984 resultados para Cochlear implant. speech perception, users


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This dissertation examines the relationship between frequency response and word-discrimination performance of hearing-impaired persons. Three questions are addressed: does the restoration of the normal field-to-eardrum transfer function improve word discrimination; is the restoration of the normal shape of the audibility curve (uniform hearing level at all frequencies) beneficial to hearing-impaired listeners; and can speech discrimination be improved by an extension of the present narrow-band response in hearing aids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses a study done with chinchillas and their ability to organize speech sounds into auditory concepts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper examines the factors that are significant predictors of spoken language acquisition in children with cochlear implants. Factors identified include age of cochlear implantation, age of diagnosis, age started hearing aid use, parent educational level, and family income.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A longitudinal study observing cochlear implant recipients' social skills using ratings from their parents and the students themselves over time. The study looked at how adolescents using cochlear implants rate their own social skills compared to an age matched normative group of hearing students, and compared these ratings with social skills ratings obtained from their parents. The study also compared social ratings in adolescence to previous ratings of the same children obtained in elementary school.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We examine the efficacy two volume spatial registration of pre and postoperative clinical computed tomography (CT) imaging to verify post-operative electrode array placement in cochlear implant (CI) patients. To measure the degree of accuracy with which the composite image predicts in-vivo placement of the array, we replicate the CI surgical process in cadaver heads. Pre-operative, post-operative, micro CT imaging and histology are utilized for verification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Auditory-visual speech perception testing was completed using wordandconsonant-level stimuli in individuals with known degrees of dementia of theAlzheimer’s type. The correlations with the cognitive measures and the speechperception measures (A-only, V-only, AV, VE or AE) did not reveal significantrelationships.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is a guidebook for parents and educators to further understand the cochlear implant process from candidacy to surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The cognitive bases of language impairment in specific language impairment (SLI) and autism spectrum disorders (ASD) were investigated in a novel non-word comparison task which manipulated phonological short-term memory (PSTM) and speech perception, both implicated in poor non-word repetition. Aims: This study aimed to investigate the contributions of PSTM and speech perception in non-word processing and whether individuals with SLI and ASD plus language impairment (ALI) show similar or different patterns of deficit in these cognitive processes. Method & Procedures: Three groups of adolescents (aged 14–17 years), 14 with SLI, 16 with ALI, and 17 age and non-verbal IQ matched typically developing (TD) controls, made speeded discriminations between non-word pairs. Stimuli varied in PSTM load (two- or four-syllables) and speech perception load (mismatches on a word-initial or word-medial segment). Outcomes & Results: Reaction times showed effects of both non-word length and mismatch position and these factors interacted: four-syllable and word-initial mismatch stimuli resulted in the slowest decisions. Individuals with language impairment showed the same pattern of performance as those with typical development in the reaction time data. A marginal interaction between group and item length was driven by the SLI and ALI groups being less accurate with long items than short ones, a difference not found in the TD group. Conclusions & Implications: Non-word discrimination suggests that there are similarities and differences between adolescents with SLI and ALI and their TD peers. Reaction times appear to be affected by increasing PSTM and speech perception loads in a similar way. However, there was some, albeit weaker, evidence that adolescents with SLI and ALI are less accurate than TD individuals, with both showing an effect of PSTM load. This may indicate, at some level, the processing substrate supporting both PSTM and speech perception is intact in adolescents with SLI and ALI, but also in both there may be impaired access to PSTM resources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Word deafness is a rare condition where pathologically degraded speech perception results in impaired repetition and comprehension but otherwise intact linguistic skills. Although impaired linguistic systems in aphasias resulting from damage to the neural language system (here termed central impairments), have been consistently shown to be amenable to external influences such as linguistic or contextual information (e.g. cueing effects in naming), it is not known whether similar influences can be shown for aphasia arising from damage to a perceptual system (here termed peripheral impairments). Aims: This study aimed to investigate the extent to which pathologically degraded speech perception could be facilitated or disrupted by providing visual as well as auditory information. Methods and Procedures: In three word repetition tasks, the participant with word deafness (AB) repeated words under different conditions: words were repeated in the context of a pictorial or written target, a distractor (semantic, unrelated, rhyme or phonological neighbour) or a blank page (nothing). Accuracy and error types were analysed. Results: AB was impaired at repetition in the blank condition, confirming her degraded speech perception. Repetition was significantly facilitated when accompanied by a picture or written example of the word and significantly impaired by the presence of a written rhyme. Errors in the blank condition were primarily formal whereas errors in the rhyme condition were primarily miscues (saying the distractor word rather than the target). Conclusions: Cross-modal input can both facilitate and further disrupt repetition in word deafness. The cognitive mechanisms behind these findings are discussed. Both top-down influence from the lexical layer on perceptual processes as well as intra-lexical competition within the lexical layer may play a role.  

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigates whether mothers who have children with cochlear implants fine-tune their own vocabulary and sentence complexity to that of their child. Whether and how fine-tuning leads to faster growth in these language skills is explored.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of cochlear implant (CI) in children enables the development of listening and communication skills, allowing the child's progress in school and to be able to obtain, maintain and carry out an occupation. However, the progress after the CI has different results in some children, because many children are able to interact and participate in society, while others develop limited ability to communicate verbally. The need for a better understanding of CI outcomes, besides hearing and language benefits, has spurred the inclusion of quality of life measurements (QOL) to assess the impact of this technology. OBJECTIVE: Identify the key aspects of quality of life assessed in children with cochlear implant. METHOD: Through a systematic literature review, we considered publications from the period of 2000 to 2011. CONCLUSION: We concluded that QOL measurements in children include several concepts and methodologies. When referring to children using CI, results showed the challenges in broadly conceptualizing which quality of life domains are important to the child and how these areas can evolve during development, considering the wide variety of instruments and aspects evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Telephone communication is a challenge for many hearing-impaired individuals. One important technical reason for this difficulty is the restricted frequency range (0.3-3.4 kHz) of conventional landline telephones. Internet telephony (voice over Internet protocol [VoIP]) is transmitted with a larger frequency range (0.1-8 kHz) and therefore includes more frequencies relevant to speech perception. According to a recently published, laboratory-based study, the theoretical advantage of ideal VoIP conditions over conventional telephone quality has translated into improved speech perception by hearing-impaired individuals. However, the speech perception benefits of nonideal VoIP network conditions, which may occur in daily life, have not been explored. VoIP use cannot be recommended to hearing-impaired individuals before its potential under more realistic conditions has been examined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cochlear implants have been of great benefit in restoring auditory function to individuals with profound bilateral sensorineural deafness. The implants are used to directly stimulate auditory nerves and send a signal to the brain that is then interpreted as sound. This project focuses on the development of a surgical positioning tool to accurately and effectively place an array of stimulating electrodes deep within the cochlea. This will lead to improved efficiency and performance of the stimulating electrodes, reduced surgical trauma to the cochlea, and as a result, improved overall performance to the implant recipient. The positioning tool reported here consists of multiple fluidic chambers providing localized curvature control along the length of the attached silicon electrode array. The chambers consist of 200μm inner diameter PET (polyethylene therephthalate) tubes with 4μm wall thickness. The chambers are molded in a tapered helical configuration to correspond to the cochlear shape upon relaxation of the actuators. This ensures that the optimal electrode placement within the cochlea is retained after the positioning tool becomes dormant (for chronic implants). Actuation is achieved by injecting fluid into the PET chambers and regulating the fluidic pressure. The chambers are arranged in a stacked, overlapping design to provide fluid connectivity with the non-implantable pressure controller and allow for local curvature control of the device. The stacked tube configuration allows for localized curvature control of various areas along the length of the electrode and additional stiffening and actuating power towards the base. Curvature is affected along the entire length of a chamber and the result is cumulative in sections of multiple chambers. The actuating chambers are bonded to the back of a silicon electrode array.