932 resultados para mini-screws


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To analyse the effects of two interventions on the cognition and balance of institutionalized elderly people with mixed dementia.Methods: Fifty-four participants were allocated into three groups. Group 1 was assisted by an interdisciplinary programme comprising physiotherapy, occupational therapy and physical education. A physiotherapist alone carried out the intervention in group 2. Group 3 was considered as control. Assessors were blinded to guarantee the absence of bias. Cognitive functions were analysed with the Mini-Mental State Examination and the Brief Cognitive Screening Battery. Balance was assessed with the Berg Balance Scale and the Timed Get-Up-and-Go Test. Multiple analysis of variance (MANOVA) was used to test possible main effects of the interventions.Results: The results showed benefits on the balance of subjects in both groups 1 (F=3.9, P < 0.05) and 2 (F= 3.1, P < 0.05), compared with group 3. MANOVA did not indicate benefits on the cognitive functions between groups 1 and 3 (F= 1.1, P > 0.05) and groups 2 and 3 (F= 1.6, P > 0.05). However, univariate analysis indicated some benefits of the interdisciplinary intervention on two specific domains measured by the Brief Cognitive Screening Battery (F=26.5, P < 0.05; F= 4.4, P < 0.05).Conclusion: Six months of multidisciplinary or physiotherapeutic intervention were able to improve a person's balance. Although global cognition did not improve through treatment, when the intervention was carried out on a multidisciplinary basis we observed an attenuation in the decline of global cognition on two specific cognitive domains. Exercises applied in different contexts may have positive outcomes for people with dementia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sexual selection is a crucial element to understand behavioral evolution. Teleost fish have been considered as good models for research on sexual selection in the last decades due to their variety of sexual behavior. Female fish can choose males based on body and behavioral traits, such as body size, body color, ornaments, territorial quality, nest size and courtship behavior. Choices are based upon several types of sensorial inputs, such as visual, chemical, sonorous and electrical signals. Intrasexual selection also acts on females because they can mate with a dominant individual in male-male competitions. For both approaches, there is an expectation regarding the benefits of sexual selection by means of female choice. However, in several cases females do not choose the dominant male. In this mini-review, we present and discuss both intersexual and intrasexual mechanisms of sexual selection in fish and point out that females do not always choose a male for mating.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The present study was designed to analyze strain distributions caused by varying the fixture-abutment design and fixture alignment.Materials and Methods: Three implants of external, internal hexagon, and Morse taper were embedded in the center of each polyurethane block in straight placement and offset placement. Four strain gauges (SGs) were bonded on the surface of polyurethane block, which was designated SG1 placed mesially adjacent to implant A, SG2 and SG3 were placed mesially and distally adjacent to the implant B and SG4 was placed distally adjacent to the implant C. The 30 superstructures' occlusal screws were tightened onto the Microunit abutments with a torque of 10 N cm using the manufacturers' manual torque-controlling device.Results: There were statistically significant differences in prosthetic connection (P value = 0.0074 < 0.5). There were no statistically significant differences in placement configuration/alignment (P value = 0.7812 > 0.5).Conclusion: The results showed fundamental differences in both conditions. There was no evidence that there was any advantage to offset implant placement in reducing the strain around implants. The results also revealed that the internal hexagon and Morse taper joints did not reduce the microstrain around implants. (Implant Dent 2011; 20:e24-e32)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O). Materials and Methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (mu). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05). Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (mu) (183.2 +/- 93.64) and axial straight line (285.3 +/- 61.04) and differences between nonaxial 1 mm offset (201.0 +/- 50.24) and nonaxial 1 mm straight line (315.8 +/- 59.28). Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)