972 resultados para Corrective Switching


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ethernet is becoming the dominant aggregation technology for carrier transport networks; however, as it is a LAN technology, native bridged ethernet does not fulfill all the carrier requirements. One of the schemes proposed by the research community to make ethernet fulfill carrier requirements is ethernet VLAN-label switching (ELS). ELS allows the creation of label switched data paths using a 12-bit label encoded in the VLAN TAG control information field. Previous label switching technologies such as MPLS use more bits for encoding the label. Hence, they do not suffer from label sparsity issues as ELS might. This paper studies the sparsity issues resulting from the reduced ELS VLAN-label space and proposes the use of the label merging technique to improve label space usage. Experimental results show that label merging considerably improves label space usage

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the context of autonomous sensors powered by small-size photovoltaic (PV) panels, this work analyses how the efficiency of DC/DC-converter-based power processing circuits can be improved by an appropriate selection of the inductor current that transfers the energy from the PV panel to a storage unit. Each component of power losses (fixed, conduction and switching losses) involved in the DC/DC converter specifically depends on the average inductor current so that there is an optimal value of this current that causes minimal losses and, hence, maximum efficiency. Such an idea has been tested experimentally using two commercial DC/DC converters whose average inductor current is adjustable. Experimental results show that the efficiency can be improved up to 12% by selecting an optimal value of that current, which is around 300-350 mA for such DC/DC converters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Metsäteollisuudessa henkilöstön keski-ikä on monen muun toimialan tavoin noussut merkittävästi viime vuosina. Samaan aikaan työt ovat monipuolistuneet, ja henkilöstöä on vähennetty kustannustehokkuuden nimissä. Osittain näiden tekijöiden seurauksena sairauspoissaolot ovat nousseet, ja niiden aiheuttamat kustannukset ovat vuosittain hyvin merkittävät. Lisäksi työkyvyttömyys- ja tapaturmaeläköitymisten kustannukset ovat keskimäärin nousseet uuden maksuluokkajärjestelmän käyttöönoton myötä. Sairauspoissaolojen alentamisen ja eläköitymisten ehkäisemiseksi on vuosien varrella hyödynnetty erilaisia käytäntöjä ja toimintamalleja, joiden vaikutusalueet vaihtelevat työturvallisuudesta työhönpaluun tukemiseen. Erilaisia uudelleensijoituksia ja työtehtävien räätälöintejä on mahdollisuuksien mukaan pyritty toteuttamaan, mutta näiden esteenä on pääosin ollut yhteistyön ja tiedon puute, haastava ajankohta, sekä erilaiset negatiiviset asenteet. Kuntouttavalla työllä tarkoitetaan eri osapuolten kanssa yhdessä sovittua, määräaikaista ja normaalista poikkeavaa toimintaa, jolla pyritään vähentämään osatyökykyisen työntekijän pitkiä poissaoloja sekä poistamaan mahdollinen varhaisen eläköitymisen uhka. Tämän tutkimuksen aikana kehitetyn kuntouttavan työn uuden toimintamallin tavoitteena on edelleen lisätä tietoisuutta ja yhteistyötä eri osapuolten välillä sekä vaikuttaa omalta osaltaan työnantajan sairauspoissaolojen ja eläköitymisten aiheuttamiin kustannuksiin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes the use of an autonomous assistant mobile robot in order to monitor the environmental conditions of a large indoor area and develop an ambient intelligence application. The mobile robot uses single high performance embedded sensors in order to collect and geo-reference environmental information such as ambient temperature, air velocity and orientation and gas concentration. The data collected with the assistant mobile robot is analyzed in order to detect unusual measurements or discrepancies and develop focused corrective ambient actions. This paper shows an example of the measurements performed in a research facility which have enabled the detection and location of an uncomfortable temperature profile inside an office of the research facility. The ambient intelligent application has been developed by performing some localized ambient measurements that have been analyzed in order to propose some ambient actuations to correct the uncomfortable temperature profile.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El treball presentat ve motivat per la necessitat d’instal•lació d’un pàrquing públic i privat de nova construcció a nivell d’il•luminació i ventilació. Per poder satisfer les necessitats del nostre client d’estalvi energètic i confort en l’edifici es decideix d’implementar una instal•lació immòtica que és l’aplicació de tècniques de gestió i control automatitzat a un edifici terciari amb bus de comunicació KNX/EIB. Per a la il•luminació s’han utilitzat fluorescents amb balasts DALI, que permeten la seva regulació i control, per així poder adequar en tot moment l’encesa i intensitat de llum d’aquests. En quant a la ventilació s’han utilitzat variadors de freqüència per també poder optimitzar el funcionament dels ventiladors podent posar-los en marxa quan realment sigui necessari i a la potència que calgui. Per enllaçar tots els elements de la instal•lació, detectors i actuadors, sorgeig la necessitat d’implementar xarxes de comunicació com el KNX/EIB, DALI, Modbus i Ethernet. Per gestionar variables, comunicacions i controlar elements, s´hi han implementen dos autòmats programables a més d’un PC integrat per la visualització i el control del pàrquing. S’ha aconseguit de realitzar un pàrquing totalment automàtic on no és necessaria l’actuació dels operaris i amb les principals càrregues elèctriques totalment regulables en potència. S’ha comprovat que la instal•lació funciona per sota de la potència nominal de les càrregues amb l’estalvi energètic que això suposa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An oscillating overvoltage has become a common phenomenon at the motor terminal in inverter-fed variable-speed drives. The problem has emerged since modern insulated gate bipolar transistors have become the standard choice as the power switch component in lowvoltage frequency converter drives. Theovervoltage phenomenon is a consequence of the pulse shape of inverter output voltage and impedance mismatches between the inverter, motor cable, and motor. The overvoltages are harmful to the electric motor, and may cause, for instance, insulation failure in the motor. Several methods have been developed to mitigate the problem. However, most of them are based on filtering with lossy passive components, the drawbacks of which are typically their cost and size. In this doctoral dissertation, application of a new active du/dt filtering method based on a low-loss LC circuit and active control to eliminate the motor overvoltages is discussed. The main benefits of the method are the controllability of the output voltage du/dt within certain limits, considerably smaller inductances in the filter circuit resulting in a smaller physical component size, and excellent filtering performance when compared with typical traditional du/dt filtering solutions. Moreover, no additional components are required, since the active control of the filter circuit takes place in the process of the upper-level PWM modulation using the same power switches as the inverter output stage. Further, the active du/dt method will benefit from the development of semiconductor power switch modules, as new technologies and materials emerge, because the method requires additional switching in the output stage of the inverter and generation of narrow voltage pulses. Since additional switching is required in the output stage, additional losses are generated in the inverter as a result of the application of the method. Considerations on the application of the active du/dt filtering method in electric drives are presented together with experimental data in order to verify the potential of the method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mineral waste studied was host rock from a chromite mine located in Andorinha/Bahia, extracted and stockpiled in yards without specific application. Host rock was submitted to chemical analysis, XRD, SEM-EDS, IR and TGA and classified according to ABNT standards for solid waste classification. Analyses confirmed that this host rock, classified as ultrabasic, consists mainly of dolomite, calcite and diopside. Hazard assessment results showed this host rock should be classified as class II B - inert waste, important for its potential application in agriculture as a soil acidity correction agent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the use of the open source hardware platform, denominated "Arduino", for controlling solenoid valves for solutions handling in flow analysis systems. System assessment was carried out by spectrophotometric determination of iron (II) in natural water. The sampling rate was estimated as 45 determinations per hour and the coefficient of variation was lower than 3%. Per determination, 208 µg of 1-10-phenanthroline and ascorbic acid were consumed, generating 1.3 mL of waste. "Arduino" proved a reliable microcontroller with low cost and simple interfacing, allowing USB communication for solenoid device switching in flow systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AbstractA device comprising a lab-made chamber with mechanical stirring and computer-controlled solenoid valves is proposed for the mechanization of liquid-liquid extractions. The performance was demonstrated by the extraction of ethanol from biodiesel as a model of the extraction of analytes from organic immiscible samples to an aqueous medium. The volumes of the sample and extractant were precisely defined by the flow-rates and switching times of the valves, while the mechanic stirring increased interaction between the phases. Stirring was stopped for phase separation, and a precise time-control also allowed a successful phase separation (i.e., the absence of the organic phase in the aqueous extract). In the model system, a linear response between the analytical response and the number of extractions was observed, indicating the potential for analyte preconcentration in the extract. The efficiency and reproducibility of the extractions were demonstrated by recoveries of ethanol spiked to biodiesel samples within 96% and 100% with coefficients of variation lower than 3.0%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this thesis is to investigate the thermal loading of medium voltage three-level NPC inverter’s semiconductor IGCT switches in different operation points. The objective is to reach both a fairly accurate off-line simulation program and also so simple a simulation model that its implementation into an embedded system could be reasonable in practice and a real time use should become feasible. Active loading limitation of the inverter can be realized with a thermal model which is practical in a real time use. Determining of the component heating has been divided into two parts; defining of component losses and establishing the structure of a thermal network. Basics of both parts are clarified. The simulation environment is Matlab-Simulink. Two different models are constructed – a more accurate one and a simplified one. Potential simplifications are clarified with the help of the first one. Simplifications are included in the latter model and the functionalities of both models are compared. When increasing the calculation time step a decreased number of considered components and time constants of the thermal network can be used in the simplified model. Heating of a switching component is dependent on its topological position and inverter’s operation point. The output frequency of the converter defines mainly which one of the switching components is – because of its losses and heating – the performance limiting component of the converter. Comparison of results given by different thermal models demonstrates that with larger time steps, describing of fast occurring switching losses becomes difficult. Generally articles and papers dealing with this subject are written for two-level inverters. Also inverters which apply direct torque control (DTC) are investigated rarely from the heating point of view. Hence, this thesis completes the former material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multilevel converters provide an attractive solution to bring the benefits of speed-controlled rotational movement to high-power applications. Therefore, multilevel inverters have attracted wide interest in both the academic community and in the industry for the past two decades. In this doctoral thesis, modulation methods suitable especially for series connected H-bridge multilevel inverters are discussed. A concept of duty cycle modulation is presented and its modification is proposed. These methods are compared with other well-known modulation schemes, such as space-vector pulse width modulation and carrier-based modulation schemes. The advantage of the modified duty-cycle modulation is its algorithmic simplicity. A similar mathematical formulation for the original duty cycle modulation is proposed. The modified duty cycle modulation is shown to produce well-formed phase-to-neutral voltages that have lower total harmonic distortion than the space-vector pulse width modulation and the duty cycle modulation. The space-vector-based solution and the duty cycle modulation, on the other hand, result in a better-quality line-to-line voltage and current waveform. The voltage of the DC links in the modules of the series-connected H-bridge inverter are shown to fluctuate while they are under load. The fluctuation causes inaccuracies in the voltage production, which may result in a failure of the flux estimator in the controller. An extension for upper-level modulation schemes, which changes the switching instants of the inverter so that the output voltage meets the reference voltage accurately regardless of the DC link voltages, is proposed. The method is shown to reduce the error to a very low level when a sufficient switching frequency is used. An appropriate way to organize the switching instants of the multilevel inverter is to make only one-level steps at a time. This causes restrictions on the dynamical features of the modulation schemes. The produced voltage vector cannot be rotated several tens of degrees in a single switching period without violating the above-mentioned one-level-step rule. The dynamical capabilities of multilevel inverters are analyzed in this doctoral thesis, and it is shown that the multilevel inverters are capable of operating even in dynamically demanding metal industry applications. In addition to the discussion on modulation schemes, an overvoltage in multilevel converter drives caused by cable reflection is addressed. The voltage reflection phenomenon in drives with long feeder cables causes premature insulation deterioration and also affects the commonmode voltage, which is one of the main reasons for bearing currents. Bearing currents, on the other hand, cause fluting in the bearings, which results in premature bearing failure. The reflection phenomenon is traditionally prevented by filtering, but in this thesis, a modulationbased filterless method to mitigate the overvoltage in multilevel drives is proposed. Moreover, the mitigation method can be implemented as an extension for upper-level modulation schemes. The method exploits the oscillations caused by two consecutive voltage edges so that the sum of the oscillations results in a mitigated peak of the overvoltage. The applicability of the method is verified by simulations together with experiments with a full-scale prototype.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The maximum realizable power throughput of power electronic converters may be limited or constrained by technical or economical considerations. One solution to this problemis to connect several power converter units in parallel. The parallel connection can be used to increase the current carrying capacity of the overall system beyond the ratings of individual power converter units. Thus, it is possible to use several lower-power converter units, produced in large quantities, as building blocks to construct high-power converters in a modular manner. High-power converters realized by using parallel connection are needed for example in multimegawatt wind power generation systems. Parallel connection of power converter units is also required in emerging applications such as photovoltaic and fuel cell power conversion. The parallel operation of power converter units is not, however, problem free. This is because parallel-operating units are subject to overcurrent stresses, which are caused by unequal load current sharing or currents that flow between the units. Commonly, the term ’circulatingcurrent’ is used to describe both the unequal load current sharing and the currents flowing between the units. Circulating currents, again, are caused by component tolerances and asynchronous operation of the parallel units. Parallel-operating units are also subject to stresses caused by unequal thermal stress distribution. Both of these problemscan, nevertheless, be handled with a proper circulating current control. To design an effective circulating current control system, we need information about circulating current dynamics. The dynamics of the circulating currents can be investigated by developing appropriate mathematical models. In this dissertation, circulating current models aredeveloped for two different types of parallel two-level three-phase inverter configurations. Themodels, which are developed for an arbitrary number of parallel units, provide a framework for analyzing circulating current generation mechanisms and developing circulating current control systems. In addition to developing circulating current models, modulation of parallel inverters is considered. It is illustrated that depending on the parallel inverter configuration and the modulation method applied, common-mode circulating currents may be excited as a consequence of the differential-mode circulating current control. To prevent the common-mode circulating currents that are caused by the modulation, a dual modulator method is introduced. The dual modulator basically consists of two independently operating modulators, the outputs of which eventually constitute the switching commands of the inverter. The two independently operating modulators are referred to as primary and secondary modulators. In its intended usage, the same voltage vector is fed to the primary modulators of each parallel unit, and the inputs of the secondary modulators are obtained from the circulating current controllers. To ensure that voltage commands obtained from the circulating current controllers are realizable, it must be guaranteed that the inverter is not driven into saturation by the primary modulator. The inverter saturation can be prevented by limiting the inputs of the primary and secondary modulators. Because of this, also a limitation algorithm is proposed. The operation of both the proposed dual modulator and the limitation algorithm is verified experimentally.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A coupled system simulator, based on analytical circuit equations and a finite element method (FEM) model of the motor has been developed and it is used to analyse a frequency-converterfed industrial squirrel-cage induction motor. Two control systems that emulate the behaviour of commercial direct-torque-controlled (DTC) and vector-controlled industrial frequency converters have been studied, implemented in the simulation software and verified by extensive laboratory tests. Numerous factors that affect the operation of a variable speed drive (VSD) and its energy efficiency have been investigated, and their significance in the simulation of the VSD results has been studied. The dependency of the frequency converter, induction motor and system losses on the switching frequency is investigated by simulations and measurements at different speeds for both the vector control and the DTC. Intensive laboratory measurements have been carried out to verify the simulation results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

B lymphocytes constitute a key branch of adaptive immunity by providing specificity to recognize a vast variety of antigens by B cell antigen receptors (BCR) and secreted antibodies. Antigen recognition activates the cells and can produce antibody secreting plasma cells via germinal center reaction that leads to the maturation of antigen recognition affinity and switching of antibody effector class. The specificity of antigen recognition is achieved through a multistep developmental pathway that is organized by interplay of transcription factors and signals through BCR. Lymphoid malignancies arise from different stages of development in abnormal function of transcriptional regulation. To understand the B cell development and the function of B cells, a thorough understanding of the regulation of gene expression is important. The transcription factors of the Ikaros family and Bcl6 are frequently associated with lymphoma generation. The aim of this study was to reveal the targets of Ikaros, Helios and Bcl6 mediated gene regulation and to find out the function of Ikaros and Helios in B cells. This study uses gene targeted DT40 B cell lines and establishes a role for Ikaros family factors Ikaros and Helios in the regulation of BCR signaling that is important at developmental checkpoints, for cell survival and in activation. Ikaros and Helios had opposing roles in the regulation of BCR signals. Ikaros was found to directly repress the SHIP gene that encodes a signaling lipid-metabolizing enzyme, whereas Helios had activating effect on SHIP expression. The findings demonstrate a balancing function for these two Ikaros family transcription factors in the regulation of BCR signaling as well as in the regulation of gene expression. Bcl6 was found to repress plasma cell gene expression program while maintaining gene expression profile of B cells. Analysis of direct Bcl6 target genes suggested novel mechanisms for Bcl6-mediated suppression of plasma cell differentiation and promoting germinal center phenotype.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tutkimuksen päämääränä oli selvittää laadullisin menetelmin millaisia kustannusvaikutuksia laajavaikutteiset palvelutasopoikkeamat, eli erilaiset viat tai häiriöt tietoliikennepalveluissa aiheuttavat kohdeyrityksen tietoliikennepalveluiden tuotannossa. Tutkimus muistutti lähtökohdiltaan paljolti riskianalyysia, sillä sen tavoitteina oli tunnistaa merkittävimmät palvelutasopoikkeamien aiheuttajat, arvioida palvelutasopoikkeaman kustannusvaikutuksia ja pohtia millaisin toimin ja kustannuksin palvelutasopoikkeamia voitaisiin ehkäistä. Tutkimusongelmaa lähestyttiin jakamalla palvelutasopoikkeaman kustannusvaikutukset viankorjauksesta aiheutuviin välittömiin ja asiakasvaikutusten kautta mahdollisesti syntyviin välillisiin kustannuksiin. Välillisiä kustannuksia aiheuttaviksi ilmiöiksi tunnistettiin palvelukatkon aiheuttama liikennetulomenetys, nykyisten tai potentiaalisten asiakkaiden menettäminen ja nykyisten asiakkaiden alentunut ostohalukkuus. Yhteenvetona tutkimuksessa tehtyihin havaintoihin perustuen välilliset kustannukset eivät osoittautuneet niin merkittäviksi kuin tutkimuksen aloitusvaiheessa oletettiin, mutta lisätutkimus aiheesta voi olla perusteltua.