817 resultados para FACILE ACCESS
Resumo:
We have designed, built, and tested an early prototype of a novel subxiphoid access system intended to facilitate epicardial electrophysiology, but with possible applications elsewhere in the body. The present version of the system consists of a commercially available insertion needle, a miniature pressure sensor and interconnect tubing, read-out electronics to monitor the pressures measured during the access procedure, and a host computer with user-interface software. The nominal resolution of the system is <0.1 mmHg, and it has deviations from linearity of <1%. During a pilot series of human clinical studies with this system, as well as in an auxiliary study done with an independent method, we observed that the pericardial space contained pressure-frequency components related to both the heart rate and respiratory rate, while the thorax contained components related only to the respiratory rate, a previously unobserved finding that could facilitate access to the pericardial space. We present and discuss the design principles, details of construction, and performance characteristics of this system.
Resumo:
Catheter migration or catheter fracture and consequent migration of a fragment is a rare complication that occurs in 1% of the patients. Despite the low incidence, embolization may cause severe and potentially fatal complications, with the mortality rates varying between 24 and 60%. The gold standard treatment for this condition is the extraction of the fragmented catheter by the intravascular percutaneous route, through the common femoral vein. If it is not available, the extraction procedure must be performed through an alternative access. This article describes a fully successful removal of a fragmented catheter by percutaneous intravascular access obtained through the right subclavian vein.
Resumo:
Objective: The study compared the prevalence, correlates of functional impairment, and service utilization for eating disorders across Latinos, Asians, and African Americans living in the United States to non-Latino Whites. Method: Pooled data from the NIMH Collaborative Psychiatric Epidemiological Studies (CPES; NIMH, 2007) were used. Results: The prevalence of anorexia nervosa (AN) and binge-eating disorder (BED) were similar across all groups examined, but bulimia nervosa (BN) was more prevalent among Latinos and African Americans than non-Latino Whites. Despite similar prevalence of BED among ethnic groups examined, lifetime prevalence of any binge eating (ABE) was greater among each of the ethnic minority groups in comparison to non-Latino Whites. Lifetime prevalence of mental health service utilization was lower among ethnic minority groups studied than for non-Latino Whites for respondents with a lifetime history of any eating disorder. Discussion: These findings suggest the need for clinician training and health policy interventions to achieve optimal and equitable care for eating disorders across all ethnic groups in the United States. (C) 2010 by Wiley Periodicals, Inc.
Resumo:
BACKGROUND: The most common laparoscopic complications are associated with trocar insertion. The purpose of this study was to develop an objective method of evaluating the safety profile of various access devices used in laparoscopic surgery. STUDY DESIGN: In 20 swine, 6 bladed and 2 needle access devices were evaluated. A force profile was determined by measuring the force required to drive the trocar or needle through the fascia and into the peritoneum, at 0 and 10 mmHg. The amount Of tissue deformation, the length of blade exposed, and the duration of exposure were measured using a high-speed digital imaging system. RESULTS: The needle system without the sheath required the least driving force and had the most favorable force profile. In contrast, the bladed, nonretractable trocar system required a higher driving force and a rapid loss of resistance. Insertion under a pneumoperitoneum did not significantly alter the force profile of the various access devices except for the amount of tissue deformation. With the bladed system, the blade itself was exposed for an average of 0.5 to 1.0 seconds for a distance of 4.5 to 5.0 cm. In comparison, the needle system was exposed for 0.2 seconds for a distance of 1.8 cm. CONCLUSIONS: We developed a reproducible method of measuring the forces required to place the access systems, their pattern of resistance loss, and the characteristics of the blade exposure. These parameters may provide an adjunctive and objective measurement of safety, allowing for more direct comparison between various trocar designs. (J Am Coll Surg 2009;209:222-232. (C) 2009 by the American College of Surgeons)
Resumo:
SETTING: Itaborai Municipality in Rio de Janeiro, Brazil. OBJECTIVE: To evaluate access to tuberculosis (TB) diagnosis for users of the Family Health Program (FHP) and Reference Ambulatory Units (RAUs). DESIGN : A cross-sectional study was conducted in Itaborai City, Rio de Janeiro, Brazil. Between July and October 2007, a sample of 100 TB patients registered consecutively with the TB Control Program was interviewed using the primary care assessment tool. The two highest scores, describing `almost always` and `always`, or `good` and `very good`, were used as a cut-off point to define high quality access to diagnosis. RESULTS: FHP patients were older and had less education than RAU interviewees. Sex and overcrowding did not differ in the two groups. Patient groups did not differ with regard to the number of times care was sought at a unit, transport problems, cost of attending units and availability of consultation within 24 h. Adequate access to diagnosis was identified by 62% of the FHP patients and 53% of the RAU patients (P = 0.01). CONCLUSION: In Itaborai, Rio de Janeiro, TB patients believe that the FHP units provide greater access to TB diagnosis than RAUs. These findings will be used by the Department of Health to improve access to diagnosis in Itaborai.
Resumo:
Background-Puncture of the atrial appendage may provide access to the pericardial space. The aim of this study was to evaluate the feasibility of epicardial mapping and ablation through an endocardial transatrial access in a swine model. Methods and Results-An 8-F Mullins sheath was used to perforate the right (n=16) or left (n=1) atrial appendage in 17 pigs (median weight, 27.5 kg; first and third quartiles [Q1, Q3], 25.2, 30.0 kg). A 7-F ablation catheter was introduced into the pericardial space to perform epicardial mapping and deliver radiofrequency pulses on the atria. The pericardial space was entered in all 17 animals. In 15 (88%) animals, there was no hemodynamic instability (mean blood pressure monitoring, initial median, 80 mm Hg; Q1, Q3, 70, 86 mm Hg; final median, 88 mm Hg; Q1, Q3, 80, 96 mm Hg; P=0.426). In these 15, a mild hemorrhagic pericardial effusion was identified and aspirated (median, 20 mL; Q1, Q3, 15, 30 mL) during the procedure, and postmortem gross analysis revealed that the atrial perforation was closed in these animals. In 2 (12%) of the 17 animals, there was major pericardial bleeding with hemodynamic collapse. On gross examination, it was found that pericardial space was accessed through right ventricular perforation in 1 animal and the tricuspid annulus in the other. After the initial study, we used an occlusion device in 3 other animals to attempt to seal the puncture (2 at the right atrial appendage and 1 at the right ventricle). These 3 animals had no significant pericardial bleeding. Conclusions-Transatrial endovascular right atrial appendage puncture may provide a potential alternative route for pericardial access. Further studies are needed to evaluate its safety with longer and more-complex procedures before being applied in clinical settings. (Circ Arrhythm Electrophysiol. 2011;4:331-336.)