980 resultados para yellow cardinal
Resumo:
Glucose sensing is an issue with great interest in medical and biological applications. One possible approach to glucose detection takes advantage of measuring changes in fluorescence resonance energy transfer (FRET) between a fluorescent donor and an acceptor within a protein which undergoes glucose-induced changes in conformation. This demands the detection of fluorescent signals in the visible spectrum. In this paper we analyzed the emission spectrum obtained from fluorescent labels attached to a protein which changes its conformation in the presence of glucose using a commercial spectrofluorometer. Different glucose nanosensors were used to measure the output spectra with fluorescent signals located at the cyan and yellow bands of the spectrum. A new device is presented based on multilayered a-SiC:H heterostructures to detect identical transient visible signals. The transducer consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructure optimized for the detection of the fluorescence resonance energy transfer between fluorophores with excitation in the violet (400 nm) and emissions in the cyan (470 nm) and yellow (588 nm) range of the spectrum. Results show that the device photocurrent signal measured under reverse bias and using appropriate steady state optical bias, allows the separate detection of the cyan and yellow fluorescence signals presented.
Resumo:
Glucose sensing is an issue with great interest in medical and biological applications. One possible approach to glucose detection takes advantage of measuring changes in fluorescence resonance energy transfer (FRET) between a fluorescent donor and an acceptor within a protein which undergoes glucose-induced changes in conformation. This demands the detection of fluorescent signals in the visible spectrum. In this paper we analyzed the emission spectrum obtained from fluorescent labels attached to a protein which changes its conformation in the presence of glucose using a commercial spectrofluorometer. Different glucose nanosensors were used to measure the output spectra with fluorescent signals located at the cyan and yellow bands of the spectrum. A new device is presented based on multilayered a-SiC:H heterostructures to detect identical transient visible signals. The transducer consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructure optimized for the detection of the fluorescence resonance energy transfer between fluorophores with excitation in the violet (400 nm) and emissions in the cyan (470 nm) and yellow (588 nm) range of the spectrum. Results show that the device photocurrent signal measured under reverse bias and using appropriate steady state optical bias, allows the separate detection of the cyan and yellow fluorescence signals. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
Dissertação de Mestrado, Engenharia Agronómica, 16 de Junho de 2014, Universidade dos Açores.
Resumo:
The dispersal flights of West Indian drywood termite, Cryptotermes brevis (Walker) (Isoptera: Kalotermitidae) were surveyed in the major cities of Azores. The sampling device used to estimate termite density consisted of a yellow adhesive trap (size 45 by 24 cm), placed with an artificial or natural light source in a dark attic environment. In addition, data from two other projects were used to improve the knowledge about the geographical distribution of the species. The level of infestation in the two main Azorean towns differed, with high levels in the houses of Angra do Heroísmo, whereas in Ponta Delgada, there are fewer houses with high levels of infestation. The infestation in Ponta Delgada shows a pattern of spreading from the center outward to the city's periphery, whereas in Angra do Heroísmo, there was a pattern of spreading outward from several foci. The heavy infestation observed in Angra do Heroísmo and the clear increase of infestation levels observed from 2010 to 2011 is a reason for concern and calls for an urgent application of an Integrated Pest Management (IPM) control strategy.
Resumo:
Este trabalho na área dos processos físicos de separação por membranas, nomeadamente, a nanofiltração (NF), tem como objectivo principal a recuperação dos efluentes resultantes das águas da 3ª lavagem utilizadas na operação de tingimento de fibras de algodão, com corantes reactivos. Estão inerentes as problemáticas: da escassez da água como matéria-prima na vertente de água potável; da diminuição de efluentes que necessitam de tratamentos devido à sua carga poluente; da recuperação sempre que seja viável dos produtos químicos adicionados nesta fase de tratamento das fibras de algodão e por último e não menos importante, da energia contida nestes efluentes que vão para o esgoto a temperaturas na ordem dos 50 ºC. A metodologia adoptada na realização deste trabalho consistiu, inicialmente num estudo sobre os trabalhos realizados até hoje nesta área, seguindo-se a recolha dos efluentes na empresa ―Estamparia Têxtil Adalberto Pinto da Silva, S.A.‖ (ETAPS) e posterior estudo da recuperação dos efluentes em causa pelo processo de NF utilizando a membrana NF270-2540 da empresa FILMTEC. Os efluentes estudados no presente trabalho continham corantes reactivos sendo um corante azul-claro (CAC) de composição (Amarelo Bril Remazol GL 150% + Azul Brilhante Remazol BB 133% + Azul Turqueza Remazol G) e o outro corante azul-marinho (CAM) de composição (Preto Remazol B 133% + Vermelho Remazol RGB + Amarelo Ouro Remazol RGB). Estes estudos de recuperação compreenderam basicamente 3 fases: caracterização do efluente recolhido na empresa; tratamento desse efluente utilizando uma instalação piloto de NF de fluxo cruzado ou também conhecido por membrana de fluxo tangencial instalado no Laboratório de Tecnologia (LT) do Instituto Superior de Engenharia do Porto (ISEP), e caracterização dos permeados e dos rejeitados obtidos. A análise de resultados do presente trabalho permitiu concluir ser possível a recuperação e reutilização das 3ª águas de lavagem do processo de tingimento quando tratadas pelo processo de NF a pressões de operação de 6 bar. Nestas circunstâncias os permeados obtidos (tanto no efluente com corante azul-claro como no efluente com corante azul-marinho) apresentam valores, em todos os parâmetros estudados, significativamente abaixo dos valores limites recomendáveis para uma água de abastecimento na Industria Têxtil (IT). Salienta-se reduções mais expressivas nos permeados do corante CAM, com vários parâmetros a sofrerem reduções no intervalo de 98 a 100%, nomeadamente, na cor, turvação, CQO, dureza total, alumínio e manganês. Os resultados obtidos para as pressões de operação de 4 e 8 bar mostram alguns parâmetros com valores acima dos recomendados para uma água de abastecimento na Indústria Têxtil, nomeadamente a cor no corante CAC quando se opera a 4 bar e no corante CAM quando se opera a 8 bar e os sulfatos e ferro no CAM à pressão de 4 bar. Estes resultados mostram ser possível a reutilização da água na própria instalação industrial, trazendo um benefício económico e ambiental, pela redução no consumo de água fresca e energia, além da redução do volume de efluentes que necessitam ser tratados, estando na mesma linha de pensamento de Gross et al (1999), que refere que o uso de membranas para o tratamento de efluentes do processo de tingimento tem como principal objectivo a viabilidade económica, a redução no consumo de água, de sais, de corantes e energia, bem como, a redução do volume de efluentes a ser tratado.
Resumo:
This paper presents a resume of the results achieved by researchers of the Centro de Estratigrafia e Paleobiologia da U. N. L. on the Neogene of Algarve, since 1977. The detailed study of several profiles as well as that af calcareous nannoplanton, planktonic foraminifera, ostracoda, fishes and mammals allowed to obtain data and correlation elements leading to a new interpretation of the Miocene of Algarve. It was possible to date and to characterize the following units: a) Carbonate formation of Lagos-Portimão, of marine facies, ascribed to the Lower Miocene (Aquitanian? and mainly Burdigalian), possibly attaining the Lower Langhian. b) Essentially arenaceous series of continental facies with a marine intercalation of Arrifão, Olhos de Água and Auramar Hotel beach, middle Miocene (Langhian-Serravallian) in age. c) Marine (tripoli, conglomerates, sands and limestones) deposits of Tunes-Mem Moniz, Ponte das Lavadeiras (Faro), Arroteia (Fuzeta) and Luz de Tavira, corresponding, at least partially, to the first part of the upper Miocene (Lower Tortonian). d) Cacela formation with three members: The lower member (conglomerates and sands), the middle (yellow silts) and the upper ones (gray silts), uppermost Tortonian and mainly Messinian in age. An interpretation of the tectonic and paleogeographic evolution of the portuguese littoral during the Miocene is also presented considering its insertion in the meridional part of the Peninsula (Guadalquivir depression, Betic massif basins and in the spanish Levant in general). Comparisons among the Neogene vulcanism of this region and similar manifestations documented in Algarve (basanite of Figueira-Portimão, etc) are established.
Resumo:
OBJECTIVE To analyze the incremental cost-utility ratio for the surgical treatment of hip fracture in older patients.METHODS This was a retrospective cohort study of a systematic sample of patients who underwent surgery for hip fracture at a central hospital of a macro-region in the state of Minas Gerais, Southeastern Brazil between January 1, 2009 and December 31, 2011. A decision tree creation was analyzed considering the direct medical costs. The study followed the healthcare provider’s perspective and had a one-year time horizon. Effectiveness was measured by the time elapsed between trauma and surgery after dividing the patients into early and late surgery groups. The utility was obtained in a cross-sectional and indirect manner using the EuroQOL 5 Dimensions generic questionnaire transformed into cardinal numbers using the national regulations established by the Center for the Development and Regional Planning of the State of Minas Gerais. The sample included 110 patients, 27 of whom were allocated in the early surgery group and 83 in the late surgery group. The groups were stratified by age, gender, type of fracture, type of surgery, and anesthetic risk.RESULTS The direct medical cost presented a statistically significant increase among patients in the late surgery group (p < 0.005), mainly because of ward costs (p < 0.001). In-hospital mortality was higher in the late surgery group (7.4% versus 16.9%). The decision tree demonstrated the dominance of the early surgery strategy over the late surgery strategy: R$9,854.34 (USD4,387.17) versus R$26,754.56 (USD11,911.03) per quality-adjusted life year. The sensitivity test with extreme values proved the robustness of the results.CONCLUSIONS After controlling for confounding variables, the strategy of early surgery for hip fracture in the older adults was proven to be dominant, because it presented a lower cost and better results than late surgery.
Resumo:
Dissertação apresentada para a obtenção do Grau de Doutor em Química, especialidade em Química-Física, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
ABSTRACT OBJECTIVE To identify the factors associated with severity of malocclusion in a population of adolescents. METHODS In this cross-sectional population-based study, the sample size (n = 761) was calculated considering a prevalence of malocclusion of 50.0%, with a 95% confidence level and a 5.0% precision level. The study adopted correction for the effect of delineation (deff = 2), and a 20.0% increase to offset losses and refusals. Multistage probability cluster sampling was adopted. Trained and calibrated professionals performed the intraoral examinations and interviews in households. The dependent variable (severity of malocclusion) was assessed using the Dental Aesthetic Index (DAI). The independent variables were grouped into five blocks: demographic characteristics, socioeconomic condition, use of dental services, health-related behavior and oral health subjective conditions. The ordinal logistic regression model was used to identify the factors associated with severity of malocclusion. RESULTS We interviewed and examined 736 adolescents (91.5% response rate), 69.9% of whom showed no abnormalities or slight malocclusion. Defined malocclusion was observed in 17.8% of the adolescents, being severe or very severe in 12.6%, with pressing or essential need of orthodontic treatment. The probabilities of greater severity of malocclusion were higher among adolescents who self-reported as black, indigenous, pardo or yellow, with lower per capita income, having harmful oral habits, negative perception of their appearance and perception of social relationship affected by oral health. CONCLUSIONS Severe or very severe malocclusion was more prevalent among socially disadvantaged adolescents, with reported harmful habits and perception of compromised esthetics and social relationships. Given that malocclusion can interfere with the self-esteem of adolescents, it is essential to improve public policy for the inclusion of orthodontic treatment among health care provided to this segment of the population, particularly among those of lower socioeconomic status.
Resumo:
New highly fluorescent calix[4]arene-containing phenylene-alt-ethynylene-3,6- and 2,7-carbazolylene polymers (CALIX-PPE-CBZs) have been synthesized for the first time and their photophysical properties evaluated. Both polymers were obtained in good isolated yields (70-84%), having M-w ranging from 7660-26,700 g mol(-1). It was found that the diethynyl substitution (3,6- or 2,7-) pattern on the carbazole monomers markedly influences the degree of polymerization. The amorphous yellow polymers are freely soluble in several nonprotic organic solvents and have excellent film forming abilities. TG/DSC analysis evidences similar thermal behaviors for both polymers despite their quite different molecular weight distributions and main-chain connectivities (T-g, in the range 83-95 degrees C and decomposition onsets around 270 degrees C). The different conjugation lengths attained by the two polymers dictates much of their photophysical properties. Thus, whereas the fully conjugated CALIX-PPE-2,7-CBZ has its emission maximum at 430 nm (E-g = 2.84 eV; Phi(F) = 0.62, CHCl3), the 3,6-linked counterpart (CALIX-PPE-3,6-CBZ) fluoresces at 403 nm with a significant lower quantum yield (E-g = 3.06 eV; Phi(F) = 0.31, CHCl3). The optical properties of both polymers are predominantly governed by the intrachain electronic properties of the conjugated backbones owing to the presence of calix[4]arenes along the polymer chain which disfavor significant interchain interactions, either in fluid- or solid-state.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Conservação e Restauro, especialidade Teoria, História e Técnicas, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
O bacalhau (Gadus morhua) faz parte da dieta alimentar dos portugueses há vários séculos, sendo atualmente, um dos maiores consumidores deste peixe a nível mundial. Após o processo de salga, esta espécie possui características únicas como a consistência, cheiro, paladar e cor amarela. É precisamente devido à coloração do peixe que alguns produtores da Islândia, Noruega e Dinamarca requisitaram às autoridades da União Europeia (UE) a aprovação da utilização de polifosfatos no processo de salga húmida do bacalhau. Os polifosfatos são aditivos alimentares bastante usados no processamento do pescado pois previnem a oxidação dos lípidos e proteínas do músculo do bacalhau, evitando assim a indesejada mudança de cor do peixe. Apesar dos esforços da Associação dos Industriais do Bacalhau (AIB) e do governo português para a rejeição da proposta nórdica, tal não se verificou. Deste modo, no início do próximo ano já será possível a venda na UE de bacalhau com fosfatos. A quantificação do teor de fosfatos no bacalhau é geralmente efetuada por Espetrofotometria de absorção molecular no ultravioleta-visível (UV-Visível). Esta quantificação é baseada no método de determinação do fósforo total, através da hidrólise dos fosfatos a ortofosfatos com posterior medição da cor amarela, gerada pela reação destes com uma solução de molibdato-vanadato. O objetivo desta dissertação foi a validação de um método de análise para a quantificação dos polifosfatos no bacalhau. O método validado foi o descrito na norma NP 4495 para produtos de pesca e aquicultura. O desenvolvimento deste trabalho foi realizado em laboratório acreditado para águas e produtos alimentares (Equilibrium - Laboratório de Controlo de Qualidade e de Processos Lda, L0312). Foi ainda determinada a influência do teor de cloreto de sódio na quantificação dos polifosfatos e o teor de humidade, uma vez que este pode afetar o produto durante a sua comercialização. No processo de validação do método foram estudados diversos parâmetros, tais como a seletividade, linearidade, sensibilidade, limite de quantificação e precisão. Pela análise dos resultados obtidos conclui-se que o método para determinação de fosfatos no bacalhau se encontra validado, uma vez que satisfaz todas as especificações determinadas para cada parâmetro de validação avaliado.
Resumo:
24 cases of fulminant hepatitis (FH) hospitalized in the Clínica de Doenças Infecciosas e Parasitárias do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo during the period from January 1976 to December 1986 were reviewed from their clinical, epidemiological and laboratorial aspects. 88% of the patients died; 20 patients (83%) presented hemorrhages and, of these, 19 died. Bacterial infections occurred in 14 patients (58%) all of whom died. Ascitis was noted in 3 cases; cerebral edema was present in 16 cases. Maximal ALT levels for each patient during hospitalization ranged widely from 81 to 4,460 UI/l. Thirteen patients presented high creatinine levels (54%). Prothrombin time activity ranged from 2.1% to 67%. Fever was present in 20 cases (83%). Encephalopathy occurred within the first 2 weeks of illness in 72% of the cases. In 7 cases other illnesses were present. The etiology could not be determined in 13 cases. In 3 cases it was due to yellow fever and 6 cases were caused by viruses other than yellow fever. In one case the cause was drug usage and in another case, possibly alcohol. The authors believe that the clinical definition of FH requires further discussion before it is established. In this study FH is a young person's disease. The mortality found was similar to that by other authors. Factors that contributed to death were: hemorrhages and bacterial infection. Factors that worsened the prognosis of hepatitis were: associated illnesses and surgical procedure. The levels of ALT during hospitalization did not correlate well with the severity of the hepatitis. The authors believe that yellow fever should be considered a cause of FH where the clinical picture meets the criteria for such, although its mechanisms of encephalopathy remain obscure. The clinical details of the 3 cases of yellow fever are presented.
Resumo:
Glucose monitoring in vivo is a crucial issue for gaining new understanding of diabetes. Glucose binding protein (GBP) fused to two fluorescent indicator proteins (FLIP) was used in the present study such as FLIP-glu- 3.2 mM. Recombinant Escherichia coli whole-cells containing genetically encoded nanosensors as well as cell-free extracts were immobilized either on inner epidermis of onion bulb scale or on 96-well microtiter plates in the presence of glutaraldehyde. Glucose monitoring was carried out by Förster Resonance Energy Transfer (FRET) analysis due the cyano and yellow fluorescent proteins (ECFP and EYFP) immobilized in both these supports. The recovery of these immobilized FLIP nanosensors compared with the free whole-cells and cell-free extract was in the range of 50–90%. Moreover, the data revealed that these FLIP nanosensors can be immobilized in such solid supports with retention of their biological activity. Glucose assay was devised by FRET analysis by using these nanosensors in real samples which detected glucose in the linear range of 0–24 mM with a limit of detection of 0.11 mM glucose. On the other hand, storage and operational stability studies revealed that they are very stable and can be re-used several times (i.e. at least 20 times) without any significant loss of FRET signal. To author's knowledge, this is the first report on the use of such immobilization supports for whole-cells and cell-free extract containing FLIP nanosensor for glucose assay. On the other hand, this is a novel and cheap high throughput method for glucose assay.