1000 resultados para Radii of Starlikeness and Convexity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. This study aimed to assess the apical surface morphology of maxillary central incisors resected 3.0 mm from the tooth apex using Zekrya burs or Er:YAG laser, with or without subsequent direct Nd:YAG laser irradiation (apical and buccal surfaces) and indirect irradiation (palatal surface). Study design. Forty maxillary central incisors were instrumented and obturated. The roots were divided into 4 groups according to the root resection method (Zekrya bur or Er: YAG laser -1.8 W, 450 mJ, 4 Hz, 113 J/cm(2)) and further surface treatment (none or Nd: YAG laser -2.0 W, 100 mJ, 20 Hz, 124 J/cm(2)). The teeth were prepared for SEM analysis. Scores ranging from 1 to 4 were attributed to cut quality and morphological changes. The data were analyzed by the Kruskal-Wallis test and by Dunn`s test. Results. SEM images showed irregular surfaces on the apical portions resected with Zekrya burs, with smear layer and grooves in the resected dentine and slight gutta-percha displacement and plasticization. On the other hand, apicectomies carried out with Er: YAG laser showed morphological changes compatible with ablated dentine, with rough surfaces and craters. In spite of the presence of plasticized gutta-percha, with the presence of bubbles, an irregular adaptation of the filling material to the root walls was also observed. Direct Nd: YAG laser irradiation of the apical and buccal surfaces of the resected roots resulted in areas of resolidification and fusion in the dentine and cementum, with a vitrified aspect; indirect Nd: YAG laser irradiation of the palatal surfaces yielded a lower number of changes in the cementum, with irregular resolidification areas. Conclusions. There were no differences in terms of cut quality between the use of burs and Er: YAG laser or between the 2 surfaces (apical and buccal) treated with Nd: YAG laser with direct irradiation. However, morphological changes were significantly less frequent on surfaces submitted to indirect irradiation (palatal) when compared with those directly irradiated. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e77-e82)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The objective of this study was to compare the superficial morphology of bovine and human sclerotic dentine. Design: For the morphological analysis, bovine (n = 3) and human (n = 3) incisors exhibiting exposed dentine were used. Dentine presented characteristics of sclerosis: brownish, smooth and shiny-the vitreous appearance. The teeth were prepared for assessment on a scanning electron microscope (SEM). Three pre-determined areas of each sample were submitted to SEM. The number of open tubules per area was obtained from the electron micrographs (n = 9 per group) for comparison purposes. Results: The number of open tubules in both species compared were similar (p > 0.05). Human dentine presented 31.89 +/- 23.94 open tubules per area, whereas bovine dentine showed 30.33 +/- 18.14 open tubules per area. Conclusion: Based on the results, we concluded that dentine exposed at the incisal surface of human and bovine teeth presented similar clinical and micro-morphological aspects, represented by surfaces with equivalent numbers of open dentinal tubules. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tonsillar polyps are nonneoplastic lesions usually composed of variable amounts of lymphoid and vascular and connective tissues. All of them are generally assumed to be hamartomatous proliferations, but the profile of vascular and connective components has yet to be explored. The vascular system of the tonsils is complex and includes highly specialized structures (i.e., high endothelial venules (HEVs)) involved in lymphocyte homing into lymphoid tissues. In 14 tonsillar polyps and 26 control tonsils, an immunohistochemical study was performed using CD34 (blood vessels and HEVs), MECA-79 (HEVs), D2-40 (lymphatic vessels), Ki-67, collagens I and III, fibronectin, and tenascin-C. The polyps showed increased total lymphatic area, whereas the number of blood vessels and lymphatics and the blood vascular area did not differ significantly from those of control tonsils. Rare Ki-67+ endothelial cells were found. In the polyps, we detected, possibly for the first time, HEVs amid lymphoid tissue, and that the amount of the latter correlated positively with HEV density. The polyps also presented lesser amounts of fibronectin and collagens I and III than in normal tonsils, which were distributed in a disorganized fashion. Tenascin-C expression was uncommon in the polyps and control tonsils. Tonsillar polyps are composed of disorganized connective tissue and lymphatic channels which can be considered hamartomatous proliferations. However, the lymphoid component is possibly reactive due to its relationship with the HEVs. The highly differentiated phenotype of the HEVs and their complex biology are not in agreement with what would be expected for a component of hamartomatous nature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. The purpose of this research was to provide further evidence to demonstrate the precision and accuracy of maxillofacial linear and angular measurements obtained by cone-beam computed tomography (CBCT) images. Study design. The study population consisted of 15 dry human skulls that were submitted to CBCT, and 3-dimensional (3D) images were generated. Linear and angular measurements based on conventional craniometric anatomical landmarks, and were identified in 3D-CBCT images by 2 radiologists twice each independently. Subsequently, physical measurements were made by a third examiner using a digital caliper and a digital goniometer. Results. The results demonstrated no statistically significant difference between inter-and intra-examiner analysis. Regarding accuracy test, no statistically significant differences were found of the comparison between the physical and CBCT-based linear and angular measurements for both examiners (P = .968 and .915, P = .844 and .700, respectively). Conclusions. 3D-CBCT images can be used to obtain dimensionally accurate linear and angular measurements from bony maxillofacial structures and landmarks. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 430-436)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Herpesviruses may be related to the etiology of aggressive periodontitis (AgP) and chronic periodontitis (CP) by triggering periodontal destruction or by increasing the risk for bacterial infection. This case-control study evaluated the presence of herpes simplex virus type 1 (HSV-1), Epstein-Barr virus type 1 (EBV-1), human cytomegalovirus (HCMV), Aggregatibacter actinomycetemcomitans (previously Actinobacillus actinomycetemcomitans), Porphyromonas gingivalis, Prevotella intermedia, and Tannerella forsythia (previously T. forsythensis) in patients with generalized AgP (AgP group), CP (CP group), or gingivitis (G group) and in healthy individuals (C group). Methods: Subgingival plaque samples were collected with paper points from 30 patients in each group. The nested polymerase chain reaction (PCR) method was used to detect HSV-1, EBV-1, and HCMV. Bacteria were identified by 16S rRNA-based PCR. Results: HSV-1, HCMV, and EBV-1 were detected in 86.7%, 46.7%, and 33.3% of the AgP group, respectively; in 40.0%, 50.0%, and 46.7% of the CP group, respectively; in 53.3%, 40.0%, and 20.0% of the G group, respectively; and in 20.0%, 56.7%, and 0.0% of the C group, respectively. A. actinomycetemcomitans was detected significantly more often in the AgP group compared to the other groups (P<0.005). P. gingivalis and T. forsythia were identified more frequently in AgP and CP groups, and AgP, CP, and G groups had higher frequencies of P. intermedia compared to the C group. Conclusion: In Brazilian patients, HSV-1 and EBV-1, rather than HCMV, were more frequently associated with CP and AgP. J Periodontol 2008;79:2313-2321.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to determine the effect of temperature and heating rate on the densification of four leucite-based dental porcelains: two low-fusion (Dentsply Ceramco and Ivoclar) and two high-fusion commercial porcelains (Dentsply Ceramco). Porcelain powders were characterized by differential thermal analysis (DTA), X-ray diffraction (XRD), particle size distribution, helium picnometry, and by scanning electron microscopy. Test specimens were sintered from 600 to 1050 degrees C, with heating rates of 55 degrees C/min and 10 degrees C/min. The bulk density of the specimens was measured by the Archimedes method in water, and microstructures of fracture surfaces were analyzed by scanning electron microscopy (SEM). The results showed that densification of specimens increased with the increase in temperature. The increase in the heating rate had no effect on the densification of the porcelains studied. Both high-fusion materials and one of the low-fusing porcelains reached the maximum densification at a temperature that was 50 degrees C lower than that recommended by the manufactures. (C) 2011 Elsevier Ltd and Techna Group S.r.l. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. This study evaluated the effect of composite pre-polymerization temperature and energy density on the marginal adaptation (MA), degree of conversion (DC), flexural strength (FS), and polymer cross-linking (PCL) of a resin composite (Filtek Z350, 3M/ESPE). Methods. For MA, class V cavities (4mmx2mmx2mm) were prepared in 40 bovine incisors. The adhesive system Adper Single Bond 2 (3M/ESPE) was applied. Before being placed in the cavities, the resin composite was either kept at room-temperature (25 degrees C) or previously pre-heated to 68 degrees C in the Calset (TM) device (AdDent Inc., Danbury, CT, USA). The composite was then light polymerized for 20 or 40s at 600mW/cm(2) (12 or 24 J/cm(2), respectively). The percentage of gaps was analyzed by scanning electron microscopy, after sectioning the restorations and preparing epoxy resin replicas. DC (n = 3) was obtained by FT-Raman spectroscopy on irradiated and non-irradiated composite surfaces. FS (n = 10) was measured by the three-point-bending test. KHN (n = 6) was measured after 24h dry storage and again after immersion in 100% ethanol solution for 24 h, to calculate PCL density. Data were analyzed by appropriate statistical analyses. Results. The pre-heated composite showed better MA than the room-temperature groups. A higher number of gaps were observed in the room-temperature groups, irrespective of the energy density, mainly in the axial wall (p < 0.05). Composite pre-heating and energy density did not affect the DC, FS and PCL (p > 0.05). Significance. Pre-heating the composite prior to light polymerization similar in a clinical situation did not alter the mechanical properties and monomer conversion of the composite, but provided enhanced composite adaptation to cavity walls. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.