406 resultados para Interferences


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Iridium powder is introduced into sol-gel process for the first time to fabricate a novel type of sol-gel derived metal composite electrode. The iridium ceramic electrode shows excellent electrocatalytic action for both oxidation and reduction of hydrogen peroxide. The glucose biosensor based on sol-gel derived iridium composite electrode was fabricated. The biosensor shows highly selectivity towards glucose because of the strong catalytic action of iridium composite matrix for enzyme-liberated hydrogen peroxide at low operating potential, at which common interferences cannot be sensed. The novel type of biosensor can be renewed by simply mechanical polishing with favorable reproducibility and long-term stability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Iridium powder is introduced into sol-gel process for the first time to fabricate a novel type of sol-gel derived metal composite electrode. The iridium ceramic electrode shows excellent electrocatalytic action for both oxidation and reduction of hydrogen peroxide. The glucose biosensor based on sol-gel derived iridium composite electrode was fabricated. The biosensor shows highly selectivity towards glucose because of the strong catalytic action of iridium composite matrix for enzyme-liberated hydrogen peroxide at low operating potential, at which common interferences cannot be sensed. The novel type of biosensor can be renewed by simply mechanical polishing with favorable reproducibility and long-term stability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Matrix effects in now injection (FI) inductively coupled plasma mass spectrometry has been studied,and the results have been compared with those of continuous nebulization. The matrix element As and nu with higher ionization potential ( > 9eV) have enhancement effect on the analyte signal,and the heavier the analyte mass, the smaller the enhancement effects by Fl. The matrix elements Cu, In, Li, Na and Pb with lower ionization potential have suppression effect on the analyte signal. The heavier the matrix element mass, the more severe the suppression effects. The heavier the analyte mass, the smaller the suppression effects. The higher ionization potential of analyte, the more severe the suppression effects. Compared with continuous nebulization, the degree of suppression effect is smaller and the degree of the enhancement effect is larger by Fl.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent important applications of inductively coupled plasma mass spectrometry in biological samples analysis are reviewed. The sample preparation, sample introduction techniques, interference correction and typical applications are introduced in detail with 154 references.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An amperometric glucose biosensor was constructed based on a glassy carbon electrode modified with a Cobalt(II)hexacyanoferrate film which catalyzes electroreduction of hydrogen peroxide. Gelatin was used as immobilization matrix. Interference could be effectively eliminated by the combination of low detection potential with a Nafion coating. A low applied potential can avoid oxidation of interferences such as ascorbic acid, uric acid, p-acetyl-aminophenol, etc.. Nafion coating prevents interferences from access to the electrode surface by electrostatic repulsion. A wide linear range of detection was obtained. Analytical performance parameters are given and kinetic analysis discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Effects of some factors on the performance of our Kalman filter in discrimination of closely spaced overlapping signals were investigated. The resolution power of the filter for overlapping lines can be strengthened by reduction of the step size in scans. The minimum peak separation of two lines which the Kalman filter can effectively handle generally equals two to three times the step size in scans. Significant difference between the profiles of the analysis and interfering lines and multiple lines from matrix in the spectral window of the analysis line are very helpful for the Kalman filter to discern closely spaced analysis and interfering signals correctly, which allow the filter well to resolve the line pair with very small peak distance or even the entirely coincident lines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Correction of spectral overlap interference in inductively coupled plasma atomic emission spectrometry by factor analysis is attempted. For the spectral overlap of two known lines, a data matrix can be composed from one or two pure spectra and a spectrum of the mixture. The data matrix is decomposed into a spectra matrix and a concentration matrix by target transformation factor analysis. The component concentration of interest in a binary mixture is obtained from the concentration matrix and interference from the other component is eliminated. This method is applied to correcting spectral interference of yttrium on the determination of copper and aluminium: satisfactory results are obtained. This method may also be applied to correcting spectral overlap interference for more than two lines. Like other methods of correcting spectral interferences, factor analysis can only be used for additive spectral overlap. Results obtained from measurements on copper/yttrium mixtures with different white noise added show that random errors in measurement data do not significantly affect the results of the correction method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper deals with the evaluation of the reliability of the analytical results obtained by Kalman filtering. Two criteria for evaluation were compared: one is based on the autocorrelation analysis of the innovation sequence, the so-called NAC criterion; the other is the innovations number, which actually is the autocorrelation coefficient of the innovation sequence at the initial wavelength. Both criteria allow compensation for the wavelength positioning errors in spectral scans, but there exists a difference in the way they work. The NAC criterion can provide information about the reliability of an individual result, which is very useful for the indication of unmodelled emissions, while the innovations number should be incorporated with the normalization of the innovations or seek the help of the sequence itself for the same purpose. The major limitation of the NAC criterion is that it does not allow the theoretical modelling of continuous backgrounds, which, however, is convenient in practical analysis and can be taken with the innovations number criterion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work evaluates the effect of wavelength positioning errors in spectral scans on analytical results when the Kalman filtering technique is used for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). The results show that a positioning accuracy of 0.1 pm is required in order to obtain accurate and precise estimates for analyte concentrations. The positioning error in sample scans is more crucial than that in model scans. The relative bias in measured analyte concentration originating from a positioning error in a sample scan increases linearly with an increase in the magnitude of the error and the peak distance of the overlapping lines, but is inversely proportional to the signal-to-background ratio. By the use of an optimization procedure for the positions of scans with the innovations number as the criterion, the wavelength positioning error can be reduced and, correspondingly, the accuracy and precision of analytical results improved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the most attractive features of derivative spectrometry is its higher resolving power. In the present power, numerical derivative techniques are evaluated from the viewpoint of increase in selectivity, the latter being expressed in terms of the interferent equivalent concentration (IEC). Typical spectral interferences are covered, including flat background, sloped background, simple curved background and various types of line overlap with different overlapping degrees, which were defined as the ratio of the net interfering signal at the analysis wavelength to the peak signal of the interfering line. the IECs in the derivative spectra are decreased by one to two order of magnitudes compared to those in the original spectra, and in the most cases, assume values below the conventional detection limits. The overlapping degree is the dominant factor that determines whether an analysis line can be resolved from an interfering line with the derivative techniques. Generally, the second derivative technique is effective only for line overlap with an overlapping degree of less than 0.8. The effects of other factors such as line shape, data smoothing, step size and the intensity ratio of analyte to interferent on the performance of the derivative techniques are also discussed. All results are illustrated with practical examples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel labeling reagent 1-(2-naphthyl)-3-methyl-5-pyrazolone (NMP) coupling to liquid chromatography with electrospray ionization mass spectrometry for the detection of carbohydrates from the derivatized rape bee pollen samples is reported. Carbohydrates are derivatized to their bis-NMP-labeled derivatives. Derivatives showed an intense protonated molecular ion at m/z [M+H](+) in positive-ion detection mode. The mass-to-charge ratios of characteristic fragment ions at m/z 473.0 could be used for the accurately qualitative analysis of carbohydrates. This characteristic fragment ion is from the cleavage of C2-C3 bond in carbohydrate chain giving the specific fragment ions at m/z [MH-CmH2m+1Om-H2O](+) for pentose, hexose and glyceraldehydes and at m/z [MH-CmH2m-1Om+1-H2O](+) for alduronic acids such as galacturonic acid and glucuronic acid (m = n - 2, n is carbon number of carbohydrate). No interferences for all aliphatic and aromatic aldehydes presented in natural environmental samples were observed due to the highly specific parent mass-to-charge ratio and the characteristic fragment ions. The method, in conjunction with a gradient elution, offered a baseline resolution of carbohydrate derivatives on a reversed-phase Hypersil ODS-2 column. The carbohydrates such as mannose, galacturonic acid, glucuronic acid, rhamnose, glucose, galactose, xylose, arabinose and fucose can successfully be detected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim in Rb-Sr-REE-Pb isotopic analysis of river material, a single-stage, highly efficient and rapid chemical separation method of Rb-Sr-REE-Pb has been established by a combination of the SR special resin and the RE resin. At the same time, Feasibility of high precision analysis on micro-size Nd samples,which were chemically separated by using the LN resin, were systematicly studied using the NdO+ technique in thermal ionization mass spectrometer (TIMS). Results show that high precision measurement of Nd isotopic ratios can be successfully achieved on micro-sample of 1 ng size lever, by systematic experiments on isobar interferences and optimizing separation and measurement conditions. This method will greatly extend the application prospect of the NdO+ technique. Sr-Nd-Pb isotopic composition of suspending particle material (SPM) and sediment and Sr isotopic composition of river water in the low reaches of the Yellow Rriver have been systematically analysed in this study. Results can indicate followings: (1) relative stable Sr isotopic ratios around 0.7112 of river water suggest great influcence from dissolution of carbonate component of loss material on Sr isotopic composition of river water; (2) Nd isotopic compositions of SPM and sediment of the Yellow river are is similar, mean εNd value of SPM around -11.5 and mean εNd value of sediment -12.7, slightly lower than that of SPM. Nd isotopic composition of the Yellow River material is simarlar to or slightly lower than loss material (-9.5); (3) evidence of Sr and Pb isotopic compositions of both SPM and sediment reveals a mixing trend of two endmembers. Sr isotopic ratios of SPM after leaching are significantly different that those without leaching, possibly suggesting strong alteration of river water. Pb isotopic ratios of SPM remain unchangable after leaching compared with unleached SPM; (4) Pb-contents of SPM are commonly higher than those of sediments, while Pb isotopic ratios of SPM are significantly lower. Pb isotopic composition of the Yellow River is relatively constant, which can be a useful provenance indicator between the Changjiang and Yellow Rivers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous studies have witnessed some psychological or behavioral deviation (such as aggressive behavior) might have an association with cerebral hemisphere cooperative dysfunction, however, it is still unclear whether there is an association between individuals with social cognitive bias and their hemispheric cooperative functions especially while the interhemisphere cooperative processing is under the conditions of emotional interferences. The purpose of this study is to explore the differences between the social cognitive bias group and the normal group’s interhemispheric cooperative functional activity under the conditions of with or without interferences. Methods: According to Dodge’s (1993) model of “social-cognitive mechanisms in the development of conduct disorder and depression”, a 51 items of “social cognitive bias scale” was created and was used to screen the high score group. 20 male subjects was composed of high score group and other 23 matched the control group. Stimulus tachistoscopically presented to the bilateral visual field and compared with the central. Both group’s interhemispheric cooperative functional activity were observed and compared under the conditions of without interference- i.e. base level and with the emotional interferences of white noise level and negative evaluative feedback speech level while finishing: experiment one: Chinese word-figure Stroop analogue task; experiment two: two single Chinese Characters combination task. Heart rate and respiratory rate were simultaneously recorded as index of emotional changes. Results: ① The high score group showed a decrease in processing accuracy compared with the normal group under the condition of white noise interference level in experiment one. ② Still under the condition of white noise interference level, there were more reaction time and more errors were observed in high score group than normal in experiment two. ③ Both groups showed speed up effect and the strategic processing tendency of speed-accuracy trade-off effect under the condition of white noise interference level in both experiments. ④ Between group differences of interhemipheric cooperative function were not observed under the conditions of base level and the negative evaluative feedback speech level within both experiments. Conclusion: The results suggested that interhemispheric cooperative functional differences exists between the two groups, characterized as ① differences existed in interhemispheric cooperative processing strategy between the two groups, with the high score group presented “hierarchic” deficiency strategy. ② the appearance of the differences between the two groups were condition specified , and in this research it was only under the white noise interference condition. ③ the features of the differences between the two groups were the differences on multidimensional performances and with a deficit orientation in high score group. ④ the varieties of the differences were changing with cooperative tasks, as in this research the high score group performed worse in complementary cooperative task. In addition, both group adjusted the processing strategy respectively under the condition of white noise evoked emotional interference implied that the interaction between the interhemisphere cooperative processing and emotion might exist.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Ciências Farmacêuticas

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, The radio Frequency (RF) Monitoring and Measurement of the Environmental Research Institute (ERI) located in Cork city will be monitored and analyzed in both the Zigbee (2.44 GHz) and the industrial, scientific and medical (ISM 433 MHz). The main objective of this survey is to confirm what the noise and interferences threat signals exist in these bands. It was agreed that the surveys would be carried out in 5 different rooms and areas that are candidates for the Wireless Sensors deployments. Based on the carried on study, A Zigbee standard Wireless Sensor Network (WSN) will be developed employing a number of motes for sensing number of signals like temperature, light and humidity beside the RSSI and battery voltage monitoring. Such system will be used later on to control and improve indoor building climate at reduced costs, remove the need for cabling and both installation and operational costs are significantly reduced.