937 resultados para Extremidades inferiores


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents the development of a prototype of an intelligent active orthosis for lower limbs whit an electronic embedded system. The proposed orthosis is an orthopedical device with the main objective of providing walking capacity to people with partial or total loss of lower limbs movements. In order to design the kinematics, dynamics and the mechanical characteristics of the prototype, the biomechanics of the human body was analized. The orthosis was projected to reproduce some of the movements of the human gait as walking in straight forward, sit down, get up, arise and go down steps. The joints of the orthosis are controlled by DC motors equipped with mechanical reductions, whose purpose is to reduce rotational speed and increase the torque, thus generating smooth movements. The electronic embedded system is composed of two motor controller boards with two channels that communicate with a embedded PC, position sensors and limit switches. The gait movements of the orthosis will be controlled by high level commands from a human-machine interface. The embedded electronic system interprets the high level commands, generates the angular references for the joints of the orthosis, controls and drives the actuators in order to execute the desired movements of the user

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The manufacture of prostheses for lower limb amputees (transfemural and transtibial) requires the preparation of a cartridge with appropriate and custom fit to the profile of each patient. The traditional process to the patients, mainly in public hospitals in Brazil, begins with the completion of a form where types of equipment, plugins, measures, levels of amputation etc. are identified. Currently, such work is carried out manually using a common metric tape and caliper of wood to take the measures of the stump, featuring a very rudimentary, and with a high degree of uncertainty geometry of the final product. To address this problem, it was necessary to act in two simultaneously and correlated directions. Originally, it was developed an integrated tool for viewing 3D CAD for transfemoral types of prostheses and transtibial called OrtoCAD I. At the same time, it was necessary to design and build a reader Mechanical equipment (sort of three-dimensional scanner simplified) able to obtain, automatically and with accuracy, the geometric information of either of the stump or the healthy leg. The methodology includes the application of concepts of reverse engineering to computationally generate the representation of the stump and/or the reverse image of the healthy member. The materials used in the manufacturing of prostheses nor always obey to a technical scientific criteria, because, if by one way it meets the criteria of resistance, by the other, it brings serious problems mainly due to excess of weight. This causes to the user various disorders due to lack of conformity. That problem was addressed with the creation of a hybrid composite material for the manufacture of cartridges of prostheses. Using the Reader Fitter and OrtoCAD, the new composite material, which aggregates the mechanical properties of strength and rigidity on important parameters such as low weight and low cost, it can be defined in its better way. Besides, it brings a reduction of up steps in the current processes of manufacturing or even the feasibility of using new processes, in the industries, in order to obtain the prostheses. In this sense, the hybridization of the composite with the combination of natural and synthetic fibers can be a viable solution to the challenges offered above

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We built an experimental house on an UFRN´s land using blocks made by a composite consisting of cement, plaster, EPS, crushed rubber and sand. Several blocks were made from various compositions and we made preliminary tests of mechanical and thermal resistance, choosing the most appropriate proportion. PET bottles were used inside the block to provide thermal resistance. In this work, a second function was given to the bottles: to serve as a docking between the blocks, because the ends of the cylinders came out of each block on top as well as at the bottom, with the bottom cut, allowing to fit of the extremities of the upper cylinder of a block in the lower holes of the other one, which were formed by the cutting already mentioned. Minimum compression tests were performed according to ABNT standards for walls closing blocks (fence). With that house built, we did studies of thermal performance in order to ascertain conditions of comfort, checking external and internal temperatures in the walls and in the ambient, among other variables, such as wind speed and relative humidity. The resulting blocks provided adequate thermal insulation to the environment, where the walls presented differences up to 11.7 ºC between the outer and inner faces, getting the maximum temperature inside the house around 31 °C, within the so-called thermal comfort zone for warm climates. At the end of the experiments it was evident the effectiveness of that construction in order to provide thermal comfort in the internal environment of the house, as well as we could confirm the viability of building houses from recyclable materials, reducing the constructive costs, becoming a suitable alternative for low- incoming families. Moreover, besides the low cost, the proposal represents an alternative use of various recyclable materials, therefore considered an ecological solution

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic venous disease (CVD) is evident among the chronic diseases and affects the elderly population and primarily is responsible for leg ulcers in this population. The use of dressings in the care of a venous ulcer is a fundamental part of the treatment for healing, however, evidence to assist in choosing the best dressing is scarce. The main objective of this study was to evaluate the effectiveness of treatment with hydrogel in the healing of venous ulcers using search methods, synthesis of information and statistical research through a systematic review and meta-analysis. Randomized controlled trials were selected in the following databases: CENTRAL; DARE; NHS EED; MEDLINE; EMBASE; CINAHL. Beyond these databases three websites were consulted to identify ongoing studies: ClinicalTrials.gov, OMS ICTRP e ISRCTN. The primary outcomes were analyzed: complete wound healing, incidence of wound infection and the secondary were: changes in ulcer size, time to ulcer healing, recurrence of ulcer, quality of life of participants, pain and costs of treatment. Four studies are currently included in the review with a total of 250 participants. The use of hydrogel appears to be superior to conventional dressing, gauze soaked in saline, for the healing of venous leg ulcers; 16/30 patients showed complete healing of ulcers (RR 5,33, 95%CI [1,73,16,42]). The alginate gel was shown to be more effective when compared to the hydrogel dressing in reduction of the wound area; 61,2% (± 26,2%) with alginate e 19,4% (± 24,3%) with hydrogel at the end of four weeks of treatment. Manuka honey has shown to be similar to the hydrogel dressings in percentage of area reduction. This review demonstrated that there is no evidence available about the effectiveness of the hydrogel compared to other types of dressings on the healing of venous leg ulcers of the lower limbs, thus demonstrating the need of future studies to assist health professionals in choosing the correct dressing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The neurovascular system of the pulp and of the periodontium is interconnected and among the possible intercommunications between these two tissues, there is the cavo inter-radicular canal. It is a small canal that goes through any inter-radicular dentine and arises in the furca region of the multi-radicular teeth. Its predominance has been studied in the literature, by several methodologies, with divergent results. The objective of this work was to establish, in vitro, the predominance of the cavo inter-radicular canal, in human lower molars, through the diaphanization technique and dye leakage. For this research, 140 teeth (100 first and second 40 lower molars) were selected, extracted due to different reasons, belonging to a teeth bank of the Endodontics discipline of the Dentistry College at Federal University of Rio Grande do Norte. The teeth were preserved in formol until the moment of use and immersed in physiological solution. Had the endodontic access fulfilled and the whole external surface, except for the furcation, sealed with two layers of nail enamel. The cleaning of the pulpar chamber floor was carried out with sodium hypochlorite solution 5%, being this solution renewed every 5 minutes, during 1 hour. The teeth were immersed in Indian dye and, after drying of the dye, they had their crowns split up in the amelo-cemental junction. Then, they were examined in a stereomicroscope, where marks of the coloring were observed in the furcation and on the pulpar floor. After this recording, the sample was diaphanized and with the transparent teeth, it was possible to observe in the stereomicroscope, the true inter-radicular canals. As a result of this experiment, the presence of these canals was observed in 13 % of the first and 7, 5 % of the second evaluated molars. The study showed that both the presence of the cavo inter-radicular canal is real and the diaphanization and dye leakage is an efficient method for this type of research

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The literature has shown a relation between periodontics and the removable partial denture (RPD), with progressive destruction observed in the support structures. The aim of this study was to clinically assess periodontal condition in users of removal partial denture (RPD), and compare right abutments teeth, indirect abutments and controls before installation and after 1 year, in addition to comparing tooth-supported and tooth mucosa-supported abutments. A total of 50 patients, 32 women and 18 men, mean age of 45 years, took part in the study. The patients were examined by a single examiner at prosthesis installation and after 3, 6, 9 and 12 months. The following were verified at each examination: Probe Depth (PD), Plaque Index (PI), Gingival Index (GI), the amount of Keratinized Mucosa (KM), Gingival Recession (GR) and Dental Mobility (DM); in addition patients received oral hygiene orientation, accompanied by prophylaxis, periodontal scaling and root planing (PSRP), when necessary. Analysis of Variance (ANOVA) with Tukey-Kramer post test was used to assess the dependent variables (PD, PI, KM, GR) of the three groups over time while Friedman s test was used for GI. To assess the outcomes of prosthesis type in the right abutment group, a confidence interval-based analysis was performed. The results showed that the control group was the least compromised in all the variables studied. With respect to development of the groups over time, it was verified that the measures for GR, PD, GI and KM increased from initial examination to 1 year of use in all the groups, but only PI showed a significant increase. There was a non-discriminatory low prevalence of dental mobility. The tooth mucosa-supported prosthesis had significantly higher values for GR, GI and PI and significantly lower ones for KM when compared to tooth-supported. Over time, both types of prostheses showed no significant differences from initial to final examination for the variables GR, PD, KM and GI, with PI significant only for tooth-supported. The results showed that the teeth most involved in RPD design had greater potential of periodontal damage, probably because of greater dental biofilm accumulation. Abutments elements adjacent to the free extremities had less favorable periodontal condition than those adjacent to interpolated spaces, but the use of RPD did not worsen the initial condition

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O diagnóstico da trombose venosa profunda sintomática está bem estabelecido com o uso do mapeamento dúplex, que apresenta sensibilidade de 100% e especificidade de 98%, para trombose venosa profunda proximal, e sensibilidade de 94% e especificidade de 75%, para distal. Na trombose venosa profunda recente e assintomática, o diagnóstico com o mapeamento dúplex ainda não está bem estabelecido, mostrando uma queda na acurácia desse método diagnóstico. Essa queda é devida ao fato de o trombo recente não ser oclusivo, apresentar a mesma ecogenicidade do sangue e uma consistência diminuída, prejudicando o teste da compressibilidade, que é o mais sensível para diagnóstico da trombose venosa profunda. Nesta revisão, serão revistos artigos publicados que avaliaram a acurácia do mapeamento dúplex no diagnóstico da trombose venosa profunda assintomática.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A avaliação clínica dos membros inferiores na insuficiência venosa por si só não identifica os sistemas envolvidos ou os níveis anatômicos, sendo necessários exames complementares. Esses exames podem ser invasivos ou não-invasivos. Os invasivos, como flebografia e pressão venosa ambulatória, apesar de terem boa acurácia, trazem desconforto e complicações. Dentre os não-invasivos, destacam-se: Doppler ultra-som de ondas contínuas, fotopletismografia, pletismografia a ar e mapeamento dúplex. O Doppler ultra-som avalia a velocidade do fluxo sangüíneo de maneira indireta. A fotopletismografia avalia o tempo de reenchimento venoso, fornecendo um parâmetro objetivo de quantificação do refluxo venoso. A pletismografia a ar permite quantificar a redução ou não da capacitância, o refluxo e o desempenho da bomba muscular da panturrilha. O dúplex é considerado padrão-ouro dentre os não-invasivos, porque permite uma avaliação quantitativa e qualitativa, fornecendo informações anatômicas e funcionais, dando avaliação mais completa e detalhada dos sistemas venosos profundo e superficial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTO: A aplicação de uma estratégia baseada em um modelo clínico associado ao mapeamento dúplex (MD) pode permitir um diagnóstico da trombose venosa profunda (TVP) mais seguro, eficaz e custo-efetivo. OBJETIVO: Testar o modelo clínico de Wells et al. associado ao MD e verificar a ocorrência de TVP nos pacientes categorizados quanto à probabilidade de apresentar a doença, e determinar se, a partir dos resultados obtidos, seria possível reduzir o número de exames seriados com o MD. MÉTODOS: Os pacientes com suspeita clínica de TVP foram categorizados quanto à apresentação de TVP em baixa, moderada e alta probabilidade (BP, MP, AP) e, em seguida, submetidos ao MD. Pacientes com MD negativo repetiram o exame em 24-48 horas e em 7 dias. Pacientes com exame positivo para TVP foram tratados. Todos os pacientes sem TVP foram convocados para reavaliação clínica em 3 meses. RESULTADOS: A ocorrência de TVP entre os 489 pacientes avaliados foi de 39,1% (191), sendo 35,6% identificados no exame inicial e 3,5% no exame seriado. Os índices de pacientes que apresentaram TVP foram de 6,1% no grupo de BP, 26,9% no grupo de MP e 79,5% no grupo de AP. No exame seriado, o percentual de TVP foi de 2,4, 7,8 e 15,1% nos grupos BP, MP e AP, respectivamente. Dos pacientes com MD negativo, 62,4% compareceram após 3 meses, e piora dos sintomas foi apresentada por apenas um paciente. Neste, o MD mostrou TVP de veia poplítea. CONCLUSÃO: Os resultados obtidos sugerem que, para os pacientes com BP para TVP e MD negativo, seria possível prescindir do exame seriado, devido à baixa ocorrência de TVP neste grupo, tornando, assim, a abordagem diagnóstica mais simples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o desempenho da análise de imagem digital na estimativa da área acometida pelas úlceras crônicas dos membros inferiores. MÉTODOS: Estudo prospectivo em que foram mensuradas úlceras empregando o método planimétrico clássico, utilizando desenho dos seus contornos em filme plástico transparente, medida sua área posteriormente por folha milimetrada. Esses valores foram utilizados como padrão para a comparação com a estimativa de área pelas fotografias digitais padronizadas das úlceras e dos desenhos das mesmas em filme plástico. Para criar um referencial de conversão dos pixels em milímetros, foi empregado um adesivo com tamanho conhecido, adjacente à úlcera. RESULTADOS: foram avaliadas 42 lesões em 20 pacientes portadores de úlceras crônicas de membros inferiores. As áreas das úlceras variaram de 0,24 a 101,65cm². Observou-se forte correlação entre as medidas planimétricas e as fotos das úlceras (R²=0,86 p<0,01), porém a correlação das medidas planimétricas com as fotos digitais dos desenhos das úlceras foi ainda maior (R²=0,99 p<0,01). CONCLUSÃO: A fotografia digital padronizada revelou-se método rápido, preciso e não-invasivo capaz de estimar a área afetada por úlceras. A avaliação das medidas fotográficas dos contornos das úlceras deve ser preferida em relação à análise de sua fotografia direta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVOS: comparar os valores médios normais das angulações mesiodistais dentárias, propostos por Ursi, em 1989, com as angulações mesiodistais de caninos, pré-molares e molares inferiores em indivíduos com e sem a presença dos terceiros molares inferiores e idades entre 18 e 25 anos. Além disso, foram comparados os valores das angulações mesiodistais desses dentes nessas duas situações. MÉTODOS: foram utilizadas 40 radiografias ortopantomográficas de indivíduos, de ambos os gêneros, que não receberam tratamento ortodôntico, divididos em dois grupos: Grupo I, constituído por 20 radiografias que não apresentavam os terceiros molares inferiores; e Grupo II, formado por 20 radiografias com os terceiros molares inferiores presentes. RESULTADOS E CONCLUSÕES: a análise dos resultados e a análise estatística permitiram concluir que ambos os grupos exibiram pré-molares e molares inferiores mais angulados em sentido mesial, quando comparados à oclusão normal. Por outro lado, a angulação mesiodistal de caninos inferiores mostrou-se semelhante àquela apresentada em casos de oclusão normal. Os dois grupos, quando comparados entre si, exibiram semelhantes valores angulares dos caninos, pré-molares e molares inferiores, de modo que a presença dos terceiros molares não exerceu influência sobre essas angulações mesiodistais dentárias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: o presente trabalho objetivou avaliar as alterações ocorridas nas posições dos terceiros molares inferiores em pacientes tratados ortodonticamente com extrações dos primeiros pré-molares. METODOLOGIA: utilizou-se 80 ortopantomografias, obtidas no pré e pós-tratamento ortodôntico corretivo de 40 pacientes, divididos em dois grupos. O grupo 1 constou de 20 pacientes (13 femininos e 7 masculinos) que se submeteram a tratamento ortodôntico com extrações de primeiros pré-molares. O grupo 2 foi constituído por 20 pacientes (13 femininos e 7 masculinos) tratados ortodonticamente sem extrações. Foram estabelecidas medidas angulares, com o objetivo de avaliar as inclinações e medidas lineares, para analisar as modificações no sentido vertical dos terceiros molares. Todos os dados foram mensurados duas vezes, cujos valores médios foram submetidos dos testes t emparelhado e teste t independente. RESULTADOS: os resultados mostraram diferenças estatisticamente significantes (p<0,01) entre as medidas angulares finais e iniciais do grupo 1. CONCLUSÕES: concluiu-se que os deslocamentos verticais dos terceiros molares inferiores são semelhantes nos casos tratados ortodonticamente com e sem extrações e que estes elementos dentários tornam-se mais verticalizados ao final da terapia realizada com extrações de primeiros pré-molares inferiores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo foi comparar a magnitude do efeito protetor (EP) contra o dano muscular (DM) induzido por uma sessão de exercícios excêntricos (EEM) entre os extensores do joelho e os flexores do cotovelo. Doze sujeitos do gênero masculino foram divididos em 2 grupos, braços (GB) e pernas (GP), e realizaram 2 sessões de EEM. Foram coletados 3 marcadores de DM, sendo eles, pico de torque isométrico (PTI), creatina quinase (CK) e percepção subjetiva de dor (PSD), antes, imediatamente após (com exceção da CK) e 48 horas após cada sessão de EEM. Foi encontrada queda significante de PTI e aumento significante de CK e PSD tanto imediatamente e 48 horas após a primeira sessão de EEM para o GB. No GP houve aumento significante de CK 48 horas após os EEM e da PSD imediatamente após os EEM, decorrentes da primeira sessão. No GB, a segunda sessão apenas provocou queda de PTI imediatamente após os EEM, enquanto no GP houve aumento significante apenas na PSD imediatamente após a segunda sessão de EEM. Apenas a CK apresentou EP para ambos os grupos. Pudemos concluir que o EP foi maior para o GB em comparação com o GP. Esse fenômeno pode ter ocorrido em detrimento da existência de um EP prévio para o GP, uma vez que este membro realiza contrações excêntricas intensas com maior freqüência no dia-a-dia, quando comparados com os GB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTO: A insuficiência venosa crônica tem um impacto socioeconômico considerável nos países ocidentais devido à alta prevalência, custo das investigações e tratamento e à perda de dias trabalhados. O questionário de qualidade de vida Short Form Health Survey (SF-36), bem como a análise da ativação muscular e mobilidade da articulação tibiotársica, é um instrumento utilizado para a sua mensuração. OBJETIVO: Avaliar as limitações osteomusculares e as alterações na qualidade de vida em portadores de úlcera venosa em membros inferiores. MÉTODOS: Foram estudados dez pacientes com úlceras classificadas com Classificação de Doença Venosa Crônica (CEAP: Clinica, Eliologia, Anatomia e Fisiopatologia) 6, que responderam ao questionário SF36 e à escala analógica de dor e realizaram a goniometria, força muscular e eletromiografia. RESULTADOS: A idade média do grupo estudado foi 67,4 (±11,7), sendo 70% dos casos do sexo feminino. Não houve correlação significativa entre dor amplitude do movimento (ADM), força muscular, eletromiografia (EMG) e o tamanho da lesão. Entretanto, houve correlação entre o perfil psicológico do SF-36 e o domínio de atividades motoras, bem como do perfil psicológico com as atividades sociais e percepção de si mesmo. Também houve diferença significativa na avaliação eletromiográfica dos músculos estudados. CONCLUSÃO: A presença de úlcera venosa em membros inferiores pode gerar limitações e alterações na qualidade de vida destes indivíduos. O aspecto psicossocial demonstrou-se preponderante sobre o aspecto motor, aumentando as restrições nas atividades de vida diária.