908 resultados para Left ventricular ejection fraction
Resumo:
OBJECTIVE To expand the limited information on the prognostic impact of quantitatively obtained collateral function in patients with coronary artery disease (CAD) and to estimate causality of such a relation. DESIGN Prospective cohort study with long-term observation of clinical outcome. SETTING University Hospital. PATIENTS One thousand one hundred and eighty-one patients with chronic stable CAD undergoing 1771 quantitative, coronary pressure-derived collateral flow index measurements, as obtained during a 1-min coronary balloon occlusion (CFI is the ratio between mean distal coronary occlusive pressure and mean aortic pressure both subtracted by central venous pressure). Subgroup of 152 patients included in randomised trials on the longitudinal effect of different arteriogenic protocols on CFI. INTERVENTIONS Collection of long-term follow-up information on clinical outcome. MAIN OUTCOME MEASURES All-cause mortality and major adverse cardiac events. RESULTS Cumulative 15-year survival rate was 48% in patients with CFI<0.25 and 65% in the group with CFI≥0.25 (p=0.0057). Cumulative 10-year survival rate was 75% in patients without arteriogenic therapy and 88% (p=0.0482) in the group with arteriogenic therapy and showing a significant increase in CFI at follow-up. By proportional hazard analysis, the following variables predicted increased all-cause mortality: age, low CFI, left ventricular end-diastolic pressure and number of vessels with CAD. CONCLUSIONS A well-functioning coronary collateral circulation independently predicts lowered mortality in patients with chronic CAD. This relation appears to be causal, because augmented collateral function by arteriogenic therapy is associated with prolonged survival.
Resumo:
The heart is a remarkable organ. In order to maintain its function, it remodels in response to a variety of environmental stresses, including pressure overload, volume overload, mechanical or pharmacological unloading and hormonal or metabolic disturbances. All these responses are linked to the inherent capacity of the heart to rebuild itself. Particularly, cardiac pressure overload activates signaling pathways of both protein synthesis and degradation. While much is known about regulators of protein synthesis, little is known about regulators of protein degradation in hypertrophy. The ubiquitin-proteasome system (UPS) selectively degrades unused and abnormal intracellular proteins. I speculated that the UPS may play an important role in both qualitative and quantitative changes in the composition of heart muscle during hypertrophic remodeling. My study hypothesized that cardiac remodeling in response to hypertrophic stimuli is a dynamic process that requires activation of highly regulated mechanisms of protein degradation as much as it requires protein synthesis. My first aim was to adopt a model of left ventricular hypertrophy and determine its gene expression and structural changes. Male Sprague-Dawley rats were submitted to ascending aortic banding and sacrificed at 7 and 14 days after surgery. Sham operated animals served as controls. Effective aortic banding was confirmed by hemodynamic assessment by Doppler flow measurements in vivo. Banded rats showed a four-fold increase in peak stenotic jet velocities. Histomorphometric analysis revealed a significant increase in myocyte size as well as fibrosis in the banded animals. Transcript analysis showed that banded animals had reverted to the fetal gene program. My second aim was to assess if the UPS is increased and transcriptionally regulated in hypertrophic left ventricular remodeling. Protein extracts from the left ventricles of the banded and control animals were used to perform an in vitro peptidase assay to assess the overall catalytic activity of the UPS. The results showed no difference between hypertrophied and control animals. Transcript analysis revealed decreases in transcript levels of candidate UPS genes in the hypertrophied hearts at 7 days post-banding but not at 14 days. However, protein expression analysis showed no difference at either time point compared to controls. These findings indicate that elements of the UPS are downregulated in the early phase of hypertrophic remodeling and normalizes in a later phase. The results provide evidence in support of a dynamic transcriptional regulation of a major pathway of intracellular protein degradation in the heart. The discrepancy between transcript levels on the one hand and protein levels on the other hand supports post-transcriptional regulation of the UPS pathway in the hypertrophied heart. The exact mechanisms and the functional consequences remain to be elucidated.
Resumo:
BACKGROUND: Cardiac output (CO) measurement with lithium dilution (COLD) has not been fully validated in sheep using precise ultrasonic flow probe technology (COUFP). Sheep generate important cardiovascular research models and the use of COLD has become more popular in experimental settings. METHODS: Ultrasonic transit-time perivascular flow probes were surgically implanted on the pulmonary artery of 13 sheep. Paired COLD readings were taken at six time points, before and after implantation of a left ventricular assist device (LVAD) and compared with COUFP recorded just after lithium injection. RESULTS: The mean COLD was 5.7 litre min(-1) (range 3.8-9.6 litre min(-1)) and mean COUFP 5.9 litre min(-1) (range 4.0-9.2 litre min(-1)). The bias (standard deviation) was 0.3 (1.0) litre min(-1) [5.1 (16.9)%] and limits of agreement (LOA) were -1.7 to 2.3 litre min(-1) (-28.8 to 39.0%) with a percentage error (PE) of 34.4%. Data to assess trending [rate (95% confidence intervals)] included a 78 (62-93)% concordance rate in the four-quadrant plot (n=27). In the half moon polar plot (n=19), the mean polar angle was +5°, the radial LOA were -49 to +35° and 68 (47-89)% of data points fell within 22.5° of the mean polar angle. Both tests indicated moderate to poor trending ability. CONCLUSION: COLD is not precise when evaluated against COUFP in sheep based on the statistical criteria set, but the results are comparable with previously published animal studies. KEYWORDS:
Resumo:
We appreciate the comments and concerns expressed by Arakawa and colleagues regarding our article, titled “Pulsatile control of rotary blood pumps: Does the modulation waveform matter?”1 Unfortunately, we have to disagree with Arakawa and colleagues. As is obvious from the title of our article, it investigates the effect of different waveforms on the heart–device interaction. In contrast to the authors' claim, this is the first article in the literature that uses basic waveforms (sine, triangle, saw tooth, and rectangular) with different phase shifts to examines their impact on left ventricular unloading. The previous publications2, 3 and 4 just varied the pump speed during systole and diastole, which was first reported by Bearnson and associates5 in 1996, and studied its effect on aortic pressure, coronary flow, and end-diastolic volume. We should mention that dp/dtmax is a load-sensitive parameter of contractility and not representative for the degree of unloading. Moreover, none of the aforementioned reports has studied mechanical unloading and in particular the stroke work of the left ventricle. Our method is unique because we do not just alternate between high and low speed but have accurate control of the waveform because of the direct drive system of Levitronix Technologies LLC (Waltham, Mass) and a custom-developed pump controller. Without referring, Arakawa and associates state “several previous studies have already reported the coronary flow diminishes as the left ventricular assist device support increases.” It should be noted that all the waveforms used in our study have 2000 rpm average value with 1000 rpm amplitude, which is not an excessive speed for the CentriMag rotary pump (Levitronix) to collapse the ventricle and diminish the coronary flow. We agree with Arakawa and coworkers that there is a need for a heart failure model to come to more relevant results with respect to clinical expectations. However, we have explored many existing models, including species and breeds that have a native proneness to cardiomyopathy, but all of them differ from the genetic presentation in humans. We certainly do not believe that the use of microembolization, in which the coronary circulation is impaired by the injection of microspheres, would form a good model from which to draw conclusions about coronary flow change under different loading conditions. A model would be needed in which either an infarct is created to mimic ischemic heart failure or the coronary circulation remains untouched to simulate, for instance, dilated cardiomyopathy. Furthermore, in discussion we clearly mention that “lack of heart failure is a major limitation of our study.” We also believe that unloading is not the only factor of the cardiac functional recovery, and an excessive unloading of the left ventricle might lead to cardiac tissue atrophy. Therefore, in our article we mention that control of the level of cardiac unloading by assist devices has been suggested as a mechanical tool to promote recovery, and more studies are required to find better strategies for the speed modulation of rotary pumps and to achieve an optimal heart load control to enhance myocardial recovery. Finally, there are many publications about pulsing rotary blood pumps and it was impossible to include them all. We preferred to reference some of the earlier basic works such as an original research by Bearnson and coworkers5 and another article published by our group,6 which is more relevant.
Resumo:
Cardiolipin (CL) is responsible for modulation of activities of various enzymes involved in oxidative phosphorylation. Although energy production decreases in heart failure (HF), regulation of cardiolipin during HF development is unknown. Enzymes involved in cardiac cardiolipin synthesis and remodeling were studied in spontaneously hypertensive HF (SHHF) rats, explanted hearts from human HF patients, and nonfailing Sprague Dawley (SD) rats. The biosynthetic enzymes cytidinediphosphatediacylglycerol synthetase (CDS), phosphatidylglycerolphosphate synthase (PGPS) and cardiolipin synthase (CLS) were investigated. Mitochondrial CDS activity and CDS-1 mRNA increased in HF whereas CDS-2 mRNA in SHHF and humans, not in SD rats, decreased. PGPS activity, but not mRNA, increased in SHHF. CLS activity and mRNA decreased in SHHF, but mRNA was not significantly altered in humans. Cardiolipin remodeling enzymes, monolysocardiolipin acyltransferase (MLCL AT) and tafazzin, showed variable changes during HF. MLCL AT activity increased in SHHF. Tafazzin mRNA decreased in SHHF and human HF, but not in SD rats. The gene expression of acyl-CoA: lysocardiolipin acyltransferase-1, an endoplasmic reticulum MLCL AT, remained unaltered in SHHF rats. The results provide mechanisms whereby both cardiolipin biosynthesis and remodeling are altered during HF. Increases in CDS-1, PGPS, and MLCL AT suggest compensatory mechanisms during the development of HF. Human and SD data imply that similar trends may occur in human HF, but not during nonpathological aging, consistent with previous cardiolipin studies.
Resumo:
AIMS No standardized local thrombolysis regimen exists for the treatment of pulmonary embolism (PE). We retrospectively investigated efficacy and safety of fixed low-dose ultrasound-assisted catheter-directed thrombolysis (USAT) for intermediate- and high-risk PE. METHODS AND RESULTS Fifty-two patients (65 ± 14 years) of whom 14 had high-risk PE (troponin positive in all) and 38 intermediate-risk PE (troponin positive in 91%) were treated with intravenous unfractionated heparin and USAT using 10 mg of recombinant tissue plasminogen activator per device over the course of 15 h. Bilateral USAT was performed in 83% of patients. During 3-month follow-up, two [3.8%; 95% confidence interval (CI) 0.5-13%] patients died (one from cardiogenic shock and one from recurrent PE). Major non-fatal bleeding occurred in two (3.8%; 95% CI, 0.5-13%) patients: one intrathoracic bleeding after cardiopulmonary resuscitation requiring transfusion, one intrapulmonary bleeding requiring lobectomy. Mean pulmonary artery pressure decreased from 37 ± 9 mmHg at baseline to 25 ± 8 mmHg at 15 h (P < 0.001) and cardiac index increased from 2.0 ± 0.7 to 2.7 ± 0.9 L/min/m(2) (P < 0.001). Echocardiographic right-to-left ventricular end-diastolic dimension ratio decreased from 1.42 ± 0.21 at baseline to 1.06 ± 0.23 at 24 h (n = 21; P < 0.001). The greatest haemodynamic benefit from USAT was found in patients with high-risk PE and in those with symptom duration < 14 days. CONCLUSION A standardized catheter intervention approach using fixed low-dose USAT for the treatment of intermediate- and high-risk PE was associated with rapid improvement in haemodynamic parameters and low rates of bleeding complications and mortality.
Resumo:
Recently developed technologies allow aortic valve implantation off-pump in a beating heart. In this procedure, the native, stenotic aortic valve is not removed, but simply crushed by a pressure balloon mounted on a percutaneous catheter. Removal of the native aortic cusps before valve replacement may reduce the incidence of annular or cuspal calcium embolization and late perivalvular leaks and increase implantable valve size. However, a temporary valve system in the ascending aorta may be necessary to maintain hemodynamic stability by reducing acute aortic regurgitation and left ventricular volume overload. This study evaluates the hemodynamic effects of a wire-mounted, monoleaflet, temporary valve apparatus in a mechanical cardiovascular simulator. Aortic flow, systemic pressure and left ventricular pressure were continuously monitored. An intraluminal camera obtained real-time proximal and distal images of the valve in operation. Insertion of the parachute valve in the simulator increased diastolic pressure from 7 to 38 mm Hg. Cardiac output increased from 2.08 to 4.66 L/min and regurgitant volume decreased from 65 to 23 mL. In conclusion, placement of a temporary valve in the ascending aorta may help maintain hemodynamic stability and improve off-pump aortic valve replacement.
Resumo:
BACKGROUND In patients with acute pulmonary embolism, systemic thrombolysis improves right ventricular (RV) dilatation, is associated with major bleeding, and is withheld in many patients at risk. This multicenter randomized, controlled trial investigated whether ultrasound-assisted catheter-directed thrombolysis (USAT) is superior to anticoagulation alone in the reversal of RV dilatation in intermediate-risk patients. METHODS AND RESULTS Fifty-nine patients (63±14 years) with acute main or lower lobe pulmonary embolism and echocardiographic RV to left ventricular dimension (RV/LV) ratio ≥1.0 were randomized to receive unfractionated heparin and an USAT regimen of 10 to 20 mg recombinant tissue plasminogen activator over 15 hours (n=30; USAT group) or unfractionated heparin alone (n=29; heparin group). Primary outcome was the difference in the RV/LV ratio from baseline to 24 hours. Safety outcomes included death, major and minor bleeding, and recurrent venous thromboembolism at 90 days. In the USAT group, the mean RV/LV ratio was reduced from 1.28±0.19 at baseline to 0.99±0.17 at 24 hours (P<0.001); in the heparin group, mean RV/LV ratios were 1.20±0.14 and 1.17±0.20, respectively (P=0.31). The mean decrease in RV/LV ratio from baseline to 24 hours was 0.30±0.20 versus 0.03±0.16 (P<0.001), respectively. At 90 days, there was 1 death (in the heparin group), no major bleeding, 4 minor bleeding episodes (3 in the USAT group and 1 in the heparin group; P=0.61), and no recurrent venous thromboembolism. CONCLUSIONS In patients with pulmonary embolism at intermediate risk, a standardized USAT regimen was superior to anticoagulation with heparin alone in reversing RV dilatation at 24 hours, without an increase in bleeding complications. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01166997.
Resumo:
Introduction The aim of this study was to determine which single measurement on post-mortem cardiac MR reflects actual heart weight as measured at autopsy, assess the intra- and inter-observer reliability of MR measurements, derive a formula to predict heart weight from MR measurements and test the accuracy of the formula to prospectively predict heart weight. Materials and methods 53 human cadavers underwent post-mortem cardiac MR and forensic autopsy. In Phase 1, left ventricular area and wall thickness were measured on short axis and four chamber view images of 29 cases. All measurements were correlated to heart weight at autopsy using linear regression analysis. In Phase 2, single left ventricular area measurements on four chamber view images (LVA_4C) from 24 cases were used to predict heart weight at autopsy based on equations derived during Phase 1. Intra-class correlation coefficient (ICC) was used to determine inter- and intra-reader agreement. Results Heart weight strongly correlates with LVA_4C (r=0.78 M; p<0.001). Intra-reader and inter-reader reliability was excellent for LVA_4C (ICC=0.81–0.91; p<0.001 and ICC=0.90; p<0.001 respectively). A simplified formula for heart weight ([g]≈LVA_4C [mm2]×0.11) was derived based on linear regression analysis. Conclusions This study shows that single circumferential area measurements of the left ventricle in the four chamber view on post-mortem cardiac MR reflect actual heart weight as measured at autopsy. These measurements yield an excellent intra- and inter-reader reliability and can be used to predict heart weight prior to autopsy or to give a reasonable estimate of heart weight in cases where autopsy is not performed.
Resumo:
INTRODUCTION Hemodynamic management in intensive care patients guided by blood pressure and flow measurements often do not sufficiently reveal common hemodynamic problems. Trans-esophageal echocardiography (TEE) allows for direct measurement of cardiac volumes and function. A new miniaturized probe for TEE (mTEE) potentially provides a rapid and simplified approach to monitor cardiac function. The aim of the study was to assess the feasibility of hemodynamic monitoring using mTEE in critically ill patients after a brief operator training period. METHODS In the context of the introduction of mTEE in a large ICU, 14 ICU staff specialists with no previous TEE experience received six hours of training as mTEE operators. The feasibility of mTEE and the quality of the obtained hemodynamic information were assessed. Three standard views were acquired in hemodynamically unstable patients: 1) for assessment of left ventricular function (LV) fractional area change (FAC) was obtained from a trans-gastric mid-esophageal short axis view, 2) right ventricular (RV) size was obtained from mid-esophageal four chamber view, and 3) superior vena cava collapsibility for detection of hypovolemia was assessed from mid-esophageal ascending aortic short axis view. Off-line blinded assessment by an expert cardiologist was considered as a reference. Inter-rater agreement was assessed using Chi-square tests or correlation analysis as appropriate. RESULTS In 55 patients, 148 mTEE examinations were performed. Acquisition of loops in sufficient quality was possible in 110 examinations for trans-gastric mid-esophageal short axis, 118 examinations for mid-esophageal four chamber and 125 examinations for mid-esophageal ascending aortic short axis view. Inter-rater agreement (Kappa) between ICU mTEE operators and the reference was 0.62 for estimates of LV function, 0.65 for RV dilatation, 0.76 for hypovolemia and 0.77 for occurrence of pericardial effusion (all P < 0.0001). There was a significant correlation between the FAC measured by ICU operators and the reference (r = 0.794, P (one-tailed) < 0.0001). CONCLUSIONS Echocardiographic examinations using mTEE after brief bed-side training were feasible and of sufficient quality in a majority of examined ICU patients with good inter-rater reliability between mTEE operators and an expert cardiologist. Further studies are required to assess the impact of hemodynamic monitoring by mTEE on relevant patient outcomes.
Resumo:
Aldosterone plays an important role in the pathophysiology of heart failure. Aldosterone receptor blockade has been shown to reduce morbidity and mortality in human patients with advanced congestive left ventricular heart failure. This study was designed to assess the efficacy and tolerance of long-term low-dose spironolactone when added to conventional heart failure treatment in dogs with advanced heart failure. Eighteen client-owned dogs with advanced congestive heart failure due to either degenerative valve disease (n=11) or dilated cardiomyopathy (n=7) were included in this prospective, placebo-controlled, double-blinded, randomized clinical study. After initial stabilization including furosemide, angiotensin-converting enzyme inhibitors, pimobendan and digoxin, spironolactone at a median dose of 0.52 mg/kg (range 0.49-0.8 mg/kg) once daily (n=9) or placebo (n=9) was added to the treatment, and the dogs were reassessed 3 and 6 months later. Clinical scoring, echocardiography, electrocardiogram, systolic blood pressure measurement, thoracic radiography, sodium, potassium, urea, creatinine, alanine aminotransferase, aldosterone and aminoterminal atrial natriuretic propeptide were assessed at baseline, 3 and 6 months. Survival times were not significantly different between the two treatment groups. Spironolactone was well tolerated when combined with conventional heart failure treatment.
Resumo:
OBJECTIVES To investigate and correct the temperature dependence of postmortem MR quantification used for soft tissue characterization and differentiation in thoraco-abdominal organs. MATERIAL AND METHODS Thirty-five postmortem short axis cardiac 3-T MR examinations were quantified using a quantification sequence. Liver, spleen, left ventricular myocardium, pectoralis muscle and subcutaneous fat were analysed in cardiac short axis images to obtain mean T1, T2 and PD tissue values. The core body temperature was measured using a rectally inserted thermometer. The tissue-specific quantitative values were related to the body core temperature. Equations to correct for temperature differences were generated. RESULTS In a 3D plot comprising the combined data of T1, T2 and PD, different organs/tissues could be well differentiated from each other. The quantitative values were influenced by the temperature. T1 in particular exhibited strong temperature dependence. The correction of quantitative values to a temperature of 37 °C resulted in better tissue discrimination. CONCLUSION Postmortem MR quantification is feasible for soft tissue discrimination and characterization of thoraco-abdominal organs. This provides a base for computer-aided diagnosis and detection of tissue lesions. The temperature dependence of the T1 values challenges postmortem MR quantification. Equations to correct for the temperature dependence are provided. KEY POINTS • Postmortem MR quantification is feasible for soft tissue discrimination and characterization • Temperature dependence of the T1 values challenges the MR quantification approach • The results provide the basis for computer-aided postmortem MRI diagnosis • Diagnostic criteria may also be applied for living patients.
Resumo:
Cardiac tissue engineering approaches can deliver large numbers of cells to the damaged myocardium and have thus increasingly been considered as a possible curative treatment to counteract the high prevalence of progressive heart failure after myocardial infarction (MI). Optimal scaffold architecture and mechanical and chemical properties, as well as immune- and bio-compatibility, need to be addressed. We demonstrated that radio-frequency plasma surface functionalized electrospun poly(ɛ-caprolactone) (PCL) fibres provide a suitable matrix for bone-marrow-derived mesenchymal stem cell (MSC) cardiac implantation. Using a rat model of chronic MI, we showed that MSC-seeded plasma-coated PCL grafts stabilized cardiac function and attenuated dilatation. Significant relative decreases of 13% of the ejection fraction (EF) and 15% of the fractional shortening (FS) were observed in sham treated animals; respective decreases of 20% and 25% were measured 4 weeks after acellular patch implantation, whereas a steadied function was observed 4 weeks after MSC-patch implantation (relative decreases of 6% for both EF and FS).
Resumo:
The Barostim neo ™ system is a novel implantable device that activates the carotid baroreflex. It decreases the sympathetic activity and inhibits the renin system, which results in reduced blood pressure and heart rate. In patients with resistant hypertension, electrically activation of the baroreflex leads to an average decrease in systolic blood pressure of 38, 36, 40 and 53 mmHg at 1, 2, 3 and 4 years, respectively. Additionally, cardiac remodelling with reduced left ventricular mass and posterior wall thickness has been observed in long-term studies. In a limited number of patients with heart failure, baroreflex activation therapy leads to a decrease in muscle sympathetic nerve activity and to improved quality of life and functional capacities. The implantation procedure is safe and associated with risks comparable with those of other active implantable devices. Barostim neo is currently available in several European countries.
Resumo:
Transcatheter aortic valve implantation is a feasible therapeutic option for selected patients with severe aortic stenosis and high or prohibitive risk for standard surgery. Lung transplant recipients are often considered high-risk patients for heart surgery because of their specific transplant-associated characteristics and comorbidities. We report a case of successful transfemoral transcatheter aortic valve replacement in a lung transplant recipient with a symptomatic severe aortic stenosis, severe left ventricular dysfunction, and end-stage renal failure 9 years after bilateral lung transplantation.