1000 resultados para Validação de modelos
Resumo:
A rapid and efficient method for the analysis of histamine in wines using HPLC with fluorescence detection after derivatization was developed and validated. The method LOD and LOQ values were 0.25 and 0.50 mg L-1 respectively. The repeatability and intermediary precision for the instrument and for the method presented RSD values of 3.7 and 2.9%, and 6.0 and 5.6%, respectively. The recoveries were 95.5 and 89.9% for the fortification levels of 2 and 10 mg L-1. The method was applied to determine the histamine content in Cabernet Sauvignon wines, which presented values between 1.2 and 5.7 mg L-1.
Resumo:
La efectividad en el deporte hace referencia al impacto alcanzado por una acción llevada a cabo en condiciones habituales, estando presente en la ejecución de cualquier actividad física, referida a la capacidad para producir el efecto deseado, y está relacionada con la e$cacia, entendida como el efecto de una acción llevada a cabo en las mejores condiciones posibles, y que tiene como objetivo, lograr la meta, o conseguir el triunfo. El objetivo de este trabajo consistió en identificar la relación entre la zona y el tipo de golpe, desde la cual el tenista presenta mayor y menor efectividad en el juego. Para ello se observó a un tenista durante 12 entrenamientos con un rival de nivel equivalente, según la ATP, durante la temporada 2012-2013, registrando su situación en la cancha y el tipo de golpe de todas las devoluciones con éxito, entendido como obtención del punto o recuperación del saque. Se crearon tres criterios categóricos que constituyen un instrumento de observación para registrar el juego del tenista en la zona horizontal, y la zona vertical de la pista, además del tipo de golpe que realiza en términos de drive, revés, smash y dejada. Utilizando la técnica de regresión log-lineal, se obtuvieron resultados que indican que el jugador presenta una menor efectividad en los golpes realizados desde el lado izquierdo, y muestra una mayor efectividad en el drive y revés ejecutados desde media pista o fondo del lado derecho. La interpretación de los resultados aporta información sobre las localizaciones en la pista y los golpes, relacionados con su mayor y menor efectividad.
Resumo:
The validation of analytical methods was carried out for di-(ethylhexyl) phthalate (DEHP) and adipate (DEHA) the determination of in PVC films. The level of DEHP and DEHA in samples was determined by leaving the film in contact with n-heptane during 48 hours and analysis in a gas chromatograph (GC) equipped with a flame ionization detector and fused silica column with 5% phenylmethyl silicone in the dimensions 30 m x 0.53 mm x 2.65 mm. The results for detection and the quantification limits were smaller than the restriction limits. The recovery rates of DEHP and DEHA were, respectively, 69.10 and 75.30 %.
Resumo:
The liquid-liquid extraction with the low temperature partition technique was developed for the analysis of four pyrethroids in water by CG. Using a factorial design the extraction technique was optimised evaluating the effect of the variables ionic strength, contact time and proportion between sample and solvent volumes. The validation parameters sensitivity, precision, accuracy and detection and quantification limits were evaluated. The LOD and LOQ of the method varied from 1.1 to 3.2 µg L-1 and 2.7 to 9.5 µg L-1, respectively.
Resumo:
Itraconazole is a synthetic antifungal drug administered orally with a broad spectrum of activity against mycotic infections. The present work consists of the development and validation of analytical methodology for evaluation of itraconazole in pharmaceutical products by high performance liquid chromatography. The separation was made using the reversed-phase column LC-18, acetonitrile/diethylamine 0.05% v/v, 60:40 v/v, pH 8.0 as mobile phase, methanol as solvent and detection and quantification at 254 nm. The results here obtained show that the analytical methodology is accurate, reproducible, robust and linear over the concentration range 8.0-12.0 µg/mL of itraconazole. The method was applied to pharmaceutical capsules containg itraconazole pellets and showed to be efficient, yielding good results.
Resumo:
Least-squares support vector machines (LS-SVM) were used as an alternative multivariate calibration method for the simultaneous quantification of some common adulterants found in powdered milk samples, using near-infrared spectroscopy. Excellent models were built using LS-SVM for determining R², RMSECV and RMSEP values. LS-SVMs show superior performance for quantifying starch, whey and sucrose in powdered milk samples in relation to PLSR. This study shows that it is possible to determine precisely the amount of one and two common adulterants simultaneously in powdered milk samples using LS-SVM and NIR spectra.
Resumo:
Pantoprazole is a proton pump inhibitor used in the treatment of digestive ulcers, gastro-esophageal reflux disease and in the eradication of Helicobacter pylori. In this work, an analytical method was developed and validated for the quantification of sodium pantoprazole by HPLC. The method was specific, linear, precise and exact. In order to verify the stability of pantoprazole during dissolution assays, pantoprazole solution in phosphate buffer pH 7.4 was kept at room temperature and protected from light for 22 days. Pantoprazole presented less than 5% of degradation in 6 hours and the half live of the degradation was 124 h.
Resumo:
An HPLC method was validated to assay lamivudine and zidovudine combined in tablets. The chromatographic separation was carried out using methanol and acetate buffer pH 6.5 (50:50 v/v) and a RP-18 column, as mobile and stationary phase, respectively. The UV detection was at 270 nm. The method was linear in the range of 24 - 36 µg/mL (lamivudine) and 48 - 72 µg/mL (zidovudine). The recovery (accuracy) ranged from 101.35% to 103.04% and the precision (repeatability and intermediate precision) was less than 2%. The method can be also applied to the quantification of these drugs in the dissolution test of tablets containing both drugs.
Resumo:
The aim of this work was to develop and validate an analytical methodology for simultaneous determination of mebendazole and thiabendazole, two benzimidazoles used as anthelmintics. The method was based on high performance liquid chromatography, using a C18 column, a mobile phase composed of KH2PO4 0.05 mol L-1 and methanol 40:60 (v/v) and UV detection at 312 nm. The results showed that the method presented linearity from 60.0 to 140.0 µg mL-1 for mebendazole and from 99.6 to 232.4 g µL-1 for thiabendazole and it was considered selective, accurate, precise and robust according to the specific resolution from ANVISA, the Brazilian regulatory agency.
Resumo:
This paper proposes an alternate method to detect forbidden doping substances present in biological matrices of horseracing. The method was fully validated for caffeine, identified as the most frequent forbidden substance in the analysis conducted by the Antidoping Laboratory of the Brazilian Jockey Club, which adopts a zero threshold limit according to national and international horseracing practices. The metrological reliability of the method applied to toxicological analysis in biological matrices is discussed. Although the analytical method proposed for detection of a zero threshold level of the doping substance is qualitative, it was validated for the determination of the limiting value (also known as quantification limit value) introducing a criterion that prevents the issuing of incorrect results ("false-positives" and "false-negatives").
Resumo:
The aim of this work was to develop and validate a method of analysis of biodiesel:diesel blends using HRGC-MS in SIM mode. The proposed method is applicable to biodiesel from linoleic oils, such as soybean oil. The following results were obtained: linearity over the methyl linoleate concentration range of 250-2500 mg L-1 (R² > 0.999); limits of detection and quantification of 2 and 5 mg L-1, respectively; recovery from 82 to 96% of biodiesel in diesel and repeatability < 2% (RSD). Comparison between two operators showed that it is not necessary the same operator to do the analysis.
Resumo:
The main objective of this work is to develop an efficient procedure to determine glyphosate in soybean grains. The cleanup of the aqueous extracts was done in two steps, beginning with liquid-liquid partitioning and then solid-phase extraction with anion exchange resin. After derivatization with a mixture of trifluoroacetic anhydride (TFAA) and trifluoroethanol (TFE), quantification was done by gas chromatography coupled to mass spectrometry. The mean recovery and RSD of the spiked samples were, respectively, 80.5% and 3.1% at level 0.200 mg kg-1, 93.3% and 18.7% at level 0.500 mg kg-1 and 92% and 3.5% at level 1.000 mg kg-1. The method was linear in the working range (correlation coefficient = 0.9965).
Resumo:
This work presents the VALIDATION SPREADSHEET, a public domain tool that can be used to evaluate the figures of merit for univariate analytical methods. A real example of BTEX determination in environmental samples is included to illustrate its use. The spreadsheet has been developed for Excel® and Open Office®, and is available on the internet at http//lqta.iqm.unicamp.br.
Resumo:
The aim of this investigation is to study how Zr/Ti-PILC adsorbs metals. The physico-chemical proprieties of Zr/Ti-PILC have been optimized with pillarization processes and Cu(II), Ni(II) and Co(II) adsorption from aqueous solution has been carried out, with maximum adsorption values of 8.85, 8.30 and 7.78 x10-1 mmol g-1, respectively. The Langmuir, Freundlich and Temkin adsorption isotherm models have been applied to fit the experimental data with a linear regression process. The energetic effect caused by metal interaction was determined through calorimetric titration at the solid-liquid interface and gave a net thermal effect that enabled the calculation of the exothermic values and the equilibrium constant.
Resumo:
Complex B vitamins are present in some cereal foods and the ingestion of enriched products contributes to the recommended dietary intake of these micronutrients. To adapt the label of some products, it is necessary to develop and validate the analytical methods. These methods must be reliable and with enough sensitivity to analyze complex B vitamins naturally present in food at low concentration. The purpose of this work is to evaluate, with validated methods, the content of vitamins B1, B2, B6 and niacin in five cereal flours used in food industry (oat, rice, barley, corn and wheat).