970 resultados para Fracture internal fixation


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Relata-se um caso de fratura de tíbia em uma bezerra de sete meses de idade, 200kg de peso, apresentando fratura fechada, cominutiva em diáfise. A fixação externa foi preferida como método de imobilização óssea, utilizando-se pinos transcorticais e gesso sintético. Obteve-se eficiente imobilização da fratura, com rápida recuperação do animal, dispendendo-se pouco tempo para o pós-operatório (52 dias). A técnica demonstrou ser de fácil realização e passível de ser executada a campo.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to comparatively evaluate the mechanical strength of squared and rectangular 2.0 mm system miniplates comparing them to the standard configuration with 2 straight miniplates in stabilizing fractures in the anterior mandible. Ninety synthetic polyurethane mandible replicas were used in mechanical test. The samples were divided into six groups of three different methods for fixation. Groups 1, 2 and 3 showed complete fractures in symphysis, characterized by a linear separation between the medial incisor, and groups 4, 5 and 6 showed complete fractures in parasymphysis with oblique design. Groups 1 and 4 were represented by the standard technique with two straight miniplates parallel to each other. Groups 2 and 5 were stabilized by squared miniplates and groups 3 and 6 were fixed by rectangular design. Each group was subjected to a mechanical test at a displacement speed of 10 mm/min on a universal testing machine, receiving linear vertical load on the region of the left first molar. The values of the maximum load and when displacements reached 5 mm were obtained and statistically analyzed by calculating the confidence interval of 95%. Fixation systems using squared (G2) and rectangular (G3) miniplates obtained similar results. No statistically significant differences with respect to the maximum load and the load at 5 mm displacement were found when compared to standard method in symphyseal fractures (G1). In parasymphysis the fixation method using squared miniplates (G5) obtained results without significant differences regarding the maximum load and the load at 5 mm when compared to the standard configuration (G4). The fixation method using rectangular miniplates (G6) showed inferior results which were statistically significant when compared to the standard configuration (G4) for parasymphysis fractures. The mechanical behavior of the fixation methods was similar, except when rectangular miniplates were used. The fixation methods showed better results with statistical significance in symphyseal fractures

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A luxação traumática isolada da articulação tibiofibular proximal é rara. Esta lesão pode não ser reconhecida ou diagnosticada no atendimento inicial. A ausência de suspeita clínica pode causar problemas para o diagnóstico. O diagnóstico necessita de história precisa do mecanismo e sintomas da lesão, avaliação clínica e radiográfica adequada de ambos joelhos. Casos não reconhecidos são fonte de alterações crônicas. O tratamento é feito por redução fechada e imobilização ou, em casos irredutíveis ou instáveis, redução aberta com fixação interna temporária. Um caso raro de luxação tibiofibular proximal isolada em um jogador de basquetebol é relatado para ilustrar essa lesão.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study verified the resistance to displacement of six miniplate fixation methods after sagittal split osteotomy (SSO). SSO was performed in 30 polyurethane synthetic mandible replicas. The distal segments were advanced (4 mm) and specimens were grouped according to the fixation method: four-hole standard miniplate; four-hole locking miniplate; six-hole standard miniplate; six-hole locking miniplate; six-hole standard sagittal miniplate; six-hole locking sagittal miniplate. Biomechanical evaluation was performed by applying compression loads to three points on the second molar region, using an Instron universal testing machine until a 3 mm displacement of the segments occurred. Compression loads able to produce 3 mm displacement were recorded in kN and subjected to analysis of variance (P < 0.01) and Tukey's tests for comparison between groups (P < 0.05). The locking sagittal miniplate showed higher resistance to displacement than the regular four- and six-hole locking and standard miniplates. No significant differences were observed between the locking sagittal miniplate and the regular sagittal or the four-hole locking miniplates. Two of the three groups with the best results had locking plate fixation methods. Fixation of SSO with a single miniplate is better accomplished using six-hole locking sagittal miniplates, six-hole standard sagittal miniplates, or four-hole locking miniplates; these methods are more resistant to displacement.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: avaliar a estabilidade de cirurgias bimaxilares com fixação interna rígida, na qual promoveu-se uma rotação anti-horária da mandíbula e conseqüente redução do ângulo do plano oclusal. METODOLOGIA: foram estudados 15 pacientes com padrão facial de Classe II e deficiência mandibular. Os movimentos cirúrgicos foram avaliados por meio de medidas lineares e angulares realizadas no programa CefX, obtidas de telerradiografias cefalométricas em norma lateral em três diferentes tempos: (T0) pré-operatório, (T1) pós-operatório imediato e (T2) pós-operatório de no mínimo 6 meses. RESULTADOS E CONCLUSÕES: os resultados demonstraram que a cirurgia bimaxilar promove mudanças faciais significativas e, principalmente, que a rotação anti-horária da mandíbula com redução do ângulo do plano oclusal mostrou-se estatisticamente estável, sendo uma opção confiável em cirurgias de pacientes com padrão facial de Classe II com deficiência mandibular.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of the present study was to analyze the etiology, type and treatment employed in the orbito-zygomatic fractures (OZ). Also, postoperative complications are described and correlated with the type of treatment used. Fifty patients with OZ fractures were evaluated. Orbital fractures in which the zygomatic bone was not involved were excluded. Epidemiologic data and characteristics of treatment such as the type of material used for osteosynthesis, number of anatomical sites on which rigid internal fixation (RIF) was applied, surgical approaches and associated complications were recorded. The main causes of trauma were motorcycle and bicycle accidents, constituting 52% of the sample. The osteosynthesis system used was the 2.0 mm, except in four patients in whom the 1.5mm system was used for fixation at the infra-orbital rim. A total of 18% of the patients required reconstruction of the internal orbit and in all cases titanium mesh was used. 46% of the patients received RIF in three anatomical sites, most in the fronto-zygomatic suture, infra-orbital rim and zygomatic-maxillary buttress. The most frequent complication was paresthesia of the infra-orbital nerve (34 patients, 68%). Other findings were also discussed with the intent of better understanding the treatment of the OZ fractures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: Trying to provide more anatomical data to the oral and maxillofacial surgeons regarding to orthognathic surgery, specifically about sagittal split osteotomy, the authors accomplished an anatomical study in dry human jaws, measuring the thickness in four previously established points of the body and mandibular ramus, at the usual spots used for the internal fixation by screws. Material and Methods: The authors also use the data collected to evaluate if there are significant differences between the group I (human dry mandibles with teeth) and group II (edentulous human dry mandibles). Results: For the group I the authors found the following results: x1 = 14,48, x2 = 14,94, x3=12,82 and x4 = 9,41, being the x2 the thickest point, and the least thick the x4. However in the group II, the found medium values were: x1 = 13,38, x2 = 13,08, x3 = 11,63 and x4 = 12,18, being the thickest point in that group the x1 and the least thick x3. The coefficient of simple correlation between the variables (group I and II) revealed a value of 0,6194, being this difference no significant at the meaning level of 95%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The zygomaticomaxillary complex (ZMC) is the second highly incidental of facial fractures. According to the anatomical complexity, there are many reports in the literature about this trauma, mainly related to treatment for these fractures. With the purpose of evaluating clinically and radiographically the stability of unilateral zygomatic fractures treated by surgical reduction and fixed in two points by stable internal fixation, this research was proposed. Twenty patients with zygomatic fractures were evaluated and compared with twenty nonfractured patients. The results showed that there were no statistically significant differences among the obtained data, perimeter and area, of the treated and contra-lateral sides of the experimental group. When compared to the control group the differences were not statistically significant. We also performed a comparison of the distance between the nasal bone and zygomatic prominence in all groups the results were also satisfactory.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To evaluate the ratio of soft tissue to hard tissue in bilateral sagittal split setback osteotomy with rigid internal fixation or wire fixation. MATERIALS AND METHODS: A literature search was performed using PubMed, Medline, CINAHL, Web of Science, the Cochrane Library, and Google Scholar Beta. From the original 766 articles identified, 8 articles were included. Two articles were prospective and 6 retrospective. The follow-up period ranged from 1 year to 12.7 years for rigid internal fixation. Two articles on wire fixation were found to be appropriate for inclusion. RESULTS: The differences between short- and long-term ratios of the lower lip to lower incisors for bilateral sagittal split setback osteotomy with rigid internal fixation or wire fixation were quite small. The ratio was 1:1 in the long term and by trend slightly lower in the short term. No distinction was seen between the short- and long-term ratios for mentolabial fold. The ratio was found to be 1:1 for the mentolabial fold to point B. In the short term, the ratio of the soft tissue pogonion to the pogonion showed a 1:1 ratio, with a trend to be lower in the long term. The upper lip showed mainly protrusion, but the amount was highly variable. CONCLUSIONS: This systematic review shows that evidence-based conclusions on soft tissue changes are difficult to draw. This is mostly because of inherent problems of retrospective studies, inferior study designs, and the lack of standardized outcome measurements. Well-designed prospective studies with sufficient samples and excluding additional surgery, ie, genioplasty or maxillary surgery, are needed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: The purpose of the present systematic review was to evaluate the soft tissue/hard tissue ratio in bilateral sagittal split advancement osteotomy (BSSO) with rigid internal fixation (RIF) or wire fixation (WF). MATERIALS AND METHODS: The databases PubMed, Medline, CINAHL, Web of Science, Cochrane Library, and Google Scholar Beta were searched. From the original 711 articles identified, 12 were finally included. Only 3 studies were prospective and 9 were retrospective. The postoperative follow-up ranged from 3 months to 12.7 years for RIF and 6 months to 5 years for WF. RESULTS: The short- and long-term ratios for the lower lip to lower incisor for BSSO with RIF or WF were 50%. No difference between the short- and long-term ratios for the mentolabial-fold to point B and soft tissue pogonion to pogonion could be observed. It was a 1:1 ratio. One exception was seen for the long-term results of the soft tissue pogonion to pogonion in BSSO with RIF; they tended to be greater than a 1:1 ratio. The upper lip mainly showed retrusion but with high variability. CONCLUSIONS: Despite a large number of studies on the short- and long-term effects of mandibular advancement by BSSO, the results of the present systematic review have shown that evidence-based conclusions on soft tissue changes are still unknown. This is mostly because of the inherent problems of retrospective studies, inferior study designs, and the lack of standardized outcome measures. Well-designed prospective studies with sufficient sample sizes that have excluded patients undergoing additional surgery (ie, genioplasty or maxillary surgery) are needed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nonunions of pediatric subtrochanteric femur fractures are exceedingly rare and have to date not been reported in the literature. We present the case of an 11-year-old boy who developed such a nonunion after open reduction internal fixation using a pediatric locked proximal femur plate. Using an adult proximal humerus locking plate, adequate proximal fixation of the nonunion was obtained. Furthermore, previously placed distal screw holes were safely bridged and the biomechanical environment around the nonunion site improved. Uneventful healing was possible with the use of adjuvant bone grafting. No short- or midterm complications occurred. Although other implants can certainly be adapted to a use different than that of its original design, the present case suggests that adult proximal humerus locking plates may be a safe option for revision surgery of the proximal pediatric femur.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aims of the study were (1) to determine the cumulative two to twenty-year survivorship of the hip after open reduction and internal fixation of displaced acetabular fractures, (2) to identify factors predicting conversion to total hip arthroplasty or hip arthrodesis, and (3) to create a predictive model that calculates an individual's probability of early need for total hip arthroplasty or hip arthrodesis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To evaluate selective and superselective catheter therapy of serious arterial damage associated with orthopedic surgery of the pelvis, hip joint, femur, and knee. MATERIALS AND METHODS: Between 1989 and 2005, 16 consecutive patients with arterial damage after orthopedic surgery (seven women, nine men; mean age, 62 years; age range, 21-82 y) underwent angiographic exploration. Seven patients were in hemodynamically unstable condition. Initial orthopedic procedures were iliac crest internal fixation (n = 1); total hip prosthesis (n = 3); revision of total hip prosthesis (n = 4); revision of acetabular cup prosthesis (n = 1); gamma-nailing, nail-plate fixation, or intramedullary nailing (n = 3); and total knee prosthesis (n = 4). RESULTS: Angiography showed pseudoaneurysms (n = 11), vascular lacerations with active extravasation (n = 3), and arteriovenous fistulas with extravasation (n = 2). After angiographic documentation of serious arterial injury, 14 patients were treated with a single or coaxial catheter technique in combination with coils alone, coils and polyvinyl alcohol particles, coils and Gelfoam pledgets, or Gelfoam pledgets; or balloon occlusion with isobutyl cyanoacrylate and coils. Two patients were treated with covered stents. In all, bleeding was effectively controlled in a single session in 16 patients, with immediate circulatory stabilization. Major complications included death, pulmonary embolism, and postprocedural hematoma. CONCLUSION: Selective and superselective catheter therapy may be used for effective, minimally invasive management of rare but potentially life-threatening vascular complications after orthopedic surgery.