331 resultados para Hanover
Resumo:
Pathologic tooth migration related to periodontal disease is a common chief complaint of periodontal patients. This paper describes the treatment of a case of severe periodontal disease and disfiguring pathologic migration of maxillary central incisors, which required a multidisciplinary approach. After conventional pert. odontal treatment was performed, the anterior diastema was closed using a combination of orthodontic therapy and restorative treatment. A 6-month follow-up examination of this case revealed resolution of the anterior pathologic migration, with gains in clinical attachment levels and a successful esthetic and functional final result.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study compared the dimensions of gingival papillae in anterosuperior areas presenting at natural teeth (teeth sites) or single-tooth implants adjacent to natural teeth (implant-tooth sites) by analyzing determined distances. A total of 45 teeth and 46 implant-tooth sites were carefully selected. Clinical evaluation consisted of visual and quantitative analyses with millimeter grids on radiographs. Implant-tooth sites showed a smaller gingival papilla dimension than tooth sites (P < .01). Both evaluated distances (contact point to bone crest and between the roots of adjacent teeth or implant platform to root of adjacent tooth) in all groups significantly influenced the presence/absence of gingival papillae (P < .01). (Int J Periodontics Restorative Dent 2012;32:93-100.)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To evaluate the biomechanical fixation, bone-to-implant contact (BIC), and bone morphology of screw-type root-form implants with healing chambers with as-machined or dual acid-etched (DAE) surfaces in a canine model. Materials and Methods: The animal model included the placement of machined (n = 24) and DAE (n = 24) implants along the proximal tibiae of six mongrel dogs, which remained in place for 2 or 4 weeks. Following euthanasia, half of the specimens were subjected to biomechanical testing (torque to interface failure) and the other half were processed for histomorphologic and histomorphometric (%BIC) assessments. Statistical analyses were performed by one-way analysis of variance at the 95% confidence level and the Tukey post hoc test for multiple comparisons. Results: At 4 weeks, the DAE surface presented significantly higher mean values for torque to interface failure overall. A significant increase in %BIC values occurred for both groups over time. For both groups, bone formation through the classic appositional healing pathway was observed in regions where intimate contact between the implant and the osteotomy walls occurred immediately after implantation. Where contact-free spaces existed after implantation (healing chambers), an intramembranous-like healing mode with newly formed woven bone prevailed. Conclusions: In the present short-term evaluation, no differences were observed in BIC between groups; however, an increase in biomechanical fixation was seen from 2 to 4 weeks with the DAE surface. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:75-82
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective: To assess the effect of metal conditioners on the bond strength between resin cements and cast titanium. Method and Materials: Commercially pure titanium (99.56%) was cast using an arc casting machine. Surfaces were finished with 400-grit silicon carbide paper followed by air abrasion with 50-mu m aluminum oxide. A piece of double-coated tape with a 4-mm circular hole was then positioned on the metal surface to control the area of the bond. The prepared surfaces were then divided into 4 groups (n=10): G1, unprimed Panavia F; G2, Alloy Primer-Panavia F; G3, unprimed Bistite DC; G4, Metaltite-Bistite DC. Forty minutes after insertion of the resin cements, the specimens were detached from the mold and stored in water at 37 C for 24 hours. Shear bond strength was performed in a testing machine (MTS 810) at a crosshead speed of 0.5 mm/min. Data were analyzed using ANOVA and Tukey's test with a .05 significance level. The fractured surfaces were observed through an optical microscope at 10x magnification. Results: the G1 group demonstrated significantly higher shear bond strength (17.95 MPa) than the other groups. G3 (13.79 MPa) and G4 (12.98 MPa) showed similar mean values to each other and were statistically superior to G2 (9.31 MPa). Debonded surfaces generally presented adhesive failure between metal surfaces and resin cements. Conclusion: While the Metaltite conditioner did not influence the bond strength of the Bistite DC cement, the Alloy Primer conditioner significantly decreased the mean bond strength of the Panavia F cement.
Resumo:
Aims: To estimate the prevalence of symptoms of temporomandibular disorders (TMD) as a function of age and gender, in a representative urban sample from the Brazilian population. Methods: A total of 1,230 inhabitants (51.5% women) aged 15 to 65 years were interviewed by a validated phone survey. Sample size had been previously calculated. TMD symptoms were assessed through five questions, as recommended by the American Academy of Orofacial Pain, in an attempt to identify possible TMD. Data were derived by age and gender. Prevalence of each TMD symptom, and of combination of symptoms, was calculated. Results: At least one TMD symptom was reported by 39.2% of the individuals. Pain related to TMD was noted by 25.6% of the population. Temporomandibular joint (TMJ) sound was the most common symptom of TMD, followed by TMJ pain and masticatory muscle pain. All symptoms were more prevalent in women than in men. With men used as the reference, a relative risk (RR) of at least one TMD symptom in women was 1.31 (95% confidence interval [CI] = 1.14 to 1.52). When at least two symptoms were present, the RR was 1.93 (95% CI = 1.49 to 2.51). For three or more TMD symptoms, the RR was 2.49 (95% CI = 1.67 to 3.71). Women were also more likely than men to have TMD pain (RR = 1.78; 9% CI = 1.45 to 2.18). Conclusion: Individual symptoms, as well as a combination of TMD symptoms, are prevalent in the Brazilian urban population and are more frequent in women than in men. Additional studies should focus on risk factors for and relevance of TMD for the sufferers. J OROFAC PAIN 2010;24:270-278
Resumo:
This study evaluated factors that may influence the presence or absence of interproximal papillae. Clinical evaluation consisted of visual determination, and quantitative analyses were made using millimeter grids on radiographs. Patients (n = 45) were divided into three groups according to age. Data were analyzed using the chi-square test followed by the Student t test (alpha = .05). The distance from the contact point to the bone crest had significant influence on papilla presence in both anterior and posterior sites (P < .05), whereas the width between roots of adjacent teeth did not. The papilla was missing more frequently in anterior sites. The presence of papillae was not age-dependent. (Int J Periodontics Restorative Dent 2012;32:e68-e74.)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: Different surface treatments have been developed in attempts to prevent the loosening of abutment screws. The aim of the current study was to compare the effectiveness of titanium alloy screws with tungsten-doped diamond-like carbon (W-DLC) coating and uncoated screws in providing stability to zirconia (ZrO2) ceramic abutments after cyclic loading. Materials and Methods: Twenty prefabricated ZrO2 ceramic abutments on their respective external-hex implants were divided into two groups of equal size according to the type of screw used: uncoated titanium alloy screw (Ti) or titanium alloy screw with W-DLC coating (W-DLC/Ti). The removal torque value (preload) of the abutment screw was measured before and after loading. Cyclic loading between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants at a frequency of 15 Hz. A target of 0.5 x 10(6) cycles was defined. Group means were calculated and compared using analysis of variance and the F test (alpha=.05). Results: Before cyclic loading, the preload for Ti screws was significantly higher than that for W-DLC/Ti screws (P=.021). After cyclic loading, there was no significant difference between them (P=.499). Conclusions: Under the studied conditions, it can be concluded that, after cyclic loading, both abutment screws presented a significant reduction in the mean retained preload and similar effectiveness in maintaining preload. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:1061-1067
Resumo:
Objectives: To evaluate the effect of microwave disinfection on the flexural strength and Vickers hardness of 4 autopolymerized resins (Kooliner [K], Tokuso Rebase Fast [T], Ufi Gel Hard [U], and New Truliner [N]) and 1 denture base resin (Lucitone 550 [L]). Method and Materials: For each material, 48 specimens (64 x 10 x 3.3 mm) were made and divided into 6 equal groups (n = 8). In the control group, specimens were untreated. Before testing, specimens were immersed in 200 mL of distilled water and submitted to disinfection for 1 of the following irradiation times: 1, 2, 3, 4, or 5 minutes. The irradiation procedure was performed twice. The flexural strength was determined using a testing machine MTS-810 and measurements of Vickers hardness were made on Micromet 2100. The values were submitted to ANOVA and Tukey's test (P = .05). Results: The K material showed a significant increase (P = .0010) in flexural strength following 5 minutes of disinfection compared to control specimens. The flexural strength mean values of materials T, U, and N were not significantly affected (P > .05) by disinfection. Compared to the control group, the K material showed a significant increase in hardness (P < .001) following disinfection for 3, 4, and 5 minutes. For material U, disinfection for 4 and 5 minutes produced specimens with significantly increased hardness values (P < .001) compared to the control group. For material N, disinfection for 5 minutes resulted in significantly higher hardness values (P < .001) than the control group. Conclusion: Regardless of the irradiation time, the flexural strength and hardness of the materials evaluated were not detrimentally affected by microwave disinfection. (Quintessence Int 2008;39:833-840)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)