970 resultados para small-signal angular stability
Resumo:
One Plus Sequential Air Sampler—Partisol was placed in a small village (Foros de Arrão) in central Portugal to collect PM10 (particles with an aerodynamic diameter below 10 μm), during the winter period for 3 months (December 2009–March 2010). Particles masses were gravimetrically determined and the filters were analyzed by instrumental neutron activation analysis to assess their chemical composition. The water-soluble ion compositions of the collected particles were determined by Ion-exchange Chromatography. Principal component analysis was applied to the data set of chemical elements and soluble ions to assess the main sources of the air pollutants. The use of both analytical techniques provided information about elemental solubility, such as for potassium, which was important to differentiate sources.
Resumo:
A two terminal optically addressed image processing device based on two stacked sensing/switching p-i-n a-SiC:H diodes is presented. The charge packets are injected optically into the p-i-n sensing photodiode and confined at the illuminated regions changing locally the electrical field profile across the p-i-n switching diode. A red scanner is used for charge readout. The various design parameters and addressing architecture trade-offs are discussed. The influence on the transfer functions of an a-SiC:H sensing absorber optimized for red transmittance and blue collection or of a floating anode in between is analysed. Results show that the thin a-SiC:H sensing absorber confines the readout to the switching diode and filters the light allowing full colour detection at two appropriated voltages. When the floating anode is used the spectral response broadens, allowing B&W image recognition with improved light-to-dark sensitivity. A physical model supports the image and colour recognition process.
Resumo:
Results on the use of a double a-SiC:H p-i-n heterostructure for signal multiplexing and demultiplexing applications in the visible range are presented. Pulsed monochromatic beams together (multiplexing mode), or a single polychromatic beam (demultiplexing mode) impinge on the device and are absorbed, accordingly to their wavelength. Red, green and blue pulsed input channels are transmitted together, each one with a specific transmission rate. The combined optical signal is analyzed by reading out, under different applied voltages, the generated photocurrent. Results show that in the multiplexing mode the output signal is balanced by the wavelength and transmission rate of each input channel, keeping the memory of the incoming optical carriers. In the demultiplexing mode the photocurrent is controlled by the applied voltage allowing regaining the transmitted information. A physical model supported by a numerical simulation gives insight into the device operation.
Resumo:
The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to increased interest in in vivo small animal imaging. Small animal imaging has been applied frequently to the imaging of small animals (mice and rats), which are ubiquitous in modeling human diseases and testing treatments. The use of PET in small animals allows the use of subjects as their own control, reducing the interanimal variability. This allows performing longitudinal studies on the same animal and improves the accuracy of biological models. However, small animal PET still suffers from several limitations. The amounts of radiotracers needed, limited scanner sensitivity, image resolution and image quantification issues, all could clearly benefit from additional research. Because nuclear medicine imaging deals with radioactive decay, the emission of radiation energy through photons and particles alongside with the detection of these quanta and particles in different materials make Monte Carlo method an important simulation tool in both nuclear medicine research and clinical practice. In order to optimize the quantitative use of PET in clinical practice, data- and image-processing methods are also a field of intense interest and development. The evaluation of such methods often relies on the use of simulated data and images since these offer control of the ground truth. Monte Carlo simulations are widely used for PET simulation since they take into account all the random processes involved in PET imaging, from the emission of the positron to the detection of the photons by the detectors. Simulation techniques have become an importance and indispensable complement to a wide range of problems that could not be addressed by experimental or analytical approaches.
Resumo:
The dynamics of a cylinder rolling on a horizontal plane acted on by an external force applied at an arbitrary angle is studied with emphasis on the directions of the acceleration of the centre-of-mass and the angular acceleration of the body. If rolling occurs without slipping, there is a relationship between the directions of these accelerations. If the linear acceleration points to the right, then the angular acceleration is clockwise. On the other hand, if it points to the left, then the angular acceleration is counterclockwise. In contrast, if rolling and slipping occurs, the direction of the linear acceleration does not determine the direction of the angular acceleration. For example, the linear acceleration may point to the right and the angular acceleration clockwise or counterclockwise depending on the external force orientation and point of application.
Resumo:
We study the implications for two-Higgs-doublet models of the recent announcement at the LHC giving a tantalizing hint for a Higgs boson of mass 125 GeV decaying into two photons. We require that the experimental result be within a factor of 2 of the theoretical standard model prediction, and analyze the type I and type II models as well as the lepton-specific and flipped models, subject to this requirement. It is assumed that there is no new physics other than two Higgs doublets. In all of the models, we display the allowed region of parameter space taking the recent LHC announcement at face value, and we analyze the W+W-, ZZ, (b) over barb, and tau(+)tau(-) expectations in these allowed regions. Throughout the entire range of parameter space allowed by the gamma gamma constraint, the numbers of events for Higgs decays into WW, ZZ, and b (b) over bar are not changed from the standard model by more than a factor of 2. In contrast, in the lepton-specific model, decays to tau(+)tau(-) are very sensitive across the entire gamma gamma-allowed region.
Resumo:
A tese estrutura-se em dois ensaios versando temas distintos, se bem que entre eles se possam perceber algumas afinidades decorrentes do facto de ambos se subsumirem à análise de diferentes tipos de investimento em capital humano: a formação profissional e a formação académica superior. No primeiro ensaio, aborda-se a questão da avaliação do impacto de diferentes tipos de formação profissional sobre os salários, a estabilidade da relação contratual trabalhador-empregador e a empregabilidade, em Portugal, por recurso a uma metodologia de estimação semiparamétrica, mais especificamente, através de uma metodologia de enlaçamento baseado em índices de propensão aplicada aos dados do Inquérito ao Emprego do INE, relativos aos anos de 1998 a 2001. Quanto aos impactos salariais, conclui-se que a formação obtida nas empresas será a mais compensadora, mas os restantes tipos de formação também propiciarão ganhos salariais, sendo que a formação obtida nas escolas ou centros de formação profissional será aquela com efeitos menos expressivos. Quanto ao efeito sobre a empregabilidade, as estimativas obtidas apontam para a conclusão de que a formação profissional potenciará o abandono da inactividade, mas não garantidamente o emprego, verificando-se mesmo que a formação recebida nas escolas e centros de formação profissional conduzirá, mais provavelmente, ao desemprego, se bem que, para uma certa fracção de desempregados, o sentido da causalidade possa ser inverso. O segundo ensaio versa a decomposição, da média condicional e por quantis, do diferencial salarial entre homens e mulheres específico do universo dos diplomados do ensino superior, em Portugal (dados do 1.º Inquérito de Percurso aos Diplomados do Ensino Superior realizado em 2001), por forma a apurar o grau de discriminação por género nele indiciado. Usando a metodologia de Machado-Mata e, em alternativa, a metodologia de enlaçamento baseado em índices de propensão, dir-se-ia que, no sector público, a discriminação salarial por género, a existir, será reduzida, i.e. o diferencial salarial observado explicar se á quase integralmente pelas diferenças entre os atributos produtivos dos homens e das mulheres. Diferentemente, no sector empresarial, a discriminação é potencialmente ponderosa. Especial atenção é dedicada ao contributo da área de formação escolar para a explicação do diferencial salarial.
Resumo:
Captopril, an inhibitor of angiotensin converting enzyme (ACE), is used to treat medical conditions like hypertension and heart failure, and it is usually administered in tablet form for adults. Since this dosage form is not recommended for infants and children up to 6 years, hospital pharmacies have to prepare liquid formulations for oral administration of captopril. Traditionally, concentration of captopril used in the formulations is 1mg/ml. The problem is that captopril is prone to oxidation, and its stability in solution is affected by pH, concentration of captopril, the presence of oxygen or metal ions. The influence of different formulation ingredients on the properties of physical and chemical stability of captopril in liquid preparations has been evaluated. Main of the study: to evaluate the stability of captopril for 30 days when formulated in a 1 mg/ml suspension adjuvanted with citric acid.
Resumo:
A doença de Machado-Joseph (DMJ) ou ataxia espinocerebelosa do tipo 3 (SCA3), conhecida por ser a mais comum das ataxias hereditárias dominantes em todo o mundo, é uma doença neurodegenerativa autossómica dominante que leva a uma grande incapacidade motora, embora sem alterar o intelecto, culminando com a morte do doente. Atualmente não existe nenhum tratamento eficaz para esta doença. A DMJ é resultado de uma alteração genética causada pela expansão de uma sequência poliglutamínica (poliQ), na região C-terminal do gene que codifica a proteína ataxina-3 (ATXN3). Os mecanismos celulares das doenças de poliglutaminas que provocam toxicidade, bem como a função da ATXN3, não são ainda totalmente conhecidos. Neste trabalho, usamos, pela sua simplicidade e potencial genético, um pequeno animal invertebrado, o nemátode C. elegans, com o objetivo de identificar fármacos eficazes para o combate contra a patogénese da DMJ, analisando simultaneamente o seu efeito na agregação da ATXN3 mutante nas células neuronais in vivo e o seu impacto no comportamento motor dos animais. Este pequeno invertebrado proporciona grandes vantagens no estudo dos efeitos tóxicos de proteínas poliQ nos neurónios, uma vez que a transparência das suas 959 células (das quais 302 são neurónios) facilita a deteção de proteínas fluorescentes in vivo. Para além disso, esta espécie tem um ciclo de vida curto, é económica e de fácil manutenção. Neste trabalho testámos no nosso modelo transgénico da DMJ com 130Qs em C.elegans dois compostos potencialmente moduladores da agregação da ATXN3 mutante e da resultante disfunção neurológica, atuando pela via da autofagia. De modo a validar a possível importância terapêutica da ativação da autofagia os compostos candidatos escolhidos foram o Litío e o análogo da Rapamicina CCI-779, testados independentemente e em combinação. A neuroproteção conferida pelo Litío e pelo CCI-779 independentemente sugere que o uso destes fármacos possa ser considerado uma boa estratégia como terapia para a DMJ, a testar em organismos evolutivamente mais próximos do humano. A manipulação da autofagia, segundo vários autores, parece ser benéfica e pode ser a chave para o desenvolvimento de novos tratamentos para várias doenças relacionadas com a agregação proteica e o envelhecimento.
Resumo:
This work addresses the present-day (<100 ka) mantle heterogeneity in the Azores region through the study of two active volcanic systems from Terceira Island. Our study shows that mantle heterogeneities are detectable even when "coeval" volcanic systems (Santa Barbara and Fissural) erupted less than 10 km away. These volcanic systems, respectively, reflect the influence of the Terceira and D. Joao de Castro Bank end-members defined by Beier et at (2008) for the Terceira Rift Santa Barbara magmas are interpreted to be the result of mixing between a HIMU-type component, carried to the upper mantle by the Azores plume, and the regional depleted MORB magmas/source. Fissural lavas are characterized by higher Ba/Nb and Nb/U ratios and less radiogenic Pb-206/Pb-204, Nd-143/Nd-144 and Hf-176/Hf-177, requiring the small contribution of delaminated sub-continental lithospheric mantle residing in the upper mantle. Published noble gas data on lavas from both volcanic systems also indicate the presence of a relatively undegassed component, which is interpreted as inherited from a lower mantle reservoir sampled by the ascending Azores plume. As inferred from trace and major elements, melting began in the garnet stability field, while magma extraction occurred within the spinel zone. The intra-volcanic system's chemical heterogeneity is mainly explained by variable proportions of the above-mentioned local end-members and by crystal fractionation processes. (C) 2011 Elsevier By. All rights reserved.
Resumo:
Myocardial perfusion-gated-SPECT (MP-gated-SPECT) imaging often shows radiotracer uptake in abdominal organs. This accumulation interferes frequently with qualitative and quantitative assessment of the infero-septal region of myocardium. The objective of this study is to evaluate the effect of ingestion of different fat content on the reduction of extra-myocardial uptake and to improve MP-gated-SPECT image quality. In this study, 150 patients (65 ^ 18 years) who were referred for MP-gated-SPECT underwent a 1-day-protocol including imaging after stress (physical or pharmacological) and resting conditions. All patients gave written informed consent. Patients were subdivided into five groups: GI, GII, GIII, GIV and GV. In the first four groups, patients ate two chocolate bars with different fat content. Patients in GV – control group (CG) – had just water. Uptake indices (UI) of myocardium (M)/liver(L) and M/stomach–proximal bowel(S) revealed lower UI of M/S at rest in all groups. Both stress and rest studies using different food intake indicate that patients who ate chocolate with different fat content showed better UI of M/L than the CG. The UI of M/L and M/S of groups obtained under physical stress are clearly superior to that of groups obtained under pharmacological stress. These differences are only significant in patients who ate high-fat chocolate or drank water. The analysis of all stress studies together (GI, GII, GIII and GIV) in comparison with CG shows higher mean ranks of UI of M/L for those who ate high-fat chocolate. After pharmacological stress, the mean ranks of UI of M/L were higher for patients who ate high- and low-fat chocolate. In conclusion, eating food with fat content after radiotracer injection increases, respectively, the UI of M/L after stress and rest in MP-gated-SPECT studies. It is, therefore, recommended that patients eat a chocolate bar after radiotracer injection and before image acquisition.
Resumo:
A presença de sistemas eletrónicos nos veículos automóveis tem vindo a aumentar de forma considerável nos últimos 30 anos, tornando possível o aumento dos padrões de eficiência, segurança e conforto dos mesmos. Os sistemas de acionamento automático dos limpa-para-brisas, baseados em sensores de chuva óticos, têm registado um crescimento quase exponencial nos últimos 10 a 15 anos; no ano 2000, apenas 5 % dos veículos novos produzidos na Europa estavam equipados com este sistema, hoje é um equipamento amplamente difundido na oferta automóvel existente. O presente trabalho consistiu no estudo de uma solução para deteção de chuva em veículos automóveis com a aplicação de um sensor piezoelétrico, tendo em vista a obtenção de uma solução mais versátil e aplicável em vários pontos do veículo. As reduzidas dimensões, a elevada sensibilidade do sensor e a facilidade de aplicação nas superfícies de ensaio foram fatores que motivaram a escolha deste tipo de equipamento como elemento sensorial. As hipóteses definidas para o procedimento laboratorial basearam-se nas conclusões obtidas em estudos anteriormente desenvolvidos no campo dos sensores de chuva para automóveis e nas capacidades dos materiais piezoelétricos para medição de pluviosidade. Os sensores foram instalados sob as superfícies do veículo que apresentavam, simultaneamente, uma maior exposição à pluviosidade, quando este está em movimento, e um menor risco de sofrer danos. Os resultados obtidos permitiram concluir que a utilização deste tipo de sensores permite detetar elevados níveis de pluviosidade e em superfícies com considerável capacidade de deformação elástica. A sua implementação futura em veículos automóveis exige mais algum trabalho de melhoria dos processos de fixação dos sensores e do condicionamento de sinal utilizados.
Resumo:
OBJECTIVE: Studies on the aspects of HIV infection in small Brazilian municipalities are invaluable to appropriately design control strategies, better allocate resources, and improve health care services. The objective of the study was to assess the clinical and epidemiological aspects of HIV infection in a small municipality. METHODS: A descriptive study was carried out in Miracema, a small municipality in the northwestern area of the state of Rio de Janeiro, Brazil, between July 1999 and December 2003. All HIV-infected adult patients followed up at the local HIV/AIDS Program were included. Clinical and epidemiologic characteristics were prospectively assessed through standardized questionnaires. RESULTS: A total of 65 adult patients who attended the local HIV/AIDS Program were analyzed. Most (34) were women (male to female ratio: 0.9). An absolute predominance of patients who were born in Miracema or neighboring municipalities (94%), lived in Miracema (90.7%), were single (70.8%), attributed the acquisition of HIV infection to unprotected heterosexual intercourse (72.3%) and had a past history of snorting cocaine (27.7) was found Central nervous system disorders (including five cases of cryptococcal meningitis) and acute pulmonary pneumocystosis-like respiratory failure were major causes of morbidity. Most patients (56.9%) were at presented in advanced stages of HIV infection. CONCLUSIONS: The predominance of patients on advanced stages of HIV infection suggest the existence of a large pool of undiagnosed cases in the community. A major feature of the cohort was an inverted male to female ratio. Further investigations over a broader geographic area are urgently needed for better understanding the clinical and epidemiological characteristics of HIV infection in small Brazilian municipalities and rural areas.
Resumo:
The analysis of the Higgs boson data by the ATLAS and CMS Collaborations appears to exhibit an excess of h -> gamma gamma events above the Standard Model (SM) expectations, whereas no significant excess is observed in h -> ZZ* -> four lepton events, albeit with large statistical uncertainty due to the small data sample. These results (assuming they persist with further data) could be explained by a pair of nearly mass-degenerate scalars, one of which is an SM-like Higgs boson and the other is a scalar with suppressed couplings to W+W- and ZZ. In the two-Higgs-doublet model, the observed gamma gamma and ZZ* -> four lepton data can be reproduced by an approximately degenerate CP-even (h) and CP-odd (A) Higgs boson for values of sin (beta - alpha) near unity and 0: 70 less than or similar to tan beta less than or similar to 1. An enhanced gamma gamma signal can also arise in cases where m(h) similar or equal to m(H), m(H) similar or equal to m(A), or m(h) similar or equal to m(H) similar or equal to m(A). Since the ZZ* -> 4 leptons signal derives primarily from an SM-like Higgs boson whereas the gamma gamma signal receives contributions from two (or more) nearly mass-degenerate states, one would expect a slightly different invariant mass peak in the ZZ* -> four lepton and gamma gamma channels. The phenomenological consequences of such models can be tested with additional Higgs data that will be collected at the LHC in the near future. DOI: 10.1103/PhysRevD.87.055009.
Resumo:
Introdução: A artroplastia total do ombro é largamente aceite como tratamento para uma variedade de patologias do ombro com dor persistente e perda acentuada da funcionalidade. Em termos globais, os resultados obtidos após a intervenção cirúrgica são bastante bons, parecendo estar, no entanto, condicionados com a patologia subjacente e a qualidade da coifa dos rotadores. Objectivo: Pretende-se com este trabalho descrever e avaliar a eficácia de um plano de intervenção numa prótese total do ombro com integridade da coifa dos rotadores. Metodologia: Paciente sexo feminino, 61 anos, reformada, com dor acentuada no ombro esquerdo desde há três anos, submetida a uma cirurgia de colocação de prótese total do ombro. Apresentava limitação da amplitude articular, diminuição da força, alteração do ritmo escapulo-umeral e ligeira incapacidade funcional. Cinco semanas após a cirurgia, iniciou sessões diárias de fisioterapia durante 12 semanas. A intervenção incluiu a aplicação de modalidades anti-álgicas, mobilização articular, fortalecimento muscular e reeducação neuromuscular. Foi avaliada em quatro momentos: antes da intervenção (M1), 4 (M2), 7 (M3) e 12 (M4) semanas após. Resultados: A dor diminuiu de 4 para 0 (END) no final de 7 semanas e as amplitudes articulares passivas aproximaram-se dos valores definidos pelo protocolo com a flexão/elevação anterior a evoluir de 90º para 130º; a abdução/elevação lateral de 80º para 110º e a rotação medial de 35º para 70º. A força muscular inicial era de 3 nos grupos musculares flexores, extensores e rotadores do ombro atingindo no final grau 4. O ritmo escapulo-umeral demonstrou assincronia durante a elevação do ombro na primeira avaliação, ficando quase normalizado no final das sessões. Quanto à funcionalidade, antes da intervenção o score obtido foi de 30.8 atingindo um valor de 11.6 no final das sessões de tratamento. Conclusão: Após 12 semanas de tratamento, os objectivos delineados foram praticamente atingidos, uma vez que a utente já não refere dor no ombro e apresenta uma boa capacidade funcional, apesar de apresentar ligeiras diferenças nas amplitudes articulares e força muscular esperadas, apontando para o sucesso do protocolo de tratamento aplicado.