922 resultados para Buildings, Prefabricated


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This leaflet, no. 7, by Grant C. Miller, of Patton & Miller Architects in Chicago, contains information on how to plan the erection of a new library building. It discusses how to select a librarian, architect, location and surroundings design and layout needed to best serve the library users.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In coordination with a Technical Advisory Committee (TAC) consisting of County Engineers and Iowa DOT representatives, the Iowa DOT has proposed to develop a set of standards for a single span prefabricated bridge system for use on the local road system. The purpose of the bridge system is to improve bridge construction, accelerate project delivery, improve worker safety, be cost effective, reduce impacts to the travelling public by reducing traffic disruptions and the duration of detours, and allow local forces to construct the bridges. HDR Inc. was selected by the Iowa DOT to perform the initial concept screening of the bridge system. This Final Report summarizes the initial conceptual effort to investigate potential systems, make recommendations for a preferred system and propose initial details to be tested in the laboratory in Phase 2 of the project. The prefabricated bridge components were to be based on the following preliminary criteria set forth by the TAC. The criteria were to be verified and/ or modified as part of the conceptual development. - 24’ and 30’ roadway widths - Skews of 0o, 15o, and 30o - Span lengths of 30’ – 70’ in 10’ increments using precast concrete beams - Voided box beams could be considered - Limit precast element weight to 45,000 pounds for movement and placement of beams - Beams could be joined transversely with threaded rods - Abutment concepts may included precast as well as an option for cast-in-place abutments with pile foundations In addition to the above criteria, there was an interest to use a single-width prefabricated bridge component to simplify fabrication as well as a desire to utilize non-prestressed concrete systems where possible to allow for precasting of the beam modules by local forces or local precast plants. The SL-1 modular steel bridge rail was identified for use with this single span prefabricated bridge system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This leaflet talks about the architecture of library buildings. It provides information on the selection of an architect and how to design flooring and room arrangements in a practical way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Courtyard houses are attested at several sites in southern Gaul between the 5th and the 1st centuries BC. They represent a new concept when compared to the traditional protohistoric houses of the region and have often been interpreted in terms of Mediterranean, Greek or Italic influences. Regardless of their origin, exogenous influences or evolution, these houses suggest the emergence of social differentiation and elites in several of the main settlements. This article analyses the significance of the various courtyard house categories in the context of local, indigenous societies, while trying to understand the social implications of this new type of residence. In a wider context, the development of domestic architecture during the Iron Age is analysed alongside the relationships between changing uses of space and social changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In animal farming, respiratory disease has been associated with indoor air contaminants and an excess in FEV1 decline. Our aim was to determine the characteristics and risk factors for chronic obstructive pulmonary disease (COPD) in never-smoking European farmers working inside animal confinement buildings. METHODS: A sample of participants in the European Farmers' Study was selected for a cross-sectional study assessing lung function and air contaminants. Dose-response relationships were assessed using logistic regression models. RESULTS: COPD was found in 18 of 105 farmers (45.1 SD 11.7 years) (17.1%); 8 cases (7.6%) with moderate and 3 cases (2.9%) with severe disease. Dust and endotoxin showed a dose-response relationship with COPD, with the highest prevalence of COPD in subjects with high dust (low=7.9%/high=31.6%) and endotoxin exposure (low=10.5%/high=20.0%). This association was statistically significant for dust in the multivariate analysis (OR 6.60, 95% CI 1.10-39.54). CONCLUSION: COPD in never-smoking animal farmers working inside confinement buildings is related to indoor dust exposure and may become severe. [Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Environmental conditions play a crucial role in mite growth, and optimal environmental control is key in the prevention of airway inflammation in chronic allergic rhinoconjunctivitis or asthma. OBJECTIVE: To evaluate the relationship between building energy performance and indoor mite allergen concentration in a cross-sectional study. METHODS: Major allergen concentration (Der f 1, Der p 1, mite group 2, Fel d 1 and Bla g 2) was determined by quantitative dot blot analysis from mattress and carpet dust samples in five buildings designed for low energy use (LEB) and in six control buildings (CB). Inhabitants had received 4 weeks prior to mite measurement a personal validated questionnaire related to the perceived state of health and comfort of living. RESULTS: Cumulative mite allergen concentration (with Der f 1 as the major contributor) was significantly lower in LEB as compared with CB both in mattresses and in carpets. In contrast, the two categories of buildings did not differ in Bla g 2 and Fel d 1 concentration, in the amount of dust and airborne mould collected. Whereas temperature was higher in LEB, relative humidity was significantly lower than in CB. Perceived overall comfort was better in LEB. CONCLUSIONS: Major mite allergen Der f 1 preferentially accumulates in buildings not specifically designed for low energy use, reaching levels at risk for sensitization. We hypothesize that controlled mechanical ventilation present in all audited LEB may favour lower air humidity and hence lower mite growth and allergen concentration, while preserving optimal perceived comfort.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A partir de maig de 2003, per iniciativa del Vicerectorat adjunt d’Edificacions de la UPC, el Centre Interdisciplinari de Tecnologia, Innovació i Educació per a la Sostenibilitat (CITIES) treballa en l’elaboració i la implantació del Pla d’Eficiència en el Consum de Recursos (PECR), amb l’objectiu d’establir polítiques i definir línees d’actuació per a l’estalvi i l’eficiència en el consum dels recursos energètics i d’ aigua en els edificis de la UPC.El PECR contempla, en una de les primeres fases, la realització d’avaluacions energètiques en les edificacions de la UPC per valorar l’estat actual dels edificis i poder establir uns indicadors del seu comportament energètic a partir dels quals establir els objectius d’estalvi i d’eficiència. Per fer aquestes avaluacions, es va crear una línea de projectes finals de carrera (PFC) per a estudiants de l’Escola Politècnica Superior de l’Edificació de Barcelona (EPSEB), sota la coordinació de professors tutors de diferents departaments y amb la col•laboració indispensable de totes les unitats de recolzament de la UPC.Aquesta publicació és la ponència presentada al IV Congrès "Sustainable City", a Tallinn, en el que es va presentar aquest projecte com a una eina de treball amb l'objectiu de reduir l'impacte ambiental dels edificis universitaris en les ciutats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universities must motivate future professionals so that they are able to apply their experience over and beyond the scientific and technological context. These professionals should also be trained so that they are aware of the current position as regards the economy and limited energy resources, and they must be creative, knowledgeable and committed if they are to rethink the current model.The Departments of Architectural Technology II and Applied Physics, in collaboration with the Interdisciplinary Centre of Technology, Innovation and Education for Sustainability (CITIES), believed that students could be given the opportunity to specialise in the area of sustainable development by means of their final theses [2]. With this objective in mind, a line of theses called Energy Assessments was created as part of the Plan for Resource Consumption Efficiency (PECR). The line was based on a learning strategy that focused on the student.The teaching staff was able to observe that, in terms of cognitive aspects, the students improved their knowledge of environmental issues and the associated skills, and that they were more able to solve problems in the area of sustainability and had greater concerns about this subject matter after having completed their theses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postprint (author’s final draft)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this master’s thesis was to develop a method to be used in the selection of an optimal energy system for buildings and districts. The term optimal energy system was defined as the energy system which best fulfils the requirements of the stakeholder on whose preferences the energy systems are evaluated. The most influential stakeholder in the process of selecting an energy system was considered to be the district developer. The selection method consisted of several steps: Definition of the district, calculating the energy consumption of the district and buildings within the district, defining suitable energy system alternatives for the district, definition of the comparing criteria, calculating the parameters of the comparing criteria for each energy system alternative and finally using a multi-criteria decision method to rank the alternatives. For the purposes of the selection method, the factors affecting the energy consumption of buildings and districts and technologies enabling the use of renewable energy were reviewed. The key element of the selection method was a multi-criteria decision making method, PROMETHEE II. In order to compare the energy system alternatives with the developed method, the comparing criteria were defined in the study. The criteria included costs, environmental impacts and technological and technical characteristics of the energy systems. Each criterion was given an importance, based on a questionnaire which was sent for the steering groups of two district development projects. The selection method was applied in two case study analyses. The results indicate that the selection method provides a viable and easy way to provide the decision makers alternatives and recommendations regarding the selection of an energy system. Since the comparison is carried out by changing the alternatives into numeric form, the presented selection method was found to exclude any unjustified preferences over certain energy systems alternatives which would affect the selection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this thesis was to evaluate the short- and long-term effectiveness of a prefabricated occlusal appliance (R) on patients with myofascial pain and headache by comparing it with the treatment of the stabilization appliance (S). Another aim was to evaluate the effect of appliance treatment on stress-related salivary parameters like cortisol and IgA, as well as on flow rate values in these patients. Sixty-five patients diagnosed with myofascial temporomandibular disorder (TMD) pain, of whom 94% suffered concomitantly from headache, at two centres for Stomatognathic Physiology, one in Sweden and one in Finland, were included in this randomized controlled trial using Research Diagnostic Criteria for TMD (RDC/TMD), with history questionnaires and clinical examinations performed at baseline and at 6- and 10-weeks, and 6- and 12-month follow-ups. Patients were randomly assigned either to the R or the S group. Treatment outcome was measured according to IMMPACT (Initiative on Methods, Measurements, and Pain Assessment in Clinical Trials), i.e. four chronic pain outcome domains: pain intensity, overall improvement, physical and emotional functioning. Changes in frequency and intensity of headache were recorded. Thirty-nine patients participated in the saliva study. Salivary analyses were performed at 6 and 10 weeks. The results revealed no differences between groups at baseline. At all follow-ups, all four outcome measures, as well as frequency and intensity of headache, showed statistically significant within-group improvement compared to baseline, without significant differences between groups. No treatment-induced changes in saliva parameters could be registered. In conclusion, the effectiveness of the prefabricated appliance seemed to be similar to that of the stabilization appliance in alleviating myofascial pain, and frequency and intensity of headache, in the short as well as the long term. However, no changes in salivary parameters were observed during treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a Petri Net approach is introduced for modelling and simulation of control strategies in Intelligent Building. In this context, it is claimed that integration with other building systems can be achieved in a more systematic way considering a mechatronic approach (i.e. multidisciplinary concepts applied to the development of systems). The case study is the Ambulatory Building of Medical School Hospital of University of São Paulo. Particularly, the developed methodology is applied to the elevator system and to the HVAC (Heating, Ventilation and Air Conditioning) system. It is shown that using this approach, the control systems could be integrated, improving performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dans ma mémoire, j’ai discuté les concepts d’arbitrage comme méthode de résolution d’un litige et par après, je donne un court historique de l’acceptation d’arbitrage au Québec. Le Chapitre I étudie la structure des règlements du R.B.Q., qui est un gendre d’arbitrage obligatoire institutionnelle, et j’inclus les diverses procédures dans ce système d’arbitrage. La sécurité offert par le plan de garantie règle par le R.B.Q. est discuté dans le Chapitre II en autant qu’il est relié avec le system d’arbitrage R.B.Q., y compris la structure du plan et le contenu de la sécurité. Chapitre III parle des recours disponible aux Bénéficiares ainsi que les avantages et désavantages de l’arbitrage sous les Règlements du R.B.Q. Un court étude comparative de quatre autres juridictions est recherché en Chapitre IV, incluant notre voisin, Ontario, les Etats-Unis et on croise dans les juridictions de Royaume Unie et Allemagne. En conclusion, j’établis que notre système d’arbitrage sous le Règlement protéges notre publique plus que d’autres juridictions. Je suggère des améliorations au système, par contre, incluant l’agrandissement du plan de garantie, l’ajout des pouvoirs donnés aux arbitres américains et ensuite d’intègré un système d’arrêt semblable aux Royaumes Unis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cette thèse contribue à l'état actuel des connaissances sur la compatibilité des nouveaux bâtiments avec les environnements urbains historiques. Elle suit un mode de présentation classique: Introduction, Revue de Littérature, Méthodologie, Résultats, Discussion et Conclusion. Le problème étudié est le manque d'orientation pour intégrer les processus de développement et de sauvegarde dans les contextes établis. La littérature récente révèle que les règles de préservation, aussi appelées normes et lignes directrices, ne peuvent pas garantir une relation compatible entre une intervention et son milieu. La pensée contemporaine dans le domaine de la conservation et de la gestion du patrimoine invite donc l’exploration d'autres moyens pour lier la nouvelle architecture à l'ancienne. Ainsi, le présent projet de recherche explore une approche alternative aux règles de préservation en vue d’atteindre le but de nouveaux bâtiments compatibles et d’améliorer la prise de décision fondée sur les valeurs. Pour produire des résultats spécifiques et convaincants, un cas a été sélectionné. Celui-ci est une ville dans la région du Golfe Arabe : la Ville de Koweït. Le résultat principal est le développement d’une approche, mise en œuvre en posant des questions approfondies sur le lieu, la conception et la construction des nouveaux bâtiments. Les questions suggérées dans la thèse mettent l’accent sur les valeurs patrimoniales et les choix de conception afin de permettre un changement réfléchi au sein des environnements urbains historiques. Elles aident aussi à évaluer les nouvelles propositions de projets au cas par cas. Pour démontrer comment cette approche pourrait être présentée et utilisée par les requérants et les évaluateurs, un modèle théorique est proposé. Ce modèle a ensuite été discuté avec des professionnels locaux et internationaux qui ont identifié ses forces et ses limites. En conclusion, l’ensemble des résultats montre que la mise à disposition de règles et / ou de questions approfondies n’est pas une solution satisfaisante puisqu’il y a d'autres enjeux importants qui devraient être abordés: comment appliquer l'orientation efficacement une fois qu’elle a été créée, comment développer la compétence liée à la prise de décision fondée sur les valeurs et comment insérer la conservation du patrimoine dans la mentalité du gouvernement local et des communautés. Lorsque ces enjeux seront traités, le patrimoine pourra devenir partie intégrante du processus de planification, ce qui est le but ultime. Enfin, cinq axes de recherche sont recommandés pour poursuivre l’exploration des idées introduites dans cette étude.