993 resultados para Gadolinium
Resumo:
This work reports on the synthesis and characterization of a new complex of Eu(3+) with the 3-hydroxypicolinamide ligand (Hhpa). Here we present an approach for obtaining bis[2-carbamoyl(kappa O)pyridin-3-olato(kappa O`)] lanthanide complexes, which were characterized through elemental analysis, thermal analysis, infrared and photoluminescence spectroscopies (emission, excitation, luminescence lifetimes, quantum efficiencies, Judd-Ofelt parameters and quantum yields). Although hpa can act as a bidentate ligand in different conformations, the results attest for the occurrence of a unique coordination site of low symmetry for the Eu(3+) ions, in which two anionic hpa ligands coordinate the cations through an O/O chelating system. The phosphorescence of the synthesized gadolinium complex provides the energy of the triplet state, which is determined to be at 20,830 cm(-1) over the ground state. This makes the Hhpa ligand very adequate for sensitizing the Eu(3+) luminescence, which leads to a very efficient antenna effect and opens a wide range of applications for the complex in light emitting organic-inorganic devices.
Resumo:
The synthesis and structures of two new isostructural mononuclear [Ln(L)(NO(3))(H(2)O)(3)](NO(3))(2) complexes, with Ln = Tb (complex 1) and Eu (complex 2), which display high activity in the hydrolysis of the substrate 2,4-bis(dinitrophenyl)phosphate, are reported. These complexes displayed catalytic behavior similar to the mononuclear gadolinium complex [Gd(L)(NO(3))(H(2)O)(3)](NO(3))(2) previously reported by us (lnorg. Chem. 2008, 47, 2919-2921); one hydrolysis reaction in two stages where the diesterase and monoesterase activities could be monitored separately, with the first stage dependent on and the second independent of the complex concentration. Through potentiometric studies, electrospray ionization mass spectrometry (ESI-MS) analysis, and determination of the kinetic behaviors of 1 and 2 in acetonitrile/water solution, the species present in solution could be identified and suggested a dinuclear species, with one hydroxo group, as the most prominent catalyst under mild conditions. The complexes show high activity (k(1)= 7 and 18 s(-1) for 1 and 2, respectively) and catalytic efficiency. Complexes 1 and 2 were found to be active toward the cleavage of plasmid DNA, and complete kinetic studies were carried out. Studies with a radical scavenger (dimethylsulfoxide) confirmed the hydrolytic action of 1 and 2 in the cleavage of DNA. Studies on the incubation of distamycin with plasmid DNA suggested that 1 and 2 are regio-specific, interacting with the minor groove of DNA. These complexes displayed luminescent properties. Complex 1 showed higher emission intensity than 2 due to a more efficient energy transfer between triplet and emission levels of terbium (T -> (5)D(4)), along with nonradiative deactivation mechanisms of the excited states of europium via multiphonon decays and the ligand-to-metal charge transfer state. Lifetime measurements of the (5)D(4) and (5)D(0) excited levels for 1 and 2, respectively, indicated the numbers of coordinated water molecules for the complexes.
Resumo:
Objectives We sought to determine whether the quantitative assessment of myocardial fibrosis (MF), either by histopathology or by contrast-enhanced magnetic resonance imaging (ce-MRI), could help predict long-term survival after aortic valve replacement. Background Severe aortic valve disease is characterized by progressive accumulation of interstitial MF. Methods Fifty-four patients scheduled to undergo aortic valve replacement were examined by ce-MRI. Delayed-enhanced images were used for the quantitative assessment of MF. In addition, interstitial MF was quantified by histological analysis of myocardial samples obtained during open-heart surgery and stained with picrosirius red. The ce-MRI study was repeated 27 +/- 22 months after surgery to assess left ventricular functional improvement, and all patients were followed for 52 +/- 17 months to evaluate long-term survival. Results There was a good correlation between the amount of MF measured by histopathology and by ce-MRI (r = 0.69, p < 0.001). In addition, the amount of MF demonstrated a significant inverse correlation with the degree of left ventricular functional improvement after surgery (r = -0.42, p = 0.04 for histopathology; r = -0.47, p = 0.02 for ce-MRI). Kaplan-Meier analyses revealed that higher degrees of MF accumulation were associated with worse long-term survival (chi-square = 6.32, p = 0.01 for histopathology; chi-square = 5.85, p = 0.02 for ce-MRI). On multivariate Cox regression analyses, patient age and the amount of MF were found to be independent predictors of all-cause mortality. Conclusions The amount of MF, either by histopathology or by ce-MRI, is associated with the degree of left ventricular functional improvement and all-cause mortality late after aortic valve replacement in patients with severe aortic valve disease. (J Am Coll Cardiol 2010; 56: 278-87) (c) 2010 by the American College of Cardiology Foundation
Resumo:
Purpose: The purpose of our study was to compare signal characteristics and image qualities of MR imaging at 3.0 T and 1.5 T in patients with diffuse parenchymal liver disease. Materials and methods: 25 consecutive patients with diffuse parenchymal liver disease underwent abdominal MR imaging at both 3.0 T and 1.5 T within a 6-month interval. A retrospective study was conducted to obtain quantitative and qualitative data from both 3.0 T and 1.5 T MRI. Quantitative image analysis was performed by measuring the signal-to-noise ratios (SNRs) and the contrast-to-noise ratios (CNRs) by the Students t-test. Qualitative image analysis was assessed by grading each sequence on a 3- and 4-point scale, regarding the presence of artifacts and image quality, respectively. Statistical analysis consisted of the Wilcoxon signed-rank test. Results: the mean SNRs and CNRs of the liver parenchyma and the portal vein were significantly higher at 3.0 T than at 1.5 T on portal and equilibrium phases of volumetric interpolated breath-hold examination (VIBE) images (P < 0.05). The mean SNRs were significantly higher at 3.0 T than at 1.5 T on T1-weighted spoiled gradient echo (SGE) images (P < 0.05). However, there were no significantly differences on T2-weighted short-inversion-time inversion recovery (STIR) images. Overall image qualities of the 1.5 T noncontrast T1- and T2-weighted sequences were significantly better than 3.0 T (P < 0.01). In contrast, overall image quality of the 3.0 T post-gadolinium VIBE sequence was significantly better than 1.5 T (P< 0.01). Conclusions: MR imaging of post-gadolinium VIBE sequence at 3.0 T has quantitative and qualitative advantages of evaluating for diffuse parenchymal liver disease. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Background Autologous non-myeloablative haemopoietic stem cell transplantation is a method to deliver intense immune suppression. We evaluated the safety and clinical outcome of autologous non-myeloablative haemopoietic stem cell transplantation in patients with retapsing-remitting multiple sclerosis (MS) who had not responded to treatment with interferon beta. Methods Eligible patients had relapsing-remitting MS, attended Northwestern Memorial Hospital, and despite treatment with interferon beta had had two corticosteroid-treated relapses within the previous 12 months, or one relapse and gadolinium-enhancing lesions seen on MRI and separate from the relapse. Peripheral blood haemopoietic stem cells were mobilised with 2 g per m(2) cyclophosphamide and 10 mu g per kg per day filgrastim. The conditioning regimen for the haemopoietic stem cells was 200 mg per kg cyclophosphamide and either 20 mg alemtuzumab or 6 mg per kg rabbit antithymocyte globulin. Primary outcomes were progression-free survival and reversal of neurological disability at 3 years post-transplantation. We also sought to investigate the safety and tolerability of autologous non-myeloablative haemopoietic stem cell transplantation. Findings Between January 2003, and February, 2005, 21 patients were treated. Engraftment of white blood cells and platelets was on median day 9 (range day 8-11) and patients were discharged from hospital on mean day 11 (range day 8-13). One patient had diarrhoea due to Clostridium difficile and two patients had dermatomal zoster. Two of the 17 patients receiving alemtuzumab developed late immune thrombocytopenic purpura that remitted with standard therapy. 17 of 21 patients (81%) improved by at least 1 point on the Kurtzke expanded disability status scale (EDSS), and five patients (24%) relapsed but achieved remission after further immunosuppression. After a mean of 37 months (range 24-48 months), all patients were free from progression (no deterioration in EDSS score), and 16 were free of relapses. Significant improvements were noted in neurological disability, as determined by EDSS score (p<0.0001), neurological rating scale score (p=0.0001), paced auditory serial addition test (p=0.014), 25-foot walk (p<0.0001), and quality of life, as measured with the short form-36 (SF-36) questionnaire (p<0.0001). Interpretation Non-myeloablative autologous haemopoietic stem cell transplantation in patients with relapsing-remitting MS reverses neurological deficits, but these results need to be confirmed in a randomised trial.
Resumo:
Purpose: To evaluate the diagnostic image quality of post-gadolinium water excitation-magnetization-prepared rapid gradient-echo (WE-MPRAGE) sequence in abdominal examinations of noncooperative patients at 1.5 Tesla (T) and 3.0T MRI. Materials and Methods: Eighty-nine consecutive patients (48 males and 41 females; mean age +/- standard deviation, 54.6 +/- 16.6 years) who had MRI examinations including postgadolinium WE-MPRAGE were included in the study. Of 89 patients, 33 underwent noncooperative protocol at 1.5T. 10 under-went noncooperative protocol at 3.0T, and 46 underwent cooperative protocol at 3.0T. Postgadolinium WE-MPRAGE, MPRAGE, and three-dimensional gradient-echo sequences of these three different groups were qualitatively evaluated for image quality, extent of artifacts, lesion conspicuity, and homogeneity of fat-attenuation by two reviewers retrospectively, independently, and blindly. The results were compared using Wilcoxon signed rank and Mann-Whitney U tests. Kappa statistics were used to measure the extent of agreement between the reviewers. Results: The average scores indicated that the images were diagnostic for WE-MPRAGE at 1.5T and 3.0T in noncooperative patients. WE-MPRAGE achieved homogenous fat-attenuation in 31/33 (94%) of noncooperative patients at 1.5T and 10/10 (100%) of noncooperative patients at 3.0T. WE-MPRAGE at 3.0T had better results for image quality, extent of artifacts, lesion conspicuity and homogeneity of fat-attenuation compared with WE-MPRAGE at 1.5T. in noncooperative patients (P = 0.0008, 0.0006, 0.0024, and 0.0042: respectively). Kappa statistics varied between 0.76 and 1.00, representing good to excellent agreement. Conclusion: WE-MPRAGE may be used as a T1-weighted postgadolinium fat-attenuated sequence in noncooperative patients, particularly at 3.0T MRI.
Resumo:
Osteoarthritis (OA) is the most frequent form of arthritis, with major implications for individual and public health care without effective treatment available. The field of joint imaging, and particularly magnetic resonance (MR) imaging, has evolved rapidly owing to technical advances and the application of these to the field of clinical research. Cartilage imaging certainly is at the forefront of these developments. In this review, the different aspects of OA imaging and cartilage assessment, with an emphasis on recent advances, will be presented. The current role of radiography, including advances in the technology for joint space width assessment, will be discussed. The development of various MR imaging techniques capable of facilitating assessment of cartilage morphology and the methods for evaluating the biochemical composition of cartilage will be presented. Advances in quantitative morphologic cartilage assessment and semiquantitative whole-organ assessment will be reviewed. Although MR imaging is the most important modality in imaging of OA and cartilage, others such as ultrasonography play a complementary role that will be discussed briefly.
Resumo:
Purpose: To quantitatively evaluate changes induced by the application of a femoral blood-pressure cuff (BPC) on run-off magnetic resonance angiography (MRA). which is a method generally previously proposed to reduce venous contamination in the leg. Materials and Methods: This study was Health Insurance Portability and Accountability Act (HIPAA)- and Institutional Review Board (IRB)-compliant, We used time-resolved gradient-echo gadolinium (Gd)-enhanced MRA to measure BPC effects on arterial, venous, and soft-tissue enhancement. Seven healthy volunteers (six men) were studied with the BPC applied at the mid-femoral level unilaterally using a 1.5T MR system after intravenous injection of Gd-BOPTA. Different statistical tools were used such as the Wilcoxon signed rank test and a cubic smoothing spline fit. Results: We found that BPC application induces delayed venous filling (as previously described), but also induces significant decreases in arterial inflow, arterial enhancement, vascular-soft tissue contrast, and delayed peak enhancement (which have not been previously measured). Conclusion: The potential benefits from using a BPC for run-off MRA must be balanced against the potential pitfalls, elucidated by our findings.
Resumo:
Magnetic resonance (MR) imaging is the most important imaging modality for the evaluation of traumatic or degenerative cartilaginous lesions in the knee. It is a powerful noninvasive tool for detecting such lesions and monitoring the effects of pharmacologic and surgical therapy. The specific MR imaging techniques used for these purposes can be divided into two broad categories according to their usefulness for morphologic or compositional evaluation. To assess the structure of knee cartilage, standard spin-echo (SE) and gradient-recalled echo (GRE) sequences, fast SE sequences, and three-dimensional SE and GRE sequences are available. These techniques allow the detection of morphologic defects in the articular cartilage of the knee and are commonly used in research for semiquantitative and quantitative assessments of cartilage. To evaluate the collagen network and proteoglycan content in the knee cartilage matrix, compositional assessment techniques such as T2 mapping, delayed gadolinium-enhanced MR imaging of cartilage (or dGEMRIC), T1 rho imaging, sodium imaging, and diffusion-weighted imaging are available. These techniques may be used in various combinations and at various magnetic field strengths in clinical and research settings to improve the characterization of changes in cartilage. (C)RSNA, 2011 , radiographics.rsna.org
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Ressonância Magnética
Resumo:
O trabalho descrito no presente documento reporta a preparação de derivados tetrapirrólicos iodados de tipo porfirina tornando-os potenciais veículos a meio de contraste iodado, usado em radiodiagnóstico. Com os resultados deste trabalho irá ser realizado um pedido de patente das moléculas e portanto, o acesso a este trabalho será restrito nos termos do Código da Propriedade Industrial, aprovado pelo Decreto de Lei nº 36/2003 de 5 de Março. Na primeira fase do trabalho, foi sintetizado o derivado porfirínico simétrico, meso-substituído, contendo um total de 8 iodos. Este foi preparado por condensação do pirrol e do aldeído iodado em meio ácido e na presença de nitrobenzeno. Foram ainda preparados as respetivas metaloporfirinas contendo os iões metálicos de manganês e gadolínio. Posteriormente foi avaliada a capacidade destes derivados atenuarem o feixe de raio-X, através da mediação das Unidades de Hounsfield, após serem adquiridas imagens por Tomografia Computorizada. Na segunda fase do trabalho procedeu-se ao estudo da influência destes compostos na diferenciação celular, usando como modelo as células de pré-adipócitos 3T3-L1. Foi avaliada a diferenciação celular, através da quantificação de lípidos das células maduras, marcados com Red Oil O, por espectrofotometria de Visível 3 e 10 dias após a administração dos derivados em estudo.
Resumo:
Objectivos: Avaliar a possibilidade de realizar angiografia de alta resolução com reconstrução tridimensional, com recurso a equipamento de ressonância magnética de 1 Tesla, em doentes com patologia aórtica. Métodos: Efectuaram-se trinta e um exames de ressonâncias magnética em dezassete doentes, após administração, sob a forma de bolus, de gadolinium. Foram adquiridas imagens em spin echo rápido, gradiente echo e angiografia com time-of-flight. Resultados: Todas as aquisições foram bem toleradas e conseguiu-se a opacificação do lumen aórtico, no momento apropriado, em todos os doentes. As sequências angiográficas foram obtidas com respiração suspensa que requereu cerca de 25 segundos por imagem e seis a oito minutos para conseguir uma reconstrução tridimensional. Conclusão: A angiografia aórtica por reconstrução tridimensional é possível com um equipamento de 1 Tesla, com imagens de elevada qualidade e resolução, obtidas em pouco minutos. É possível obter toda a informação facultada pela aquisição em spin echo, convencional ou acelerado, a partir da reconstrução das imagens tridimensionais, afastando assim a necessidade de aquisição, tão incómoda, das imagens spin echo, melhorar a rapidez e diminuir, portanto, o tempo de aquisição, o que se torna relevante em doentes com síndromes aórticos agudos.
Resumo:
OBJECTIVES: To assess the feasibility of performing pulmonary angiography using MRI with contrast enhancement in patients with pulmonary vascular disease. METHODS: We present our experience in ten individuals, two controls and eight patients who underwent the exam after injection of a gadolinium-based contrast agent on a 1 Tesla MR scanner using a time-of-flight sequence and breath-holding during injection of contrast. RESULTS: Pathology in the main pulmonary artery and its major branches was detected easily while resolution at the segmental and subsegmental levels was inadequate. CONCLUSION: Contrast-enhanced magnetic resonance pulmonary angiography is feasible on a 1 Tesla MR scanner for the study of pathology of the main pulmonary artery and its major branches, like massive pulmonary embolism. However its ability to detect and define distal vessel pathology as found in chronic thromboembolic pulmonary hypertension and small pulmonary emboli is limited.
Resumo:
O controlo da qualidade em ressonância magnética (RM) passa pela realização de diversos testes ao equipamento e calibrações diárias, onde os fantomas desempenham um papel fundamental. Este trabalho teve como objetivo principal o desenvolvimento de um fantoma cerebral para um sistema de RM de intensidade 3.0 Tesla. Com base na literatura existente, escolheram-se como reagentes o cloreto de gadolínio (III) (GdCl3), a agarose, e o gelificante carragena, tendo sido ainda acrescentado o conservante químico azida de sódio (NaN3) de forma a inibir a degradação da solução. Realizaram-se vários testes com diferentes concentrações dos materiais selecionados até obter as misturas adequadas a suscetibilidade magnética das substâncias branca e cinzenta cerebrais. Os tempos de relaxação T1 das diversas substâncias desenvolvidas foram medidos, apresentando o fantoma final uns tempos de T1 de 702±10 ms, quando a concentração de GdCl3 foi de 100 µmol (substância branca) e 1179±23 ms quando a concentração foi de 15 µmol (substância cinzenta). Os valores de T1 do fantoma foram comparados estatisticamente com os tempos de relaxação conseguidos a partir de um cérebro humano, obtendo-se uma correlação de 0.867 com significância estatística. No intuito de demonstrar a aplicabilidade do fantoma, este foi sujeito a um protocolo de RM, do qual constaram as sequências habitualmente usadas no estudo cerebral. Como principais resultados constatou-se que, nas sequências ponderadas em T1, o fantoma apresenta uma forte associação positiva (rs > 0.700 p = 0.072) com o cérebro de referência, ainda que não sejam estatisticamente significativos. As sequências ponderadas em T2 demonstraram uma correlação positiva moderada e fraca, sendo a ponderação densidade protónica a única a apresentar uma associação negativa. Desta forma, o fantoma revelou-se um ótimo substituto do cérebro humano. Este trabalho culminou na criação de um modelo cerebral tridimensional onde foram individualizadas as regiões das substâncias branca e cinzenta, de forma a posteriormente serem preenchidas pelas correspondentes substâncias desenvolvidas, obtendo-se um fantoma cerebral antropomórfico.
Resumo:
Three PEGylated derivatives of 1,4,7,10-tetraazacyclododecane-1-((6-amino)hexanoic)-4,7,10-triacetic acid) (DOTA-AHA) with different molecular weights were prepared and characterized. Their Gd(III) chelates were studied in aqueous solution using variable-temperature 1H nuclear magnetic relaxation dispersion (NMRD) and 17ONMR spectroscopy in view of the determination of their relaxivity and the parameters that govern it. The relaxivity varied from 5.1 to 6.5 mM-1.s-1 (37 ºC and 60 MHz) with the increasing molecular weight of the PEG chain, being slightly higher than that of the parent chelate Gd(DOTA-AHA), due to a small contribution of a slow global rotation of the complexes. A variable temperature 1H NMR study of several Ln(III) chelates of DOTA-A(PEG750)HA allowed the determination of the isomeric M/m ratio (M = square antiprismatic isomer and m = twisted square antiprismatic isomer, the latter presenting a much faster water exchange) which for the Gd(III) chelate was estimated in circa 1:0.2, very close to that of [Gd(DOTA)]-. This explains why the PEGylated Gd(III) chelate has a water rate exchange similar to that of [Gd(DOTA)]-. The predominance of the M isomer is a consequence of the bulky PEG moiety which does not favor the stabilization of the m isomer in sterically crowded systems at the substituent site, contrary to what happens with less packed asymmetrical DOTA-type chelates with substitution in one of the four acetate C(α) atoms.