz para a quantificação destes analitos. Ambos os métodos foram aplicados para a determinação de resíduos de agrotóxicos em amostras de água mineral provenientes de diferentes regiões do estado do Rio Grande do Sul e não foram encontrados resíduos de agrotóxicos nas amostras analisadas. Os métodos validados apresentaram como principais vantagens baixo consumo de solventes orgânicos e amostra, rapidez, altos fatores de concentração e recuperações dentro da faixa aceitável. Os limites de quantificação dos métodos ficaram abaixo dos limites máximos de resíduos permitidos pela legislação brasileira para agrotóxicos em água mineral.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Deoxinivalenol (DON), uma das principais micotoxinas encontradas em matrizes alimentares, é um composto químico que possui em sua estrutura um anel epóxido que lhe confere alto grau de toxicidade. A aplicação de enzimas em processos de degradação de DON vem se destacando, pela estabilidade durante o processo reacional e baixo custo de produção. O objetivo desse trabalho foi estudar o potencial de peroxidase proveniente de farelo de arroz (FA) e farelo de soja (FS) para degradar DON. As condições de obtenção da PO a partir de FA foram definidas por planejamento experimental DCCR 23 , sendo extraída de 5 g de farelo com 50 mL de tampão fosfato 0,04 mol L-1 pH 5, agitados orbitalmente durante 60 min a 100 rpm, e para a PO obtida de FS as condições diferenciaram somente quanto a solução extratora, tampão fosfato 0,01 mol L-1 pH 4,7. A técnica que apresentou melhores índices de purificação para a enzima foi a partição trifásica apresentando fator de purificação e recuperação de 5,6 e 50 % para a obtida de FA e 13,61 e 50 % para FS. A PO de FA apresentou maior atividade em tampão fosfato 5 mmol L-1 pH 5,5 para as formas bruta e pura, diferindo na temperatura de reação de 25 °C e 10 °C, KM de 0,15 e 0,06 mmol L-1 e Vmáx de 769 e 667 U mg-1 , respectivamente. A PO de FS as condições foram: tampão fosfato 5 mmol L-1 pH 5, reação a 35 e 30 °C durante 10 e 5 min, KM de 0,17 e 0,05 mmol L-1 e Vmáx de 196 e 182 U mg-1 , respectivamente. A PO de FA demonstrou maior estabilidade em pH 5 enquanto que a de FS em pH 6, ambas enzimas apresentaram maior estabilidade térmica a 0 °C, as massas moleculares encontradas por eletroforese foram 41 e 34 kDa, respectivamente. Ao final das etapas de obtenção, purificação e caracterização obteve-se uma atividade específica de 116 e 794 U.mg-1 , e 4363 e 17453 U g-1 , respectivamente para PO de FA e FS. A determinação de DON e De-DON foi realizada por HPLC-DAD e LC-ESI-MS/MS para avaliação dos ensaios de degradação. A enzima comercial HRP, mostrou maior potencial de redução sobre DON (55% após 1 h de reação), no entanto em 3 h de reação, a concentração inicial da micotoxina DON foi verificada, o que evidencia que a redução pode ocorrer por adsorção ou por formação de um composto de degradação que apresente a mesma massa molecular. O emprego da enzima PO obtida de FA e FS na degradação necessita de uma avaliação cinética micotoxicologica para definição das condições de redução significativa dos níveis de DON.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: The area near the Araguaia River, between Goiás and Mato Grosso States, is the location of a portion of the recharging of the Guarani Aquifer, which is one of the world¿s largest aquifer systems and an important source of drinking water. This reservoir could be threatened by the widespread use of pesticides in maize and soybean cultivation in this area. Thus, this work developed analytical methods for the determination of imazethapyr, nicosulfuron, imazaquin, carbofuran, atrazine, linuron, clorimuronethyl and diflubenzuron, pesticides used in maize and soybean cultivation. Pesticide separation, identification and quantification were performed using High-Performance Liquid Chromatography with Diode Array Detection (HPLC-DAD) and Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry (LC-ESI-MS/MS). Solid Phase Extraction (SPE) with C18 sorbents was optimized for sample extraction from water. Soil samples were extracted by mechanical shaking, sonication or microwave-assisted extraction with industrial and home microwave ovens. Methods were validated resulting in limits of quantification (LOQ) for the pesticides in water in the range of 0.015-0.1 ng mL, using SPE-HPLC-DAD, and 0.01 ng mL using LC-ESI-MS/MS. LOQ of 1 ng mL for all pesticides in soil were achieved using the home microwave oven and LC-ESI-MS/MS. Recoveries for pesticides with all methods were in the range 70-120 %. Relative standard deviations for repeatability and intermediate precision were less than 15 %. SPEHPLC- DAD and LC-ESI-MS/MS were employed for the analysis of samples of water from the recharge area and most of the pesticides were detected at concentrations below the minimum residue limit (MRL) of 0.1 ng mL established by the European Community. The home microwave oven and LC-ESI-MS/MS were used for the analysis of soil samples from two other regions of Brazil and the pesticides were not detected in these samples. Adsorption and desorption parameters were determined for imazethapyr, imazaquin, nicosulfuron and chlorimuron-ethyl, indicating that these pesticides have little affinity for the soil of the region of the Guarani Aquifer recharge, and show significant leaching potential, according to the ground water ubiquity score (GUS index) for these pesticides.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To characterise the phytochemical profile of whole plants of Centaurea balsamita, C. depressa and C. lycopifolia with LC-ESI-MS/MS, and as well as their antioxidant, anticholinesterase and antimicrobial activities. Methods: Organic and aqueous extracts of the three Centaurea species were evaluated for DPPH free radical, ABTS cation radical scavenging and cupric reducing antioxidant capacity (CUPRAC). Acetyland butyryl-cholinesterase enzyme inhibition abilities of the extracts using petroleum ether, acetone, methanol and water were studied to determine anticholinesterase activity, while antimicrobial activity was determined by disc diffusion method using appropriate antimicrobial standards and organisms. The phytochemical components of the methanol extracts were assessed by LC-MS/MS. Results: The methanol extract of C. balsamita exhibited much higher DPPH free and ABTS cation radicals scavenging activities (with IC50 of 62.65 ± 0.97 and 24.21 ± 0.70 mg/ml, respectively) than the other extracts. The petroleum ether extracts of the plant species exhibited moderate inhibitory activity against butyrylcholinesterase enzymes while the acetone extract of C. balsamita showed good antifungal activity against Candida albicans. Quinic acid (17513 ± 813 μg/g, 63874 ± 3066 μg/g and 108234 ± 5195 μg/g) was the major compound found in the methanol extracts of C. balsamita, C. depressa and C. Lycopifolia, respectively. Conclusion: These results indicate quinic acid is the major compound in the three plant species and that Centaurea balsamita has significant antioxidant, anticholinesterase and antimicrobial properties. Further studies to identify the compounds in the extracts responsible for the activities are required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho teve como objectivo, o desenvolvimento de um método electroquímico, para quantificação do fármaco carbamazepina (CBZ) em águas contaminadas. Neste trabalho foram utilizados quatro métodos voltamétricos: a voltametria cíclica, a voltametria de varrimento linear, a voltametria de onda quadrada e a voltametria de impulso diferencial. Os eléctrodos de trabalho utilizados foram, o eléctrodo de mercúrio de gota suspensa, o eléctrodo de carbono vítreo clássico e um eléctrodo de carbono vítreo modificado com um filme de nanotubos de carbono de paredes múltiplas (MWCNTs). O eléctrodo de mercúrio de gota suspensa permitiu o estudo da redução da CBZ numa região de potencial mais catódico, e os eléctrodos de carbono vítreo, com e sem modificação, permitiram o estudo da oxidação da CBZ numa região de potencial mais anódico. Nas condições experimentais estudadas, o eléctrodo de mercúrio de gota suspensa revelou ser um sensor voltamétrico pouco eficaz na determinação quantitativa da carbamazepina, em amostras com uma matriz complexa. Entre os eléctrodos de carbono vítreo, o eléctrodo de carbono vítreo modificado com os MWCNTs revelou ser o sensor voltamétrico mais eficaz e sensível, na detecção e determinação da carbamazepina. Modificado com um filme de nanotubos de carbono de paredes múltiplas, que previamente foram dispersos em dihexadecilhidrogenofosfato (DHP) e água, este novo eléctrodo permitiu obter uma resposta electroquímica da CBZ, consideravelmente superior ao eléctrodo não modificado. Utilizando a voltametria de varrimento linear e as condições experimentais consideradas óptimas, o eléctrodo nanoestruturado permitiu obter uma relação linear entre o sinal medido e a concentração da CBZ no intervalo 0.13- 1.60 M (30.7- 378 g -1), com os limites de detecção e quantificação mais baixos, até à data reportados com métodos electroquímicos (0.04 e 0.14M, respectivamente). O eléctrodo modificado foi aplicado na quantificação da CBZ, em formulações farmacêuticas, em águas naturais tratadas e em amostras de águas residuais, ambas dopadas, obtendo-se taxas de recuperação consideravelmente elevadas (100.6%, 98.0%,95.8%, respectivamente). Os resultados obtidos, na análise da CBZ em amostras ambientais, com o eléctrodo modificado, foram comparados com resultados obtidos por HPLC-UV e LC­ ESI-MS/MS, validando o método electroquímico desenvolvido neste trabalho. ABSTRACT: The aim of this work was to develop a new electrochemical method for the quantification of carbamazepine (CBZ) in contaminated waters. ln this study, four voltammetric methods were used: cyclic voltammetry, linear sweep voltammetry, square wave voltammetry and differential pulse voltammetry. the working electrodes used were the hanging mercury drop electrode (HMDE), the classical glassy carbon electrode (GCE), and a glassy carbon electrode modified with a film of multi-walled carbon nanotubes (MWCNls). Using HMDE, the reduction of CBZ was studied in the cathodic potential region. the CGE sensors, with or without modification, allowed the study of CBZ oxidation in the anodic potential region. ln the tested conditions, the results obtained for the quantification of CBZ using the HMDE sensor were not very satisfactory, especially when more complex samples were analysed. When the MWCNls-dihexadecyl hydrogen phosphate (DHP) film­ coated GCE was used for the voltammetric determination of CBZ, the results obtained showed that this modified electrode exhibits excellent enhancement effects on the electrochemical oxidation of CBZ. the oxidation peak current of CBZ at this film­ modified electrode increased significantly, when compared with that at a bare glassy carbon electrode. The enhanced electrooxidation and voltammetry of CBZ at the surface of MWCNTs-DHP film coated GCE in phosphate buffer solution (pH 6.71) was attributed to the unique properties of MWCNTs such as large specific surface area and strong adsorptive properties providing more reaction sites. The proposed method was applied to the quantification of CBZ in pharmaceutical formulations, drinking water and wastewater samples with good recoveries and low limits of detection and quantification (0.04 and 0.14 M, respectively), and was positively compared with chromatographic techniques usually used in the quantification of pharmaceutical compounds in environmental samples. HPLC-UV and LC-ESI-MS/MS were also used in the quantification of CBZ in pharmaceutical formulations and wastewater samples to prove the importance and accuracy of his voltammetric method.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper describes an analytical method for the rapid screening and identification of the phenolic constituents present in the polar extracts of different Lychnophora spp. using LC-UV/DAD-ESI-MS and LC-UV/DAD-ESI-MS/MS. Compounds were identified based on UV, retention time, MS experiments and MS/MS of precursor ion or standard. On-line phytochemical investigation of Lychnophora spp. allowed for the identification of flavonoids, chlorogenic acid derivatives and lactones. Some of the observed compounds were for the first time identified in Lychnophora species in a fast analytical procedure. The data obtained here may be helpful to the investigation of polar constituents from other Lychnophora species.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

High-resolution mass spectrometry (HRMS) has been associated with qualitative and research analysis and QQQ-MS with quantitative and routine analysis. This view is now challenged and for this reason, we have evaluated the quantitative LC-MS performance of a new high-resolution mass spectrometer (HRMS), a Q-orbitrap-MS, and compared the results obtained with a recent triple-quadrupole MS (QQQ-MS). High-resolution full-scan (HR-FS) and MS/MS acquisitions have been tested with real plasma extracts or pure standards. Limits of detection, dynamic range, mass accuracy and false positive or false negative detections have been determined or investigated with protease inhibitors, tyrosine kinase inhibitors, steroids and metanephrines. Our quantitative results show that today's available HRMS are reliable and sensitive quantitative instruments and comparable to QQQ-MS quantitative performance. Taking into account their versatility, user-friendliness and robustness, we believe that HRMS should be seen more and more as key instruments in quantitative LC-MS analyses. In this scenario, most targeted LC-HRMS analyses should be performed by HR-FS recording virtually "all" ions. In addition to absolute quantifications, HR-FS will allow the relative quantifications of hundreds of metabolites in plasma revealing individual's metabolome and exposome. This phenotyping of known metabolites should promote HRMS in clinical environment. A few other LC-HRMS analyses should be performed in single-ion-monitoring or MS/MS mode when increased sensitivity and/or detection selectivity will be necessary.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The phenolic composition of heartwood extracts from Fraxinus excelsior L. and F. americana L., both before and after toasting in cooperage, was studied using LC-DAD/ESI-MS/MS. Low-molecular weight (LMW) phenolic compounds, secoiridoids, phenylethanoid glycosides, dilignols and oligolignols compounds were detected, and 48 were identified, or tentatively characterized, on the basis of their retention time, UV/Vis and MS spectra, and MS fragmentation patterns. Some LMW phenolic compounds like protocatechuic acid and aldehyde, hydroxytyrosol and tyrosol, were unlike to those for oak wood, while ellagic and gallic acid were not found. The toasting of wood resulted in a progressive increase in lignin degradation products with regard to toasting intensity. The levels of some of these compounds in medium-toasted ash woods were much higher than those normally detected in toasted oak, highlighting vanillin levels, thus a more pronounced vanilla character can be expected when using toasted ash wood in the aging wines. Moreover, in seasoned wood, we found a great variety of phenolic compounds which had not been found in oak wood, especially oleuropein, ligstroside and olivil, along with verbascoside and isoverbascoside in F. excelsior, and oleoside in F. americana. Toasting mainly provoked their degradation, thus in medium-toasted wood, only four of them were detected. This resulted in a minor differentiation between toasted ash and oak woods. The absence of tannins in ash wood, which are very important in oak wood, is another peculiar characteristic that should be taken into account when considering its use in cooperage. Copyright (C) 2012 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A selective method using three-phase liquid-phase microextraction (LPME) in conjunction with LC-MS-MS was devised for the enantioselective determination of chloroquine and its n-dealkylated metabolites in plasma samples. After alkalinization of the samples, the analytes were extracted into n-octanol immobilized in the pores of a polypropylene hollow fiber membrane and back extracted into the acidic acceptor phase (0.1 M TFA) filled into the lumen of the hollow fiber. Following LPME, the analytes were resolved on a Chirobiotic V column using methanol/ACN/glacial aceti acid/diethylamine (90:10:0.5:0.5 by volume) as the mobile phase. The MS detection was carried out using multiple reaction monitoring with ESI in the positive ion mode. The optimized LPME method yielded extraction recoveries ranging from 28 to 66%. The method was linear over 5 - 500 ng/mL and precision (RSD) and accuracy (relative error) values were below 15% for all analytes. The developed method was applied to the determination of the analytes in rat plasma samples after oral administration of the racemic drug.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To study the stress-induced effects caused by wounding under a new perspective, a metabolomic strategy based on HPLC-MS has been devised for the model plant Arabidopsis thaliana. To detect induced metabolites and precisely localise these compounds among the numerous constitutive metabolites, HPLC-MS analyses were performed in a two-step strategy. In a first step, rapid direct TOF-MS measurements of the crude leaf extract were performed with a ballistic gradient on a short LC-column. The HPLC-MS data were investigated by multivariate analysis as total mass spectra (TMS). Principal components analysis (PCA) and hierarchical cluster analysis (HCA) on principal coordinates were combined for data treatment. PCA and HCA demonstrated a clear clustering of plant specimens selecting the highest discriminating ions given by the complete data analysis, leading to the specific detection of discrete-induced ions (m/z values). Furthermore, pool constitution with plants of homogeneous behaviour was achieved for confirmatory analysis. In this second step, long high-resolution LC profilings on an UPLC-TOF-MS system were used on pooled samples. This allowed to precisely localise the putative biological marker induced by wounding and by specific extraction of accurate m/z values detected in the screening procedure with the TMS spectra.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The capabilities of a high-resolution (HR), accurate mass spectrometer (Exactive-MS) operating in full scan MS mode was investigated for the quantitative LC/MS analysis of drugs in patients' plasma samples. A mass resolution of 50,000 (FWHM) at m/z 200 and a mass extracted window of 5 ppm around the theoretical m/z of each analyte were used to construct chromatograms for quantitation. The quantitative performance of the Exactive-MS was compared with that of a triple quadrupole mass spectrometer (TQ-MS), TSQ Quantum Discovery or Quantum Ultra, operating in the conventional selected reaction monitoring (SRM) mode. The study consisted of 17 therapeutic drugs including 8 antifungal agents (anidulafungin, caspofungin, fluconazole, itraconazole, hydroxyitraconazole posaconazole, voriconazole and voriconazole-N-oxide), 4 immunosuppressants (ciclosporine, everolimus, sirolimus and tacrolimus) and 5 protein kinase inhibitors (dasatinib, imatinib, nilotinib, sorafenib and sunitinib). The quantitative results obtained with HR-MS acquisition show comparable detection specificity, assay precision, accuracy, linearity and sensitivity to SRM acquisition. Importantly, HR-MS offers several benefits over TQ-MS technology: absence of SRM optimization, time saving when changing the analysis from one MS to another, more complete information of what is in the samples and easier troubleshooting. Our work demonstrates that U/HPLC coupled to Exactive HR-MS delivers comparable results to TQ-MS in routine quantitative drug analyses. Considering the advantages of HR-MS, these results suggest that, in the near future, there should be a shift in how routine quantitative analyses of small molecules, particularly for therapeutic drugs, are performed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An assay for the simultaneous analysis of pharmaceutical compounds and their metabolites from micro-whole blood samples (i.e. 5 microL) was developed using an on-line dried blood spot (on-line DBS) device coupled with hydrophilic interaction/reversed-phase (HILIC/RP) LC/MS/MS. Filter paper is directly integrated to the LC device using a homemade inox desorption cell. Without any sample pretreatment, analytes are desorbed from the paper towards an automated system of valves linking a zwitterionic-HILIC column to an RP C18 column. In the same run, the polar fraction is separated by the zwitterionic-HILIC column while the non-polar fraction is eluted on the RP C18. Both fractions are detected by IT-MS operating in full scan mode for the survey scan and in product ion mode for the dependant scan using an ESI source. The procedure was evaluated by the simultaneous qualitative analysis of four probes and their relative phase I and II metabolites spiked in whole blood. In addition, the method was successfully applied to the in vivo monitoring of buprenorphine metabolism after the administration of an intraperitoneal injection of 30 mg/kg on adult female Wistar rat.