999 resultados para nonparametric test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods: The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results: Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contexte : Parmi les infections nosocomiales, le Staphylocoque méticilline résistant (MRSA) est le germe pathogène le plus couramment identifié dans les hôpitaux du monde entier. La stratégie de contrôle des MRSA au CHUV implique le dépistage des patients à risque. Avec la méthode de dépistage par culture, le temps d'attente est de plusieurs jours. Ceci occasionne des problèmes dans la gestion des flux des patients, principalement à cause des mesures d'isolement. Pour réduire le temps d'attente, l'hôpital envisage d'utiliser une méthode de diagnostic rapide par "polymerase chain reaction" (PCR). Méthodologie : Les données concernant les dépistages réalisés, dans trois services durant l'année 2007, ont été utilisées. Le nombre de jours d'isolement a d'abord été déterminé par patient et par service. Ensuite une analyse des coûts a été effectuée afin d'évaluer la différence des coûts entre les deux méthodes pour chaque service. Résultats : Le principal impact économique de la méthode par PCR dépend principalement du nombre de jours d'isolements évités par rapport à la méthode de culture. Aux services de soins, l'analyse a été menée sur 192 dépistages. Quand la différence de jours d'isolement est de deux jours, le coût des dépistages diminue de plus de 12kCHF et le nombre de jours d'isolement diminue de 384 jours. Au centre interdisciplinaire des urgences, sur 96 dépistages, le gain potentiel avec la méthode PCR est de 6kCHF avec une diminution de 192 jours d'isolement. Aux soins intensifs adultes, la méthode de dépistage par PCR est la méthode la plus rentable avec une diminution des coûts entre 4KCHF et 20K CHF et une diminution des jours d'isolement entre 170 et 310. Pour les trois services analysés, les résultats montrent un rapport coût-efficacité favorable pour la méthode PCR lorsque la diminution des jours d'isolement est supérieure à 1.3 jour. Quand la différence de jours d'isolement est inférieure à 1.3, il faut tenir compte d'autres paramètres, comme le coût de matériel qui doit être supérieur à 45.5 CHF, et du nombre d'analyses par dépistage, qui doit être inférieur à 3, pour que la PCR reste l'alternative la plus intéressante. Conclusions : La méthode par PCR montre des avantages potentiels importants, tant économiques qu'organisationnels qui limitent ou diminuent les contraintes liées à la stratégie de contrôle des MRSA au CHUV. [Auteure, p. 3]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conocer cuál es la personalidad de aquellos que acceden a nuestras Escuelas y que en pocos años se convertirán en futuros profesionales de Enfermería, ha sido el objetivo de un estudio llevado a cabo por la Comisión de Docencia de la E.U.E. de Barcelona. En él se realiza un análisis comparativo de los perfiles de personalidad de los estudiantes admitidos en la E.U.E. de Barcelona y los candidatos pre-inscritos en dicha escuela en 1983, frente a estudiantes de Enfermería americanas y británicas y los candidatos a estudiantes de Medicina de la Universidad de Navarra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most suitable method for estimation of size diversity is investigated. Size diversity is computed on the basis of the Shannon diversity expression adapted for continuous variables, such as size. It takes the form of an integral involving the probability density function (pdf) of the size of the individuals. Different approaches for the estimation of pdf are compared: parametric methods, assuming that data come from a determinate family of pdfs, and nonparametric methods, where pdf is estimated using some kind of local evaluation. Exponential, generalized Pareto, normal, and log-normal distributions have been used to generate simulated samples using estimated parameters from real samples. Nonparametric methods include discrete computation of data histograms based on size intervals and continuous kernel estimation of pdf. Kernel approach gives accurate estimation of size diversity, whilst parametric methods are only useful when the reference distribution have similar shape to the real one. Special attention is given for data standardization. The division of data by the sample geometric mean is proposedas the most suitable standardization method, which shows additional advantages: the same size diversity value is obtained when using original size or log-transformed data, and size measurements with different dimensionality (longitudes, areas, volumes or biomasses) may be immediately compared with the simple addition of ln k where kis the dimensionality (1, 2, or 3, respectively). Thus, the kernel estimation, after data standardization by division of sample geometric mean, arises as the most reliable and generalizable method of size diversity evaluation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the primary goals for food packages is to protect food against harmful environment, especially oxygen and moisture. The gas transmission rate is the total gas transport through the package, both by permeation through the package material and by leakage through pinholes and cracks. The shelf life of a product can be extended, if the food is stored in a gas tight package. Thus there is a need to test gas tightness of packages. There are several tightness testing methods, and they can be broadly divided into destructive and nondestructive methods. One of the most sensitive methods to detect leaks is by using a non destructive tracer gas technique. Carbon dioxide, helium and hydrogen are the most commonly used tracer gases. Hydrogen is the lightest and the smallest of all gases, which allows it to escape rapidly from the leak areas. The low background concentration of H2 in air (0.5 ppm) enables sensitive leak detection. With a hydrogen leak detector it is also possible to locate leaks. That is not possible with many other tightness testing methods. The experimental work has been focused on investigating the factors which affect the measurement results with the H2leak detector. Also reasons for false results were searched to avoid them in upcoming measurements. From the results of these experiments, the appropriate measurement practice was created in order to have correct and repeatable results. The most important thing for good measurement results is to keep the probe of the detector tightly against the leak. Because of its high diffusion rate, the HZ concentration decreases quickly if holding the probe further away from the leak area and thus the measured H2 leaks would be incorrect and small leaks could be undetected. In the experimental part hydrogen, oxygen and water vapour transmissions through laser beam reference holes (diameters 1 100 μm) were also measured and compared. With the H2 leak detector it was possible to detect even a leakage through 1 μm (diameter) within a few seconds. Water vapour did not penetrate even the largest reference hole (100 μm), even at tropical conditions (38 °C, 90 % RH), whereas some O2 transmission occurred through the reference holes larger than 5 μm. Thus water vapour transmission does not have a significant effect on food deterioration, if the diameter of the leak is less than 100 μm, but small leaks (5 100 μm) are more harmful for the food products, which are sensitive to oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fiscal policy rule implicit in the Stability and Growth Pact, has been rationalised as a way to ensure that national fiscal policies remain sustainable within the EU, thereby endorsing the independence of the ECB. We empirically examine the sustainability of European fiscal policies over the period 1970-2001. The intertemporal government budget constraint provides a test based on the cointegration relation between government revenues, expenditures and interest payments. Sustainability is analysed at both the national level and for a European panel. Results show that European fiscal policy has been sustainable overall, yet national experiences differ considerably.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The void structure of zeolites MCM-22, MCM-36 and ITQ-2 were discussed on the bases of catalytic reaction tests. The hydromerization of n-decane on bifunctional Pt/Zeolite Catalysts have been used as model reactions. Beta and ZSM-5 zeolites were used for comparison. It is concluded that all materials show features of 10MR zeolites and have also pores bigger than 12MR in this order MCM-22

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the context of the evidence-based practices movement, the emphasis on computing effect sizes and combining them via meta-analysis does not preclude the demonstration of functional relations. For the latter aim, we propose to augment the visual analysis to add consistency to the decisions made on the existence of a functional relation without losing sight of the need for a methodological evaluation of what stimuli and reinforcement or punishment are used to control the behavior. Four options for quantification are reviewed, illustrated, and tested with simulated data. These quantifications include comparing the projected baseline with the actual treatment measurements, on the basis of either parametric or nonparametric statistics. The simulated data used to test the quantifications include nine data patterns in terms of the presence and type of effect and comprising ABAB and multiple baseline designs. Although none of the techniques is completely flawless in terms of detecting a functional relation only when it is present but not when it is absent, an option based on projecting split-middle trend and considering data variability as in exploratory data analysis proves to be the best performer for most data patterns. We suggest that the information on whether a functional relation has been demonstrated should be included in meta-analyses. It is also possible to use as a weight the inverse of the data variability measure used in the quantification for assessing the functional relation. We offer an easy to use code for open-source software for implementing some of the quantifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to develop and validate a dissolution test for glibenclamide tablets. Optimal conditions to carry out the dissolution test are 500 mL of phosphate buffer at pH 8.0, paddles at 75 rpm stirring speed, time test set to 60 min and using equipment with six vessels. The derivative UV spectrophotometric method for determination of glibenclamide released was developed, validated and compared with the HPLC method. The UVDS method presents linearity (r² = 0.9999) in the concentration range of 5-14 µg/mL. Precision and recoveries were 0.42% and 100.25%, respectively. The method was applied to three products commercially available on the Brazilian market.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we describe both a chromatographic purification procedure and a spot test for the enzyme peroxidase (POD: EC 1.11.1.7). The enzyme was obtained from crude extracts of sweet potatoes and the chromatographic enzyme purification procedure resulted in several fractions. Therefore a simple, fast and economic spot test for monitoring peroxidase during the purification procedure was developed. The spot test is based on the reaction of hydrogen peroxide and guaiacol, which is catalyzed by the presence of peroxidase yielding the colored tetraguaiacol.