899 resultados para ventilatory threshold


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this chapter we continue the exposition of crypto topics that was begun in the previous chapter. This chapter covers secret sharing, threshold cryptography, signature schemes, and finally quantum key distribution and quantum cryptography. As in the previous chapter, we have focused only on the essentials of each topic. We have selected in the bibliography a list of representative items, which can be consulted for further details. First we give a synopsis of the topics that are discussed in this chapter. Secret sharing is concerned with the problem of how to distribute a secret among a group of participating individuals, or entities, so that only predesignated collections of individuals are able to recreate the secret by collectively combining the parts of the secret that were allocated to them. There are numerous applications of secret-sharing schemes in practice. One example of secret sharing occurs in banking. For instance, the combination to a vault may be distributed in such a way that only specified collections of employees can open the vault by pooling their portions of the combination. In this way the authority to initiate an action, e.g., the opening of a bank vault, is divided for the purposes of providing security and for added functionality, such as auditing, if required. Threshold cryptography is a relatively recently studied area of cryptography. It deals with situations where the authority to initiate or perform cryptographic operations is distributed among a group of individuals. Many of the standard operations of single-user cryptography have counterparts in threshold cryptography. Signature schemes deal with the problem of generating and verifying electronic) signatures for documents.Asubclass of signature schemes is concerned with the shared-generation and the sharedverification of signatures, where a collaborating group of individuals are required to perform these actions. A new paradigm of security has recently been introduced into cryptography with the emergence of the ideas of quantum key distribution and quantum cryptography. While classical cryptography employs various mathematical techniques to restrict eavesdroppers from learning the contents of encrypted messages, in quantum cryptography the information is protected by the laws of physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently a convex hull based human identification protocol was proposed by Sobrado and Birget, whose steps can be performed by humans without additional aid. The main part of the protocol involves the user mentally forming a convex hull of secret icons in a set of graphical icons and then clicking randomly within this convex hull. In this paper we show two efficient probabilistic attacks on this protocol which reveal the user’s secret after the observation of only a handful of authentication sessions. We show that while the first attack can be mitigated through appropriately chosen values of system parameters, the second attack succeeds with a non-negligible probability even with large system parameter values which cross the threshold of usability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Secure multi-party computation (MPC) protocols enable a set of n mutually distrusting participants P 1, ..., P n , each with their own private input x i , to compute a function Y = F(x 1, ..., x n ), such that at the end of the protocol, all participants learn the correct value of Y, while secrecy of the private inputs is maintained. Classical results in the unconditionally secure MPC indicate that in the presence of an active adversary, every function can be computed if and only if the number of corrupted participants, t a , is smaller than n/3. Relaxing the requirement of perfect secrecy and utilizing broadcast channels, one can improve this bound to t a  < n/2. All existing MPC protocols assume that uncorrupted participants are truly honest, i.e., they are not even curious in learning other participant secret inputs. Based on this assumption, some MPC protocols are designed in such a way that after elimination of all misbehaving participants, the remaining ones learn all information in the system. This is not consistent with maintaining privacy of the participant inputs. Furthermore, an improvement of the classical results given by Fitzi, Hirt, and Maurer indicates that in addition to t a actively corrupted participants, the adversary may simultaneously corrupt some participants passively. This is in contrast to the assumption that participants who are not corrupted by an active adversary are truly honest. This paper examines the privacy of MPC protocols, and introduces the notion of an omnipresent adversary, which cannot be eliminated from the protocol. The omnipresent adversary can be either a passive, an active or a mixed one. We assume that up to a minority of participants who are not corrupted by an active adversary can be corrupted passively, with the restriction that at any time, the number of corrupted participants does not exceed a predetermined threshold. We will also show that the existence of a t-resilient protocol for a group of n participants, implies the existence of a t’-private protocol for a group of n′ participants. That is, the elimination of misbehaving participants from a t-resilient protocol leads to the decomposition of the protocol. Our adversary model stipulates that a MPC protocol never operates with a set of truly honest participants (which is a more realistic scenario). Therefore, privacy of all participants who properly follow the protocol will be maintained. We present a novel disqualification protocol to avoid a loss of privacy of participants who properly follow the protocol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In moderate to high sea states, the effectiveness of ship fin stabilizers can severely deteriorate due to nonlinear effects arising from unsteady hydrodynamic characteristics of the fins: dynamic stall. These nonlinear effects take the form of a hysteresis, and they become very significant when the effective angle of attack of the fins exceeds a certain threshold angle. Dynamic stall can result in a complete loss of control action depending on how much the fins exceed the threshold angle. When this is detected, it is common to reduce the gain of the controller that commands the fins. This approach is cautious and tends to reduce performance when the conditions leading to dynamic stall disappear. An alternative approach for preventing the effects while keeping high performance, consists of estimating the effective angle of attack and set a conservative constraint on it as part of the control objectives. In this paper, we investigate the latter approach, and propose the use of a model predictive control (MPC) to prevent the development of these nonlinear effects by considering constraints on both the mechanical angle of the fins and the effective angle of attack.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Lumbar Epidural Steroids Injections (ESI’s) have previously been shown to provide some degree of pain relief in sciatica. Number Needed To Treat (NNT) to achieve 50% pain relief has been estimated at 7 from the results of randomised controlled trials. Pain relief is temporary. They remain one of the most commonly provided procedures in the UK. It is unknown whether this pain relief represents good value for money. Methods 228 patients were randomised into a multi-centre Double Blind Randomised Controlled Trial. Subjects received up to 3 ESI’s or intra-spinous saline depending on response and fall off with the first injection. All other treatments were permitted. All received a review of analgesia, education and physical therapy. Quality of life was assessed using the SF36 at 6 points and compared using independent sample t-tests. Follow up was up to 1 yr. Missing data was imputed using last observation carried forward (LOCF). QALY’s (Quality of Life Years) were derived from preference based heath values (summary health utility score). SF-6D health state classification was derived from SF-36 raw score data. Standard gambles (SG) were calculated using Model 10. SG scores were calculated on trial results. LOCF was not used for this. Instead average SG were derived for a subset of patients with observations for all visits up to week 12. Incremental QALY’s were derived as the difference in the area between the SG curve for the active group and placebo group. Results SF36 domains showed a significant improvement in pain at week 3 but this was not sustained (mean 54 Active vs 61 Placebo P<0.05). Other domains did not show any significant gains compared with placebo. For derivation of SG the number in the sample in each period differed. In week 12, average SG scores for active and placebo converged. In other words, the health gain for the active group as measured by SG was achieved by the placebo group by week 12. The incremental QALY gained for a patient under the trial protocol compared with the standard care package was 0.0059350. This is equivalent to an additional 2.2 days of full health. The cost per QALY gained to the provider from a patient management strategy administering one epidural as suggested by results was £25 745.68. This result was derived assuming that the gain in QALY data calculated for patients under the trial protocol would approximate that under a patient management strategy based on the trial results (one ESI). This is above the threshold suggested by some as a cost effective treatment. Conclusions The transient benefit in pain relief afforded by ESI’s does not appear to be cost-effective. Further work is needed to develop more cost-effective conservative treatments for sciatica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Institutional graduate capabilities and discipline threshold learning outcomes require science students to demonstrate ethical conduct and social responsibility. However, neither the teaching nor the assessment of these concepts is straightforward. Australian chemistry academics participated in a workshop in 2013 to discuss and develop teaching and assessment in these areas and this paper reports on the outcomes of that workshop. Controversial issues discussed included: How broad is the mandate of the teacher, how should the boundaries between personal values and ethics be drawn, and how can ethics be assessed without moral judgement? In this position paper, I argue for a deep engagement with ethics and social justice, achieved through case studies and assessed against criteria that require discussion and debate. Strategies to effectively assess science students’ understanding of ethics and social responsibility are detailed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The planning of IMRT treatments requires a compromise between dose conformity (complexity) and deliverability. This study investigates established and novel treatment complexity metrics for 122 IMRT beams from prostate treatment plans. The Treatment and Dose Assessor software was used to extract the necessary data from exported treatment plan files and calculate the metrics. For most of the metrics, there was strong overlap between the calculated values for plans that passed and failed their quality assurance (QA) tests. However, statistically significant variation between plans that passed and failed QA measurements was found for the established modulation index and for a novel metric describing the proportion of small apertures in each beam. The ‘small aperture score’ provided threshold values which successfully distinguished deliverable treatment plans from plans that did not pass QA, with a low false negative rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper provides a contextual reflection for understanding best practice teaching to first year design students. The outcome (job) focussed approach to higher education has lead to some unanticipated collateral damage for students, and in the case we discuss, has altered the students’ expectations of course delivery with specific implications and challenges for design educators. This tendency in educational delivery systems is further compounded by the distinct characteristics of Generation Y students within a classroom context. It is our belief that foundational design education must focus more on process than outcomes, and through this research with first year design students we analyse and raise questions relative to the curriculum for a Design and Creative Thinking course—in which students not only benefit from learning the theories and processes of design thinking, conceptualisation and creativity, but also are encouraged to see it as an essential tool for their education and development as designers. This study considers the challenges within a design environment; specifically, we address the need for process based learning in contrast to the outcome-focused approach taken by most students. With this approach, students simultaneously learn to be a designer and rethink their approach to “doing design”.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to derive ActiGraph cut-points for sedentary (SED), light-intensity physical activity (LPA), and moderate-to-vigorous physical activity (MVPA) in toddlers and evaluate their validity in an independent sample. The predictive validity of established preschool cut-points were also evaluated and compared. Twenty-two toddlers (mean age = 2.1 years ± 0.4 years) wore an ActiGraph accelerometer during a videotaped 20-min play period. Videos were subsequently coded for physical activity (PA) intensity using the modified Children's Activity Rating Scale (CARS). Receiver operating characteristic (ROC) curve analyses were conducted to determine cut-points. Predictive validity was assessed in an independent sample of 18 toddlers (mean age = 2.3 ± 0.4 years). From the ROC curve analyses, the 15-s count ranges corresponding to SED, LPA, and MVPA were 0–48, 49–418, and >418 counts/15 s, respectively. Classification accuracy was fair for the SED threshold (ROC-AUC = 0.74, 95% confidence interval = 0.71–0.76) and excellent for MVPA threshold (ROC-AUC = 0.90, 95% confidence interval = 0.88–0.92). In the cross-validation sample, the toddler cut-point and established preschool cut-points significantly overestimated time spent in SED and underestimated time in spent in LPA. For MVPA, mean differences between observed and predicted values for the toddler and Pate cut-points were not significantly different from zero. In summary, the ActiGraph accelerometer can provide useful group-level estimates of MVPA in toddlers. The results support the use of the Pate cut-point of 420 counts/15 s for MVPA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The unique physical and movement characteristics of children necessitate the development of accelerometer equations and cut points that are population specific. The purpose of this study is to develop an ecologically valid cut point for the Biotrainer Pro monitor that reflects a threshold for moderate-intensity physical activity in elementary school children. A sample of 30 children (ages 8-12) wore a Biotrainer monitor while completing a series of 7 movement tasks (calibration phase) and while participating in an organized group activity (cross-validation phase). Videotapes from each session were processed using a computerized direct-observation technique to provide a criterion measure of physical activity. Analyses involved the use of mixed-model regression and receiver operator characteristic (ROC) curves. The results indicated that a cut point of 4 counts/min provides the optimal balance between the related needs for sensitivity (accurately detecting activity) and specificity (limiting misclassification of activity as inactivity). Results with the cross-validation data demonstrated that this value yielded the best overall kappa (.58) and a high classification agreement (84%) for activity determination. The specificity of 93% demonstrates that the proposed cut point can accurately detect activity; however, the lower sensitivity value of 61% suggests that some minutes of activity might be incorrectly classified as inactivity. The cut point of 4 counts/min provides an ecologically valid cut point to capture physical activity in children using the Biotrainer Pro activity monitor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the TREC Web Diversity track, novelty-biased cumulative gain (α-NDCG) is one of the official measures to assess retrieval performance of IR systems. The measure is characterised by a parameter, α, the effect of which has not been thoroughly investigated. We find that common settings of α, i.e. α=0.5, may prevent the measure from behaving as desired when evaluating result diversification. This is because it excessively penalises systems that cover many intents while it rewards those that redundantly cover only few intents. This issue is crucial since it highly influences systems at top ranks. We revisit our previously proposed threshold, suggesting α be set on a query-basis. The intuitiveness of the measure is then studied by examining actual rankings from TREC 09-10 Web track submissions. By varying α according to our query-based threshold, the discriminative power of α-NDCG is not harmed and in fact, our approach improves α-NDCG's robustness. Experimental results show that the threshold for α can turn the measure to be more intuitive than using its common settings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Novelty-biased cumulative gain (α-NDCG) has become the de facto measure within the information retrieval (IR) community for evaluating retrieval systems in the context of sub-topic retrieval. Setting the incorrect value of parameter α in α-NDCG prevents the measure from behaving as desired in particular circumstances. In fact, when α is set according to common practice (i.e. α = 0.5), the measure favours systems that promote redundant relevant sub-topics rather than provide novel relevant ones. Recognising this characteristic of the measure is important because it affects the comparison and the ranking of retrieval systems. We propose an approach to overcome this problem by defining a safe threshold for the value of α on a query basis. Moreover, we study its impact on system rankings through a comprehensive simulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to determine the threshold of exercise energy expenditure necessary to change blood lipid and lipoprotein concentrations and lipoprotein lipase activity (LPLA) in healthy, trained men. On different days, 11 men (age, 26.7 +/- 6.1 yr; body fat, 11.0 +/- 1.5%) completed four separate, randomly assigned, submaximal treadmill sessions at 70% maximal O-2 consumption. During each session 800, 1,100, 1,300, or 1,500 kcal were expended. Compared with immediately before exercise, high-density lipoprotein cholesterol (HDL-C) concentration was significantly elevated 24 h after exercise (P < 0.05) in the 1,100-, 1,300-, and 1,500-kcal sessions. HDL-C concentration was also elevated (P < 0.05) immediately after and 48 h after exercise in the 1,500-kcal session. Compared with values 24 h before exercise, LPLA. was significantly greater (P < 0.05) 24 h after exercise in the 1,100-, 1,300-, and 1,500-kcal sessions and remained elevated 48 h after exercise in the 1,500-kcal session. These data indicate that, in healthy, trained men, 1,100 kcal of energy expenditure are necessary to elicit increased HDL-C concentrations. These HDL-C changes coincided with increased LPLA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to examine the effect of prolonged exercise oil plasma lipid and lipoprotein concentrations and to identify caloric time-points where changes occurred. Eleven active male Subjects ran oil a treadmill at 70%,, of maximal fitness (VO2max) and expended 6 278.7 kilojoules (Kj) energy (1500 kcal). Blood samples were obtained at the 4185.8 Kj (1000 kcal) time-point during exercise and at each additional 418.6 Kj (100 kcal) expenditure until 6278.7 Kj was expended. After correcting for plasma volume changes, decreases in low-density lipoprotein cholesterol (LDL-C) were observed during exercise at time-points corresponding to 4604.4 and 5441.5 Kj (1100 and 1300 kcal) of energy expenditure, and immediately after exercise. Total cholesterol concentrations decreased significantly at exercise kilojoule expenditures of 4604.4, 5441.5 and 5860.1 (1100, 1300 and 1400 kcal). There were also exercise induced increases in high-density lipoprotein cholesterol (HDL-C) and HDL2-C concentrations immediately after exercise. Although acute lipid and lipoprotein changes are typically reported in the days following exercise, the Current data indicate that some lipoprotein concentrations change during acute exercise. Our data suggest that a threshold of exercise may be necessary to change lipoproteins during exercise. Future work Should identify potential mechanisms (lipoprotein lipase, cholesterol ester transport protein, LDL uptake) that alter lipoprotein concentrations during prolonged exercise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To establish the suitability of multiplex tandem polymerase chain reaction (MT-PCR) for rapid identification of oestrogen receptor (ER) and Her-2 status using a single, formalin-fixed, paraffin-embedded (FFPE) breast tumour section. Methods Tissue sections from 29 breast tumours were analysed by immunohistochemistry (IHC) and fluorescence in situ hybridisation (FISH). RNA extracted from 10μm FFPE breast tumour sections from 24 of 29 tumours (14 ER positive and 5 Her-2 positive) was analysed by MT-PCR. After establishing a correlation between IHC and/or FISH and MT-PCR results, the ER/Her-2 status of a further 32 randomly selected, archival breast tumour specimens was established by MT-PCR in a blinded fashion, and compared to IHC/FISH results. Results MT-PCR levels of ER and Her-2 showed good concordance with IHC and FISH results. Furthermore, among the ER positive tumours, MT-PCR provided a quantitative score with a high dynamic range. Threshold values obtained from this data set applied to 32 archival tumour specimens showed that tumours strongly positive for ER and/or Her-2 expression were easily identified by MT-PCR. Conclusion MT-PCR can provide rapid, sensitive and cost-effective analysis of FFPE material and may prove useful as triage to identify patients suited to endocrine or trastuzumab (Herceptin) treatment.