252 resultados para CAPACITOR
Resumo:
Polychlorinated biphenyls (PCBs) are carcinogenic. Estimating PCB half-life in the body based on levels in sera from exposed workers is complicated by the fact that occupational exposure to PCBs was to commercial PCB products (such as Aroclors 1242 and 1254) comprised of varying mixtures of PCB congeners. Half-lives were estimated using sera donated by 191 capacitor manufacturing plant workers in 1976 during PCB use (1946-1977), and post-exposure (1979, 1983, and 1988). Our aims were to: (1) determine the role of covariates such as gender on the half-life estimates, and (2) compare our results with other published half-life estimates based on exposed workers. All serum PCB levels were adjusted for PCB background levels. A linear spline model with a single knot was used to estimate two separate linear equations for the first two serum draws (Equation A) and the latter two (Equation B). Equation A gave half-life estimates of 1.74 years and 6.01 years for Aroclor 1242 and Aroclor 1254, respectively. Estimates were 21.83 years for Aroclor 1242 and 133.33 years for Aroclor 1254 using Equation B. High initial body burden was associated with rapid PCB elimination in workers at or shortly after the time they were occupationally exposed and slowed down considerably when the dose reached background PCB levels. These concentration-dependent half-life estimates had a transition point of 138.57 and 34.78 ppb for Aroclor 1242 and 1254, respectively. This result will help in understanding the toxicological and epidemiological impact of exposure to PCBs in humans.
Resumo:
PURPOSE: Multinuclear magnetic resonance spectroscopy and imaging require a radiofrequency probe capable of transmitting and receiving at the proton and non-proton frequencies. To minimize coupling between probe elements tuned to different frequencies, LC (inductor-capacitor) traps blocking current at the (1) H frequency can be inserted in non-proton elements. This work compares LC traps with LCC traps, a modified design incorporating an additional capacitor, enabling control of the trap reactance at the low frequency while maintaining (1) H blocking. METHODS: Losses introduced by both types of trap were analysed using circuit models. Radiofrequency coils incorporating a series of LC and LCC traps were then built and evaluated at the bench. LCC trap performance was then confirmed using (1) H and (13) C measurements in a 7T human scanner. RESULTS: LC and LCC traps both effectively block interaction between non-proton and proton coils at the proton frequency. LCC traps were found to introduce a sensitivity reduction of 5±2%, which was less than half of that caused by LC traps. CONCLUSION: Sensitivity of non-proton coils is critical. The improved trap design, incorporating one extra capacitor, significantly reduces losses introduced by the trap in the non-proton coil. Magn Reson Med 72:584-590, 2014. © 2013 Wiley Periodicals, Inc.
Resumo:
O trabalho teve como objetivo avaliar modelos de calibração para dois tipos de guias de onda de TDR, referentes a dois equipamentos (Trase System e TDR 100), acopladas diretamente ao analisador de umidade ou a multiplexadores. Amostras de três tipos de solo foram acondicionadas em segmentos de tubos de PVC e saturadas. Dois tipos de guias de onda de três hastes, com capacitor e com resistor foram inseridas dentro de cada segmento de tubo com solo e conectadas a dois equipamentos de TDR, diretamente no testador de cabos ou via multiplexadores. Dados de umidade obtidos por gravimetria e da constante dielétrica foram tomados em cada coluna durante a secagem do solo da saturação até umidades próximas do limite inferior de disponibilidade de água por meio de leituras com as guias de onda conectadas ao testador de cabos e conectadas ao multiplexador. Um modelo polinomial cúbico foi ajustado aos dados da constante dielétrica do solo (épsilon) e da correspondente umidade (teta) e cinco modelos de determinação de q em função de e foram testados quanto ao desempenho. Os resultados mostraram que não houve diferença significativa na calibração das guias de onda com capacitor para uso com a TDR Trase System, considerando a conexão das guias ao analisador de umidade ou a multiplexadores. No caso da TDR 100, as guias de onda com resistor devem ser calibradas conforme o seu uso. O modelo cúbico foi o de melhor desempenho seguido pelo modelo de Roth que estimou, com boa exatidão, os valores da constante dielétrica e da umidade com a mais próximo de 0,5 para as guias de onda com capacitor que com as guias com resistor.
Resumo:
A medição da capacitância e da condutância de um capacitor contendo amostras de trigo permite a determinação de duas de suas propriedades dielétricas: a permissividade relativa (épsilon') e o fator de perda dielétrica (épsilon"). A utilização dessas propriedades, medidas simultaneamente em duas freqüências de oscilação do campo elétrico, permite reduzir ou eliminar o efeito da massa específica aparente na determinação do teor de umidade do trigo. Tal procedimento torna possível o monitoramento contínuo e em tempo real, sem a necessidade de retirar amostras, do teor de umidade de uma coluna de grãos em movimento, situação em que ocorrem as maiores variações na massa específica do produto. O objetivo deste trabalho consistiu na obtenção de equações que permitam reduzir ou eliminar o efeito da massa específica na determinação em linha do teor de umidade do trigo. Foram utilizadas amostras das variedades Hussar, Mercia e Hereward com teor de umidade entre 11% e 22% b.u. e massa específica no intervalo 666 kg m-3 <= ro <= 873 kg m-3. A equação que apresentou melhor desempenho permite calcular o teor de umidade do trigo com erros-padrão de calibração e de predição de 0,4 e 0,5 ponto percentual, respectivamente.
Resumo:
Background: Though commercial production of polychlorinated biphenyls was banned in the United States in 1977, exposure continues due to their environmental persistence. Several studies have examined the associationbetween environmental polychlorinated biphenyl exposure and modulations of the secondary sex ratio, with conflicting results.Objective: Our objective was to evaluate the association between maternal preconceptional occupational polychlorinated biphenyl exposure and the secondary sex ratio.Methods: We examined primipara singleton births of 2595 women, who worked in three capacitor plants at least one year during the period polychlorinated biphenyls were used. Cumulative estimated maternal occupationalpolychlorinated biphenyl exposure at the time of the infant's conception was calculated from plant-specific job exposure matrices. A logistic regression analysis was used to evaluate the association between maternalpolychlorinated biphenyl exposure and male sex at birth (yes/no).Results: Maternal body mass index at age 20, smoking status, and race did not vary between those occupationally exposed and those unexposed before the child's conception. Polychlorinated biphenyl-exposed mothers were, however, more likely to have used oral contraceptives and to have been older at the birth of their first child than non-occupationally exposed women. Among 1506 infants liveborn to polychlorinated biphenyl-exposedprimiparous women, 49.8% were male; compared to 49.9% among those not exposed (n = 1089). Multivariate analyses controlling for mother's age and year of birth found no significant association between the odds of amale birth and mother's cumulative estimated polychlorinated biphenyl exposure to time of conception.Conclusions: Based on these data, we find no evidence of altered sex ratio among children born to primiparous polychlorinated biphenyl-exposed female workers.
Resumo:
Suuritehoisissa pumppu- ja puhallinkäytöissä käytetään usein suurnopeusmoottoria,jota syötetään välijännitteellä. Suurjännitetaajuudenmuuttajat ovat kalliita, eikä niitä ole aina edes mahdollista valmistaa. Tutkimuksen kohteena on rinnakkaisilla pienjännitetaajuudenmuuttajilla toteutettu sähkökäyttö, jossa pienjännite nostetaan moniensiöisellä muuntajalla suurjännitteeksi (6,6 kV) ja syötetään edelleen kuormana olevalle suurnopeusmoottorille. Opinnäytetyössä tutkitaan moniensiöisen muuntajan syöttöä rinnakkaisilla taajuudenmuuttajilla sekä niiden aiheuttamia häiriöitä toisilleen. Työssä tutkitaan myös harmonisten yliaaltojen vaikutuksia muuntajan häviöihin ja magnetointiominaisuuksiin. Taajuudenmuuttajan lähtöjännite ja -virta suodatetaan sinisuotimella, jonka parametreja simuloidaan Simulink- ohjelmistolla. Tavoite on löytää optimaaliset parametrit taajuudenmuuttajanlähtösuotimelle käyrämuotojen ja suotimeen jäävän tehon suhteen. Työssä tarkasteltiin sinisuodinta, johon jää 3 prosenttia syöttöjännitteestä. LC-suodin kompensoi sähkökäytön loistehon lähes kokonaan, joten taajuudenmuuttajien antotehon kannalta suotimet ovat perusteltuja. Taajuudenmuuttajan näennäisteho putoaa 22 prosenttia, joten taajuudenmuuttajat voidaan vastaavasti mitoittaa pienemmiksi.
Resumo:
We have studied the abrupt and hysteretic changes of resistance in MgO-based capacitor devices. The switching behavior is discussed in terms of the formation and rupture of conduction filaments due to the migration of structural defects in the electric field, together with the redox events which affects the mobile carriers. The results presented in this paper suggest that MgO transparent films combining ferromagnetism and multilevel switching characteristics might pave the way for a new method for spintronic multibit data storage.
Resumo:
The aim of this work was to make an active front end from IGBTs for a multilevel inverter. The work was done for Mosart II, a long term still ongoing Vacon Oyj project. The purpose of the AFE is to balance the DC-voltage and to put the returning power back to the grid instead of the breaking chopper and the capacitor. With a diode rectifier the bridge only allows power to pass in one direction and the switching times are not controllable. That means the rectifier always takes the highest phase and the phases are always conducting the same 120◦. With an AFE it is possible to actively change the rectifiers switching pattern. A diode bridge also generates much greater losses than an IGBT bridge. With these arguments it is rational to start researching the possibility of an AFE in a multilevel inverter.
Resumo:
Three compounds have been synthesized with formulae [3-MeRad][Ni(dmit)2] (1), [4-MeRad][Ni(dmit)2] (2) and [4-PrRad][Ni(dmit)2] (3) where [Ni(dmit)2]- is an anionic pi-radical (dmit = 1,3-dithiol-2-thione-4,5-dithiolate) and [3-MeRad]+ is 3-N-methylpyridinium alpha-nitronyl nitroxide, [4-MeRad]+ is 4-N-methylpyridinium alpha-nitronyl nitroxide and [4-PrRad]+ is 4-N-propylpyridinium alpha-nitronyl nitroxide. The temperature-dependent magnetic susceptibility of 1 revealed that an antiferromagnetic interaction operates between the 3-MeRad+ radical cations with exchange coupling constants of J1 = - 1.72 cm-1 and antiferromagnetism assigned to the spin ladder chains of the Ni(dmit)2 radical anions. Compound 1 exhibits semiconducting behavior and 3 presents capacitor behavior in the temperature range studied (4 - 300 K).
Resumo:
In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distributionand also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. Morespecifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the customer-end voltage regulation problem, an observer-based control scheme is proposed. It is shown how different control system structures affect the performance. The performance meeting the requirements is achieved by using only one output measurement, when operating in a rigid network. Similar performance can be achieved in a weak grid by DC voltage measurement. An additional improvement can be achieved when an adaptive gain scheduling-based control is introduced. As a conclusion, the final power quality is determined by a sum of various factors, and the thesis provides the guidelines for designing the system that improves the power quality experienced by the customer.
Resumo:
RESUMO O objetivo deste estudo foi determinar a relação entre constante dielétrica e teor de umidade de seis espécies de madeira, por meio da construção de um capacitor. O material utilizado constituiu-se de madeiras da Amazônia não comercializadas, mas com alta abundância e dominância na Floresta Nacional deAlbizia duckeana (fava-paricá), Brosimumsp. (amapá-doce), Chamaecrista scleroxylon (pau-santo),Qualea dinizii (mandioqueira-rosa), Trattinnickia burserifolia (amescla) e Swartzia laurifolia(gombeira). Os corpos de prova para determinação da constante dielétrica foram confeccionados com as dimensões de 4,5 x 4,5 x 1 cm, definidas por testes preliminares realizados no Laboratório de Produtos Florestais (LPF). Para a coleta dos valores de capacitância, foi também construído um capacitor, utilizando multímetro digital, fios de cobre e placas de alumínio, sendo as medições realizadas em oito ocasiões, com intervalos de 1 h cada, durante o processo de secagem, que se iniciou na condição de massa saturada até atingir massa constante. A partir dos dados, foram ajustadas as curvas de regressão entre os valores de teor de umidade e constante dielétrica da madeira, as quais apresentaram forte correlação com as duas variáveis, mostrando a influência direta e proporcional do teor de umidade sobre a constante dielétrica. Em razão da inexistência de relação direta entre os dados de massa específica e constante dielétrica das espécies estudadas, sugere-se o desenvolvimento de novos estudos para melhor explicar a relação entre essas duas grandezas.
Resumo:
The irrigation is a technique developed to supply the hydric needs of the plants. The use of the water should be optimized so that the culture just has enough for its growth, avoiding waste. The objective of this work was to characterize the behavior of capacitive sensors of humidity to monitor the moisture in the soils. In first instance, it was appraised sensors with dielectric built of synthetic pomes stone (Rd = 0,4 and Rd = 0,8) and of soil samples (Rd = 0,8 and Rd = 1,0), being the Rd parameter a geometric factor that relates the distance between the capacitor plates with radius of the plates. For the calibration, the sensors were installed in PVC recipient of cylindrical shape, filled with soil. The set (sensor and soil) was humidified by capillary effect and submitted by a natural drying very slowly. The parameter readings were taken daily, which allowed obtain the curves relating the humidity percentage, expressed in terms of dry weight, with the output voltage fort the sensor. The experiments were performed in sand soil and in dark red latossolo. The obtained results allowed to infer that the behavior of the sensor has a specific feature for each type of soil, being, therefore, necessary to develop a own calibration curve for the sensor, when used in soil with specific characteristic.
Resumo:
In the doctoral dissertation, low-voltage direct current (LVDC) distribution system stability, supply security and power quality are evaluated by computational modelling and measurements on an LVDC research platform. Computational models for the LVDC network analysis are developed. Time-domain simulation models are implemented in the time-domain simulation environment PSCAD/EMTDC. The PSCAD/EMTDC models of the LVDC network are applied to the transient behaviour and power quality studies. The LVDC network power loss model is developed in a MATLAB environment and is capable of fast estimation of the network and component power losses. The model integrates analytical equations that describe the power loss mechanism of the network components with power flow calculations. For an LVDC network research platform, a monitoring and control software solution is developed. The solution is used to deliver measurement data for verification of the developed models and analysis of the modelling results. In the work, the power loss mechanism of the LVDC network components and its main dependencies are described. Energy loss distribution of the LVDC network components is presented. Power quality measurements and current spectra are provided and harmonic pollution on the DC network is analysed. The transient behaviour of the network is verified through time-domain simulations. DC capacitor guidelines for an LVDC power distribution network are introduced. The power loss analysis results show that one of the main optimisation targets for an LVDC power distribution network should be reduction of the no-load losses and efficiency improvement of converters at partial loads. Low-frequency spectra of the network voltages and currents are shown, and harmonic propagation is analysed. Power quality in the LVDC network point of common coupling (PCC) is discussed. Power quality standard requirements are shown to be met by the LVDC network. The network behaviour during transients is analysed by time-domain simulations. The network is shown to be transient stable during large-scale disturbances. Measurement results on the LVDC research platform proving this are presented in the work.
Resumo:
Superkondensaattorit paikkaavat perinteisten kondensaattorien ja akkujen väliin jäävää teho- sekä energiasuorituskyvyn kuilua sähköenergian varastoinnissa. Tässä kandidaatin-työssä selvitetään superkondensaattorien toimintaperiaate, sähköiset ominaisuudet sekä saatavilla olevien kaupallisten tuotteiden suorituskyky.