968 resultados para Behavior modification techniques


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of hands in the transmission of nosocomial infection has been world wide admitted. However, it is difficult to induce this behavior in health-care workers. The aim of the present work was to point out the importance of hand bacteria colonization, the influence of hand washing and of patient physical examination. One hundred health-care workers were randomly divided in two groups: Group A without hand washing previous to patient physical examination or handling (PPE); group B with hand washing previous to PPE. Direct fingerprint samples in Columbia agar before and after PPE were obtained. The colonies were counted and identified by conventional techniques, and antibiograms according to NCCLS were performed. Before PPE group A participants showed a high number of bacteria regarding group B participants (73.9 Vs 20.7; p < 0.001); 44 out of 50 participants were carriers of potentially pathogen bacteria. No group B participants were carriers of potential pathogen bacteria before PPE. The latter group showed an increase in number of bacteria after PPE (20.7 CFU (before) Vs 115.9 CFU (after); p < 0.001). Sixteen group B participants were contaminated after PPE with potential pathogens such as S. aureus (50% of them meticillin resistant); Escherichia coli, Pseudomonas aeruginosa and Enterococcus faecalis, half of them multiresistant. We can conclude on the importance of these results to implement educational programs and to provide the health-care workers with the proper commodities to fulfill this practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Para garantir que um equipamento opere com segurança e fiabilidade durante o seu ciclo de vida, desde a sua instalação ao desmantelamento, devem ser realizadas inspeções e/ou monitorizações que, dependendo dos dados recolhidos, podem implicar avaliações Fitness- For-Service (FFS) que definirão a necessidade de reparação ou alteração do equipamento ou das condições processuais. A combinação de inspeção ou monitorização com os melhores procedimentos e técnicas de avaliação atuais fazem sobressair insuficiências dos procedimentos mais antigos. Usando métodos mais avançados de avaliação, validados e suportados através de uma vasta experiência de campo, pode-se agora avaliar defeitos nos ativos (equipamentos) e determinar a adequação ao serviço com uma análise FFS. As análises FFS tornaram-se cada vez mais aceites em toda a indústria ao longo dos últimos anos. A norma API 579 - 1/ASME FFS-1: 2007 fornece diretrizes para avaliar os tipos de danos que afetam os equipamentos processuais e a norma API RP 571: 2011 descreve os mecanismos de degradação que afetam os equipamentos nas petroquímicas e refinarias, que incluem os danos por corrosão, desalinhamentos, deformações plásticas, laminações, fissuras, entre outros. Este trabalho consiste na análise de Integridade Estrutural de uma Flare Industrial que surgiu da necessidade real de análise do equipamento no âmbito da atividade profissional do candidato. O estudo realizado a nível profissional é de grande abrangência, incluindo a inspeção do equipamento, identificação da falha ou dano, recolha e registo de dados, definição de estratégia de atuação e seleção de técnicas de avaliação da condição para posterior alteração, reparação ou desmantelamento. Na presente dissertação de mestrado em Engenharia Mecânica, Ramo Construções Mecânicas, pretende-se efetuar o estudo aprofundado de uma das etapas de projeto, nomeadamente estudar a causa, avaliar a falha e implicações estruturais ou processuais devido à degradação interior do riser de uma flare, com base numa análise FFS, assumindo a operabilidade em segurança e garantindo resolutas condições de funcionamento. A presente análise FFS tem como finalidade validar ou não a integridade atual (avaliação técnica quantitativa) de modo a conhecer se o item em questão é seguro e confiável para continuar a operar em condições específicas durante um período de tempo determinado, tendo em consideração as condições verificadas no ato de inspeção e especificações de projeto, segundo os itens de verificação de segurança estabelecidos na norma EN 1990:2002/A1:2005/AC:2010 e com base na norma API 579-1/ASME FFS-1: 2007. No âmbito do presente trabalho foram realizadas as seguintes tarefas: - Identificar e analisar os mecanismos de degradação com base na norma API RP 571: 2011, face às condições processuais e geométricas que o equipamento em análise está sujeito de modo a perceber a evolução da degradação estrutural e quais as implicações na sua longevidade. - Avaliar e propor soluções de reparação e ou alterações processuais e ou geométricas do equipamento em análise de modo a permitir a continuidade em funcionamento sem afetar as condições de segurança e por conseguinte minimizar ou evitar o elevado custo económico associado a um novo equipamento e tempo de paragem processual. - Assumir limites estruturais face às condições processuais e ações externas ou adjacentes. - Garantir a segurança e qualidade da vida humana ou meio que o rodeia, do equipamento, das instalações, das infraestruturas envolventes e evitar o colapso económico, quer por motivos processuais, quer indeminizações ou agravamento do prémio do seguro. Verificou-se que os resultados serão a base para as alterações inerentes, tais como reforço estrutural, alteração da geometria do defletor, ajuste no tensionamento dos cabos e controlo da espessura mínima, de modo a alargar o período de vida útil da flare com segurança.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As neurociências aliadas ao marketing, constituem um novo paradigma com grande potencial, no que diz respeito ao conhecimento profundo do consumidor e do seu comportamento de compra: o Neuromarketing. O Neuromarketing tem uma forte componente científica que estuda e define fisiologicamente os mecanismos subjacentes à cognição, com foco específico nas bases neurais dos processos mentais e suas manifestações comportamentais e uma componente económica e social em que os Marketeers se questionam acerca dos métodos tradicionais para conhecer profundamente o seu cliente e aplicar em toda a sua potencialidade o marketing one-to-one, criar relações de fidelidade e evitar a falta de diferenciação que ainda se verifica em algumas empresas. Na óptica do consumidor este tema é ainda desconhecido e podemos afirmar com alguma certeza que também será um pouco assustador pensar que seja possível conhecer tão bem o nosso cérebro e a nossa maneira de pensar enquanto consumidores, que nos consigam “manipular” no momento da decisão de compra. O presente estudo tem como finalidade perceber o que pensa o consumidor desta nova área, o que sente em relação aos métodos usados em Neuromarketing e se já têm alguma percepção de que diariamente já são confrontados com técnicas de Neuromarketing e ainda, o que pensam delas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho tem como objetivo o estudo da utilização do zinco e do cobre como revestimento de coberturas e de fachadas em edifícios. O trabalho inicia-se com uma introdução sobre as características do zinco e cobre e a sua aplicação desde os primeiros tempos até à atualidade. Incluiu-se uma breve explanação sobre a sua produção, extração, disponibilidade de recursos, reciclagem e compatibilidade com outros materiais. O trabalho inclui também um capítulo destinado a compreender os princípios que justificam o seu uso em revestimentos, onde se aborda a sua importância na ventilação, sistemas de drenagem e noutras temáticas associadas ao processo construtivo. Em seguida desenvolve-se um capítulo orientado para os sistemas de revestimento mais comuns, onde se faz a separação entre sistemas com e sem ventilação e as diferentes técnicas e formas de instalação. Apresenta-se finalmente um caso prático de estudo de um sistema de revestimento de uma cobertura, onde se completa com um subcapítulo destinado à quantificação da ação do vento, da chuva e dos seus efeitos, mas também, onde se realça a importância da análise do comportamento e desempenho dos respetivos órgãos de drenagem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sol-gel chemistry allows the immobilization of organic molecules of biological origin on suibtable solid supports, permitting their integration into biosensing devices widening the possibility of local applications. The present work is an application of this principle, where the link between electrical receptor platform and the antibody acting as biorecognition element is made by sol-gel chemistry. The immunosensor design was targeted for carcinoembryonic antigen (CEA), an important biomarker for screening the colorectal cancer, by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SVW). The device displayed linear behavior to CEA in EIS and in SWV assays ranging from 0.50 to 1.5ng/mL, and 0.25 to 1.5ng/mL, respectively. The corresponding detection limits were 0.42 and 0.043 ng/mL. Raman spectroscopy was used to characterize the surface modifications on the conductive platform (FTO glass). Overall, simple sol-gel chemistry was effective at the biosensing design and the presented approach can be a potential method for screening CEA in point-of-care, due to the simplicity of fabrication, short response time and low cost. - See more at: http://www.eurekaselect.com/127192/article#sthash.m1AWhINx.dpuf

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a novel use for the polymeric film, poly(o-aminophenol) (PAP) that was made responsive to a specific protein. This was achieved through templated electropolymerization of aminophenol (AP) in the presence of protein. The procedure involved adsorbing protein on the electrode surface and thereafter electroploymerizing the aminophenol. Proteins embedded at the outer surface of the polymeric film were digested by proteinase K and then washed away thereby creating vacant sites. The capacity of the template film to specifically rebind protein was tested with myoglobin (Myo), a cardiac biomarker for ischemia. The films acted as biomimetic artificial antibodies and were produced on a gold (Au) screen printed electrode (SPE), as a step towards disposable sensors to enable point-of-care applications. Raman spectroscopy was used to follow the surface modification of the Au-SPE. The ability of the material to rebind Myo was measured by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The devices displayed linear responses to Myo in EIS and SWV assays down to 4.0 and 3.5 μg/mL, respectively, with detection limits of 1.5 and 0.8 μg/mL. Good selectivity was observed in the presence of troponin T (TnT) and creatine kinase (CKMB) in SWV assays, and accurate results were obtained in applications to spiked serum. The sensor described in this work is a potential tool for screening Myo in point-of-care due to the simplicity of fabrication, disposability, short time response, low cost, good sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel surface molecularly-imprinted (MI) material to detect myoglobin (Myo) using gold screen printed electrodes (SPE) was developed. The sensitive detection was carry out by introducing a carboxylic polyvinyl chloride (PVC-COOH) layer on gold SPE surface. Myo was attached to the surface of gold SPE/PVC-COOH and the vacant spaces around it were filled by polymerizing acrylamide and N,N-methylenebisacrylamide (cross-linker). This polymerization was initiated by ammonium persulphate. After removing the template, the obtained material was able to rebind Myo and discriminate it among other interfering species. Various characterization techniques including electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) confirmed the surface modification. This sensor seemed a promising tool for screening Myo in point-of-care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation for the degree of Doctor of Philosophy in Physics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chromoblastomycosis (CBM) is a chronic subcutaneous infection caused by several dematiaceous fungi. The most commonly etiological agent found in Brazil is Fonsecaea pedrosoi, which appears as thick walled, brownish colored cells with transverse and longitudinal division in the lesions, called "muriform cells". This disease is found worldwide but countries like Madagascar and Brazil have highest incidence. Diagnosis is made by clinical, direct and histopathologic examination and culture of specimens. Serological tests have been used to identify specific antibodies against Fonsecaea pedrosoi antigens, as well as immunotechniques have been used for CBM serological identification and diagnosis. In the present study double immunodiffusion (DID), counterimmunoelectrophoresis (CIE) and immunoenzymatic test (ELISA) have been used to evaluate humoral immune response in patients with CBM caused by F. pedrosoi. Metabolic antigen was used for immunoprecipitation tests (DID and CIE) while somatic antigen for ELISA. Our results demonstrated 53% sensitivity and 96% specificity for DID, while CIE presented 68% sensitivity and 90.5% specificity. ELISA demonstrated 78% sensibility and 83% specificity. Serological tests can be a useful tool to study different aspects of CBM, such as helping differential diagnosis, when culture of the pathogenic agent is impossible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, the performance of Immunomagnetic Separation technique, coupled with Immunofluorescence (IMS-IFA), was compared with the FAUST et al. and Lutz parasitological techniques for the detection of Giardia lamblia cysts in human feces. One hundred and twenty-seven samples were evaluated by the three techniques at the same time showing a rate of cyst detection of 27.5% by IMS-IFA and 15.7% by both Faust et al. and Lutz techniques. Data analysis showed a higher sensitivity of IMS-IFA for the detection of G. lamblia cysts in comparison with the techniques of FAUST et al. and Lutz. The use of this methodology as a routine procedure enables the processing of many samples simultaneously, in order to increase recovery rate of G. lamblia cysts and reduce the time of sample storage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol–gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about −58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes −54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.