986 resultados para SONIC-SPRAY IONIZATION


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Consumption of nicotine in the form of smokeless tobacco (snus, snuff, chewing tobacco) or nicotine-containing medication (gum, patch) may benefit sport practice. Indeed, use of snus seems to be a growing trend and investigating nicotine consumption amongst professional athletes is of major interest to sport authorities. Thus, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection and quantification of nicotine and its principal metabolites cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide in urine was developed. Sample preparation was performed by liquid-liquid extraction followed by hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS) operated in electrospray positive ionization (ESI) mode with selective reaction monitoring (SRM) data acquisition. The method was validated and calibration curves were linear over the selected concentration ranges of 10-10,000 ng/mL for nicotine, cotinine, trans-3-hydroxycotinine and 10-5000 ng/mL for nicotine-N'-oxide and cotinine-N-oxide, with calculated coefficients of determination (R(2)) greater than 0.95. The total extraction efficiency (%) was concentration dependent and ranged between 70.4 and 100.4%. The lower limit of quantification (LLOQ) for all analytes was 10 ng/mL. Repeatability and intermediate precision were ?9.4 and ?9.9%, respectively. In order to measure the prevalence of nicotine exposure during the 2009 Ice Hockey World Championships, 72 samples were collected and analyzed after the minimum of 3 months storage period and complete removal of identification means as required by the 2009 International Standards for Laboratories (ISL). Nicotine and/or metabolites were detected in every urine sample, while concentration measurements indicated an exposure within the last 3 days for eight specimens out of ten. Concentrations of nicotine, cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide were found to range between 11 and 19,750, 13 and 10,475, 10 and 8217, 11 and 3396, and 13 and 1640 ng/mL, respectively. When proposing conservative concentration limits for nicotine consumption prior and/or during the games (50 ng/mL for nicotine, cotinine and trans-3-hydroxycotinine and 25 ng/mL for nicotine-N'-oxide and cotinine-N-oxide), about half of the hockey players were qualified as consumers. These findings significantly support the likelihood of extensive smokeless nicotine consumption. However, since such conclusions can only be hypothesized, the potential use of smokeless tobacco as a doping agent in ice hockey requires further investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chromatographic separation of highly polar basic drugs with ideal ionspray mass spectrometry volatile mobile phases is a difficult challenge. A new quantification procedure was developed using hydrophilic interaction chromatography-mass spectrometry with turbo-ionspray ionization in the positive mode. After addition of deuterated internal standards and simple clean-up liquid extraction, the dried extracts were reconstituted in 500 microL pure acetonitrile and 5 microL was directly injected onto a Waters Atlantis HILIC 150- x 2.1-mm, 3-microm column. Chromatographic separations of cocaine, seven metabolites, and anhydroecgonine were obtained by linear gradient-elution with decreasing high concentrations of acetonitrile (80-56% in 18 min). This high proportion of organic solvent makes it easier to be coupled with MS. The eluent was buffered with 2 mM ammonium acetate at pH 4.5. Except for m-hydroxy-benzoylecgonine, the within-day and between-day precisions at 20, 100, and 500 ng/mL were below 7 and 19.1%, respectively. Accuracy was also below +/- 13.5% at all tested concentrations. The limit of quantification was 5 ng/mL (%Diff < 16.1, %RSD < 4.3) and the limit of detection below 0.5 ng/mL. This method was successfully applied to a fatal overdose. In Switzerland, cocaine abuse has dramatically increased in the last few years. A 45-year-old man, a known HIV-positive drug user, was found dead at home. According to relatives, cocaine was self-injected about 10 times during the evening before death. A low amount of cocaine (0.45 mg) was detected in the bloody fluid taken from a syringe discovered near the corpse. Besides injection marks, no significant lesions were detected during the forensic autopsy. Toxicological investigations showed high cocaine concentrations in all body fluids and tissues. The peripheral blood concentrations of cocaine, benzoylecgonine, and methylecgonine were 5.0, 10.4, and 4.1 mg/L, respectively. The brain concentrations of cocaine, benzoylecgonine, and methylecgonine were 21.2, 3.8, and 3.3 mg/kg, respectively. The highest concentrations of norcocaine (about 1 mg/L) were measured in bile and urine. Very high levels of cocaine were determined in hair (160 ng/mg), indicating chronic cocaine use. A low concentration of anhydroecgonine methylester was also found in urine (0.65 mg/L) suggesting recent cocaine inhalation. Therapeutic blood concentrations of fluoxetine (0.15 mg/L) and buprenorphine (0.1 microg/L) were also discovered. A relatively high concentration of Delta(9)-THC was measured both in peripheral blood (8.2 microg/L) and brain cortex (13.5 microg/kg), suggesting that the victim was under the influence of cannabis at the time of death. In addition, fluoxetine might have enhanced the toxic effects of cocaine because of its weak pro-arrhythmogenic properties. Likewise, combination of cannabinoids and cocaine might have increase detrimental cardiovascular effects. Altogether, these results indicate a lethal cocaine overdose with a minor contribution of fluoxetine and cannabinoids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories. In order to identify possible biases, the participants were asked to use all possible activity measurement methods available in their laboratory and then to determine their reference value for comparison. Thus, measurement results from 4pibeta-gamma coincidence/anti-coincidence counting, CIEMAT/NIST liquid-scintillation counting, 4pigamma counting with well-type ionization chambers and well-type crystal detectors were given. The results are compared and show a maximum discrepancy of about 1.6%: possible explanations are proposed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In French Guiana, pyrethroids and organophosphates have been used for many years against Aedes aegypti. We aimed to establish both the resistance level of Ae. aegypti and the ultra low volume spray efficacy to provide mosquito control services with practical information to implement vector control and resistance management. Resistance to deltamethrin and fenitrothion was observed. In addition, the profound loss of efficacy of AquaK'othrine® and the moderate loss of efficacy of Paluthion® 500 were recorded. Fenitrothion remained the most effective candidate for spatial application in French Guiana until its removal in December 2010. Further investigation of the mechanism of resistance to deltamethrin demonstrated the involvement of mixed-function oxidases and, to a lesser extent, of carboxylesterases. However, these observations alone cannot explain the level of insecticide resistance we observed during tube and cage tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To estimate the incremental cost-effectiveness of the first-line pharmacotherapies (nicotine gum, patch, spray, inhaler, and bupropion) for smoking cessation across six Western countries-Canada, France, Spain, Switzerland, the United States, and the United Kingdom. DESIGN AND STUDY POPULATION: A Markov-chain cohort model to simulate two cohorts of smokers: (1) a reference cohort given brief cessation counselling by a general practitioner (GP); (2) a treatment cohort given counselling plus pharmacotherapy. Effectiveness expressed as odds ratios for quitting associated with pharmacotherapies. Costs based on the additional physician time required and retail prices of the medications. INTERVENTIONS: Addition of each first-line pharmacotherapy to GP cessation counselling. MAIN OUTCOME MEASURES: Cost per life-year saved associated with pharmacotherapies. RESULTS: The cost per life-year saved for counselling only ranged from US190 dollars in Spain to 773 dollars in the UK for men, and from 288 dollars in Spain to 1168 dollars in the UK for women. The incremental cost per life-year saved for gum ranged from 2230 dollars for men in Spain to 7643 dollars for women in the US; for patch from 1758 dollars for men in Spain to 5131 dollars for women in the UK; for spray from 1935 dollars for men in Spain to 7969 dollars for women in the US; for inhaler from 3480 dollars for men in Switzerland to 8700 dollars for women in France; and for bupropion from 792 dollars for men in Canada to 2922 dollars for women in the US. In sensitivity analysis, changes in discount rate, treatment effectiveness, and natural quit rate had the strongest influences on cost-effectiveness. CONCLUSIONS: The cost-effectiveness of the pharmacotherapies varied significantly across the six study countries, however, in each case, the results would be considered favourable as compared to other common preventive pharmacotherapies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Imaging mass spectrometry (IMS) represents an innovative tool in the cancer research pipeline, which is increasingly being used in clinical and pharmaceutical applications. The unique properties of the technique, especially the amount of data generated, make the handling of data from multiple IMS acquisitions challenging. This work presents a histology-driven IMS approach aiming to identify discriminant lipid signatures from the simultaneous mining of IMS data sets from multiple samples. The feasibility of the developed workflow is evaluated on a set of three human colorectal cancer liver metastasis (CRCLM) tissue sections. Lipid IMS on tissue sections was performed using MALDI-TOF/TOF MS in both negative and positive ionization modes after 1,5-diaminonaphthalene matrix deposition by sublimation. The combination of both positive and negative acquisition results was performed during data mining to simplify the process and interrogate a larger lipidome into a single analysis. To reduce the complexity of the IMS data sets, a sub data set was generated by randomly selecting a fixed number of spectra from a histologically defined region of interest, resulting in a 10-fold data reduction. Principal component analysis confirmed that the molecular selectivity of the regions of interest is maintained after data reduction. Partial least-squares and heat map analyses demonstrated a selective signature of the CRCLM, revealing lipids that are significantly up- and down-regulated in the tumor region. This comprehensive approach is thus of interest for defining disease signatures directly from IMS data sets by the use of combinatory data mining, opening novel routes of investigation for addressing the demands of the clinical setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

New products available for food creations include a wide variety of "supposed" food grade aerosol sprays. However, the gas propellants used cannot be considered as safe. The different legislations available did not rule any maximum residue limits, even though these compounds have some limits when used for other food purposes. This study shows a preliminary monitoring of propane, butane and dimethyl ether residues, in cakes and chocolate after spraying, when these gases are used as propellants in food aerosol sprays. Release kinetics of propane, butane and dimethyl ether were measured over one day with sprayed food, left at room temperature or in the fridge after spraying. The alkanes and dimethyl ether analyses were performed by headspace-gas chromatography-mass spectrometry/thermal conductivity detection, using monodeuterated propane and butane generated in situ as internal standards. According to the obtained results and regardingthe extrapolations of the maximum residue limits existing for these substances, different delays should be respected according to the storage conditions and the gas propellant to consume safely the sprayed food.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chagas disease control requires an innovative approach to strengthen community participation in vector surveillance. This paper presents a case study of a community-based bug-hunting campaign in Guatemala. The campaign was implemented in 2007 in the following three stages: (i) a four week preparation stage to promote bug-hunting, (ii) a one week bug-hunting stage to capture and collect bugs and (iii) a 10 week follow-up stage to analyse the bugs and spray insecticide. A total of 2,845 bugs were reported, of which 7% were Triatominae vectors, such as Rhodnius prolixus and Triatoma dimidiata. The bug-hunting campaign detected a five-six-fold higher amount of vectors in one week than traditional community-based surveillance detects in one year. The bug-hunting campaign effectively detected vectors during a short period, provided information to update the vector infestation map and increased community and political awareness regarding Chagas disease. This approach could be recommended as an effective and feasible strategy to strengthen vector surveillance on a larger scale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quantitative analyses of abscisic acid in the elongating zone of a single maize root (Zea mays L. cv LG 11) were performed by gas chromatography-mass spectrometry using negative chemical ion ionization. Data showed that the more abscisic acid, the slower the growth, but a large dispersion of individual values was observed. We assume that abscisic acid is perhaps not correlated only to the growth rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dual-channel electrospray microchip has been developed for electrospray ionization mass spectrometry (ESI-MS) where aqueous samples are mixed at the Taylor cone with an organic buffer. Due to the fast and effective mixing in the Taylor cone, the aqueous sample can be well ionized with a high ion intensity. The influence of geometric parameters such as the distance between the two microchannels at their junction at the tip of the emitter has been investigated together with chemical parameters such as the organic buffer composition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

House re-invasion by native triatomines after insecticide-based control campaigns represents a major threat for Chagas disease vector control. We conducted a longitudinal intervention study in a rural section (Area III, 407 houses) of Pampa del Indio, northeastern Argentina, and used wing geometric morphometry to compare pre-spray and post-spray (re-infestant bugs) Triatoma infestanspopulations. The community-wide spraying with pyrethroids reduced the prevalence of house infestation by T. infestans from 31.9% to < 1% during a four-year follow-up, unlike our previous studies in the neighbouring Area I. Two groups of bug collection sites differing in wing shape variables before interventions (including 221 adults from 11 domiciles) were used as a reference for assigning 44 post-spray adults. Wing shape variables from post-spray, high-density bug colonies and pre-spray groups were significantly different, suggesting that re-infestant insects had an external origin. Insects from one house differed strongly in wing shape variables from all other specimens. A further comparison between insects from both areas supported the existence of independent re-infestation processes within the same district. These results point to local heterogeneities in house re-infestation dynamics and emphasise the need to expand the geographic coverage of vector surveillance and control operations to the affected region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Els subproductes de l’ou, es presenten com a una alternativa viable a l’SDPP (Spray Dried Porcine Plasma),principalment per l’elevada qualitat de la seva proteïna, alhora que representen una fontimportant d’energia i agents antimicrobians, així com de vitamines i minerals. A més,el cost que suposa la seva inclusió en alimentació garrina és inferior al del plasma i coma element afegit, es donaria sortida a les elevades quantitats de subproductes de l’ougenerades cada any, no aptes per al consum humà

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cystic fibrosis (CF) patients with Burkholderia cepacia complex (Bcc) pulmonary infections have high morbidity and mortality. The aim of this study was to compare different methods for identification of Bcc species isolated from paediatric CF patients. Oropharyngeal swabs from children with CF were used to obtain isolates of Bcc samples to evaluate six different tests for strain identification. Conventional (CPT) and automatised (APT) phenotypic tests, polymerase chain reaction (PCR)-recA, restriction fragment length polymorphism-recA, recAsequencing, and matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) were applied. Bacterial isolates were also tested for antimicrobial susceptibility. PCR-recA analysis showed that 36 out of the 54 isolates were Bcc. Kappa index data indicated almost perfect agreement between CPT and APT, CPT and PCR-recA, and APT and PCR-recA to identify Bcc, and MALDI-TOF and recAsequencing to identify Bcc species. The recAsequencing data and the MALDI-TOF data agreed in 97.2% of the isolates. Based on recA sequencing, the most common species identified were Burkholderia cenocepacia IIIA (33.4%),Burkholderia vietnamiensis (30.6%), B. cenocepaciaIIIB (27.8%), Burkholderia multivorans (5.5%), and B. cepacia (2.7%). MALDI-TOF proved to be a useful tool for identification of Bcc species obtained from CF patients, although it was not able to identify B. cenocepacia subtypes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lactococcus garvieae is a Gram-positive, catalase negative coccus arranged in pairs or short chains, well-known as a fish pathogen. We report a case of Infective Endocarditis (IE) by L. garvieae in a native valve from a 68-year-old male with unknown history of contact with raw fish and an extensive history of heart disease. This case highlights the reliability of MALDI-TOF MS compared to conventional methods in the identification of rare microorganisms like this.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Nicotine dependence is the major obstacle for smokers who want to quit. Guidelines have identified five effective first-line therapies, four nicotine replacement therapies (NRTs)--gum, patch, nasal spray and inhaler--and bupropion. Studying the extent to which these various treatments are cost-effective requires additional research. OBJECTIVES: To determine cost-effectiveness (CE) ratios of pharmacotherapies for nicotine dependence provided by general practitioners (GPs) during routine visits as an adjunct to cessation counselling. METHODS: We used a Markov model to generate two cohorts of one-pack-a-day smokers: (1) the reference cohort received only cessation counselling from a GP during routine office visits; (2) the second cohort received the same counselling plus an offer to use a pharmacological treatment to help them quit smoking. The effectiveness of adjunctive therapy was expressed in terms of the resultant differential in mortality rate between the two cohorts. Data on the effectiveness of therapies came from meta-analyses, and we used odds ratio for quitting as the measure of effectiveness. The costs of pharmacotherapies were based on the cost of the additional time spent by GPs offering, prescribing and following-up treatment, and on the retail prices of the therapies. We used the third-party-payer perspective. Results are expressed as the incremental cost per life-year saved. RESULTS: The cost per life-year saved for only counselling ranged from Euro 385 to Euro 622 for men and from Euro 468 to Euro 796 for women. The CE ratios for the five pharmacological treatments varied from Euro 1768 to Euro 6879 for men, and from Euro 2146 to Euro 8799 for women. Significant variations in CE ratios among the five treatments were primarily due to differences in retail prices. The most cost-effective treatments were bupropion and the patch, and, then, in descending order, the spray, the inhaler and, lastly, gum. Differences in CE between men and women across treatments were due to the shape of their respective mortality curve. The lowest CE ratio in men was for the 45- to 49-year-old group and for women in the 50- to 54-year-old group. Sensitivity analysis showed that changes in treatment efficacy produced effects only for less-well proven treatments (spray, inhaler, and bupropion) and revealed a strong influence of the discount rate and natural quit rate on the CE of pharmacological treatments. CONCLUSION: The CE of first-line treatments for nicotine dependence varied widely with age and sex and was sensitive to the assumption for the natural quit rate. Bupropion and the nicotine patch were the two most cost-effective treatments.