997 resultados para CYCLIC VOLTAMMETRIC DEPOSITION


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Peculiar reduction pathways of the complexes fac-[Re(imH)(CO)3(phen)]+ and fac-[Re(imCH3)(CO)3(phen)]+ (imH = imidazole, imCH3 = N-methylimidazole and phen = 1,10-phenanthroline) have been unravelled by performing combined cyclic voltammetric and in situ IR spectroelectrochemical experiments. In the temperature range of 293–233 K, the initial reduction of the phen ligand in [Re(imH)(CO)3(phen)]+ results in irreversible conversion of the imidazole ligand to 3-imidazolate by a rapid phen•−→ imH intramolecular electron transfer coupled with N H bond cleavage. This process is followed by second phen-localized 1e− reduction producing [ReI(3-im−)(CO)3(phen•−)]−, similar to the analogous 2,2'-bipyridine complex. In contrast to the bpy analogue, the stability of the phen•−-containing complexes is significantly affected by lowering the temperature. At 233 K, a secondary reaction occurs in both [Re(3-im−)(CO)3(phen•−)]− and [Re(imCH3)(CO)3(phen•−)]. The resulting products exhibit v(CO) wavenumbers indistinguishable from those of the parent phen•− complexes; however, their oxidation occurs at a considerably more positive electrode potential. It is proposed that these species are produced by a new C C bond formation between the C(2) site of 3-im− or imCH3 and the C(2) site of the phen•−ligand.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Group 6 complexes of the type [M(CO)4(bpy)] (M=Cr, Mo, W) are capable of behaving as electrochemical catalysts for the reduction of CO2 at potentials less negative than those for the reduction of the radical anions [M(CO)4(bpy)].−. Cyclic voltammetric, chronoamperometric and UV/Vis/IR spectro-electrochemical data reveal that five-coordinate [M(CO)3(bpy)]2− are the active catalysts. The catalytic conversion is significantly more efficient in N-methyl-2-pyrrolidone (NMP) compared to tetrahydrofuran, which may reflect easier CO dissociation from 1e−-reduced [M(CO)4(bpy)].− in the former solvent, followed by second electron transfer. The catalytic cycle may also involve [M(CO)4(H-bpy)]− formed by protonation of [M(CO)3(bpy)]2−, especially in NMP. The strongly enhanced catalysis using an Au working electrode is remarkable, suggesting that surface interactions may play an important role, too.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The addition of 0.5 mM catechol is shown to accelerate the degradation and mineralization of the anionic surfactant DOWFaX (TM) 2A1 (sodium dodecyldiphenyloxide disulfonate) under conventional Fenton reaction conditions (Fe(II) plus H(2)O(2) at pH 3). The catalytic effect causes a 3-fold increase in the initial rate (up to ca. 20 min) of conversion of the surfactant to oxidation products (apparent first-order rate constants of 0.021 and 0.061 min(-1) in the absence and presence of catechol, respectively). Although this catalytic rate increase persists for a certain amount of time after complete disappearance of catechol itself (ca. 8 min), the reaction rate begins to decline slowly after the initial 20 min towards that observed in the absence of added catechol. Total organic carbon (TOC) measurements of net mineralization and cyclic voltammetric and high performance liquid chromatographic (HPLC) measurements of the initial rate of reaction of catechol and the surfactant provide insight into the role of catechol in promoting the degradation of the surfactant and of degradation products as the eventual inhibitors of the Fenton reaction. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work presents a cyclic voltammetry study of the polyaniline/polyluminol copolymer on platinum electrodes. The results show that under determined conditions it is possible to obtain the copolymer deposited on a metallic surface. The luminol presence clearly affects the oxidation of aniline in the nucleation process and, additionally, changes the cyclic voltammetric characteristics of the obtained material. In this aspect, the copolymer presents hybrid characteristics when compared to the polyaniline and polyluminol separately obtained and seems to present intermediary conductivity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The oxidative electrochemistry of [CpFe(CO)2]2, 1 (Cp = [η5-C5H5]–), was examined in detail in ionic liquids (ILs) composed of ions of widely varying Lewis acid−base properties. Cyclic voltammetric responses were strongly dependent on the nucleophilic properties of the IL anion, but all observations are consistent with the initial formation of 1+ followed by attack from the IL anion. In [NTf2]–-based ILs ([NTf2]– = bis(trifluoromethylsulfonyl)amide), the process shows nearly ideal chemical reversibility as the reaction between 1+ and [NTf2]– is very slow. This is highly significant, as 1+ is known to be highly susceptible to nucleophilic attack and its stability indicates a remarkable lack of coordinating ability of these ILs. In 1-methyl-3-butylimidazolium hexafluorophosphate, [bmim][PF6], the oxidation of 1 is still largely reversible, but there is more pronounced evidence of [PF6]– coordination. In contrast, 1 exhibits an irreversible two-electron oxidation process in a dicyanamide-based IL. This overall oxidation process is thought to proceed via an ECE mechanism, details of which are presented. Rate constants were estimated by fitting the experimental data to digital simulations of the proposed mechanism. The use of [NTf2]–-based ILs as a supporting electrolyte in CH2Cl2 was examined by using this solvent/electrolyte as a medium in which to perform bulk electrolyses of 1 and 1*, the permethylated analogue [Cp*Fe(CO)2]2 (Cp* = [η5-C5(CH3)5]–). These cleanly yielded the corresponding binuclear radical-cation species, 1+ and 1*+, which were subsequently characterized by electron paramagnetic resonance (EPR) spectroscopy. In addition to the above oxidation studies, the reduction of 1 was studied in each of the ILs; differences in cathodic peak potentials are attributed, in part, to ion-pairing effects. This study illustrates the wide range of electrochemical environments available with ILs and demonstrates their utility for the investigation of the redox properties of metal carbonyls and other organometallic compounds.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The potential of a quasi-reference electrode can be determined by introducing an internal reference redox system (IRRS) which comprises either the oxidizable or reducible form of a reversible (and, ideally, outer-sphere) redox couple and then observing the cyclic voltammetric responses. The objective is to choose the IRRS so that the cyclic voltammetric response for the simultaneously present electroactive analyte system (ANS) can be observed independently of the IRRS response. We identify three fundamental paradigms describing the relative positioning of the IRRS and ANS on the potential scale, the operative redox components for the IRRS and ANS, and the starting potential (E start), reversing potential (E rev), and ending potential (E end) for the cyclic voltammetric scan as follows: paradigm A, an optimal paradigm which can produce completely independent cyclic voltammetric responses for the IRRS or for ANS; paradigm B, a less-than-optimal paradigm which can produce an independent cyclic voltammetry (CV) response for the ANS or a mixed response for the IRRS with that response on top of the ANS response; paradigm C, a problematic paradigm that can produce an independent CV response for the IRRS or a mixed response for the ANS with that response on top of the IRRS response; and any mixed response produces a thermodynamically favored redox cross-reaction which couples the IRRS and ANS systems and which can complicate the analysis of the ANS and IRRS responses. The conclusion is that paradigm C is to be avoided.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The electrochemical behavior of Cu-xAl alloys, with 11 wt%less than or equal to x less than or equal to 15wt%, in 0.5 M H2SO4 was studied by means of open-circuit potential decay measurements, quasi-stationary and fast cyclic voltammetry, and electrochemical impedance spectroscopy. Some of the alloys (x less than or equal to 14%), when quenched formed martensitic structures. Alloys with greater than or equal to 13% showed a little square-shaped phase when quenched from temperatures around 800 degrees C. It was observed that in sulfuric medium, these formations were dealuminized differently than the martensitic phase. The values of the rest potentials are more influenced by the heat treatment rather than by the alloy composition. An anodic Tafel slope of ca. 60 mV/decade was observed for all the alloys, independently of the heat treatment. This is explained in terms of a competition between two processes: copper oxidation and copper(I) deproportionation. In the cyclic voltammetric experiments it was observed an anodic current peak, related with copper oxidation with a possible formation of some interfacial species, and a cathodic current peak during the reverse potential scan, associated with the reduction of soluble species and/or of the film. The AC Impedance data were interpreted in terms of electric equivalent circuits.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Pt-Ir microelectrode modified through one step, electropolymerization is proposed for the isocitrate amperometric biosensor construction. The enzyme (isocitrate dehydrogenase-ICDH), coenzyme (NADP(+)) and mediator (Meldola's Blue) were immobilized onto the microelectrode surface in one step from a PIPES buffer solution containing pyrrole. The optimized experimental conditions were 25 cycles of cyclic voltammetric in a solution containing 3.58 10(-5) mol l(-1) of mediator, 3.51 10(-4) mol l(-1) of coenzyme and 2.68 U ml(-1) of enzyme. In contrast to the biosensor for isocitrate reported in literature, just one enzyme was immobilized and no coenzyme addition in the solution of analysis was necessary. Catalytic currents were proportional to the isocitrate concentration between 7.7 10(-6) and 1.04 10(-4) mol l(-1), showing good repeatability. The detection limit of the proposed biosensor was 3.50 10(-6) mol l(-1), the response time was lower than 20 s, the lifetime was about 30 determinations and no significant interference of sugars and citric acid was verified. Orange juice samples were analysed by both methodology biosensor and spectrophotometric commercial kit, and the obtained results presented a good correlation. The data demonstrated that the developed biosensor is suitable for isocitrate determination in orange juice without matrix interferences. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The cyclic voltammetric behavior of acetaldehyde and the derivatized product with 2,4-dinitrophenylhydrazine (DNPHi) has been studied at a glassy carbon electrode. This study was used to optimize the best experimental conditions for its determination by high-performance liquid chromatographic (HPLC) separation coupled with electrochemical detection. The acetaldehyde-2,4-dinitrophenyl.hydrazone (ADNPH) was eluted and separated by a reversed-phase column, C-18, under isocratic conditions with the mobile phase containing a binary mixture of methanol/LiCl(aq) at a concentration of 1.0 x 10(-3) M (80:20 v/v) and a flow rate of 1.0 mL min(-1). The optimum condition for the electrochemical detection of ADNPH was +1.0 V vs. Ag/AgCl as a reference electrode. The proposed method was simple, rapid (analysis time 7 min) and sensitive (detection limit 3.80 mu g L-1) at a signal-to-noise ratio of 3:1. It was also highly selective and reproducible [standard deviation 8.2% +/- 0.36 (n = 5)]. The analytical curve of ADNPH was linear over the range of 3-300 mg L-1 per injection (20 mu L), and the analytical recovery was > 99%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A study on the electrochemical behavior of histamine species in aqueous medium is described. A glassy carbon electrode chemically modified with copper (II) hexacyanoferrate (CuHCFe) film and covered with Nafion® film was employed. The interaction between the analyte and the CuHCFe film can be demonstrated by a decrease in both the cathodic and anodic peak currents at 0.68V (vs. Ag/AgCl), attributed to the film and the appearance of new peak current at 0.47V. Cyclic voltammetric parameters obtained for histamine indicate the formation of stable complex between histamine adsorbed at the electrode surface. The dependence of peak currents on the concentration of the analyte is not linear in the employed work range, indicating the presence of a coupled chemical reaction in the electrodic process. © 2010 by ESG.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Procymidone, a potentially carcinogenic and mutagenic pesticide, can contribute to environmental and human contamination when applied to apple crops. In this work, we propose a reliable and sensitive method to determine procymidone in Brazilian apples. The method involves differential pulse (DPV) and square-wave voltammetry (SWV) techniques on a glassy carbon electrode. In a supporting electrolyte solution of 0.5 mol L−1 NaOH, procymidone undergoes an irreversible one-electron oxidation at +1.42 V by cyclic voltammetric vs. Ag|AgCl, KCl 3 M reference electrode. The proposed DPV and SWV methods have a good linear response in the 8.00–20.0 mg L−1 range, with limits of detection (LOD) of 0.678 and 0.228 mg L−1, respectively, in the absence of the matrix. We obtained improved LOD (0.097 mg L−1) in the presence of apple matrix and the supporting electrolyte solution. We used three commercial apple samples to evaluate recovery, and we achieved recovery percentages ranging from 94.6 to 110 % for procymidone determinations. We also tested the proposed voltammetric method for reproducibility, repeatability, and potential interferents, and the results were satisfactory for electroanalytical purposes.