984 resultados para Arms control.


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper seeks to delineate some preliminary factors and working methods that could work in favour of establishing a workable international export control regime for dual-use goods and technologies. Drawing on the work initiated by various United Nations initiatives and the Wassenaar Agreement, but specifically looking at the European Union export regime model, this working paper asks if and how a similar model could be adopted at the international level. Far from suggesting that the EU regime should of could be adopted on a global basis or that the regime is full-proof, the authors acknowledge that EU regulations are seen as among the most stringent of frameworks on dual-use goods and technologies available. Accordingly, this paper asks what elements of the EU’s control regime could be of international benefit after the ATT negotiations and how it could be adopted on a more international basis. Indeed, any future ATT control mechanism for dual-use items will have to draw on existing arms transfers and control regimes. It does this through an analysis of the ATT and the current discourse on dual-use goods and technologies in the negotiations, an stocktaking of the strengths and weaknesses of the EU’s export control regime and by asking what elements of the EU’s regime could be utilised for international control mechanisms after a future ATT is negotiated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims & Rationale/Objectives: With the knowledge that overweight is a major public health concern in Australia, that a multidisciplinary team approach to the management of lifestyle-related conditions is supported, and that the Australian Government recently recognised the role of the exercise physiologist (EP) in reducing the health burden of disease by their inclusion for reimbursement under the Medicare Plus scheme, this study sought to undertake a pilot RCT to compare GP and EP interventions to reduce primary cardiovascular risk in the overweight general practice population. Methods and Measures: Overweight patients recruited by a convenience sample of GPs were randomised into one of three arms: the control group, or the GP or EP intervention group (in which patients received either five GP or five EP consultations over 24 weeks). Patients had baseline, 12- and 24-week measures of body composition and cardio-respiratory fitness, and completed baseline and end-of-study surveys, fasting lipids and glucose. GPs and EPs completed an end-of-study survey. Results:Sixty-seven patients attended the baseline assessment. Overall retention rate was 67%. Patients were generally satisfied with the effectiveness of the interventions and their weight reduction. Favourable trends in BMI, weight, glucose and exercise levels for GP and EP intervention groups and in physical activity levels for all groups Conclusions: This study supports the feasibility of a RCT of GP and EP interventions for decreasing primary cardiovascular risk in the overweight general practice population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Shaft-mounted gearboxes are widely used in industry. The torque arm that holds the reactive torque on the housing of the gearbox, if properly positioned creates the reactive force that lifts the gearbox and unloads the bearings of the output shaft. The shortcoming of these torque arms is that if the gearbox is reversed the direction of the reactive force on the torque arm changes to opposite and added to the weight of the gearbox overloads the bearings shortening their operating life. In this paper, a new patented design of torque arms that develop a controlled lifting force and counteract the weight of the gearbox regardless of the direction of the output shaft rotation is described. Several mathematical models of the conventional and new torque arms were developed and verified experimentally on a specially built test rig that enables modelling of the radial compliance of the gearbox bearings and elastic elements of the torque arms. Comparison showed a good agreement between theoretical and experimental results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim To test the efficacy of Medilixir [cream] against the standard treatment of aqueous cream in the provision of relief from the symptoms of postburn itch. Design RCT with two parallel arms. Setting Professor Stuart Pegg Adult Burns Centre, Royal Brisbane and Women's Hospital, Brisbane, Australia. Participants Fifty-two patients aged between 18 and 80 years, admitted directly to the burns centre between 10 March and 22 July 2008, were able to provide informed consent, and had shown no allergic reaction to a patch test with the study medication, were randomised. Patients admitted from intensive care or high dependency were excluded. Main results Effect estimates and confidence intervals were not reported for any of the outcomes; only group means/proportions and P-values from hypothesis testing were provided. More patients in the intervention group reported itch reduction compared to comparison treatment (91 vs. 82%, P=0.001). Itch recurrence after cream application occurred later in the intervention group compared to the control group (P<0.001). Use of antipruritic medication was significantly greater in the control group (P=0.023). There was no difference in sleep disturbance between groups (not quantified). On average, Medilixir took longer to apply than aqueous cream (157s for Medilixir vs. 139s for aqueous cream; mean difference 17s), but authors noted that the groups did not differ significantly (CI for mean difference and P-values were not reported).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A large range of underground mining equipment makes use of compliant hydraulic arms for tasks such as rock-bolting, rock breaking, explosive charging and shotcreting. This paper describes a laboratory model electo-hydraulic manipulator which is used to prototype novel control and sensing techniques. The research is aimed at improving the safety and productivity of these mining tasks through automation, in particular the application of closed-loop visual positioning of the machine's end-effector.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses some of the sensing technologies and control approaches available for guiding robot manipulators for a class of underground mining tasks including drilling jumbos, bolting arms, shotcreters or explosive chargers. Data acquired with such sensors, in the laboratory and underground, is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is ample evidence that humans are able to control the endpoint impedance of their arms in response to active destabilizing force fields. However, such fields are uncommon in daily life. Here, we examine whether the CNS selectively controls the endpoint impedance of the arm in the absence of active force fields but in the presence of instability arising from task geometry and signal-dependent noise (SDN) in the neuromuscular system. Subjects were required to generate forces, in two orthogonal directions, onto four differently curved rigid objects simulated by a robotic manipulandum. The endpoint stiffness of the limb was estimated for each object curvature. With increasing curvature, the endpoint stiffness increased mainly parallel to the object surface and to a lesser extent in the orthogonal direction. Therefore, the orientation of the stiffness ellipses did not orient to the direction of instability. Simulations showed that the observed stiffness geometries and their pattern of change with instability are the result of a tradeoff between maximizing the mechanical stability and minimizing the destabilizing effects of SDN. Therefore, it would have been suboptimal to align the stiffness ellipse in the direction of instability. The time course of the changes in stiffness geometry suggests that modulation takes place both within and across trials. Our results show that an increase in stiffness relative to the increase in noise can be sufficient to reduce kinematic variability, thereby allowing stiffness control to improve stability in natural tasks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates how the efficiency and robustness of a skilled rhythmic task compete against each other in the control of a bimanual movement. Human subjects juggled a puck in 2D through impacts with two metallic arms, requiring rhythmic bimanual actuation. The arms kinematics were only constrained by the position, velocity and time of impacts while the rest of the trajectory did not influence the movement of the puck. In order to expose the task robustness, we manipulated the task context in two distinct manners: the task tempo was assigned at four different values (hence manipulating the time available to plan and execute each impact movement individually); and vision was withdrawn during half of the trials (hence reducing the sensory inflows). We show that when the tempo was fast, the actuation was rhythmic (no pause in the trajectory) while at slow tempo, the actuation was discrete (with pause intervals between individual movements). Moreover, the withdrawal of visual information encouraged the rhythmic behavior at the four tested tempi. The discrete versus rhythmic behavior give different answers to the efficiency/robustness trade-off: discrete movements result in energy efficient movements, while rhythmic movements impact the puck with negative acceleration, a property preserving robustness. Moreover, we report that in all conditions the impact velocity of the arms was negatively correlated with the energy of the puck. This correlation tended to stabilize the task and was influenced by vision, revealing again different control strategies. In conclusion, this task involves different modes of control that balance efficiency and robustness, depending on the context. © 2008 Springer-Verlag.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper considers the feedback stabilization of periodic orbits in a planar juggler. The juggler is "blind," i.e, he has no other sensing capabilities than the detection of impact times. The robustness analysis of the proposed control suggests that the arms acceleration at impact is a crucial design parameter even though it plays no role in the stability analysis. Analytical results and convergence proofs are provided for a simplified model of the juggler. The control law is then adapted to a more accurate model and validated in an experimental setup. © 2007 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Based on the phase-conjugate polarization interference between two-pathway excitations, we obtained an analytic closed form for the second-order or fourth-order Markovian stochastic correlation of the V three-level sum-frequency polarization beat (SFPB) in attosecond scale. Novel interferometric oscillatory behavior is exposed in terms of radiation-radiation, radiation-matter, and matter-matter polarization beats. The phase-coherent control of the light beams in the SFPB is subtle. When the laser has broadband linewidth, the homodyne detected SFPB signal shows resonant-nonresonant cross correlation, a drastic difference for three Markovian stochastic fields, and the autocorrelation of the SFPB exhibits hybrid radiation-matter detuning terahertz damping oscillation. As an attosecond ultrafast modulation process, it can be extended intrinsically to any sum frequency of energy levels. It has been also found that the asymmetric behaviors of the polarization beat signals due to the unbalanced controllable dispersion effects between the two arms of interferometer do not affect the overall accuracy in case using the SFPB to measure the Doppler-free energy-level sum of two excited states.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article describes two neural network modules that form part of an emerging theory of how adaptive control of goal-directed sensory-motor skills is achieved by humans and other animals. The Vector-Integration-To-Endpoint (VITE) model suggests how synchronous multi-joint trajectories are generated and performed at variable speeds. The Factorization-of-LEngth-and-TEnsion (FLETE) model suggests how outflow movement commands from a VITE model may be performed at variable force levels without a loss of positional accuracy. The invariance of positional control under speed and force rescaling sheds new light upon a familiar strategy of motor skill development: Skill learning begins with performance at low speed and low limb compliance and proceeds to higher speeds and compliances. The VITE model helps to explain many neural and behavioral data about trajectory formation, including data about neural coding within the posterior parietal cortex, motor cortex, and globus pallidus, and behavioral properties such as Woodworth's Law, Fitts Law, peak acceleration as a function of movement amplitude and duration, isotonic arm movement properties before and after arm-deafferentation, central error correction properties of isometric contractions, motor priming without overt action, velocity amplification during target switching, velocity profile invariance across different movement distances, changes in velocity profile asymmetry across different movement durations, staggered onset times for controlling linear trajectories with synchronous offset times, changes in the ratio of maximum to average velocity during discrete versus serial movements, and shared properties of arm and speech articulator movements. The FLETE model provides new insights into how spina-muscular circuits process variable forces without a loss of positional control. These results explicate the size principle of motor neuron recruitment, descending co-contractive compliance signals, Renshaw cells, Ia interneurons, fast automatic reactive control by ascending feedback from muscle spindles, slow adaptive predictive control via cerebellar learning using muscle spindle error signals to train adaptive movement gains, fractured somatotopy in the opponent organization of cerebellar learning, adaptive compensation for variable moment-arms, and force feedback from Golgi tendon organs. More generally, the models provide a computational rationale for the use of nonspecific control signals in volitional control, or "acts of will", and of efference copies and opponent processing in both reactive and adaptive motor control tasks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A traffic control device in the form of a humanoid character robot, doll or dummy is used to warn driver of danger ahead on the road. The device can be used on roads, streets and in other sites where there are moving vehicles. The robotic device informs drivers of impending danger by moving its arms and sounding an acoustic alarm. In this way the robot can simulate a policeman or road flagging operator. The device may also include speed detection and preferably speed indication means. The robot may make decisions based on the detected speed of a vehicle and the limit for the area in operating the arms and sound warning means. The robot may also be equipped with a camera or video. The robot may also be controlled wirelessly.