213 resultados para 99mTc-Timina
Resumo:
This paper presents work in progress, to develop an efficient and economic way to directly produce Technetium 99metastable (99mTc) using low-energy cyclotrons. Its importance is well established and relates with the increased global trouble in delivering 99mTc to Nuclear Medicine Departments relying on this radioisotope. Since the present delivery strategy has clearly demonstrated its intrinsic limits, our group decided to follow a distinct approach that uses the broad distribution of the low energy cyclotrons and the accessibility of Molybdenum 100 (100Mo) as the Target material. This is indeed an important issue to consider, since the system here presented, named CYCLOTECH, it is not based on the use of Highly Enriched (or even Low Enriched) Uranium 235 (235U), so entirely complying with the actual international trends and directives concerning the use of this potential highly critical material. The production technique is based on the nuclear reaction 100Mo (p,2n) 99mTc whose production yields have already been documented. Until this moment two Patent requests have already been submitted (the first at the INPI, in Portugal, and the second at the USPTO, in the USA); others are being prepared for submission on a near future. The object of the CYCLOTECH system is to present 99mTc to Nuclear Medicine radiopharmacists in a routine, reliable and efficient manner that, remaining always flexible, entirely blends with established protocols. To facilitate workflow and Radiation Protection measures, it has been developed a Target Station that can be installed on most of the existing PET cyclotrons and that will tolerate up to 400 μA of beam by allowing the beam to strike the Target material at an adequately oblique angle. The Target Station permits the remote and automatic loading and discharge of the Targets from a carriage of 10 Target bodies. On other hand, several methods of Target material deposition and Target substrates are presented. The object was to create a cost effective means of depositing and intermediate the target material thickness (25 - 100μm) with a minimum of loss on a substrate that is able to easily transport the heat associated with high beam currents. Finally, the separation techniques presented are a combination of both physical and column chemistry. The object was to extract and deliver 99mTc in the identical form now in use in radiopharmacies worldwide. In addition, the Target material is recovered and can be recycled.
Resumo:
Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.
Resumo:
Introdução – A tomografia de emissão de fotão simples sincronizada com o sinal eletrocardiográfico (Gated-SPECT) é essencial para a avaliação conjunta da perfusão e da função ventricular esquerda (VE) do miocárdio. Objetivo – Investigar a relação entre a função VE e o índice de captação (IC) miocárdio/pulmão direito (M/PD) e M/P esquerdo (M/PE) nos estudos Gated-SPECT com 99mTc-Tetrofosmina. Metodologia – Amostra de 32 pacientes que realizaram estudos Gated-SPECT por indicação clínica, sendo subdividida em dois grupos: Grupo I (GI) – pacientes com a informação clínica de enfarte agudo do miocárdio (EAM); Grupo II (GII) – pacientes com a informação clínica de isquemia. Por cada paciente adquiriram-se imagens estáticas torácico-abdominais e dois estudos Gated-SPECT do miocárdio (protocolo de um dia esforço/repouso). Nas imagens estáticas
definiram-se regiões de interesse (Regions of interest – ROI) para calcular os IC. Nos estudos Gated-SPECT utilizou-se o software Quantitative Gated SPECT/Quantitative Perfusion SPECT para calcular a Fração de Ejeção do Ventrículo Esquerdo (FEVE). Efetuou-se análise estatística descritiva para caracterização da amostra. Aplicou-se o teste de Spearman para avaliar a correlação entre a FEVE e os IC por grupo de pacientes. O Teste de Willcoxon foi usado para comparar FEVE em repouso e em esforço. Resultados – Nos estudos Gated-SPECT em esforço não se verificou correlação estatisticamente significativa entre a FEVE e os IC, para GI e GII; em repouso existe correlação positiva estatisticamente significativa entre a FEVE e os IC, para GI; para GII não se verificou correlação. Na comparação dos valores de FEVE em esforço e repouso nos dois grupos constatou-se a existência de diferenças estatisticamente significativas, sendo a FEVE em Esforço
Resumo:
Mestrado em Medicina Nuclear - Ramo de especialização: Tomografia por Emissão de Positrões
Resumo:
Mestrado em Medicina Nuclear - Ramo de especialização: Radiofarmácia
Resumo:
Myocardial perfusion gated-single photon emission computed tomography (gated-SPECT) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. The aim of this study is to analyze the influence of counts/pixel and concomitantly the total counts in the myocardium for the calculation of myocardial functional parameters. Material and methods: Gated-SPECT studies were performed using a Monte Carlo GATE simulation package and the NCAT phantom. The simulations of these studies use the radiopharmaceutical 99mTc-labeled tracers (250, 350, 450 and 680MBq) for standard patient types, effectively corresponding to the following activities of myocardium: 3, 4.2, 5.4-8.2MBq. All studies were simulated using 15 and 30s/projection. The simulated data were reconstructed and processed by quantitative-gated-SPECT software, and the analysis of functional parameters in gated-SPECT images was done by using Bland-Altman test and Mann-Whitney-Wilcoxon test. Results: In studies simulated using different times (15 and 30s/projection), it was noted that for the activities for full body: 250 and 350MBq, there were statistically significant differences in parameters Motility and Thickness. For the left ventricular ejection fraction (LVEF), end-systolic volume (ESV) it was only for 250MBq, and 350MBq in the end-diastolic volume (EDV), while the simulated studies with 450 and 680MBq showed no statistically significant differences for global functional parameters: LVEF, EDV and ESV. Conclusion: The number of counts/pixel and, concomitantly, the total counts per simulation do not significantly interfere with the determination of gated-SPECT functional parameters, when using the administered average activity of 450MBq, corresponding to the 5.4MBq of the myocardium, for standard patient types.
Resumo:
Determinaram-se o tempo de trânsito esofágico (TTE) e o tempo decorrido até a abertura da cárdia (TDAC) para um líquido de prova administrado por via oral em 40 voluntários (Grupo I) e em 106 pacientes com enfermidade de Chagas (Grupo II), pelo estudo cintilográfico do esôfago com pertecnetato-99mTc. Imagens seqüenciais do trânsito esofagiano do traçador foram obtidas com câmara de cintilação. Curvas de variação da atividade versus tempo na região da cárdia foram registradas por seleção de área de interesse e com o auxílio de um processador multi-canal. No Grupo I o TTE e TDAC foram superponíveis, com média x = 13,2s, desvio padrão δ l,35s e coeficiente de variação 10%, estabelecendo-se o valor de 15,9s (x + 2 δ) como limite superior da mortalidade. Dos 106 chagásicos, 39 (36,8%) apresentaram apenas o TTE aumentado; 6 (5,6%) apenas o TDAC e 7 (6,6%) ambos os tempos aumentados. Os valores foram alterados em 36,0% dos pacientes do sexo masculino e em 51,0% dos pacientes do sexo feminino. Sintomas de disfagia e/ou pirose estavam presentes em 51,1% dos pacientes com tempos aumentados e em 24,6% dos com tempos normais. Os Autores propõem a determinação dos dois parâmetros TTE e TDAC pelo método ensaiado como possível meio de diagnóstico precoce da peristalse do esôfago e de avaliação de tratamentos instituídos.
Resumo:
This report describes two patients with chronic Chagas' Heart Disease who developed clinical and laboratorial signs of myocardial infarction. Both patients presented sudden oppressive chest pain, without precipitating factor. In the first case, the highest MB-CK value was 65 IU, 22 hours after the beginning of the pain. On the second case, it was 77 IU at 18 hours after the beginning of the pain. In both cases ECG changes suggesting non-transmural infarction were present. The 99mTc PYP myocardial scintigram of the first case was positive. Coronary angiograms performed on the 18th and 9th day, respectively, after the acute infarction did not display obstructive lesions. Possible mechanisms causing myocardial infarction with normal coronary arteries in Chagas' Disease may include: embolic event's, particularly when there is associated congestive heart failure; coronary thrombosis and coronary spasms.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Biomédica
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Física
Resumo:
Dissertação para obtenção do Grau de Mestre em Genética Molecular e Biomedicina
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
A case of parasitic thyroid nodule is presented. The patient was a non symptomatic 53-year-old white woman, on irregular course of L-thyroxine to treat hypothyroidism due to Hashimoto's thyroiditis. Without a history of thyroid trauma or surgery, she presented a 1.6 x 0.7 x 0.5cm right pre-laryngeal lymph node-like mass which, on ultrasonography, appeared distinct from the gland. TSH, thyroid peroxidase antibody and thyroglobulin antibody serum levels were elevated and T4-free level was normal. Thyroid and total body 99mTc isonitrile scintiscan showed a topic thyroid without radionuclide uptake in the nodule. Fine-needle aspiration of the nodule showed epithelial cells with nuclear atypia and oncocytic changes plus intense lymphoid infiltration and germinative center formation, simulating lymph node metastasis of papillary thyroid carcinoma. Conventional biopsy revealed a parasitic thyroid nodule with Hashimoto's chronic thyroiditis. Parasitic thyroid nodule must always be remembered so that unnecessary surgical assessment and undesirable sequels may be avoided.
Resumo:
OBJECTIVE: To compare single-photon-emission computed tomography (SPECT) imaging scans using 201Tl and 99mTc-MIBI in detection of viable myocardium, in regions compromised by infarction. METHODS: Thirty-two (59.3±9.8 years old and 87% male) myocardial infarction patients were studied. All had Q waves on the ECG and left ventricle ejection fraction of <50%. They underwent coronary and left ventricle angiographies and SPECT before (including 201Tl reinjection) and after coronary artery bypass surgery (CABG). Improvement in perfusion observed after surgery was considered the gold standard for myocardial viability. RESULTS: Among 102 studied regions of the heart, there were 40 (39.2%) areas of transient perfusion defects in the conventional protocol with 201Tl and 52 (51.0%) after reinjection. Therefore, 12/62 (19.4%) more viable regions were identified by reinjection. Using 99mTc-MIBI, only 14 (13.7%) regions with transient defects were identified, all of which were seen also in 201Tl protocols. After surgery, 49 of a total of 93 regions analyzed (52.7%) were viable. Sensitivity, specificity, accuracy, positive and negative prediction values were, respectively, 201Tl SPECT scans - 65.3%, 90.9%, 77.4%, 88.9% and 70.2%, reinjection protocol with 201Tl scans - 81.6%, 81.8%, 81.7%, 83.3% and 80.0%; 99mTc-MIBI SPECT scans - 20.4%, 90.9%, 53.8%, 71.4% and 50.6%. Logistic regression demonstrated that the reinjection protocol with 201Tl was the best predictor of viability (P<0.001). CONCLUSION: Our data suggest the election of 201Tl for viability studies, especially when using the reinjection protocol.
Resumo:
OBJETIVO: Estabelecer a correlação da cintilografia de perfusão do miocárdio (CPM) com Tecnécio 99m-MIBI (MIBI) e injeção de adenosina, empregando a angiografia coronária quantitativa (ACQ) e o ultra-som intracoronário (UIC) como comparação. MÉTODOS: Estudo de 70 pacientes com doença arterial coronária (DAC), encaminhados à CPM com MIBI e adenosina. As manifestações clínicas, do eletrocardiograma (ECG) e os resultados das imagens foram correlacionadas às variáveis da análise visual e quantitativa da angiografia, bem como ao UIC. RESULTADOS: A média de idades foi de 60,6 anos, com 39 pacientes do sexo masculino. A angiografia coronária evidenciou estenose do diâmetro da luz (E%) de 49,94% em 105 artérias, com reavaliação à ACQ em 83 artérias (79%) e média de 44,20%, p<0,05. Infradesnível de ST durante adenosina associou-se a maiores graus de E% (55,0% vs 47,8%), p<0,05). A isquemia cintilográfica correlacionou-se a maior área porcentual de obstrução da luz pelo UIC (AO%). Os achados clínicos, do ECG e das imagens foram considerados em conjunto e expressos como respostas globais isquêmicas versus não-isquêmicas . A isquemia associou-se a menores valores do diâmetro mínimo da luz (DML) e da área mínima da luz (AML), obtidos à ACQ e ao UIC. CONCLUSÃO: A cintilografia do miocárdio com 99mTc-MIBI e adenosina correlaciona-se à AO% ao UIC, considerando-se as imagens de perfusão. Na avaliação dos resultados globais da prova observa-se associação com os diâmetros e as áreas da luz nos locais de obstrução, obtidos à ACQ e ao UIC.