962 resultados para FALLOPIAN TUBE
Resumo:
PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.
Resumo:
M.C. Addor is included in the Eurocat Working Group
Resumo:
Early detection of neural-tude defects is possible by determining Alpha-fetoprotein (AFP) in maternal serum. 16'685 pregnant women were observed. Three methods for the determination of the "normal" range are compared. The first one, already used in similar studies, makes use of a constant multiple of the median. The other two ones make use of robust estimates of location and scale. Their comparison shows the interest of the robust methods to reduce the interlaboratory variability.
Resumo:
OBJECTIVE: To 'map' the current (2004) state of prenatal screening in Europe. DESIGN: (i) Survey of country policies and (ii) analysis of data from EUROCAT (European Surveillance of Congenital Anomalies) population-based congenital anomaly registers. SETTING: Europe. POPULATION: Survey of prenatal screening policies in 18 countries and 1.13 million births in 12 countries in 2002-04. METHODS: (i) Questionnaire on national screening policies and termination of pregnancy for fetal anomaly (TOPFA) laws in 2004. (ii) Analysis of data on prenatal detection and termination for Down's syndrome and neural tube defects (NTDs) using the EUROCAT database. MAIN OUTCOME MEASURES: Existence of national prenatal screening policies, legal gestation limit for TOPFA, prenatal detection and termination rates for Down's syndrome and NTD. RESULTS: Ten of the 18 countries had a national country-wide policy for Down's syndrome screening and 14/18 for structural anomaly scanning. Sixty-eight percent of Down's syndrome cases (range 0-95%) were detected prenatally, of which 88% resulted in termination of pregnancy. Eighty-eight percent (range 25-94%) of cases of NTD were prenatally detected, of which 88% resulted in termination. Countries with a first-trimester screening policy had the highest proportion of prenatally diagnosed Down's syndrome cases. Countries with no official national Down's syndrome screening or structural anomaly scan policy had the lowest proportion of prenatally diagnosed Down's syndrome and NTD cases. Six of the 18 countries had a legal gestational age limit for TOPFA, and in two countries, termination of pregnancy was illegal at any gestation. CONCLUSIONS: There are large differences in screening policies between countries in Europe. These, as well as organisational and cultural factors, are associated with wide country variation in prenatal detection rates for Down's syndrome and NTD.
Resumo:
Diplomityön tavoitteena oli selvittää, kuinka kohdeyrityksessä nykyhetkellä pitkältiräätälöitynä tuotetut putkilämmönvaihtimet voitaisiin standardisoida, jotta pystyttäisiin kohdistamaan resursseja oikein ja parantamaan siten yrityksen taloudellista suorituskykyä. Tutkimuksen edetessä määräävimmäksi tekijäksi työn tuloksia ajatellen nousi taloudellinen standardisointiaste, jonka perusteeksi kohdeyrityksen putkilämmönvaihtimissa valittiin standardisoitu suunnitteluohjeisto. Suunnitteluohjeiston lisäksi tuotestandardiin liitettiin ehdotus toimintapojen automatisoimisesta parametrisen valintataulukon sekä sähköisen manuaalin avulla. Työssä tuotestandardisointia tarkastellaan rationalisointi-investointina ja sen kannattavuutta on tarkasteltu investointilaskelmien sekä herkkyys analyysin avulla. Alkuarvot investointilaskelmissa perustuvat työssä yhdelle putkilämmönvaihtimelletoteutettuun tuotestandardisointitapaan, jos tätä tapaa käytettäisiin jatkossa kaikkiin kyseisen yksikön putkilämmönvaihtimiin.
Resumo:
Several possible methods of increasing the efficiency and power of hydro power plants by improving the flow passages are investigated in this stydy. The theoretical background of diffuser design and its application to the optimisation of hydraulic turbine draft tubes is presented in the first part of this study. Several draft tube modernisation projects that have been carried out recently are discussed. Also, a method of increasing the efficiency of the draft tube by injecting a high velocity jet into the boundary layer is presented. Methods of increasing the head of a hydro power plant by using an ejector or a jet pump are discussed in the second part of this work. The theoretical principles of various ejector and jet pump types are presented and four different methods of calculating them are examined in more detail. A self-made computer code is used to calculate the gain in the head for two example power plants. Suitable ejector installations for the example plants are also discussed. The efficiency of the ejector power was found to be in the range 6 - 15 % for conventional head increasers, and 30 % for the jet pump at its optimum operating point. In practice, it is impossible to install an optimised jet pump with a 30 % efficiency into the draft tube as this would considerabely reduce the efficiency of the draft tube at normal operating conditions. This demonstrates, however, the potential for improvement which lies in conventional head increaser technology. This study is based on previous publications and on published test results. No actual laboratory measurements were made for this study. Certain aspects of modelling the flow in the draft tube using computational fluid dynamics are discussed in the final part of this work. The draft tube inlet velocity field is a vital boundary condition for such a calculation. Several previously measured velocity fields that have successfully been utilised in such flow calculations are presented herein.
Resumo:
STUDY QUESTION: What are the long term trends in the total (live births, fetal deaths, and terminations of pregnancy for fetal anomaly) and live birth prevalence of neural tube defects (NTD) in Europe, where many countries have issued recommendations for folic acid supplementation but a policy for mandatory folic acid fortification of food does not exist? METHODS: This was a population based, observational study using data on 11 353 cases of NTD not associated with chromosomal anomalies, including 4162 cases of anencephaly and 5776 cases of spina bifida from 28 EUROCAT (European Surveillance of Congenital Anomalies) registries covering approximately 12.5 million births in 19 countries between 1991 and 2011. The main outcome measures were total and live birth prevalence of NTD, as well as anencephaly and spina bifida, with time trends analysed using random effects Poisson regression models to account for heterogeneities across registries and splines to model non-linear time trends. SUMMARY ANSWER AND LIMITATIONS: Overall, the pooled total prevalence of NTD during the study period was 9.1 per 10 000 births. Prevalence of NTD fluctuated slightly but without an obvious downward trend, with the final estimate of the pooled total prevalence of NTD in 2011 similar to that in 1991. Estimates from Poisson models that took registry heterogeneities into account showed an annual increase of 4% (prevalence ratio 1.04, 95% confidence interval 1.01 to 1.07) in 1995-99 and a decrease of 3% per year in 1999-2003 (0.97, 0.95 to 0.99), with stable rates thereafter. The trend patterns for anencephaly and spina bifida were similar, but neither anomaly decreased substantially over time. The live birth prevalence of NTD generally decreased, especially for anencephaly. Registration problems or other data artefacts cannot be excluded as a partial explanation of the observed trends (or lack thereof) in the prevalence of NTD. WHAT THIS STUDY ADDS: In the absence of mandatory fortification, the prevalence of NTD has not decreased in Europe despite longstanding recommendations aimed at promoting peri-conceptional folic acid supplementation and existence of voluntary folic acid fortification. FUNDING, COMPETING INTERESTS, DATA SHARING: The study was funded by the European Public Health Commission, EUROCAT Joint Action 2011-2013. HD and ML received support from the European Commission DG Sanco during the conduct of this study. No additional data available.
Resumo:
Objective: To analyze standardized uptake values (SUVs) using three different tube current intensities for attenuation correction on 18FNaF PET/CT scans. Materials and Methods: A total of 254 18F-NaF PET/CT studies were analyzed using 10, 20 and 30 mAs. The SUVs were calculated in volumes of interest (VOIs) drawn on three skeletal regions, namely, right proximal humeral diaphysis (RH), right proximal femoral diaphysis (RF), and first lumbar vertebra (LV1) in a total of 712 VOIs. The analyses covered 675 regions classified as normal (236 RH, 232 RF, and 207 LV1). Results: Mean SUV for each skeletal region was 3.8, 5.4 and 14.4 for RH, RF, and LV1, respectively. As the studies were grouped according to mAs value, the mean SUV values were 3.8, 3.9 and 3.7 for 10, 20 and 30 mAs, respectively, in the RH region; 5.4, 5.5 and 5.4 for 10, 20 and 30 mAs, respectively, in the RF region; 13.8, 14.9 and 14.5 for 10, 20 and 30 mAs, respectively, in the LV1 region. Conclusion: The three tube current values yielded similar results for SUV calculation.