999 resultados para wet test chamber
Resumo:
Scand J Clin Lab Invest. 2007 Aug 1;:1-11 [Epub ahead of print]
Resumo:
INTRODUCTION: Extensor mechanism ruptures might be easily overlooked and misdiagnosed, and delayed diagnosis of quadriceps tendon rupture is frequent. However, the literature recommends early surgical repair within 72 h. PATIENTS AND METHODS: This paper describes a new simple clinical diagnostic test that directly evaluates the integrity of the distal 5 cm of the quadriceps tendon itself. It consists of inserting a needle in the tendon, proximal to the suspected rupture and mobilising the knee joint. RESULTS: The suspected ruptured quadriceps tendons with a positive 'needle' diagnostic test were confirmed intra-operatively. CONCLUSIONS: This minimally invasive and easily available technique should be considered in the diagnostic work-up and treatment planning of patients with suspected tears of the quadriceps tendon.
Resumo:
Langattoman laajakaistaisen tietoliikennetekniikan kehittyminen on herättänyt kiinnostuksen sen ammattimaiseen hyödyntämiseen yleisen turvallisuuden ja kriisinhallinnan tarpeisiin. Hätätilanteissa usein olemassa olevat kiinteät tietoliikennejärjestelmät eivät ole ollenkaan käytettävissä tai niiden tarjoama kapasiteetti ei ole riittävä. Tästä syystä on noussut esiin tarve nopeasti toimintakuntoon saatettaville ja itsenäisille langattomille laajakaistaisille järjestelmille. Tässä diplomityössä on tarkoitus tutkia langattomia ad hoc monihyppy -verkkoja yleisen turvallisuuden tarpeiden pohjalta ja toteuttaa testialusta, jolla voidaan demonstroida sekä tutkia tällaisen järjestelmän toimintaa käytännössä. Työssä tutkitaan pisteestä pisteeseen sekä erityisesti pisteestä moneen pisteeseen suoritettavaa tietoliikennettä. Mittausten kohteena on testialustan tiedonsiirtonopeus, lähetysteho ja vastaanottimen herkkyys. Näitä tuloksia käytetään simulaattorin parametreina, jotta simulaattorin tulokset olisivat mahdollisimman aidot ja yhdenmukaiset testialustan kanssa. Sen jälkeen valitaan valikoima yleisen turvallisuuden vaatimusten mukaisia ohjelmia ja sovellusmalleja, joiden suorituskyky mitataan erilaisten reititysmenetelmien alaisena sekä testialustalla että simulaattorilla. Tuloksia arvioidaan ja vertaillaan. Multicast monihyppy -video päätettiin sovelluksista valita tutkimusten pääkohteeksi ja sitä sekä sen ominaisuuksia on tarkoitus myös oikeissa kenttäkokeissa.
Resumo:
L'idée de complémentarité de certaines épreuves projectives s'est dessinée dès les années 1960, telles que Rorschach - test du Village, Rorschach - CAT et enfin Rorschach - TAT. L'essentiel des dispositifs projectifs mobilise les épreuves de Rorschach et de TAT dont la complémentarité a été largement pointée, notamment, par Anzieu et Chabert (1983), Chabert (1998), Roman (2006, 2007, 2009) et Emmanuelli et Azoulay (2001, 2008, 2009). Les épreuves de Hand-Test, Rorschach et TAT opèrent selon des dynamiques différentes à partir de consignes, sorte d'« injonction à imaginer » (Roman, 2008). Le défi méthodologique et épistémologique est d'envisager une complémentarité entre ces trois épreuves projectives, complémentarité qui ne va pas de soi dans la mesure où le Hand-Test a été pensé à partir du modèle de l'Analyse Structurale, le Rorschach et le TAT dans une perspective psychodynamique. L'enjeu du défi est de parvenir à se dégager du modèle de l'Analyse Structurale, d'une dimension déterministe et inscrire le Hand-Test dans une dimension processuelle d'une part, et de croiser ces trois épreuves afin de parvenir à mettre en avant les ressources du sujet quant à l'émergence de potentialités de transformations bien souvent, trop souvent, reléguées au second plan, voire négligées, lors de la prise en charge institutionnelle d'autre part. Ainsi, l'approche de la complémentarité des épreuves se trouve au service d'une compréhension de l'évolution du rapport à l'agir chez les adolescents. L'écart qui se donne à voir entre la conception des épreuves projectives envisagées dans une perspective psychodynamique et la manière d'appréhender le Hand-Test constitue le défi méthodologique et épistémologique que nous proposons de discuter.
Resumo:
Perushyväksymistestaus on oleellinen osa S60 alustan julkaisukandidaatin maturiteetin seurannassa. Perushyväksymistestausta tehdään myös ohjelmiston julkistamiskelpoisuuden varmistamiseksi. Testaustulokset halutaan aina mahdollisimman nopeasti. Lisäksi testaustiimin työmäärä on hiljalleen kasvanut, koska projekteja onenemmän ja korjauksia sisältäviä ja räätälöityjä settejä testataan enemmän. Tässä diplomityössä tutkitaan lyhentäisikö testisetin osan automatisointi testien ajoaikaa ja helpottaisiko se testaajien työtaakkaa. Tarkastelu toteutetaan automatisoimalla osa testisetistä ja kokemuksia esitellään tässä lopputyössä.
Resumo:
Nowadays the used fuel variety in power boilers is widening and new boiler constructions and running models have to be developed. This research and development is done in small pilot plants where more faster analyse about the boiler mass and heat balance is needed to be able to find and do the right decisions already during the test run. The barrier on determining boiler balance during test runs is the long process of chemical analyses of collected input and outputmatter samples. The present work is concentrating on finding a way to determinethe boiler balance without chemical analyses and optimise the test rig to get the best possible accuracy for heat and mass balance of the boiler. The purpose of this work was to create an automatic boiler balance calculation method for 4 MW CFB/BFB pilot boiler of Kvaerner Pulping Oy located in Messukylä in Tampere. The calculation was created in the data management computer of pilot plants automation system. The calculation is made in Microsoft Excel environment, which gives a good base and functions for handling large databases and calculations without any delicate programming. The automation system in pilot plant was reconstructed und updated by Metso Automation Oy during year 2001 and the new system MetsoDNA has good data management properties, which is necessary for big calculations as boiler balance calculation. Two possible methods for calculating boiler balance during test run were found. Either the fuel flow is determined, which is usedto calculate the boiler's mass balance, or the unburned carbon loss is estimated and the mass balance of the boiler is calculated on the basis of boiler's heat balance. Both of the methods have their own weaknesses, so they were constructed parallel in the calculation and the decision of the used method was left to user. User also needs to define the used fuels and some solid mass flowsthat aren't measured automatically by the automation system. With sensitivity analysis was found that the most essential values for accurate boiler balance determination are flue gas oxygen content, the boiler's measured heat output and lower heating value of the fuel. The theoretical part of this work concentrates in the error management of these measurements and analyses and on measurement accuracy and boiler balance calculation in theory. The empirical part of this work concentrates on the creation of the balance calculation for the boiler in issue and on describing the work environment.
Resumo:
The objective of this work was to evaluate the use of the conductivity test as a means of predicting seed viability in seven Passiflora species: P. alata, P. cincinnata, P. edulis f. edulis, P. edulis f. flavicarpa, P. morifolia, P. mucronata, and P. nitida. Conductivity of non-desiccated (control), desiccated, and non-desiccated cryopreserved seeds was determined and related to their germination percentage. The obtained results suggest that the electrical conductivity test has potential as a germination predictor for P. edulis f. flavicarpa seed lots, but not for the other tested species.
Resumo:
CERNin tutkimuskeskuksen rakenteilla olevan hadronikiihdyttimen eräs tarkoitus on todistaa Higgsin bosonin olemassaolo. Higgsin bosonin löytyminen yhtenäistäisi nykyisen hiukkasfysiikan teorian ja antaisi selityksen sille kuinka hiukkaset saavat massansa. Kiihdyttimen CMS koeasema on tarkoitettu erityisesti myonien ilmaisuun. Tämä työ liittyy CMS koeaseman RPC-ilmaisintyypin linkkijärjestelmään, jonka tarkoituksena on käsitellä ilmaisimelta tulevia myonien aiheuttamia signaaleja ja lähettää tiedot tärkeäksi katsotuista törmäystapahtumista tallennettavaksi analysointia varten. Työssä on toteutettu linkkijärjestelmän ohjaus- ja linkkikorteille testiympäristö, jolla voidaan todeta järjestelmän eri osien keskinäinen yhteensopivuus ja toimivuus. Työn alkuosassa esitellään ilmaisimen linkkijärjestelmän eri osat ja niiden merkitykset. Työn loppuosassa käydään läpi eri testimenetelmiä ja analysoidaan niiden antamia tuloksia.
Resumo:
Euroopan hiukkastutkimuslaitoksen CERNin rakenteilla olevan LHC-hiukkaskiihdyttimen CMS-koeasema on tarkoitettu erityisesti myonin ilmaisuun. Tässä työssä on esitelty CMS-koeaseman RPC-ilmaisintyypin linkkijärjestelmä ja sen testaamiseen tarkoitetut laitteet sekä laitteiden testaamiseen tarvittavat ohjelmistot. Työssä on selvitetty ohjelmien toimivuus ja keskinäinen yhteensopivuus.
Resumo:
The natural dissipation rates of sidestream smoke (SS) particles dispersed in a chamber were studied from the standpoint of a static atmosphere and were expressed as half-lives of residence in the air. The half-lives for particles less than 0.3 micron, 0.3-0.5 micron and 0.5-1 micron were found to be 25.5, 12.8 and 4.9 h, respectively. Total particulate matter (TPM) decreases by half after 6.2 h. Other data on diluted SS in the indoor air were also reported.
Resumo:
BACKGROUND: While rifaximin was able to improve symptoms in patients with irritable bowel syndrome (IBS) in phase III trials, these results are yet to be repeated in phase IV studies. AIM: To evaluate the treatment response to rifaximin in IBS patients in a phase IV trial. METHODS: IBS patients underwent lactulose hydrogen breath testing (LHBT). LHBT-positive patients were treated with rifaximin for 14 days. Prior to treatment as well as at week 4 and 14 following the start of rifaximin treatment, patients completed a questionnaire assessing symptom severity on a Likert scale from 0 to 10. RESULTS: One hundred and six of 150 IBS patients (71%) were LHBT-positive and treated with rifaximin. As assessed at week 4 following commencement of the therapy, rifaximin provided significant improvement of the following IBS-associated symptoms: bloating (5.5±2.6 before the start of the treatment vs. 3.6±2.7 at week 4, P<0.001), flatulence (5.0±2.7 vs. 4.0±2.7, P=0.015), diarrhoea (2.9±2.4 vs. 2.0±2.4, P=0.005) and abdominal pain (4.8±2.7 vs. 3.3±2.5, P<0.001). Overall well-being also significantly improved (3.9 ± 2.4 vs. 2.7 ± 2.3, P < 0.001). Similar improvements in IBS symptoms were obtained at week 14. Eighty-six per cent of patients undergoing repetitive LHBT (55/64) tested negative at week 4. CONCLUSIONS: We found a high percentage of LHBT-positive IBS patients. IBS-associated symptoms (bloating, flatulence, diarrhoea, pain) were improved for a period of 3 months following 2 weeks of treatment with rifaximin. We conclude that rifaximin treatment alleviates symptoms in LHBT-positive IBS patients.
Resumo:
Työssä analysoidaanprosessin vaikutusta paperikoneen stabiiliuteen. Kaksi modernia sanomalehtipaperikonetta analysoitiin ja sen perusteella molemmista prosesseista rakennettiin fysiikan lakeihin perustuvat simulointimallit APROS Paper simulointiohjelmistolla. Työn tavoitteena on selvittää, miten kyseisten koneiden prosessit eroavat toisistaan ja arvioida, miten havaitut erot vaikuttavat prosessien stabiiliuteen. Työssä tarkastellaan periodisten häiriöiden vaimenemista prosessissa. Simuloinnissa herätteenä käytettiin puhdasta valkoista kohinaa, jonka avulla eri taajuistenperiodisten häiriöiden vaimenemista analysoitiin. Prosessien häiriövasteet esitetään taajuuskoordinaatistossa. Suurimmat erot prosessien välillä löytyivät viirakaivosta ja sen sekoitusdynamiikasta. Perinteisen viirakaivon todettiin muistuttavan käyttäytymiseltään sarjaan kytkettyjä ideaalisekoittimia, kun taas pienempitilavuuksisen fluumin todettiin käyttäytyvän lähes kuin putkiviive. Vaikka erotprosessitilavuudessa sekä viirakaivon sekoitusdynamiikassa olivat hyvin selkeät, havaittiin vain marginaalinen ero prosessin välillä periodisten häiriöiden vaimenemisessa, koska erot viiraretentiotasoissa vaikuttivat eniten simulointituloksia. Matalammalla viiraretentiolla operoivan paperikoneen todettiin vaimentavan tehokkaammin prosessihäiriöitä. Samalla retentiotasolla pienempitilavuuksisen prosessin todettiin vaimentavan hitaita prosessihäiriöitä marginaalisesti paremmin. Tutkituista paperikoneista toisella simuloitiin viiraosan vedenpoistomuutoksenvaikutusta viiraretentioon ja paperin koostumukseen. Lisäksi arvioitiin viiraretention säädön toimivuutta. Viiraosan listakengän vedenpoiston todettiin aiheuttavan merkittäviä sakeus- ja retentiohäiriöitä, mikäli sen avulla poistettavan kiintoaineen virtaus tuplaantuisi. Viiraretention säädön todettiin estävän häiriöiden kierron prosessissa, mutta siirtävän ne suoraan rainaan. Retention säädön eikuitenkaan todettu olevan suoranainen häiriön lähde.
Resumo:
A change in paradigm is needed in the prevention of toxic effects on the nervous system, moving from its present reliance solely on data from animal testing to a prediction model mostly based on in vitro toxicity testing and in silico modeling. According to the report published by the National Research Council (NRC) of the US National Academies of Science, high-throughput in vitro tests will provide evidence for alterations in"toxicity pathways" as the best possible method of large scale toxicity prediction. The challenges to implement this proposal are enormous, and provide much room for debate. While many efforts address the technical aspects of implementing the vision, many questions around it need also to be addressed. Is the overall strategy the only one to be pursued? How can we move from current to future paradigms? Will we ever be able to reliably model for chronic and developmental neurotoxicity in vitro? This paper summarizes four presentations from a symposium held at the International Neurotoxicology Conference held in Xi"an, China, in June 2011. A. Li reviewed the current guidelines for neurotoxicity and developmental neurotoxicity testing, and discussed the major challenges existing to realize the NCR vision for toxicity testing. J. Llorens reviewed the biology of mammalian toxic avoidance in view of present knowledge on the physiology and molecular biology of the chemical senses, taste and smell. This background information supports the hypothesis that relating in vivo toxicity to chemical epitope descriptors that mimic the chemical encoding performed by the olfactory system may provide a way to the long term future of complete in silico toxicity prediction. S. Ceccatelli reviewed the implementation of rodent and human neural stem cells (NSCs) as models for in vitro toxicity testing that measures parameters such as cell proliferation, differentiation and migration. These appear to be sensitive endpoints that can identify substances with developmental neurotoxic potential. C. Sun ol reviewed the use of primary neuronal cultures in testing for neurotoxicity of environmental pollutants, including the study of the effects of persistent exposures and/or in differentiating cells, which allow recording of effects that can be extrapolated to human developmental neurotoxicity.
Resumo:
PURPOSE: Determine the effect of repeated intravitreal injections of ranibizumab (0.5 mg; 0.05 ml) on retrobulbar blood flow velocities (BFVs) using ultrasound imaging quantification in twenty patients with exudative age-related macular degeneration treated for 6 months. METHODS: Visual acuity (ETDRS), central macular thickness (OCT), peak-systolic, end-diastolic and mean-BFVs in central retinal (CRA), temporal posterior ciliary (TPCA) and ophthalmic (OA) arteries were measured before, 2 days, 3 weeks and 6 months after the first injection. Patients were examined monthly and received 1-5 additional injections depending on ophthalmologic examination results. RESULTS: Six months after the first injection, a significant increase in visual acuity 50.9 ± 25.9 versus 44.4 ± 21.7 (p < 0.01) and decrease in mean central macular thickness 267 ± 74 versus 377 ± 115 μm (p < 0.001) were observed compared to baseline. Although mean-BFVs decreased by 16%±3% in CRA and 20%±5% in TPCA (p < 0.001) 2 days after the first injection, no significant change was seen thereafter. Mean-BFVs in OA decreased by 19%±5% at week 3 (p < 0.001). However, the smallest number of injections (two injections) was associated with the longest time interval between the last injection and month 6 (20 weeks) and with the best return to baseline levels for mean-BFVs in CRA, suggesting that ranibizumab had reversible effects on native retinal vascular supply after its discontinuation. Moreover, a significant correlation between the number of injections and percentage of changes in mean-BFVs in CRA was observed at month 6 (R = 0.74, p < 0.001) unlike TPCA or OA. CONCLUSION: Ranibizumab could impair the native choroidal and retinal vascular networks, but its effect seems reversible after its discontinuation.