883 resultados para ECOCARDIOGRAFIA DOPPLER EN CANINOS
Resumo:
We assessed whether quantitative analysis of Doppler flow velocity waveforms is able to identify subclinical microvascular abnormalities in SLE and whether eigenvector analysis can detect changes not detectable using the resistive index (RI). Fifty-four SLE patients with no conventional cardiovascular risk factors, major organ involvement or retinopathy were compared to 32 controls. Flow velocity waveforms were obtained from the ophthalmic artery (OA), central retinal artery (CRA) and common carotid artery (CA). The waveforms were analysed using eigenvector decomposition and compared between groups at each arterial site. The RI was also determined. The RI was comparable between groups. In the OA and CRA, there were significant differences in the lower frequency sinusoidal components (P <0.05 for each component). No differences were apparent in the CA between groups. Eigenvector analysis of Doppler flow waveforms, recorded in proximity of the terminal vascular bed, identified altered ocular microvascular haemodynamics in SLE. Altered waveform structure could not be identified by changes in RI, the traditional measure of downstream vascular resistance. This analytical approach to waveform analysis is more sensitive in detecting preclinical microvascular abnormalities in SLE. It may hold potential as a useful tool for assessing disease activity, response to treatment, and predicting future vascular complications.
Resumo:
Exoplanet transit and Doppler surveys discover many binary stars during their operation that can be used to conduct a variety of ancillary science. Specifically, eclipsing binary stars can be used to study the stellar mass-radius relationship and to test predictions of theoretical stellar evolution models. By cross-referencing 24 binary stars found in the MARVELS Pilot Project with SuperWASP photometry, we find two new eclipsing binaries, TYC 0272-00458-1 and TYC 1422-01328-1, which we use as case studies to develop a general approach to eclipsing binaries in survey data. TYC 0272-00458-1 is a single-lined spectroscopic binary for which we calculate a mass of the secondary and radii for both components using reasonable constraints on the primary mass through several different techniques. For a primary mass of M 1 = 0.92 ± 0.1 M sun, we find M 2 = 0.610 ± 0.036 M sun, R 1 = 0.932 ± 0.076 R sun, and R 2 = 0.559 ± 0.102 R sun, and find that both stars have masses and radii consistent with model predictions. TYC 1422-01328-1 is a triple-component system for which we can directly measure the masses and radii of the eclipsing pair. We find that the eclipsing pair consists of an evolved primary star (M 1 = 1.163 ± 0.034 M sun, R 1 = 2.063 ± 0.058 R sun) and a G-type dwarf secondary (M 2 = 0.905 ± 0.067 M sun, R 2 = 0.887 ± 0.037 R sun). We provide the framework necessary to apply this analysis to much larger data sets.
Resumo:
The fast ignitor scheme for inertial confinement fusion requires forward driving of the critical density surface by light pressure (hole boring) to allow energy deposition close to the dense fuel. The recession velocity of the critical density surface has been observed to be nu/c = 0.015 at an irradiance of 1.0 x 10(19) W cm(-2) at a wavelength of 1.05 micron, in quantitative agreement with modeling. (C) 1996 American Institute of Physics.
Resumo:
Large parts of the periodic table cannot be cooled by current laser-based methods. We investigate whether zero energy fragmentation of laser cooled fluorides is a potential source of ultracold fluorine atoms. We report new ab initio calculations on the lowest electronic states of the BeF diatomic molecule including spin-orbit coupling, the calculated minima for the valence electronic states being within 1 pm of the spectroscopic values. A four colour cooling scheme based on the A2? ? X2S+ transition is shown to be feasible for this molecule. Multi-Reference Configuration Interaction (MRCI) potentials of the lowest energy Rydberg states are reported for the first time and found to be in good agreement with experimental data. A series of multi-pulse excitation schemes from a single rovibrational level of the cooled molecule are proposed to produce cold fluorine atoms.
Resumo:
The aim of this study was to compare time-domain waveform analysis of second-trimester uterine artery Doppler using the resistance index (RI) with waveform analysis using a mathematical tool known as wavelet transform for the prediction of pre-eclampsia (PE). This was a retrospective, nested case-cohort study of 336 women, 37 of whom subsequently developed PE. Uterine artery Doppler waveforms were analysed using both RI and waveform analysis. The utility of these indices in screening for PE was then evaluated using receiver operating characteristic curves. There were significant differences in uterine artery RI between the PE women and those with normal pregnancy outcome. After wavelet analysis, significant difference in the mean amplitude in wavelet frequency band 4 was noted between the 2 groups. The sensitivity for both Doppler RI and frequency band 4 for the detection of PE at a 10% false-positive rate was 45%. This small study demonstrates the application of wavelet transform analysis of uterine artery Doppler waveforms in screening for PE. Further prospective studies are needed in order to clearly define if this analytical approach to waveform analysis may have the potential to improve the detection of PE by uterine artery Doppler screening.
Resumo:
Abstract Objective To determine if high umbilical artery Doppler (UAD) pulsatility index (PI) is associated with cardio-vascular (CV) risk-factors in children at age 12 years. Methods We studied 195 children at age 12 years who had had in-utero UAD studies performed at 28 weeks gestation. The children were grouped according to whether their umbilical Doppler PI was high (indicating poor feto-placental circulation) or normal. At age 12 years we assessed CV risk factors, including anthropometric measures, blood pressure, pulse wave velocity (a measure of arterial compliance), cardio-respiratory fitness and homocysteine and cholesterol serum levels. Results Compared with children with a normal UAD PI (N=88), the children (N=107) with high UAD PI had higher resting pulse rate (p=0.04), higher pulse wave velocity (p=0.046), higher serum homocysteine levels (p=0.032) and reduced arterial compliance (7.58 v 8.50 m/sec, p=0.029) using univariate analysis. These differences were not present when adjusting for cofounders was modelled. Conclusion High PI on UAD testing in-utero may be associated with increased likelihood of some cardio-vascular risk factors at age 12-years but confounding variables may be as important. Our study raises possible long-term benefits of in-utero UAD measurements.
Resumo:
A counterintuitive scheme to produce ultracold hydrogen via fragmentation of laser cooled diatomic hydrides is presented where the final atomic H temperature is inversely proportional to the mass of the molecular parent. In addition, the critical density for formation of a Bose-Einstein condensate (BEC) at a fixed temperature is reduced by a factor (mH/mMH)3/2 over directly cooled hydrogen atoms. The narrow Feshbach resonances between a S01 atom and hydrogen are well suited to a tiny center of mass energy release necessary during fragmentation. With the support of ab initio quantum chemistry, it is demonstrated that BaH is an ideal diatomic precursor that can be laser cooled to a Doppler temperature of ∼26μK with just two rovibronic transitions, the simplest molecular cooling scheme identified to date. Preparation of a hydrogen atom gas below the critical BEC temperature Tc is feasible with present cooling technology, with optical pulse control of the condensation process.
Resumo:
Wavelet entropy assesses the degree of order or disorder in signals and presents this complex information in a simple metric. Relative wavelet entropy assesses the similarity between the spectral distributions of two signals, again in a simple metric. Wavelet entropy is therefore potentially a very attractive tool for waveform analysis. The ability of this method to track the effects of pharmacologic modulation of vascular function on Doppler blood velocity waveforms was assessed. Waveforms were captured from ophthalmic arteries of 10 healthy subjects at baseline, after the administration of glyceryl trinitrate (GTN) and after two doses of N(G)-nitro-L-arginine-methyl ester (L-NAME) to produce vasodilation and vasoconstriction, respectively. Wavelet entropy had a tendency to decrease from baseline in response to GTN, but significantly increased after the administration of L-NAME (mean: 1.60 ± 0.07 after 0.25 mg/kg and 1.72 ± 0.13 after 0.5 mg/kg vs. 1.50 ± 0.10 at baseline, p < 0.05). Relative wavelet entropy had a spectral distribution from increasing doses of L-NAME comparable to baseline, 0.07 ± 0.04 and 0.08 ± 0.03, respectively, whereas GTN had the most dissimilar spectral distribution compared with baseline (0.17 ± 0.08, p = 0.002). Wavelet entropy can detect subtle changes in Doppler blood velocity waveform structure in response to nitric-oxide-mediated changes in arteriolar smooth muscle tone.
Resumo:
OBJECTIVE: To determine whether an elevated fetal umbilical artery Doppler (UAD) pulsatility index (PI) at 28 weeks' gestation, in the absence of fetal growth restriction (FGR) and prematurity, is associated with adverse neurocognitive outcome in children aged 12 years.
METHODS: Prospective cohort study, comparing children with a normal fetal UAD PI (<90th centile) (n=110) and those with an elevated PI (≥90th centile) (n=40). UAD was performed at 28, 32 and 34 weeks gestation. At 12 years of age, all children were assessed under standardised conditions at Queen's University, Belfast, UK to determine cognitive and behavioural outcomes using the British Ability Score-II and Achenbach Child Behavioural Checklist Parent Rated Version under standardised conditions. Regression analysis was performed, controlling for confounders such as gender, socioeconomic status and age at assessment.
RESULTS: The mean age of follow-up was 12.4 years (±0.5 SD) with 44% of children male (n=63). When UAD was assessed at 28 weeks, the elevated fetal UAD group had lower scores in cognitive assessments of information processing and memory. Parameters included (1) recall of objects immediate verbal (p=0.002), (2) delayed verbal (p=0.008) and (3) recall of objects immediate spatial (p=0.0016). There were no significant differences between the Doppler groups at 32 or 34 weeks' gestation.
CONCLUSIONS: An elevated UAD PI at 28 weeks' gestation in the absence of FGR or prematurity is associated with lower scores of declarative memory in children aged 12 years. A potential explanation for this is an element of placental insufficiency in the presence of the appropriately grown fetus, which affects the development of the fetal hippocampus and information processing and memory long-term. These findings, however, had no impact on overall academic ability, mental processing and reasoning or overall behavioural function.
Resumo:
In this work parameters of Mg-doped GaN samples were studied using positron annihilation spectroscopy and analyzed. It is shown that gallium vacancies exist in an unintentionally doped sample. Next, the sample with higher concentration of Mg and low growth temperature contains vacancy clusters. In case of low concentration of Mg the growth temperature does not affect the formation of defects. Analog electronics can be replaced by a modern digital device. While promising a high quantity of benefits, the performance of these digitizers requires thorough adjustment. A 14-bit two channel digitizer has been tested in order to achieve better performance than the one of a traditional analog setup, and the adjustment process is described. It has been shown that the digital device is unable to achieve better energy resolution, but it is quite close to the corresponding attribute of the available analog system, which had been used for measurements in Mg-doped GaN.
Resumo:
Tesis (Especialidad en Endodoncia) UANL, 2010.
Resumo:
Tesis ( Maestría en Ciencias Odontológicas con Especialidad en Ortodoncia) U.A.N.L.
Resumo:
Nous avons mené une étude prospective randomisée dans le but de comparer l'effet de l'irrigation du cathéter de type PICC avec deux types d'anticoagulants: Héparine standard et Tinzaparine, une héparine de faible poids moléculaire. Notre étude s'adresse aux patients de la clinique externe d'oncologie de l'hôpital Maisonneuve-Rosemont. Entre début Mai 2005 et Mars 2008, nous avons recruté 131 patients dont 70 ont été randomisés. Parmi les 61 patients exclus, 23 n'ont pas rencontré les critères d'inclusion, 30 ont refusé de participer et 8 ne sont pas inclus pour d'autres raisons. Sur les 70, 36 sujets sont randomisés dans le groupe Héparine standard et 34 dans le groupe Tinzaparine. La population en intention de traiter comprend 65 sujets dont 32 dans le groupe Héparine standard et 33 dans le groupe Tinzaparine. Le médicament a été administré pendant un mombre maximal de 30 jours et les sujets ont été suivis pendant 90 jours. La thrombose veineuse associée au cathéter (TVAC) a été objectivée par une phlébographie ou une échographie-Doppler à la fin de la période de 30 jours suivant l'installation du cathéter. L'incidence de la TVAC sur 30 jours est de 14,39 par 1000 cathéter-jours (IC à 95%:[9,0;19,79]/1000 cathéter-jours ou 41,5% (27/65). L'incidence de la thrombose veineuse profonde (TVP) symptômatique du membre supérieur sur la période de suivi de 90 jours est de 0,41 par 1000 cathéter-jours (IC à 95%:[0,08;0,81]/1000 cathéter-jours ou 3% (2/65). Nous n'avons observé aucune différence entre les deux groupes par rapport à la fréquence de la TVAC ni de la TVP. Nous ne pouvons conclure à une différence dans l'efficacité de la Tinzaparine par rapport à l'Héparine standard dans la prévention de la TVAC.