984 resultados para Effective focal length
Resumo:
Enhanced reality visualization is the process of enhancing an image by adding to it information which is not present in the original image. A wide variety of information can be added to an image ranging from hidden lines or surfaces to textual or iconic data about a particular part of the image. Enhanced reality visualization is particularly well suited to neurosurgery. By rendering brain structures which are not visible, at the correct location in an image of a patient's head, the surgeon is essentially provided with X-ray vision. He can visualize the spatial relationship between brain structures before he performs a craniotomy and during the surgery he can see what's under the next layer before he cuts through. Given a video image of the patient and a three dimensional model of the patient's brain the problem enhanced reality visualization faces is to render the model from the correct viewpoint and overlay it on the original image. The relationship between the coordinate frames of the patient, the patient's internal anatomy scans and the image plane of the camera observing the patient must be established. This problem is closely related to the camera calibration problem. This report presents a new approach to finding this relationship and develops a system for performing enhanced reality visualization in a surgical environment. Immediately prior to surgery a few circular fiducials are placed near the surgical site. An initial registration of video and internal data is performed using a laser scanner. Following this, our method is fully automatic, runs in nearly real-time, is accurate to within a pixel, allows both patient and camera motion, automatically corrects for changes to the internal camera parameters (focal length, focus, aperture, etc.) and requires only a single image.
Resumo:
The mechanisms underlying the increase in stress for large mechanical strains of a polymer glass, quantified by the strain-hardening modulus, are still poorly understood. In the present paper we aim to elucidate this matter and present new mechanisms. Molecular-dynamics simulations of two polymers with very different strain-hardening moduli (polycarbonate and polystyrene) have been carried out. Nonaffine displacements occur because of steric hindrances and connectivity constraints. We argue that it is not necessary to introduce the concept of entanglements to understand strain hardening, but that hardening is rather coupled with the increase in the rate of nonaffine particle displacements. This rate increases faster for polycarbonate, which has the higher strain-hardening modulus. Also more nonaffine chain stretching is present for polycarbonate. It is shown that the inner distances of such a nonaffinely deformed chain can be well described by the inner distances of the worm-like chain, but with an effective stiffness length (equal to the Kuhn length for an infinite worm-like chain) that increases during deformation. It originates from the finite extensibility of the chain. In this way the increase in nonaffine particle displacement can be understood as resulting from an increase in the effective stiffness length of the perturbed chain during deformation, so that at larger strains a higher rate of plastic events in terms of nonaffine displacement is necessary, causing in turn the observed strain hardening in polymer glasses.
Resumo:
We present here a method for calibrating an optical see-through Head Mounted Display (HMD) using techniques usually applied to camera calibration (photogrammetry). Using a camera placed inside the HMD to take pictures simultaneously of a tracked object and features in the HMD display, we could exploit established camera calibration techniques to recover both the intrinsic and extrinsic properties of the~HMD (width, height, focal length, optic centre and principal ray of the display). Our method gives low re-projection errors and, unlike existing methods, involves no time-consuming and error-prone human measurements, nor any prior estimates about the HMD geometry.
Resumo:
Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone. The methods are also limited to optical see-through HMDs. Building on our existing HMD calibration method [1], we show here how it is possible to calibrate a non-see-through HMD. A camera is placed inside an HMD displaying an image of a regular grid, which is captured by the camera. The HMD is then removed and the camera, which remains fixed in position, is used to capture images of a tracked calibration object in various positions. The locations of image features on the calibration object are then re-expressed in relation to the HMD grid. This allows established camera calibration techniques to be used to recover estimates of the display’s intrinsic parameters (width, height, focal length) and extrinsic parameters (optic centre and orientation of the principal ray). We calibrated a HMD in this manner in both see-through and in non-see-through modes and report the magnitude of the errors between real image features and reprojected features. Our calibration method produces low reprojection errors and involves no error-prone human measurements.
Resumo:
Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone, and are often limited to optical see-through HMDs. Building on our existing approach to HMD calibration Gilson et al. (2008), we show here how it is possible to calibrate a non-see-through HMD. A camera is placed inside a HMD displaying an image of a regular grid, which is captured by the camera. The HMD is then removed and the camera, which remains fixed in position, is used to capture images of a tracked calibration object in multiple positions. The centroids of the markers on the calibration object are recovered and their locations re-expressed in relation to the HMD grid. This allows established camera calibration techniques to be used to recover estimates of the HMD display's intrinsic parameters (width, height, focal length) and extrinsic parameters (optic centre and orientation of the principal ray). We calibrated a HMD in this manner and report the magnitude of the errors between real image features and reprojected features. Our calibration method produces low reprojection errors without the need for error-prone human judgements.
Resumo:
For the first time, the resonance Raman spectroscopy was used to characterize polymers derived from meta- and para-nitroanilines. In order to improve the polymer structure analysis, other techniques were also used such as FTIR, UV-vis, XRD, XPS, EPR and N K-XANES. The insertion of strong electron-withdrawing groups (NO2) in polyaniline (PANI)-like backbone causes drastic changes in the lower energy charge transfer states, related to the polymer effective conjugation length. The resonance Raman data show that the NO2 moiety has a minor contribution on the CT state in poly(meta-nitroaniline), PMN, while in the poly(para-nitroaniline), PPN, the quinoid structure induced by para-substitution increases the charge density of NO2 groups, causing a more localized chromophore. The characterization of the imine nitrogen and of the protonated segments was done by XPS, N K-XANES and EPR spectroscopies and the lower polymerization degree of PPN, in comparison to PMN, is confirmed by XRD and TG data. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
The people of Ceará state are descended from miscegenation between the Portuguese colonizers and the native population, resulting in a different facial pattern from other populations. It is important that this pattern be thoroughly understood, along with its minimum and maximum values so that they can be assessed and respected, allowing professionals who deal with the craniofacial complex to work more efficiently and scientifically. Aim: To characterize the morphological pattern of individuals from Ceará state, whose father and grandfather are also native from Ceará, in the 10-12 year age group, not submitted to previous orthodontic treatment, in order to determine: 1) the prevalence of occlusal pattern; 2) the prevalence of dental anomalies (DA) and, 3) the skeletal and dental cephalometric characteristics of individuals that present with normal occlusion and harmonious facial pattern. Methodology: A list of 10-12 year-olds was obtained from 515 schools containing 162,713 students (Education Secretariat of Ceará State), from which 234 individuals were examined (107 boys and 157 girls). The assessment criteria adopted were: 1) Angle s Classification System to determine occlusal pattern. The occlusal characteristics were measured through overbite, overjet, crowding and interincisal diastema. 2) DA are anomalies of number, shape, size, eruption and structure and, 3) in the group that presented with normal occlusion, we used cephalometric analysis measures proposed by Downs, Steiner, Tweed, Holdaway, Jacobson and McNamara. Results: 1) 25.8% of the schoolchildren had normal occlusion, 47.5% class I malocclusion, 22.3% class II malocclusion and 4.2% class III malocclusion. No statistically significant difference was found between the age group studied and sex. Thirty percent of the individuals had normal overbite, while 36.7% and 19.7% had increased and reduced overbite, respectively. Normal overjet was found in 33.7% of the individuals, increased overjet in 50% and reduced in 16.3%. Dental crowding was observed in 62.5% of the individuals and the presence of interincisal diastema in 14.8%. 2) The prevalence of DA was 56.1%, 6.8% in the number, 10.8% in shape, 4.1% in size, 34.5% in eruption, 26.4% in structure and 17.4% had more than one DA. No association was found between DA and sex, but DA was significantly associated to malocclusion (p<0.05); 3) there was no association between sex or facial type between the measures of nasal-labial angle, position and effective maxillary length, effective mandibular length and the sagittal relationship between the molars, overjet and overbite, position of upper incisors, lower incisors and between the incisors themselves. There was a difference between sex, on the VERT index and in lower anterior facial height, upper incisor inclination and line-H, between facial types for the occlusal plane angles, mandibular plane, facial axis, lower incisor inclination, mandibular position, upper incisor position, lower anterior facial height, ANB and line-H. It was concluded that: 1) the most prevalent occlusal type was class I malocclusion, with no distinction for sex or age group, and the assessment of occlusal characteristics showed that excessive overbite and overjet were the most predominant findings, along with a high occurrence of tooth crowding; 2) a high prevalence of DA was found, particularly eruption anomalies, not influenced by sex but significantly associated to malocclusion and 3) individuals from Ceará are predominantly brachyfacial, exhibiting a number of similarities inherent to their facial pattern, such as a convex profile, retracted jaw, reduced lower third and protruded lower incisors. This study was multidisciplinary, involving researchers from the areas of epidemiology, radiology and dentistry, thereby meeting the multidisciplinarity requirements of the Postgraduate Program in Health Sciences
Resumo:
Physical parameters of different types of lenses were measured through digital speckle pattern interferometry (DSPI) using a multimode diode laser as light source. When such lasers emit two or more longitudinal modes simultaneously the speckle image of an object appears covered of contour fringes. By performing the quantitative fringe evaluation the radii of curvature as well as the refractive indexes of the lenses were determined. The fringe quantitative evaluation was carried out through the four- and the eight-stepping techniques and the branch-cut method was employed for phase unwrapping. With all these parameters the focal length was calculated. This whole-field multi-wavelength method does enable the characterization of spherical and aspherical lenses and of positive and negative ones as well. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Modelling polymers with side chains is always a challenge once the degrees of freedom are very high. In this study, we present a successful methodology to model poly[2-methoxy-5-(2′-ethyl-hexyloxy)-p-phenylenevinylene] (MEH-PPV) and poly[3-hexylthiophene] (P3HT) in solutions, taking into account the influence of side chains on the polymer conformation. Molecular dynamics and semi-empirical quantum mechanical methods were used for structure optimisation and evaluation of optical properties. The methodology allows to describe structural and optical characteristics of the polymers in a satisfactory way, as well as to evaluate some usual simplifications adopted for modelling these systems. Effective conjugation lengths of 8-14.6 and 21 monomers were obtained for MEH-PPV and P3HT, respectively, in accordance with experimental findings. In addition, anti/syn conformations of these polymers could be predicted based on intrinsic interactions of the lateral branches. © 2013 Copyright Taylor and Francis Group, LLC.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Refractive and profilometric measurements of lenses were performed through holography with a photorefractive Bi12TiO20 crystal as the recording medium. Two properly aligned diode lasers emitting in the red region were employed as light sources. Both lasers were tuned in order to provide millimetric and sub-millimetric synthetic wavelengths. The surfaces of the test lens were covered by a 25-μm opaque plastic tape in order to allow the lens profilometry upon illuminating them with a collimated beam. The resulting holographic images appear covered by interference fringes corresponding to the wavefront geometry of the wave scattered by the lens. For refractive index measurement a diffusely scattering flat surface was positioned behind the uncovered lens which was also illuminated by a plane wave. The resulting contour interferogram describes the form of the wavefront after the beam traveled back and forth through the lens. The fringe quantitative evaluation was carried out through the four-stepping technique and the resulting phase map and the Branch-cut method was employed for phase unwrapping. The only non-optical procedure for lens characterization was the thickness measurement, made by a dial caliper. Exact ray tracing calculation was performed in order to establish a relation between the output wavefront geometry and the lens parameters like radii of curvature, thickness and refractive index. By quantitatively comparing the theoretical wavefront geometry with the experimental results relative uncertainties bellow 3% for refractive index and 1 % for focal length were obtained. © 2008 American Institute of Physics.