936 resultados para Active distribution networks


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper analyzes the static voltage stability of distribution networks with photovoltaic (PV) generators under contingencies. The analysis is carried out on a widely used 16-bus test system. The paper treats the Q-V characteristics of the distribution grid for various PV penetration levels. Simulation results show that a higher penetration of PV increases the static coltage stability of the system. However, the tripping of multiple PV generators due to external disturbances, overloading and loss of distribution lines reduces the voltage stability margin of the system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a decentralised controller design for doubly-fed induction generators (DFIGs) to enhance dynamic performance of distribution networks. The change in the output power due to the variable nature of wind is considered as an uncertain term in the design algorithm. In addition, the interconnection effect of the other subsystems are considered in the design process. The H norm of the uncertain system is found out and simultaneous output-feedback linear controllers are designed based controller is verified on a 16 bus distribution test system for severe disturbances. Simulation results indicate that the designed controller is robust against uncertainties in operating conditions

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes an optimal linear quadratic Gaussian (LQG) controller for D-STATCOM to improve the dynamic performance of distribution networks with photovoltaic generators. The controller is designed based on the H∞ norm of the uncertain system. The change in system model due to the variation of load compositions in the composite load is considered as an uncertain term in the design algorithm. The performance of the designed controller is demonstrated on a widely used test system. Simulation results indicate that the proposed controller can be a potential solution for improving the voltage stability of distribution networks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a distributed multi-agent scheme is presented for reactive power management with renewable energy sources (RESs). The multi-agent system (MAS) framework is developed for distribution systems to improve the stability which is mostly dominated by voltage and the agents in this framework coordinate among themselves using online information and energy flow. In this paper, the agents basically perform two tasks- reactive power estimation and necessary control actions. The topology of distribution network is used to estimate the required reactive power for maintaining voltage stability where distributed static synchronous compensators (DSTATCOMs) are used to supply this reactive power. The DSTATCOM is controlled by using a linear quadratic regulator (LQR) controller within the agent framework. The proposed scheme is further compared with the conventional approach to validate the simulation results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Demands are one of the most uncertain parameters in a water distribution network model. A good calibration of the model demands leads to better solutions when using the model for any purpose. A demand pattern calibration methodology that uses a priori information has been developed for calibrating the behaviour of demand groups. Generally, the behaviours of demands in cities are mixed all over the network, contrary to smaller villages where demands are clearly sectorised in residential neighbourhoods, commercial zones and industrial sectors. Demand pattern calibration has a final use for leakage detection and isolation. Detecting a leakage in a pattern that covers nodes spread all over the network makes the isolation unfeasible. Besides, demands in the same zone may be more similar due to the common pressure of the area rather than for the type of contract. For this reason, the demand pattern calibration methodology is applied to a real network with synthetic non-geographic demands for calibrating geographic demand patterns. The results are compared with a previous work where the calibrated patterns were also non-geographic.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drinking water distribution networks risk exposure to malicious or accidental contamination. Several levels of responses are conceivable. One of them consists to install a sensor network to monitor the system on real time. Once a contamination has been detected, this is also important to take appropriate counter-measures. In the SMaRT-OnlineWDN project, this relies on modeling to predict both hydraulics and water quality. An online model use makes identification of the contaminant source and simulation of the contaminated area possible. The objective of this paper is to present SMaRT-OnlineWDN experience and research results for hydraulic state estimation with sampling frequency of few minutes. A least squares problem with bound constraints is formulated to adjust demand class coefficient to best fit the observed values at a given time. The criterion is a Huber function to limit the influence of outliers. A Tikhonov regularization is introduced for consideration of prior information on the parameter vector. Then the Levenberg-Marquardt algorithm is applied that use derivative information for limiting the number of iterations. Confidence intervals for the state prediction are also given. The results are presented and discussed on real networks in France and Germany.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The neutral wire in most existing power flow and fault analysis software is usually merged into phase wires using Kron's reduction method. In some applications, such as fault analysis, fault location, power quality studies, safety analysis, loss analysis etc., knowledge of the neutral wire and ground currents and voltages could be of particular interest. A general short-circuit analysis algorithm for three-phase four-wire distribution networks, based on the hybrid compensation method, is presented. In this novel use of the technique, the neutral wire and assumed ground conductor are explicitly represented. A generalised fault analysis method is applied to the distribution network for conditions with and without embedded generation. Results obtained from several case studies on medium- and low-voltage test networks with unbalanced loads, for isolated and multi-grounded neutral scenarios, are presented and discussed. Simulation results show the effects of neutrals and system grounding on the operation of the distribution feeders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The problems of wave propagation and power flow in the distribution network composed of an overhead wire parallel to the surface of the ground have not been satisfactorily solved. While a complete solution of the actual problem is impossible, as it is explained in the famous Carson's paper (1926), the solution of the problem, where the actual earth is replaced by a plane homogenous semi-infinite solid, is of considerable interest. In this paper, a power flow algorithm in distribution networks with earth return, based on backward-forward technique, is discussed. In this novel use of the technique, the ground is explicitly represented. In addition, an iterative method for determining impedance for modelling ground effect in the extended power flow algorithm is suggested. Results obtained from single-wire and three-wire studies using IEEE test networks are presented and discussed. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The capacitor placement (replacement) problem for radial distribution networks determines capacitor types, sizes, locations and control schemes. Optimal capacitor placement is a hard combinatorial problem that can be formulated as a mixed integer nonlinear program. Since this is a NP complete problem (Non Polynomial time) the solution approach uses a combinatorial search algorithm. The paper proposes a hybrid method drawn upon the Tabu Search approach, extended with features taken from other combinatorial approaches such as genetic algorithms and simulated annealing, and from practical heuristic approaches. The proposed method has been tested in a range of networks available in the literature with superior results regarding both quality and cost of solutions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The neutral wire in most power flow software is usually merged into phase wires using Kron's reduction. Since the neutral wire and the ground are not explicitly represented, neutral wire and ground currents and voltages remain unknown. In some applications, like power quality and safety analyses, loss analysis, etc., knowing the neutral wire and ground currents and voltages could be of special interest. In this paper, a general power flow algorithm for three-phase four-wire radial distribution networks, considering neutral grounding, based on backward-forward technique, is proposed. In this novel use of the technique, both the neutral wire and ground are explicitly represented. A problem of three-phase distribution system with earth return, as a special case of a four-wire network, is also elucidated. Results obtained from several case studies using medium- and low-voltage test feeders with unbalanced load, are presented and discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a comparison of reactive power support in distribution networks provided by switched Capacitor Banks (CBs) and Distributed Generators (DGs). Regarding switched CBs, a Tabu Search metaheuristic algorithm is developed to determine their optimal operation with the objective of reducing the power losses in the lines on the system, while meeting network constraints. on the other hand, the optimal operation of DGs is analyzed through an evolutionary Multi-Objective (MO) programming approach. The objectives of such approach are the minimization of power losses and operation cost of the DGs. The comparison of the reactive power support provided by switched CBs and DGs is carried out using a modified IEEE 34 bus distribution test system.