990 resultados para Angiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to SNR constraints, current "bright-blood" 3D coronary MRA approaches still suffer from limited spatial resolution when compared to conventional x-ray coronary angiography. Recent 2D fast spin-echo black-blood techniques maximize signal for coronary MRA at no loss in image spatial resolution. This suggests that the extension of black-blood coronary MRA with a 3D imaging technique would allow for a further signal increase, which may be traded for an improved spatial resolution. Therefore, a dual-inversion 3D fast spin-echo imaging sequence and real-time navigator technology were combined for high-resolution free-breathing black-blood coronary MRA. In-plane image resolution below 400 microm was obtained. Magn Reson Med 45:206-211, 2001.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: Recent developments of magnetic resonance imaging enabled free-breathing coronary MRA (cMRA) using steady-state-free-precession (SSFP) for endogenous contrast. The purpose of this study was a systematic comparison of SSFP cMRA with standard T2-prepared gradient-echo and spiral cMRA. METHODS: Navigator-gated free-breathing T2-prepared SSFP-, T2-prepared gradient-echo- and T2-prepared spiral cMRA was performed in 18 healthy swine (45-68 kg body-weight). Image quality was investigated subjectively and signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and vessel sharpness were compared. RESULTS: SSFP cMRA allowed for high quality cMRA during free breathing with substantial improvements in SNR, CNR and vessel sharpness when compared with standard T2-prepared gradient-echo imaging. Spiral imaging demonstrated the highest SNR while image quality score and vessel definition was best for SSFP imaging. CONCLUSION: Navigator-gated free-breathing T2-prepared SSFP cMRA is a promising new imaging approach for high signal and high contrast imaging of the coronary arteries with improved vessel border definition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postmortem angiography is becoming increasingly essential in forensic pathology as an adjunct to conventional autopsy. Despite the numerous advantages of this technique, some questions have been raised regarding the influence of the contrast agent injected on the results of toxicological and biochemical analyses. The aim of this study was to investigate the effect of the injection of the contrast agent Angiofil®, mixed with paraffin oil, on the results of postmortem biochemical investigations performed on vitreous humor. Postmortem biochemical investigations were performed on vitreous samples collected from bodies that had undergone postmortem angiography (n=50) and from a control group (n=50). Two vitreous samples were analyzed for each group and the results compared. Glucose, urea, creatinine, 3-β-hydroxybutyrate, sodium and chloride were tested. Different values were observed between the first and second samples in each group. However, these differences were not clinically relevant, suggesting that the injection of this contrast agent mixture does not modify the concentration of the analyzed substances in the vitreous humor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To develop and evaluate a practical method for the quantification of signal-to-noise ratio (SNR) on coronary MR angiograms (MRA) acquired with parallel imaging.Materials and Methods: To quantify the spatially varying noise due to parallel imaging reconstruction, a new method has been implemented incorporating image data acquisition followed by a fast noise scan during which radio-frequency pulses, cardiac triggering and navigator gating are disabled. The performance of this method was evaluated in a phantom study where SNR measurements were compared with those of a reference standard (multiple repetitions). Subsequently, SNR of myocardium and posterior skeletal muscle was determined on in vivo human coronary MRA.Results: In a phantom, the SNR measured using the proposed method deviated less than 10.1% from the reference method for small geometry factors (<= 2). In vivo, the noise scan for a 10 min coronary MRA acquisition was acquired in 30 s. Higher signal and lower SNR, due to spatially varying noise, were found in myocardium compared with posterior skeletal muscle.Conclusion: SNR quantification based on a fast noise scan is a validated and easy-to-use method when applied to three-dimensional coronary MRA obtained with parallel imaging as long as the geometry factor remains low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of radial k-space sampling and water-selective excitation on a novel navigator-gated cardiac-triggered slab-selective inversion prepared 3D steady-state free-precession (SSFP) renal MR angiography (MRA) sequence was investigated. Renal MRA was performed on a 1.5-T MR system using three inversion prepared SSFP approaches: Cartesian (TR/TE: 5.7/2.8 ms, FA: 85 degrees), radial (TR/TE: 5.5/2.7 ms, FA: 85 degrees) SSFP, and radial SSFP combined with water-selective excitation (TR/TE: 9.9/4.9 ms, FA: 85 degrees). Radial data acquisition lead to significantly reduced motion artifacts (P < 0.05). SNR and CNR were best using Cartesian SSFP (P < 0.05). Vessel sharpness and vessel length were comparable in all sequences. The addition of a water-selective excitation could not improve image quality. In conclusion, radial k-space sampling reduces motion artifacts significantly in slab-selective inversion prepared renal MRA, while SNR and CNR are decreased. The addition of water-selective excitation could not improve the lower CNR in radial scanning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Objectif : Le but de ce travail est d`étudier l'angiographie par scanner multi-barrette (AS) dans l'évaluation de l'artériopathie oblitérante (AOMI) de l'aorte abdominale et des membres inférieurs utilisant une méthode adaptative d'acquisition pour optimiser le rehaussement artériel en particulier pour le lit artériel distal et les artères des pieds. Matériels et méthodes : Trente-quatre patients pressentant une AOMI ont bénéficié d'une angiographie trans-cathéter (ATC) et d'une AS dans un délai inférieur ou égal à 15 jours. L'AS a été effectuée du tronc coeliaque jusqu'aux artères des pieds en une seule acquisition utilisant une haute résolution spatiale (16x0.625 mm). La vitesse de table et le temps de rotation pour chaque examen ont été choisis selon le temps de transit du produit de contraste, obtenu après un bolus test. Une quantité totale de 130 ml de contraste à 4 ml/s a été utilisée. L'analyse des images de l'AS a été effectuée par deux observateurs et les données ATC ont été interprétées de manière indépendante par deux autres observateurs. L'analyse a inclus la qualité de l'image et la détection de sténose supérieure ou égale à 50 % par patient et par segment artériel. La sensibilité et la spécificité de l'AS ont été calculées en considérant l'ATC comme examen de référence. La variabilité Interobservateur a été mesurée au moyen d'une statistique de kappa. Résultas : L'ATC a été non-conclusive dans 0.7 % des segments, tandis que l'AS était conclusive dans tous les segments. Sur l'analyse par patient, la sensibilité et la spécificité totales pour détecter une sténose significative égale ou supérieure à 50 % étaient de 100 %. L'analyse par segment a montré des sensibilités et de spécificités variant respectivement de 91 à 100 % et de 81 à 100 %. L'analyse des artères distales des pieds a révélé une sensibilité de 100 % et une spécificité de 90 %. Conclusion : L'angiographie par CT multi-barrettes utilisant cette méthode adaptative d'acquisition améliore la qualité de l'image et fournit une technique non-invasive et fiable pour évaluer L'AOMI, y compris les artères distales des pieds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: An accurate, noninvasive technique for the diagnosis of coronary disease would be an important advance. We investigated the accuracy of coronary magnetic resonance angiography among patients with suspected coronary disease in a prospective, multicenter study. METHODS: Coronary magnetic resonance angiography was performed during free breathing in 109 patients before elective x-ray coronary angiography, and the results of the two diagnostic procedures were compared. RESULTS: A total of 636 of 759 proximal and middle segments of coronary arteries (84 percent) were interpretable on magnetic resonance angiography. In these segments, 78 (83 percent) of 94 clinically significant lesions (those with a > or = 50 percent reduction in diameter on x-ray angiography) were also detected by magnetic resonance angiography. Overall, coronary magnetic resonance angiography had an accuracy of 72 percent (95 percent confidence interval, 63 to 81 percent) in diagnosing coronary artery disease. The sensitivity, specificity, and accuracy for patients with disease of the left main coronary artery or three-vessel disease were 100 percent (95 percent confidence interval, 97 to 100 percent), 85 percent (95 percent confidence interval, 78 to 92 percent), and 87 percent (95 percent confidence interval, 81 to 93 percent), respectively. The negative predictive values for any coronary artery disease and for left main artery or three-vessel disease were 81 percent (95 percent confidence interval, 73 to 89 percent) and 100 percent (95 percent confidence interval, 97 to 100 percent), respectively. CONCLUSIONS: Among patients referred for their first x-ray coronary angiogram, three-dimensional coronary magnetic resonance angiography allows for the accurate detection of coronary artery disease of the proximal and middle segments. This noninvasive approach reliably identifies (or rules out) left main coronary artery or three-vessel disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Postmortem investigations are becoming more and more sophisticated. CT and MRI are already being used in pathology and forensic medicine. In this context, the impact of postmortem angiography increases because of the rapid evaluation of organ-specific vascular patterns, vascular alteration under pathologic and physiologic conditions, and tissue changes induced by artificial and unnatural causes. CONCLUSION: In this article, the advantages and disadvantages of former and current techniques and contrast agents are reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary magnetic resonance angiography (MRA) is a powerful noninvasive technique with high soft-tissue contrast for the visualization of the coronary anatomy without X-ray exposure. Due to the small dimensions and tortuous nature of the coronary arteries, a high spatial resolution and sufficient volumetric coverage have to be obtained. However, this necessitates scanning times that are typically much longer than one cardiac cycle. By collecting image data during multiple RR intervals, one can successfully acquire coronary MR angiograms. However, constant cardiac contraction and relaxation, as well as respiratory motion, adversely affect image quality. Therefore, sophisticated motion-compensation strategies are needed. Furthermore, a high contrast between the coronary arteries and the surrounding tissue is mandatory. In the present article, challenges and solutions of coronary imaging are discussed, and results obtained in both healthy and diseased states are reviewed. This includes preliminary data obtained with state-of-the-art techniques such as steady-state free precession (SSFP), whole-heart imaging, intravascular contrast agents, coronary vessel wall imaging, and high-field imaging. Simultaneously, the utility of electron beam computed tomography (EBCT) and multidetector computed tomography (MDCT) for the visualization of the coronary arteries is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To objectively compare quantitative parameters related to image quality attained at coronary magnetic resonance (MR) angiography of the right coronary artery (RCA) performed at 7 T and 3 T. MATERIALS AND METHODS: Institutional review board approval was obtained, and volunteers provided signed informed consent. Ten healthy adult volunteers (mean age ± standard deviation, 25 years ± 4; seven men, three women) underwent navigator-gated three-dimensional MR angiography of the RCA at 7 T and 3 T. For 7 T, a custom-built quadrature radiofrequency transmit-receive surface coil was used. At 3 T, a commercial body radiofrequency transmit coil and a cardiac coil array for signal reception were used. Segmented k-space gradient-echo imaging with spectrally selective adiabatic fat suppression was performed, and imaging parameters were similar at both field strengths. Contrast-to-noise ratio between blood and epicardial fat; signal-to-noise ratio of the blood pool; RCA vessel sharpness, diameter, and length; and navigator efficiency were quantified at both field strengths and compared by using a Mann-Whitney U test. RESULTS: The contrast-to-noise ratio between blood and epicardial fat was significantly improved at 7 T when compared with that at 3 T (87 ± 34 versus 52 ± 13; P = .01). Signal-to-noise ratio of the blood pool was increased at 7 T (109 ± 47 versus 67 ± 19; P = .02). Vessel sharpness obtained at 7 T was also higher (58% ± 9 versus 50% ± 5; P = .04). At the same time, RCA vessel diameter and length and navigator efficiency showed no significant field strength-dependent difference. CONCLUSION: In our quantitative and qualitative study comparing in vivo human imaging of the RCA at 7 T and 3 T in young healthy volunteers, parameters related to image quality attained at 7 T equal or surpass those from 3 T.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: According to guidelines, patients with coronary artery disease (CAD) should undergo revascularization if myocardial ischemia is present. While coronary angiography (CXA) allows the morphological assessment of CAD, the fractional flow reserve (FFR) has proved to be a complementary invasive test to assess the functional significance of CAD, i.e. to detect ischemia. Perfusion Cardiac Magnetic Resonance (CMR) has turned out to be a robust non-invasive technique to assess myocardial ischemia. The objective: is to compare the cost-effectiveness ratio - defined as the costs per patient correctly diagnosed - of two algorithms used to diagnose hemodynamically significant CAD in relation to the pretest likelihood of CAD: 1) aCMRto assess ischemia before referring positive patients to CXA (CMR + CXA), 2) a CXA in all patients combined with a FFR test in patients with angiographically positive stenoses (CXA + FFR). Methods: The costs, evaluated from the health care system perspective in the Swiss, German, the United Kingdom (UK) and the United States (US) contexts, included public prices of the different tests considered as outpatient procedures, complications' costs and costs induced by diagnosis errors (false negative). The effectiveness criterion wasthe ability to accurately identify apatient with significantCAD.Test performancesused in the model were based on the clinical literature. Using a mathematical model, we compared the cost-effectiveness ratio for both algorithms for hypothetical patient cohorts with different pretest likelihood of CAD. Results: The cost-effectiveness ratio decreased hyperbolically with increasing pretest likelihood of CAD for both strategies. CMR + CXA and CXA + FFR were equally costeffective at a pretest likelihood of CAD of 62% in Switzerland, 67% in Germany, 83% in the UK and 84% in the US with costs of CHF 5'794, Euros 1'472, £ 2'685 and $ 2'126 per patient correctly diagnosed. Below these thresholds, CMR + CXA showed lower costs per patient correctly diagnosed than CXA + FFR. Implications for the health care system/professionals/patients/society These results facilitate decision making for the clinical use of new generations of imaging procedures to detect ischemia. They show to what extent the cost-effectiveness to diagnose CAD depends on the prevalence of the disease.