983 resultados para BETA-PHASE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a single-phase Series Active Power Filter (Series APF) for mitigation of the load voltage harmonic content, while maintaining the voltage on the DC side regulated without the support of a voltage source. The proposed series active power filter control algorithm eliminates the additional voltage source to regulate the DC voltage, and with the adopted topology it is not used a coupling transformer to interface the series active power filter with the electrical power grid. The paper describes the control strategy which encapsulates the grid synchronization scheme, the compensation voltage calculation, the damping algorithm and the dead-time compensation. The topology and control strategy of the series active power filter have been evaluated in simulation software and simulations results are presented. Experimental results, obtained with a developed laboratorial prototype, validate the theoretical assumptions, and are within the harmonic spectrum limits imposed by the international recommendations of the IEEE-519 Standard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Advanced Optometry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to communication and technology developments, residential consumers are enabled to participate in Demand Response Programs (DRPs), control their consumption and decrease their cost by using Household Energy Management (HEM) systems. On the other hand, capability of energy storage systems to improve the energy efficiency causes that employing Phase Change Materials (PCM) as thermal storage systems to be widely addressed in the building applications. In this paper, an operational model of HEM system considering the incorporation of more than one type of PCM in plastering mortars (hybrid PCM) is proposed not only to minimize the customerâ s cost in different DRPs but also to guaranty the habitantsâ  satisfaction. Moreover, the proposed model ensures the technical and economic limits of batteries and electrical appliances. Different case studies indicate that implementation of hybrid PCM in the buildings can meaningfully affect the operational pattern of HEM systems in different DRPs. The results reveal that the customerâ s electricity cost can be reduced up to 48% by utilizing the proposed model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, considering the high variety of construction products, adequate material selection, based on their properties and function, becomes increasingly important. In this research, a ranking procedure developed by Czarnecki and Lukowski is applied in mortars with incorporation of phase change materials (PCM). The ranking procedure transforms experimental results of properties into one numerical value. The products can be classified according to their individual properties or even an optimized combination of different properties. The main purpose of this study was the ranking of mortars with incorporation of different contents of PCM based in different binders. Aerial lime, hydraulic lime, gypsum and cement were the binders studied. For each binder, three different mortars were developed. Reference mortars, mortars with incorporation of 40% of PCM and mortars with incorporation of 40% of PCM and 1% of fibers, were tested. Results show that the incorporation of PCM in mortars changes their global performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Partition behavior of eight small organic compounds and six proteins was examined in poly(ethylene glycol)-8000sodium sulfate aqueous two-phase systems containing 0.215 M NaCl and 0.5 M osmolyte (sorbitol, sucrose, TMAO) and poly(ethylene glycol)-10000sodium sulfate0.215 M NaCl system, all in 0.01 M sodium phosphate buffer, pH 6.8. The differences between the solvent properties of the coexisting phases (solvent dipolarity/polarizability, hydrogen bond donor acidity, and hydrogen bond acceptor basicity) were characterized with solvatochromic dyes using the solvatochromic comparison method. Differences between the electrostatic properties of the phases were determined by analysis of partitioning of sodium salts of dinitrophenylated (DNP-) amino acids with aliphatic alkyl side-chain. The partition coefficients of all compounds examined (including proteins) were described in terms of solutesolvent interactions. The results obtained in the study show that solutesolvent interactions of nonionic organic compounds and proteins in polyethylene glycolsodium sulfate aqueous two-phase system change in the presence of NaCl additive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple procedure for the simultaneous detection of cyclopiazonic acid (CPA) and aflatoxin B1 from fungal extracts is presented, using a methanol and water mobile phase and fluorescence detection. This methodology has been tested with standard solutions of both mycotoxins CPA and Aflatoxin B1 and with methanolic extracts of Aspergillus section Flavi strains, previously characterized for their mycotoxin production profile. Previously available methodology required the use of two different chromatographic runs for these mycotoxins, with distinct columns and detectors (fluorescence detection with a post-column photochemical derivatization (PHRED) for aflatoxin B1 and UV detection for CPA). The proposed method detects both mycotoxins in a single run. Data from these assays will be presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Between 2008 and 2009 a preventive excavation supervised by the Unit of Archaeology of the University of Minho was conducted in an area with approximately 5000 square meters allowing the identification of a wide sector of the Via XVII necropolis, which is one of the five roman necropolises known to have existed in Bracara Augusta. The findings enabled us to define a typological framework related with incinerations, to understand the internal organization of the necropolis and recover the ritual marks of the funerary practices between the first century BC and the second century AD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Partition behavior of adenosine and guanine mononucleotides was examined in aqueous dextran-polyethylene glycol (PEG) and PEG-sodium sulfate two-phase systems. The partition coefficients for each series of mononucleotides were analyzed as a functions of the number of phosphate groups and found to be dependent on the nature of nucleic base and on the type of \ATPS\ utilized. It was concluded that an average contribution of a phosphate group into logarithm of partition coefficient of a mononucleotide cannot be used to estimate the difference between the electrostatic properties of the coexisting phases of ATPS. The data obtained in this study were considered together with those for other organic compounds and proteins reported previously, and the linear interrelationship between logarithms of partition coefficients in dextran-PEG, PEG-Na2SO4 and PEG-Na2SO4-0.215 M NaCl (all in 0.01 M Na- or K/Na-phosphate buffer, pH 7.4 or 6.8) was established. Similar relationship was found for the previously reported data for proteins in Dex-PEG, PEG-600-Na2SO4, and PEG-8000-Na2SO4 ATPS. It is suggested that the linear relationships of the kind established in \ATPS\ may be observed for biological properties of compounds as well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the effects of carvedilol in patients with idiopathic dilated cardiomyopathy. METHODS: In a double-blind randomized placebo-controlled study, 30 patients (7 women) with functional class II and III heart failure were assessed. Their ages ranged from 28 to 66 years (mean of 43±9 years), and their left ventricular ejection fraction varied from 8% to 35%. Carvedilol was added to the usual therapy of 20 patients; placebo was added to the usual therapy of 10 patients. The initial dose of carvedilol was 12.5 mg, which was increased weekly until it reached 75 mg/day, according to the patient's tolerance. Clinical assessment, electrocardiogram, echocardiogram, and radionuclide ventriculography were performed in the pretreatment phase, being repeated after 2 and 6 months of medication use. RESULTS: A reduction in heart rate (p=0.016) as well as an increase in left ventricular shortening fraction (p=0.02) and in left ventricular ejection fraction (p=0.017) occurred in the group using carvedilol as compared with that using placebo. CONCLUSION: Carvedilol added to the usual therapy for heart failure resulted in better heart function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Bioquímica Aplicada (área de especialização em Biotecnologia)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiac dysfunction in heart failure is widely recognized as a progressive process, regardless of the clinical signs and symptoms. An increase in cardiac sympathetic drive is one of the earliest neurohormonal responses occurring in patients with heart failure and may be one of the major causes of the progressive remodeling leading to the decline in myocardial function, and responsible for the poor prognosis of patients with heart failure. Therefore, recent data provided by several appropriately designed clinical trials clearly indicate the benefits of beta-adrenoceptor blocking agents, combined with diuretics, ACE inhibitors, and digoxin in chronic heart failure class II to IV due to systolic ventricular dysfunction. The benefits are related to symptoms, functional capacity, remodeling, and improvement in left ventricular function, reduction in cardiovascular hospitalization, a decrease in the overall and sudden cardiac death rate, and are similar in patients with ischemic or nonischemic cardiomyopathy, independent of age, gender, or functional class. In this review we describe the cardiovascular effects of the increase in sympathetic drive, the pharmacological properties of the beta-blockers most evaluated in heart failure therapy (metoprolol, bisoprolol, and carvedilol), the major clinical trials related to these agents in heart failure, the recommendations for their appropriate use in clinical practice, the precautions to be adopted, and how to handle the more common adverse reactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The initial site of myocardial infarction (MI) may influence the prevalence of ventricular late potentials (VLP), high-frequency signals, due to the time course of ventricular activation. The prevalence of VLP in a period of more than 2 years after acute MI was assessed focusing on the initially injured wall . METHODS: The prevalence of VLP in a late phase after MI (median of 924 days) in anterior/antero-septal and inferior/infero-dorsal wall lesion was analyzed using signal-averaged electrocardiogram in time domain. The diagnostic performance of the filters employed for analysis on was tested at high-pass cut-off frequencies of 25 Hz, 40 Hz and 80 Hz. RESULTS: The duration of the ventricular activation and its terminal portion were larger in inferior than anterior infarction, at high-pass cut-off frequencies of 40 Hz and 80 Hz. In patients with ventricular tachycardia, these differences were more remarked. The prevalence of ventricular late potentials was three times greater in inferior than anterior infarction. CONCLUSION: Late after myocardial infarction, the prevalence and the duration of ventricular late potentials are greater in lesions of inferior/infero-dorsal than anterior/antero-septal wall confirming their temporal process, reflecting their high-frequency content.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a model predictive current control applied to a proposed single-phase five-level active rectifier (FLAR). This current control strategy uses the discrete-time nature of the active rectifier to define its state in each sampling interval. Although the switching frequency is not constant, this current control strategy allows to follow the reference with low total harmonic distortion (THDF). The implementation of the active rectifier that was used to obtain the experimental results is described in detail along the paper, presenting the circuit topology, the principle of operation, the power theory, and the current control strategy. The experimental results confirm the robustness and good performance (with low current THDF and controlled output voltage) of the proposed single-phase FLAR operating with model predictive current control.