928 resultados para Analytical Ultracentrifugation
Resumo:
For a two layered long wave propagation, linearized governing equations, which were derived earlier from the Euler equations of mass and momentum assuming negligible friction and interfacial mixing are solved analytically using Fourier transform. For the solution, variations of upper layer water level is assumed to be sinosoidal having known amplitude and variations of interface level is solved. As the governing equations are too complex to solve it analytically, density of upper layer fluid is assumed as very close to the density of lower layer fluid to simplify the lower layer equation. A numerical model is developed using the staggered leap-forg scheme for computation of water level and discharge in one dimensional propagation having known amplitude for the variations of upper layer water level and interface level to be solved. For the numerical model, water levels (upper layer and interface) at both the boundaries are assumed to be known from analytical solution. Results of numerical model are verified by comparing with the analytical solutions for different time period. Good agreements between analytical solution and numerical model are found for the stated boundary condition. The reliability of the developed numerical model is discussed, using it for different a (ratio of density of fluid in the upper layer to that in the lower layer) and p (ratio of water depth in the lower layer to that in the upper layer) values. It is found that as ‘CX’ increases amplification of interface also increases for same upper layer amplitude. Again for a constant lower layer depth, as ‘p’ increases amplification of interface. also increases for same upper layer amplitude.
Resumo:
A method is described whereby sedimentation velocity is combined with equilibrium dialysis to determine the net charge (valence) of a protein by using chromate as an indicator ion for assessing the extent of the Donnan redistribution of small ions. The procedure has been used in experiments on bovine serum albumin under slightly alkaline conditions (pH 8.0, I 0.05) to illustrate its application to a system in which the indicator ion and protein both bear net negative charge and on lysozyme under slightly acidic conditions (pH 5.0, I 0.10) to illustrate the situation where chromate is a counterion. (C) 2001 Elsevier Science.
Resumo:
Renal drug elimination is determined by glomerular filtration, tubular secretion, and tubular reabsorption. Changes in the integrity of these processes influence renal drug clearance, and these changes may not be detected by conventional measures of renal function such as creatinine clearance. The aim of the current study was to examine the analytic issues needed to develop a cocktail of marker drugs (fluconazole, rac-pindolol, para-aminohippuric acid, sinistrin) to measure simultaneously the mechanisms contributing to renal clearance. High-performance liquid chromatographic methods of analysis for fluconazole, pindolol, para-aminohippuric acid, and creatinine and an enzymatic assay for sinistrin were developed or modified and then validated to allow determination of each of the compounds in both plasma and urine in the presence of all other marker drugs. A pilot clinical study in one volunteer was conducted to ensure that the assays were suitable for quantitating all the marker drugs to the sensitivity and specificity needed to allow accurate determination of individual renal clearances. The performance of all assays (plasma and urine) complied with published validation criteria. All standard curves displayed linearity over the concentration ranges required, with coefficients of correlation greater than 0.99. The precision of the interday and intraday variabilities of quality controls for each marker in plasma and urine were all less than 11.9% for each marker. Recoveries of markers (and internal standards) in plasma and urine were all at least 90%. All markers investigated were shown to be stable when plasma or urine was frozen and thawed. For all the assays developed, there were no interferences from other markers or endogenous substances. In a pilot clinical study, concentrations of all markers could be accurately and reproducibly determined for a sufficient duration of time after administration to calculate accurate renal clearance for each marker. This article presents details of the analytic techniques developed for measuring concentrations of marker drugs for different renal elimination processes administered as a single dose to define the processes contributing to renal drug elimination.
Resumo:
A semi-analytical analysis of free vibration of plates with cross-sectional discontinuities due to abrupt changes in thickness is presented. A basic square element divided into suitable subdomains dependent upon the positions of these abrupt changes is used as the basic building element, Admissible functions that satisfy the essential or geometric boundary conditions are used to define the transverse deflection of each subdomain. Continuities in the displacement, slope, moment and higher derivatives between adjacent subdomains are enforced at the interconnecting edges. The resulting global energy functional from the proper assembly of the coupled strain and kinetic energy contributions of each subdomain is then minimized via the Ritz procedure to extract the frequencies and mode shapes. Contour plots of a range of new mode shapes are presented for the enhancement of understanding the dynamic behavior of this class of plates, (C) 2001 Elsevier Science Ltd, All rights reserved.
Resumo:
Laser heating Ar-40/Ar-39 geochronology provides high analytical precision and accuracy, mum-scale spatial resolution. and statistically significant data sets for the study of geological and planetary processes, A newly commissioned Ar-40/Ar-39 laboratory at CPGeo/USP, Sao Paulo, Brazil, equips the Brazilian scientific community with a new powerful tool applicable to the study of geological and cosmochemical processes. Detailed information about laboratory layout, environmental conditions, and instrumentation provides the necessary parameters for the evaluation of the CPGeo/USp Ar-40/Ar-39 suitability to a diverse range of applications. Details about analytical procedures, including mineral separation, irradiation at the IPEN/CNEN reactor at USP, and mass spectrometric analysis enable potential researchers to design the necessary sampling and sample preparation program suitable to the objectives of their study. Finally, the results of calibration tests using Ca and K salts and glasses, international mineral standards, and in-house mineral standards show that the accuracy and precision obtained at the Ar-40/Ar-39 laboratory at CPGeo/USP are comparable to results obtained in the most respected laboratories internationally. The extensive calibration and standardization procedures under-taken ensure that the results of analytical studies carried out in our laboratories will gain immediate international credibility, enabling Brazilian students and scientists to conduct forefront research in earth and planetary sciences.
Resumo:
Quantification of calcium in the cuticle of the fly larva Exeretonevra angustifrons was undertaken at the micron scale using wavelength dispersive X-ray microanalysis, analytical standards, and a full matrix correction. Calcium and phosphorus were found to be present in the exoskeleton in a ratio that indicates amorphous calcium phosphate. This was confirmed through electron diffraction of the calcium-containing tissue. Due to the pragmatic difficulties of measuring light elements, it is not uncommon in the field of entomology to neglect the use of matrix corrections when performing microanalysis of bulk insect specimens. To determine, firstly, whether such a strategy affects the outcome and secondly, which matrix correction is preferable, phi-rho (z) and ZAF matrix corrections were contrasted with each other and without matrix correction. The best estimate of the mineral phase was found to be given by using the phi-rho (z) correction. When no correction was made, the ratio of Ca to P fell outside the range for amorphous calcium phosphate, possibly leading to flawed interpretation of the mineral form when used on its own.
Resumo:
This review summarizes the development of exclusion chromatography, also termed gel filtration, molecular-sieve chromatography and gel permeation chromatography, for the quantitative characterization of solutes and solute interactions. As well as affording a means of determining molecular mass and molecular mass distribution, the technique offers a convenient way of characterizing solute selfassociation and solute-ligand interactions in terms of reaction stoichiometry and equilibrium constant. The availability of molecular-sieve media with different selective porosities ensures that very little restriction is imposed on the size of solute amenable to study. Furthermore, access to a diverse array of assay procedures for monitoring the column eluate endows analytical exclusion chromatography with far greater flexibility than other techniques from the viewpoint of solute concentration range that can be examined. In addition to its widely recognized prowess as a means of solute separation and purification, exclusion chromatography thus also possesses considerable potential for investigating the functional roles of the purified solutes. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
We have calculated the equilibrium shape of the axially symmetric Plateau border along which a spherical bubble contacts a flat wall, by analytically integrating Laplace's equation in the presence of gravity, in the limit of small Plateau border sizes. This method has the advantage that it provides closed-form expressions for the positions and orientations of the Plateau border surfaces. Results are in very good overall agreement with those obtained from a numerical solution procedure, and are consistent with experimental data. In particular we find that the effect of gravity on Plateau border shape is relatively small for typical bubble sizes, leading to a widening of the Plateau border for sessile bubbles and to a narrowing for pendant bubbles. The contact angle of the bubble is found to depend even more weakly on gravity. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Mestrado em Radioterapia.
Resumo:
Mestrado em Radioterapia.
Resumo:
Mestrado em Radioterapia
Resumo:
The calculation of the dose is one of the key steps in radiotherapy planning1-5. This calculation should be as accurate as possible, and over the years it became feasible through the implementation of new algorithms to calculate the dose on the treatment planning systems applied in radiotherapy. When a breast tumour is irradiated, it is fundamental a precise dose distribution to ensure the planning target volume (PTV) coverage and prevent skin complications. Some investigations, using breast cases, showed that the pencil beam convolution algorithm (PBC) overestimates the dose in the PTV and in the proximal region of the ipsilateral lung. However, underestimates the dose in the distal region of the ipsilateral lung, when compared with analytical anisotropic algorithm (AAA). With this study we aim to compare the performance in breast tumors of the PBC and AAA algorithms.