216 resultados para HOA microphone
Resumo:
Marked elevation of dioxin associated with the herbicide Agent Orange was recently found in 19 of 20 blood samples from persons living in Bien Hoa, a large city in southern Vietnam. This city is located near an air base that was used for Agent Orange spray missions between 1962 and 1970. A spill of Agent Orange occurred at this air base more than 30 years before blood samples were collected in 1999. Samples were collected, frozen, and sent to a World Health Organization-certified dioxin laboratory fm congener-specific analysis as part of a Vietnam Red Cross project. Previous analyses of more than 2200 pooled blood samples collected in the 1990s identified Bien Hoa as one of several southern Vietnam areas with persons having elevated blood dioxin levels from exposure to Agent Orange. In sharp contrast to this study, our previous research showed decreasing tissue dioxin levels over time since 1970. Only the dioxin that contaminated Agent Orange, 2,3, 7, 8-tetrachlmodibenzo-p-dioxin (TCDD), was elevated in the blood of 19 of 20 persons sampled from Bien Hoa. A comparison pooled sample from 100 residents of Hanoi, where Agent Orange was not used, measured blood TCDD levels of 2 parts per trillion (ppt). TCDD levels of up to 271 ppt, a 135-fold increase, were found in Bien Hoa residents. TCDD contamination was also found in some nearby soil and sediment samples. Persons new to this region and children born after Agent Orange spraying ended also had elevated TCDD levels. This TCDD uptake was recent and occurred decades after spraying ended. We hypothesize that a major route of current and past exposures is from the movement of dioxin from soil into river sediment, then into fish, and from fish consumption into people.
Resumo:
Cervical auscultation is in the process of gaining clinical credibility. In order for it to be accepted by the clinical community, the procedure and equipment used must first be standardized. Takahashi et al. [Dysphagia 9:54-62, 1994] attempted to provide benchmark methodology for administering cervical auscultation. They provided information about the acoustic detector unit best suited to picking up swallowing sounds and the best cervical site to place it. The current investigation provides contrasting results to Takahashi et al. with respect to the best type of acoustic detector unit to use for detecting swallowing sounds. Our study advocates an electret microphone as opposed to an accelerometer for recording swallowing sounds. However, we agree on the optimal placement site. We conclude that cervical auscultation is within reach of the average dysphagia clinic.
Resumo:
Polissema: Revista de Letras do ISCAP 2001/N.º 1- Tradução
Resumo:
This paper reports on the creation of an interface for 3D virtual environments, computer-aided design applications or computer games. Standard computer interfaces are bound to 2D surfaces, e.g., computer mouses, keyboards, touch pads or touch screens. The Smart Object is intended to provide the user with a 3D interface by using sensors that register movement (inertial measurement unit), touch (touch screen) and voice (microphone). The design and development process as well as the tests and results are presented in this paper. The Smart Object was developed by a team of four third-year engineering students from diverse scientific backgrounds and nationalities during one semester.
Resumo:
Este documento foi redigido no âmbito da Tese, do Mestrado em Engenharia Informática na área de Tecnologias do Conhecimento e Decisão, do Departamento de Engenharia Informática, do ISEP, cujo tema é classificação de sons cardíacos usando motifs. Neste trabalho, apresenta-se um algoritmo de classificação de sons cardíacos, capaz de identificar patologias cardíacas. A classificação do som cardíaco é um trabalho desafiante dada a dificuldade em separar os sons ambiente (vozes, respiração, contacto do microfone com superfícies como pele ou tecidos) ou de ruído dos batimentos cardíacos. Esta abordagem seguiu a metodologia de descoberta de padrões SAX (motifs) mais frequentes, em séries temporais relacionando-os com a ocorrência sistólica (S1) e a ocorrência diastólica (S2) do coração. A metodologia seguida mostrou-se eficaz a distinguir sons normais de sons correspondentes a patologia. Os resultados foram publicados na conferência internacional IDEAS’14 [Oliveira, 2014], em Julho deste ano. Numa fase seguinte, desenvolveu-se uma aplicação móvel, capaz de captar os batimentos cardíacos, de os tratar e os classificar. A classificação dos sons é feita usando o método referido no parágrafo anterior. A aplicação móvel, depois de tratar os sons, envia-os para um servidor, onde o programa de classificação é executado, e recebe a resposta da classificação. É também descrita a arquitetura aplicacional desenhada e as componentes que a constituem, as ferramentas e tecnologias utilizadas.
Resumo:
Purpose: To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Methods: Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-pointtouch fitting approach. The lens’ back optic zone radius (BOZR) was 0.4 mm and 0.1 mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. Results: A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p < 0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p < 0.05). Significant reduction was found over time in CCA (p = 0.001) and anterior corneal asphericity in both groups (p < 0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p < 0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p < 0.05). Conclusion: Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apicaltouch was associated with greater corneal flattening in comparison to three-point-touch lens wear.
Resumo:
En aquest projecte s'ha investigat i desenvolupat una eina per a la detecció de falles mecàniques en entorns controlats. Aquest programa analitza l'espectre dels senyals acústics aconseguits mitjançant el micròfon del PC i n'estudia estadísticament les propietats –mitjana i desviació estàndard- per tal de poder diferenciar els nous senyals que capturi. S'ha experimentat amb el cas real d'un motor de corrent continu i s'han obtingut resultats de més del 90% d'encert a l'hora de detectar el seu estat.
Resumo:
Upper bounds for the Betti numbers of generalized Cohen-Macaulay ideals are given. In particular, for the case of non-degenerate, reduced and ir- reducible projective curves we get an upper bound which only depends on their degree.
Resumo:
Biometric system performance can be improved by means of data fusion. Several kinds of information can be fused in order to obtain a more accurate classification (identification or verification) of an input sample. In this paper we present a method for computing the weights in a weighted sum fusion for score combinations, by means of a likelihood model. The maximum likelihood estimation is set as a linear programming problem. The scores are derived from a GMM classifier working on a different feature extractor. Our experimental results assesed the robustness of the system in front a changes on time (different sessions) and robustness in front a change of microphone. The improvements obtained were significantly better (error bars of two standard deviations) than a uniform weighted sum or a uniform weighted product or the best single classifier. The proposed method scales computationaly with the number of scores to be fussioned as the simplex method for linear programming.
Resumo:
In this paper we propose the inversion of nonlinear distortions in order to improve the recognition rates of a speaker recognizer system. We study the effect of saturations on the test signals, trying to take into account real situations where the training material has been recorded in a controlled situation but the testing signals present some mismatch with the input signal level (saturations). The experimental results for speaker recognition shows that a combination of several strategies can improve the recognition rates with saturated test sentences from 80% to 89.39%, while the results with clean speech (without saturation) is 87.76% for one microphone, and for speaker identification can reduce the minimum detection cost function with saturated test sentences from 6.42% to 4.15%, while the results with clean speech (without saturation) is 5.74% for one microphone and 7.02% for the other one.
Resumo:
In this paper we propose the inversion of nonlinear distortions in order to improve the recognition rates of a speaker recognizer system. We study the effect of saturations on the test signals, trying to take into account real situations where the training material has been recorded in a controlled situation but the testing signals present some mismatch with the input signal level (saturations). The experimental results shows that a combination of several strategies can improve the recognition rates with saturated test sentences from 80% to 89.39%, while the results with clean speech (without saturation) is 87.76% for one microphone.
Resumo:
El projecte està basat en la creació d'una aplicació per dispositius mòbils android i que fent servir l'ús del micròfon capturi el so que genera l'usuari i pugui determinar si s'està respirant i en quin punt de la respiració es troba l'usuari. S'ha dut a terme una filosofia de disseny orientada a l'usuari (DCU) de manera que el primer pas ha sigut realitzar un prototip i un 'sketch'. A continuació, s'han realitzat 10 aplicacions test i en cadascuna d'elles s'ha ampliat la funcionalitat fins a arribar a obtenir una aplicació base que s'aproxima al disseny inicial generat per mitjà del prototip. El més important dels dissenys algorísmics que s'han realitzat per la aplicació es la capacitat de processar el senyal en temps real, ja que fins i tot s'ha pogut aplicar la transformada ràpida de Fourier (FFT) en temps real sense que el rendiment de l'aplicació es veies afectat. Això ha sigut possible gràcies al disseny del processament amb doble buffer i amb un fil d'execució dedicat independent del fil principal d'execució del programa 'UI Thread'
Resumo:
Aquest projecte treballa sobre la possibilitat d'aplicar tècniques d'enregistrament binaural en animals, en concret, en una cabra domèstica. Mitjançant uns micròfons col·locats dins les seves orelles i una petita càmera de vídeo muntada sobre el seu cap, s'obté un material audiovisual que permet fer-se una idea aproximada de com és la seva percepció del món. En base a un estudi de cognició comparada, es pretén trobar maneres de transformar els enregistraments obtinguts per tal d'adaptar el marc psicoacústic humà al de l'animal. L'objectiu és que una persona pugui sentir com ho fa un animal, encara que sigui d'una manera aproximada. Els materials obtinguts al llarg dels enregistraments són el punt de partida per a la construcció de paisatges sonors i peces audiovisuals diverses. Així doncs, el treball s'inicia amb el disseny i construcció d'un micròfon binaural, continua amb enregistraments de camp en animals i acaba amb l'edició, el processat i la composició dels paisatges sonors finals.