1000 resultados para Poluição orgânica


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The animal trampling favors the soil compaction process in sheep raising and crop production integrated systems. This compression has negative effects, hindering the development of roots, the availability of nutrients, water and aeration, causing production losses, making it essential for the assessment of soil physical attributes for monitoring soil quality. Soil organic matter can be used to assess the quality of the soil, due to its relationship with the chemical, physical and biological soil properties. Conservation management system with tillage, along with systems integration between crops and livestock are being used to maintain and even increase the levels of soil organic matter. For that, a field experiment was carried out over a Oxisol clayey Alic in Guarapuava, PR, from de 2006 one. experiment sheep raising and crop production integrated systems The climate classified as Cfb .. The study was to evaluate the soil physical properties and quantify the stock of soil organic carbon and its compartmentalization in system integration crop - livestock with sheep under four nitrogen rates (0, 75, 150 and 225 kg ha-1) in the winter pasture, formed by the consortium oat (Avena strigosa) and ryegrass (Lolium multiflorum) and the effect of grazing (with and without). The soil samples blades density evaluations, total porosity, macro and micro, aggregation and carbon stocks were held in two phases: Phase livestock (after removal of the animals of the area) and phase crop (after maize cultivation). The collection of soil samples were carried out in layers of 0-0.5, 0.05-0.10, 0.10-0.20 and m. Data were subjected to analysis of variance and the hypotheses tested by the F test (p <0.05). For the quantitative effect data regression and the qualitative effect used the test medium. In non-significant regressions used the average and standard deviation treatments. The animal trampling caused an increase in bulk density in the 0.10-0.20 m layer. The dose of 225 kg N ha-1 in winter pasture increased total soil porosity at 8% compared to dose 0 kg N ha-1 in the crop stage. The grazing had no effect on soil macroporosity. GMD of aggregates in the phase after grazing the surface layer was damaged by grazing. Nitrogen rates used in the winter pasture and grazing not influence the total organic carbon stocks. The TOC is not influenced by nitrogen fertilization on grassland. The grazing increases the stock of POC in the 0.10-0.20 m layer livestock phase and cause the stock of POC in the 0-0.5 m layer in the crop stage. The MAC is not influenced by N rates applied in the pasture or by grazing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação submetida à Universidade de Lisboa, Faculdade de Ciências para a obtenção do Grau de Mestre em Microbiologia Aplicada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho tem como objetivo verificar se no Brasil exista a relação da hipótese da curva ambiental de Kuznets, onde atividades que degradam o meio ambiente vão diminuindo após certo ponto de renda per capita atingido. Essa teoria será verificada através de um modelo estimado por mínimos quadrados ordinários com as variáveis de emissão de CO2 e a renda per capita e seus termos ao quadrado e ao cubo. Segundo os resultados obtidos, o Brasil ainda não apresenta este padrão de curva de Kuznets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bogotá (Colombia): Universidad de La Salle. Facultad de Ciencias Agropecuarias. Programa de Medicina Veterinaria

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Guaraíras lagoon, located in Tibau do Sul in the eastern littoral of Rio Grande do Norte (Brazil), presents a permanent connection to the sea, which guarantees the occurrence of a rich biodiversity, which includes the autochthonous shrimp species Litopenaeus schmitti, Farfantepenaeus subtilis and Farfantepenaeus brasiliensis. In spite of being subject to a strong human intervention in the last decade, mainly related to the installation of shrimp (Litopenaeus vannamei) farms, the lagoon is still scarcely studied. The present study aims at characterizing the populations of the three autochthonous penaeid shrimp species inhabiting Guaraíras, taking into consideration their abundance and seasonal distribution in the inflow channel of Primar System of Organic Aquaculture (Tibau do Sul, Rio Grande do Norte, Brazil). Twelve monthly samples were carried out from May 2005 to April 2006 with the aid of a circular cast net in the inflow channel, which is daily supplied with water from Guaraíras. Sampling months were grouped in trimesters according to the total pluviosity, thus comprising four trimesters. Water salinity was monitored twice a week and temperature values registered on a daily basis at noon, during the study period. The daily pluviosity data from the municipality of Tibau do Sul were supplied by Empresa de Pesquisa Agropecuária do Rio Grande do Norte (EMPARN). Collected shrimp were identified, weighted, measured and sexed. L. schmitti specimens (0.2 g to 17.8 g) were distributed in 1.3 g weight classes intervals. From the eighth sampling month (December 2005) onwards, males were classified into three categories, in accordance with the development of their petasm: (a) rudimentary petasm, (b) partially formed petasm, and (c) completely formed petasm. Among the ecological variables, rainfall showed the greatest dispersion (s.d.=187.74Rainfall and abundance of L. schmitti were negatively correlated (r = -0.85) whereas its abundance and water salinity were positively correlated (r = 0.63). Among 1,144 collected individuals, 1,127 were L. schmitti, 13 were F. subtilis and 4 were F. brasiliensis, which corresponded to 98.51%, 1.14% and 0.35% of the total of collected individuals. L. schmitti occurred in 100 % of all samples. Differently, the presence of F. subtilis and F. brasiliensis was restricted to 33% and 17% of the collected samples, respectively. The present study confirmed the occurrence of L. schmitti, F. brasiliensis and F. subtilis in Guaraíras. However, this lagoon seems to be primarily inhabited by juvenile Litopenaeus schmitti. The population of L. schmitti analysed showed a seasonal pattern of distribution. In general, in the months of high salinity and absence of rain, the number of individuals was higher than in the wet months. Further studies on the reproductive biology and ecology of L. schmitti, F. brasiliensis and F. subtilis may elucidate questions referring to the abundance, period, and phase of occurrence of these shrimp genera in Guaraíras. Finally, the risks associated to the establishment of L. vannamei in the lagoon provide a novel outlet for studies in this biotope

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Apesar dos avanços na sua abordagem terapêutica, a hemorragia severa continua a ser a principal causa de morbilidade e mortalidade em animais vítimas de trauma ou sujeitos a intervenção cirúrgica. O aparecimento de lesões decorrentes, ou da morte consequente, deve-se ao deficit de volume de fluidos intravasculares e subsequente desenvolvimento do estado hipovolémico. Em termos fisiológicos, a consequência mais devastadora desta condição é a diminuição, absoluta ou relativa, da pré-carga cardíaca, resultando num baixo débito cardíaco, perfusão tecidular inadequada e diminuição do aporte de oxigénio aos tecidos, o qual compromete, inequivocamente, a função celular. O controlo da hipovolémia passa pela resolução da hemorragia e pela correção do deficit de volume intravascular causado e envolve, obrigatoriamente, o recurso à administração de fluidos intravenosos. A escolha do tipo de fluido mais adequado para a terapia intravenosa, em cada ocorrência, é uma tarefa que exige reflexão e ponderação. A seleção dos fluidos apropriados é da responsabilidade do médico veterinário, sendo, no entanto, fundamental que o enfermeiro veterinário detenha conhecimentos básicos sobre as diferenças entre os fluidos disponíveis para a fluidoterapia. O objetivo deste projeto é determinar qual o tipo de fluido mais adequado para ajudar a preservar a integridade e funcionalidade hepática, em situações de hipoperfusão, e assim ajudar a padronizar a sua escolha no momento da decisão pela fluidoterapia. Para atingir este objetivo recorreu-se ao modelo suíno, a fim de recrear a situação de hipoperfusão e posteriormente avaliar os efeitos de dois fluidos diferentes administrados na reposição volémica, o lactato de Ringer e hidroxietilamido 130/0,4. Os animais foram sujeitos a uma hemorragia controlada, após a qual foi reposta a volémia com os respetivos fluidos. Após esta reposição volémica os animais foram eutanaziados e foram obtidas amostras de vários órgãos, incluindo fígado, objeto do presente estudo, alvo de diversas técnicas histopatológicas, nomeadamente o estudo histopatológico de rotina, através de hematoxilina e eosina, e diversos métodos para deteção de eventos apoptóticos, incluindo citocromo c, TUNEL e M30.Após a avaliação exaustiva dos resultados obtidos através das técnicas realizadas, foi possível concluir que o lactato de Ringer confere uma maior proteção contra a lesão de reperfusão, quando comparado com o hidroxietilamido 130/0,4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last decades, the effects of the air pollution have been increasing, especially in the case of the human health diseases. In order to overcome this problem, scientists have been studying the components of the air. As a part of water-soluble organic compounds, amino acids are present in the atmospheric environment as components of diverse living organisms which can be responsible for spreading diseases through the air. Liquid chromatography is one technique capable of distinguish the different amino acids from each other. In this work, aiming at separating the amino acids found in the aerosols samples collected in Aveiro, the ability of four columns (Mixed-Mode WAX-1, Mixed-Mode HILIC-1, Luna HILIC and Luna C18) to separate four amino acids (aspartic acid, lysine, glycine and tryptophan) and the way the interaction of the stationary phases of the columns with the analytes is influenced by organic solvent concentration and presence/concentration of the buffer, are being assessed. In the Mixed-Mode WAX-1 column, the chromatograms of the distinct amino acids revealed the separation was not efficient, since the retention times were very similar. In the case of lysine, in the elution with 80% (V/V) MeOH, the peaks appeared during the volume void. In the Mixed-Mode HILIC-1 column, the variation of the organic solvent concentration did not affect the elution of the four studied amino acids. Considering the Luna HILIC column, the retention times of the amino acids were too close to each other to ensure a separation among each other. Lastly, the Luna C18 column revealed to be useful to separate amino acids in a gradient mode, being the variation of the mobile phase composition in the organic solvent concentration (ACN). Luna C18 was the column used to separate the amino acids in the real samples and the mobile phase had acidified water and ACN. The gradient consisted in the following program: 0 – 2 min: 5% (V/V) ACN, 2 – 8 min: 5 – 2 % (V/V) ACN, 8 – 16 min: 2% (V/V) ACN, 16 – 20 min: 2 – 20 % (V/V) ACN, 20 – 35 min: 20 – 35 % (V/V) ACN. The aerosols samples were collected by using three passive samplers placed in two different locations in Aveiro and each sampler had two filters - one faced up and the other faced down. After the sampling, the water-soluble organic compounds was extracted by dissolution in ultra-pure water, sonication bath and filtration. The resulting filtered solutions were diluted in acidified water for the chromatographic separation. The results from liquid chromatography revealed the presence of the amino acids, although it was not possible to identify each one of them individually. The chromatograms and the fluorescence spectra showed the existence of some patterns: the samples that correspond to the up filters had more intense peaks and signals, revealing that the up filters collected more organic matter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Air pollution can threat the environment and public health, and is assess by pollutant ́s concentration measurements in order to verify whether the limits set by environmental agencies are being respected. However, these measures do not indicate immediately the impacts to living beings. To faced this problem, plants are been investigated as potential bioindicators of air pollution and, among them, stand out bromeliads Tillandsia genus which colonize various substrates,. obtaining water and nutrients from the atmosphere directly. In this context, this research assessed the potential of epiphytic bromeliad Tillandsia recurvata (L.) L. found in urbanized areas of the city of Curitiba - PR as a bioindicator of urban air pollution. According to vehicle traffic, five sample points were selected and classified. Points P1 and P2 were classified as high-traffic vehicle due presenting trucks and urban transport; point P3 was classified as moderate traffic due the predominance of private vehicles and urban transport; and points P4 and P5 were classified as low-traffic, presenting circulation of private vehicles only. There were analyzed the abundance of T. recurvata, morphophysiological parameters (leaf area, leaf specific area, sclerophylly index, percentage dry weight / fresh weight, chlorophyll (a + b), analysis of structural mesophyll organization) and the heavy metals accumulation (Fe, Cd, Cr, Cu, Pb and Zn). The abundance analysis and the results obtained for metals analysis were correlated with the intensity of vehicular traffic, directing the sampling points P1 > P2 = P3 > P4 = P5. This result demonstrate that the abundance of T. recurvata is greater in urban air pollution impacted areas, thus indicating that T. recurvata absorbs and accumulates metals and can be used in biomonitoring of urban air pollution in areas impacted by vehicular traffic. Morphophysiological parameters analyzed shows that the internal plant ́s structure is not significantly impacted by urban air pollution due plant ́s adptations. The presence of absorbing scales, the CAM metabolism pathway and it ́s store water ability, among other features, demonstrate their potential as bio-indicator in urban areas, especially regarding heavy metals accumulation .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente estudo analisa a associação entre partículas inaláveis (PM10) à superfície e determinadas situações meteorológicas, com base em dados (1999-2003) de concentração de partículas finas e grosseiras de estações de qualidade do ar da região de Lisboa e observações meteorológicas. Associaram-se os episódios de poluição a situações sinópticas, com base em cartas de superfície do modelo do Centro Europeu de previsão a médio prazo (ECMWF). Os episódios que ocorrem com maior frequência no Inverno estão associados a um anticiclone. Depressões de origem térmica e vales que se estendem do Norte de África ocorrem poucas vezes, mas a probabilidade de se verificar um episódio com essas situações é elevada. Para cinco destes episódios analisaram-se campos do modelo ECMWF (escala sinóptica) e do modelo ALADIN (mesoscala). As elevadas concentrações de partículas associadas aos episódios estudados resultaram de uma forte influência do nível850 hPa, corroborados pelo modelo de retro-trajectórias do KNMI. ABSTRACT; The present study analyses the relationship between particles (PM10) and specific meteorological patterns based on fine and coarse particles concentration data (1999 to 2003) from the Lisbon area air quality network and meteorological observations. Associations were established between PM10 events and synoptic patterns based on surface fields from European Centre for Medium-Range Weather Forecast (ECMWF) Model. Winter events occur mainly under high pressure conditions. Thermal lows and troughs over North Africa affecting the lberian Península occur less frequently; however, the probability of a PM event with this synoptic pattern is high. Meteorological fields from the ECMWF model (synoptic scale) and the ALADIN model (mesoscale) were analyzed for five of these episodes. The 850 hPa level is quite relevant for determining high PM10 concentrations at the surface, as confirmed by KNMI trajectory model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Art. 7.- Difusión de la Información Pública.- Por la transparencia en la gestión administrativa que están obligadas a observar todas las instituciones del Estado que conforman el sector público en los términos del artículo 225 de la Constitución de la República y demás entes señalados en el artículo 1 de la presente Ley, difundirán a través de un portal de información o página web, así como de los medios necesarios a disposición del público, implementados en la misma institución, la siguiente información mínima actualizada, que para efectos de esta Ley, se la considera de naturaleza obligatoria.