968 resultados para Effective lens position


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present effective-mass calculations of the bound-state energy levels of electrons confined inside lens-shaped InxGa1-xAs quantum dots (QDs) embedded in a GaAs matrix, taking into account the strain as well as the In gradient inside the QDs due to the strong In segregation and In-Ga intermixing present in the InxGa1-xAs/GaAs system. In order to perform the calculations, we used a continuum model for the strain, and the QDs and wetting layer were divided into their constituting monolayers, each one with a different In concentration, to be able to produce a specific composition profile. Our results clearly show that the introduction of such effects is very important if one desires to correctly reproduce or predict the optoelectronic properties of these nanostructures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to compare the effects of active and passive lacebacks on antero-posterior position of maxillary first molars and central incisors during leveling phase. Twenty-three subjects with Class I and Class II malocclusion were treated with first premolars extraction using preadjusted appliances (MBT 0.022-inch brackets). The leveling phase was performed with stainless steel archwires only. The sample was divided into 2 groups: 14 subjects received active lacebacks (Group 1) and 9 subjects received passive lacebacks (Group 2). Lacebacks were made from 0.008-inch ligature wire. Lateral cephalometric radiographs were taken pre- and post-leveling phase. Student's t-test was applied to determine the differences between pre- and post-leveling mean values and to determine the mean differences between groups. In Group I, the first molars showed a significant mesial movement, whereas no change was observed in Group 2. In both groups, maxillary central incisor crowns moved to lingual side. In conclusion, active laceback produced anchorage loss of maxillary first molars whereas passive laceback did not affect the position of these teeth. Active and passive lacebacks were effective in preventing central incisor proclination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Communication in cancer care has become a major topic of interest. Since there is evidence that ineffective communication affects both patients and oncology clinicians (physicians and nurses), so-called communication skills trainings (CSTs) have been developed over the last decade. While these trainings have been demonstrated to be effective, there is an important heterogeneity with regard to implementation and with regard to evidence of different aspects of CST. Methods: In order to review and discuss the scientific literature on CST in oncology and to formulate recommendations, the Swiss Cancer League has organised a consensus meeting with European opinion leaders and experts in the field of CST, as well as oncology clinicians, representatives of oncology societies and patient organisations. On the basis of a systematic review and a meta-analysis, recommendations have been developed and agreed upon. Results: Recommendations address (i) the setting, objectives and participants of CST, (ii) its content and pedagogic tools, (iii) organisational aspects, (iv) outcome and (v) future directions and research. Conclusion: This consensus meeting, on the basis of European expert opinions and a systematic review and meta-analysis, defines key elements for the current provision and future development and evaluation of CST in oncology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Computer-based feedback systems for assessing the quality of cardiopulmonary resuscitation (CPR) are widely used these days. Recordings usually involve compression and ventilation dependent variables. Thorax compression depth, sufficient decompression and correct hand position are displayed but interpreted independently of one another. We aimed to generate a parameter, which represents all the combined relevant parameters of compression to provide a rapid assessment of the quality of chest compression-the effective compression ratio (ECR). METHODS: The following parameters were used to determine the ECR: compression depth, correct hand position, correct decompression and the proportion of time used for chest compressions compared to the total time spent on CPR. Based on the ERC guidelines, we calculated that guideline compliant CPR (30:2) has a minimum ECR of 0.79. To calculate the ECR, we expanded the previously described software solution. In order to demonstrate the usefulness of the new ECR-parameter, we first performed a PubMed search for studies that included correct compression and no-flow time, after which we calculated the new parameter, the ECR. RESULTS: The PubMed search revealed 9 trials. Calculated ECR values ranged between 0.03 (for basic life support [BLS] study, two helpers, no feedback) and 0.67 (BLS with feedback from the 6th minute). CONCLUSION: ECR enables rapid, meaningful assessment of CPR and simplifies the comparability of studies as well as the individual performance of trainees. The structure of the software solution allows it to be easily adapted to any manikin, CPR feedback devices and different resuscitation guidelines (e.g. ILCOR, ERC).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Therapy has improved the survival of heart failure (HF) patients. However, many patients progress to advanced chronic HF (ACHF). We propose a practical clinical definition and describe the characteristics of this condition. Patients that are generally recognised as ACHF often exhibit the following characteristics: 1) severe symptoms (NYHA class III to IV); 2) episodes with clinical signs of fluid retention and/or peripheral hypoperfusion; 3) objective evidence of severe cardiac dysfunction, shown by at least one of the following: left ventricular ejection fraction<30%, pseudonormal or restrictive mitral inflow pattern at Doppler-echocardiography; high left and/or right ventricular filling pressures; elevated B-type natriuretic peptides; 4) severe impairment of functional capacity demonstrated by either inability to exercise, a 6-minute walk test distance<300 m or a peak oxygen uptake<12-14 ml/kg/min; 5) history of >1 HF hospitalisation in the past 6 months; 6) presence of all the previous features despite optimal therapy. This definition identifies a group of patients with compromised quality of life, poor prognosis, and a high risk of clinical events. These patients deserve effective therapeutic options and should be potential targets for future clinical research initiatives.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Starting from the early descriptions of Kraepelin and Bleuler, the construct of schizotypy was developed from observations of aberrations in nonpsychotic family members of schizophrenia patients. In contemporary diagnostic manuals, the positive symptoms of schizotypal personality disorder were included in the ultra high-risk (UHR) criteria 20 years ago, and nowadays are broadly employed in clinical early detection of psychosis. The schizotypy construct, now dissociated from strict familial risk, also informed research on the liability to develop any psychotic disorder, and in particular schizophrenia-spectrum disorders, even outside clinical settings. Against the historical background of schizotypy it is surprising that evidence from longitudinal studies linking schizotypy, UHR, and conversion to psychosis has only recently emerged; and it still remains unclear how schizotypy may be positioned in high-risk research. Following a comprehensive literature search, we review 18 prospective studies on 15 samples examining the evidence for a link between trait schizotypy and conversion to psychosis in 4 different types of samples: general population, clinical risk samples according to UHR and/or basic symptom criteria, genetic (familial) risk, and clinical samples at-risk for a nonpsychotic schizophrenia-spectrum diagnosis. These prospective studies underline the value of schizotypy in high-risk research, but also point to the lack of evidence needed to better define the position of the construct of schizotypy within a developmental psychopathology perspective of emerging psychosis and schizophrenia-spectrum disorders

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bacterial infections are very common and represent one of the most important reasons of progression of liver failure, development of liver-related complications, and mortality in patients with cirrhosis. In fact, bacterial infections may be a triggering factor for the occurrence of gastrointestinal bleeding, hypervolemic hyponatremia, hepatic encephalopathy, kidney failure, and development of acute-on-chronic liver failure. Moreover, infections are a very common cause of repeated hospitalizations, impaired health-related quality of life, and increased healthcare costs in cirrhosis. Bacterial infections develop as a consequence of immune dysfunction that occurs progressively during the course of cirrhosis. In a significant proportion of patients, infections are caused by gram-negative bacteria from intestinal origin, yet gram-positive bacteria are a frequent cause of infection, particularly in hospitalized patients. In recent years, infections caused by multidrug-resistant bacteria are becoming an important clinical problem in many countries. The reduction of the negative clinical impact of infections in patients with cirrhosis may be achieved by a combination of prophylactic measures, such as administration of antibiotics, to reduce the occurrence of infections in high-risk groups together with early identification and management of infection once it has developed. Investigation on the mechanisms of altered gut microflora, translocation of bacteria, and immune dysfunction may help develop more effective and safe methods of prevention compared to those that are currently available. Moreover, research on biomarkers of early infection may be useful in early diagnosis and treatment of infections. The current manuscript reports an in-depth review and a position statement on bacterial infections in cirrhosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chordomas are very rare bone malignant tumours that have had a shortage of effective treatments for a long time. New treatments are now available for both the local and the metastatic phase of the disease, but the degree of uncertainty in selecting the most appropriate treatment remains high and their adoption remains inconsistent across the world, resulting in suboptimum outcomes for many patients. In December, 2013, the European Society for Medical Oncology (ESMO) convened a consensus meeting to update its clinical practice guidelines on sarcomas. ESMO also hosted a parallel consensus meeting on chordoma that included more than 40 chordoma experts from several disciplines and from both sides of the Atlantic, with the contribution and sponsorship of the Chordoma Foundation, a global patient advocacy group. The consensus reached at that meeting is shown in this position paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this chapter a low-cost surgical navigation solution for periacetabular osteotomy (PAO) surgery is described. Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient’s pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient’s anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient’s pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography (CT) scan is used to visualize the updated orientation of the acetabular fragment. Experiments with plastic bones (7 hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistical difference on the measurement of acetabular component reorientation (anteversion and inclination). In six out of seven hip joints the mean absolute difference was below five degrees for both anteversion and inclination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND For chronic subdural hematoma, placement of a Blake drain with a two-burr-hole craniotomy is often preferred. However, the placement of such drains carries the risk of penetrating the brain surface or damaging superficial venous structures. OBJECTIVE To describe the use of a Nelaton catheter for the placement of a subdural drain in two-burr-hole trephination for chronic subdural hematoma. METHOD A Nelaton catheter was used to guide placement of a Blake drain into the subdural hematoma cavity and provide irrigation of the hematoma cavity. With the two-burr-hole method, the Nelaton catheter could be removed easily via the frontal burr hole after the Blake drain was in place. RESULTS We used the Nelaton catheters in many surgical procedures and found it a safe and easy technique. This method allows the surgeon to safely direct the catheter into the correct position in the subdural space. CONCLUSIONS This tool has two advantages. First, the use of a small and flexible Nelaton catheter is a safe method for irrigation of a chronic subdural hematoma cavity. Second, in comparison with insertion of subdural drainage alone through a burr hole, the placement of the Nelaton catheter in subdural space is easier and the risk of damaging relevant structures such as cortical tissue or bridging veins is lower. Thus this technique may help to avoid complications when placing a subdural drain.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A three-level satellite to ground monitoring scheme for conservation easement monitoring has been implemented in which high-resolution imagery serves as an intermediate step for inspecting high priority sites. A digital vertical aerial camera system was developed to fulfill the need for an economical source of imagery for this intermediate step. A method for attaching the camera system to small aircraft was designed, and the camera system was calibrated and tested. To ensure that the images obtained were of suitable quality for use in Level 2 inspections, rectified imagery was required to provide positional accuracy of 5 meters or less to be comparable to current commercially available high-resolution satellite imagery. Focal length calibration was performed to discover the infinity focal length at two lens settings (24mm and 35mm) with a precision of O.1mm. Known focal length is required for creation of navigation points representing locations to be photographed (waypoints). Photographing an object of known size at distances on a test range allowed estimates of focal lengths of 25.lmm and 35.4mm for the 24mm and 35mm lens settings, respectively. Constants required for distortion removal procedures were obtained using analytical plumb-line calibration procedures for both lens settings, with mild distortion at the 24mm setting and virtually no distortion found at the 35mm setting. The system was designed to operate in a series of stages: mission planning, mission execution, and post-mission processing. During mission planning, waypoints were created using custom tools in geographic information system (GIs) software. During mission execution, the camera is connected to a laptop computer with a global positioning system (GPS) receiver attached. Customized mobile GIs software accepts position information from the GPS receiver, provides information for navigation, and automatically triggers the camera upon reaching the desired location. Post-mission processing (rectification) of imagery for removal of lens distortion effects, correction of imagery for horizontal displacement due to terrain variations (relief displacement), and relating the images to ground coordinates were performed with no more than a second-order polynomial warping function. Accuracy testing was performed to verify the positional accuracy capabilities of the system in an ideal-case scenario as well as a real-world case. Using many welldistributed and highly accurate control points on flat terrain, the rectified images yielded median positional accuracy of 0.3 meters. Imagery captured over commercial forestland with varying terrain in eastern Maine, rectified to digital orthophoto quadrangles, yielded median positional accuracies of 2.3 meters with accuracies of 3.1 meters or better in 75 percent of measurements made. These accuracies were well within performance requirements. The images from the digital camera system are of high quality, displaying significant detail at common flying heights. At common flying heights the ground resolution of the camera system ranges between 0.07 meters and 0.67 meters per pixel, satisfying the requirement that imagery be of comparable resolution to current highresolution satellite imagery. Due to the high resolution of the imagery, the positional accuracy attainable, and the convenience with which it is operated, the digital aerial camera system developed is a potentially cost-effective solution for use in the intermediate step of a satellite to ground conservation easement monitoring scheme.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phytoplankton of a surface strongly desalinated water lens was investigated on the basis of materials collected during Cruise 57 of R/V Akademik Mstislav Keldysh in September 2007. The lens with salinity <18 psu had area of ca. 19000 sq. km and was located in the northwestern part of the Kara Sea near the eastern coast of Novaya Zemlya. It was a specific biotope that had been isolated from surrounding waters for more than three months. In the investigated area 66 algae species were identified. The maximal species diversity was found in the upper layers of the desalinated lens, where species number was 1.5 to 3 times higher than in other parts of the water column. Phytoplankton abundance in the upper layers of the lens was 1.5 to 4.5 times higher than in its lower part and generally higher than below the picnocline. Diatoms were the most abundant group in the upper layers of the lens, while flagellates dominated in the subpicnocline part of the water column. Maximal values of phytoplankton biomass were observed everywhere in the upper layers of the lens, where they were 1.2 to 3.7 times higher than in the lower part of the lens and 1.3 to 7.2 times higher than in the layer below the picnocline. Dinoflagellates generally gave the most contribution to total phytoplankton biomass. Phytoplankton of the desalinated surface lens in the northwestern part of the Kara Sea by its composition and quantitative parameters had the nearest resemblance to a phytocenosis that we observed two weeks later at a shallow desalinated shelf closely adjacent to the Ob estuary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La concentración fotovoltaica (CPV) es una de las formas más prometedoras de reducir el coste de la energía proveniente del sol. Esto es posible gracias a células solares de alta eficiencia y a una significativa reducción del tamaño de la misma, que está fabricada con costosos materiales semiconductores. Ambos aspectos están íntimamente ligados ya que las altas eficiencias solamente son posibles con materiales y tecnologías de célula caros, lo que forzosamente conlleva una reducción del tamaño de la célula si se quiere lograr un sistema rentable. La reducción en el tamaño de las células requiere que la luz proveniente del sol ha de ser redirigida (es decir, concentrada) hacia la posición de la célula. Esto se logra colocando un concentrador óptico encima de la célula. Estos concentradores para CPV están formados por diferentes elementos ópticos fabricados en materiales baratos, con el fin de reducir los costes de producción. El marco óptimo para el diseño de concentradores es la óptica anidólica u óptica nonimaging. La óptica nonimaging fue desarrollada por primera vez en la década de los años sesenta y ha ido evolucionando significativamente desde entonces. El objetivo de los diseños nonimaging es la transferencia eficiente de energía entre la fuente y el receptor (sol y célula respectivamente, en el caso de la CPV), sin tener en cuenta la formación de imagen. Los sistemas nonimaging suelen ser simples, están compuestos de un menor número de superficies que los sistemas formadores de imagen y son más tolerantes a errores de fabricación. Esto hace de los sistemas nonimaging una herramienta fundamental, no sólo en el diseño de concentradores fotovoltaicos, sino también en el diseño de otras aplicaciones como iluminación, proyección y comunicaciones inalámbricas ópticas. Los concentradores ópticos nonimaging son adecuados para aplicaciones CPV porque el objetivo no es la reproducción de una imagen exacta del sol (como sería el caso de las ópticas formadoras de imagen), sino simplemente la colección de su energía sobre la célula solar. Los concentradores para CPV pueden presentar muy diferentes arquitecturas y elementos ópticos, dando lugar a una gran variedad de posibles diseños. El primer elemento óptico que es atravesado por la luz del sol se llama Elemento Óptico Primario (POE en su nomenclatura anglosajona) y es el elemento más determinante a la hora de definir la forma y las propiedades del concentrador. El POE puede ser refractivo (lente) o reflexivo (espejo). Esta tesis se centra en los sistemas CPV que presentan lentes de Fresnel como POE, que son lentes refractivas delgadas y de bajo coste de producción que son capaces de concentrar la luz solar. El capítulo 1 expone una breve introducción a la óptica geométrica y no formadora de imagen (nonimaging), explicando sus fundamentos y conceptos básicos. Tras ello, la integración Köhler es presentada en detalle, explicando sus principios, válidos tanto para aplicaciones CPV como para iluminación. Una introducción a los conceptos fundamentales de CPV también ha sido incluida en este capítulo, donde se analizan las propiedades de las células solares multiunión y de los concentradores ópticos empleados en los sistemas CPV. El capítulo se cierra con una descripción de las tecnologías existentes empleadas para la fabricación de elementos ópticos que componen los concentradores. El capítulo 2 se centra principalmente en el diseño y desarrollo de los tres concentradores ópticos avanzados Fresnel Köhler que se presentan en esta tesis: Fresnel-Köhler (FK), Fresnel-Köhler curvo (DFK) y Fresnel-Köhler con cavidad (CFK). Todos ellos llevan a cabo integración Köhler y presentan una lente de Fresnel como su elemento óptico primario. Cada uno de estos concentradores CPV presenta sus propias propiedades y su propio procedimiento de diseño. Además, presentan todas las características que todo concentrador ha de tener: elevado factor de concentración, alta tolerancia de fabricación, alta eficiencia óptica, irradiancia uniforme sobre la superficie de la célula y bajo coste de producción. Los concentradores FK y DFK presentan una configuración de cuatro sectores para lograr la integración Köhler. Esto quiere decir que POE y SOE se dividen en cuatro sectores simétricos cada uno, y cada sector del POE trabaja conjuntamente con su correspondiente sector de SOE. La principal diferencia entre los dos concentradores es que el POE del FK es una lente de Fresnel plana, mientras que una lente curva de Fresnel es empleada como POE del DFK. El concentrador CFK incluye una cavidad de confinamiento externo integrada, que es un elemento óptico capaz de recuperar los rayos reflejados por la superficie de la célula con el fin de ser reabsorbidos por la misma. Por tanto, se aumenta la absorción de la luz, lo que implica un aumento en la eficiencia del módulo. Además, este capítulo también explica un método de diseño alternativo para los elementos faceteados, especialmente adecuado para las lentes curvas como el POE del DFK. El capítulo 3 se centra en la caracterización y medidas experimentales de los concentradores ópticos presentados en el capítulo 2, y describe sus procedimientos. Estos procedimientos son en general aplicables a cualquier concentrador basado en una lente de Fresnel, e incluyen tres tipos principales de medidas experimentales: eficiencia eléctrica, ángulo de aceptancia y uniformidad de la irradiancia en el plano de la célula. Los resultados que se muestran a lo largo de este capítulo validarán a través de medidas a sol real las características avanzadas que presentan los concentradores Köhler, y que se demuestran en el capítulo 2 mediante simulaciones de rayos. Cada concentrador (FK, DFK y CFK) está diseñado y optimizado teniendo en cuenta condiciones de operación realistas. Su rendimiento se modela de forma exhaustiva mediante el trazado de rayos en combinación con modelos distribuidos para la célula. La tolerancia es un asunto crítico de cara al proceso de fabricación, y ha de ser máxima para obtener sistemas de producción en masa rentables. Concentradores con tolerancias limitadas generan bajadas significativas de eficiencia a nivel de array, causadas por el desajuste de corrientes entre los diferentes módulos (principalmente debido a errores de alineación en la fabricación). En este sentido, la sección 3.5 presenta dos métodos matemáticos que estiman estas pérdidas por desajuste a nivel de array mediante un análisis de sus curvas I-V, y por tanto siendo innecesarias las medidas a nivel de mono-módulo. El capítulo 3 también describe la caracterización indoor de los elementos ópticos que componen los concentradores, es decir, de las lentes de Fresnel que actúan como POE y de los secundarios free-form. El objetivo de esta caracterización es el de evaluar los adecuados perfiles de las superficies y las transmisiones ópticas de los diferentes elementos analizados, y así hacer que el rendimiento del módulo sea el esperado. Esta tesis la cierra el capítulo 4, en el que la integración Köhler se presenta como una buena alternativa para obtener distribuciones uniformes en aplicaciones de iluminación de estado sólido (iluminación con LED), siendo particularmente eficaz cuando se requiere adicionalmente una buena mezcla de colores. En este capítulo esto se muestra a través del ejemplo particular de un concentrador DFK, el cual se ha utilizado para aplicaciones CPV en los capítulos anteriores. Otra alternativa para lograr mezclas cromáticas apropiadas está basada en un método ya conocido (deflexiones anómalas), y también se ha utilizado aquí para diseñar una lente TIR aplanética delgada. Esta lente cumple la conservación de étendue, asegurando así que no hay bloqueo ni dilución de luz simultáneamente. Ambos enfoques presentan claras ventajas sobre las técnicas clásicas empleadas en iluminación para obtener distribuciones de iluminación uniforme: difusores y mezcla caleidoscópica mediante guías de luz. ABSTRACT Concentrating Photovoltaics (CPV) is one of the most promising ways of reducing the cost of energy collected from the sun. This is possible thanks to both, very high-efficiency solar cells and a large decrease in the size of cells, which are made of costly semiconductor materials. Both issues are closely linked since high efficiency values are only possible with expensive cell materials and technologies, implying a compulsory area reduction if cost-effectiveness is desired. The reduction in the cell size requires that light coming from the sun must be redirected (i.e. concentrated) towards the cell position. This is achieved by placing an optical concentrator system on top of the cell. These CPV concentrators consist of different optical elements manufactured on cheap materials in order to maintain low production costs. The optimal framework for the design of concentrators is nonimaging optics. Nonimaging optics was first developed in the 60s decade and has been largely developed ever since. The aim of nonimaging devices is the efficient transfer of light power between the source and the receiver (sun and cell respectively in the case of CPV), disregarding image formation. Nonimaging systems are usually simple, comprised of fewer surfaces than imaging systems and are more tolerant to manufacturing errors. This renders nonimaging optics a fundamental tool, not only in the design of photovoltaic concentrators, but also in the design of other applications as illumination, projection and wireless optical communications. Nonimaging optical concentrators are well suited for CPV applications because the goal is not the reproduction of an exact image of the sun (as imaging optics would provide), but simply the collection of its energy on the solar cell. Concentrators for CPV may present very different architectures and optical elements, resulting in a vast variety of possible designs. The first optical element that sunlight goes through is called the Primary Optical Element (POE) and is the most determinant element in order to define the shape and properties of the whole concentrator. The POE can be either refractive (lens) or reflective (mirror). This thesis focuses on CPV systems based on Fresnel lenses as POE, which are thin and inexpensive refractive lenses able to concentrate sunlight. Chapter 1 exposes a short introduction to geometrical and nonimaging optics, explaining their fundamentals and basic concepts. Then, the Köhler integration is presented in detail, explaining its principles, valid for both applications: CPV and illumination. An introduction to CPV fundamental concepts is also included in this chapter, analyzing the properties of multijunction solar cells and optical concentrators employed in CPV systems. The chapter is closed with a description of the existing technologies employed for the manufacture of optical elements composing the concentrator. Chapter 2 is mainly devoted to the design and development of the three advanced Fresnel Köhler optical concentrators presented in this thesis work: Fresnel-Köhler (FK), Dome-shaped Fresnel-Köhler (DFK) and Cavity Fresnel-Köhler (CFK). They all perform Köhler integration and comprise a Fresnel lens as their Primary Optical Element. Each one of these CPV concentrators presents its own characteristics, properties and its own design procedure. Their performances include all the key issues in a concentrator: high concentration factor, large tolerances, high optical efficiency, uniform irradiance on the cell surface and low production cost. The FK and DFK concentrators present a 4-fold configuration in order to perform the Köhler integration. This means that POE and SOE are divided into four symmetric sectors each one, working each POE sector with its corresponding SOE sector by pairs. The main difference between both concentrators is that the POE of the FK is a flat Fresnel lens, while a dome-shaped (curved) Fresnel lens performs as the DFK’s POE. The CFK concentrator includes an integrated external confinement cavity, which is an optical element able to recover rays reflected by the cell surface in order to be re-absorbed by the cell. It increases the light absorption, entailing an increase in the efficiency of the module. Additionally, an alternative design method for faceted elements will also be explained, especially suitable for dome-shaped lenses as the POE of the DFK. Chapter 3 focuses on the characterization and experimental measurements of the optical concentrators presented in Chapter 2, describing their procedures. These procedures are in general applicable to any Fresnel-based concentrator as well and include three main types of experimental measurements: electrical efficiency, acceptance angle and irradiance uniformity at the solar cell plane. The results shown along this chapter will validate through outdoor measurements under real sun operation the advanced characteristics presented by the Köhler concentrators, which are demonstrated in Chapter 2 through raytrace simulation: high optical efficiency, large acceptance angle, insensitivity to manufacturing tolerances and very good irradiance uniformity on the cell surface. Each concentrator (FK, DFK and CFK) is designed and optimized looking at realistic performance characteristics. Their performances are modeled exhaustively using ray tracing combined with cell modeling, taking into account the major relevant factors. The tolerance is a critical issue when coming to the manufacturing process in order to obtain cost-effective mass-production systems. Concentrators with tight tolerances result in significant efficiency drops at array level caused by current mismatch among different modules (mainly due to manufacturing alignment errors). In this sense, Section 3.5 presents two mathematical methods that estimate these mismatch losses for a given array just by analyzing its full-array I-V curve, hence being unnecessary any single mono-module measurement. Chapter 3 also describes the indoor characterization of the optical elements composing the concentrators, i.e. the Fresnel lenses acting as POEs and the free-form SOEs. The aim of this characterization is to assess the proper surface profiles and optical transmissions of the different elements analyzed, so they will allow for the expected module performance. This thesis is closed by Chapter 4, in which Köhler integration is presented as a good approach to obtain uniform distributions in Solid State Lighting applications (i.e. illumination with LEDs), being particularly effective when dealing with color mixing requirements. This chapter shows it through the particular example of a DFK concentrator, which has been used for CPV applications in the previous chapters. An alternative known method for color mixing purposes (anomalous deflections) has also been used to design a thin aplanatic TIR lens. This lens fulfills conservation of étendue, thus ensuring no light blocking and no light dilution at the same time. Both approaches present clear advantages over the classical techniques employed in lighting to obtain uniform illumination distributions: diffusers and kaleidoscopic lightpipe mixing.