Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
20/05/2014
20/05/2014
01/11/2008
|
Resumo |
Objectives: To evaluate the effect of microwave disinfection on the flexural strength and Vickers hardness of 4 autopolymerized resins (Kooliner [K], Tokuso Rebase Fast [T], Ufi Gel Hard [U], and New Truliner [N]) and 1 denture base resin (Lucitone 550 [L]). Method and Materials: For each material, 48 specimens (64 x 10 x 3.3 mm) were made and divided into 6 equal groups (n = 8). In the control group, specimens were untreated. Before testing, specimens were immersed in 200 mL of distilled water and submitted to disinfection for 1 of the following irradiation times: 1, 2, 3, 4, or 5 minutes. The irradiation procedure was performed twice. The flexural strength was determined using a testing machine MTS-810 and measurements of Vickers hardness were made on Micromet 2100. The values were submitted to ANOVA and Tukey's test (P = .05). Results: The K material showed a significant increase (P = .0010) in flexural strength following 5 minutes of disinfection compared to control specimens. The flexural strength mean values of materials T, U, and N were not significantly affected (P > .05) by disinfection. Compared to the control group, the K material showed a significant increase in hardness (P < .001) following disinfection for 3, 4, and 5 minutes. For material U, disinfection for 4 and 5 minutes produced specimens with significantly increased hardness values (P < .001) compared to the control group. For material N, disinfection for 5 minutes resulted in significantly higher hardness values (P < .001) than the control group. Conclusion: Regardless of the irradiation time, the flexural strength and hardness of the materials evaluated were not detrimentally affected by microwave disinfection. (Quintessence Int 2008;39:833-840) |
Formato |
833-840 |
Identificador |
http://www.quintpub.com/journals/qi/abstract.php?article_id=3559#.UjDRzsZwp5I Quintessence International. Hanover Park: Quintessence Publishing Co Inc, v. 39, n. 10, p. 833-840, 2008. 0033-6572 http://hdl.handle.net/11449/16473 WOS:000261138100007 |
Idioma(s) |
eng |
Publicador |
Quintessence Publishing Co Inc |
Relação |
Quintessence International |
Direitos |
closedAccess |
Palavras-Chave | #acrylic resins #cross infection #disinfection #flexural strength #hardness #microwave |
Tipo |
info:eu-repo/semantics/article |