984 resultados para pressão intra-ocular


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The patient with anophthalmia may present feelings of inferiority and rejection. Knowing his/her needs and expectations contribute to a better technical intervention. Purpose: To elaborate a questionnaire of the psychosocial profile of the patient with anophthalmia with indication of ocular prosthesis. Methods: An exploratory research was used to elaborate the questionnaire, by means of a guided interview followed by writing down what was said by the interviewees, who were adult patients of the Bucco-Maxillo-Facial Prosthesis Center of FOSJC - UNESP. The guided interview was made up of 14 items directly related to the future outline of the profile. Each item of the interview resulted in questions of the questionnaire, which was pretested twice before reaching its final version. Results: The patients reported, in the exploratory research, unpleasant feelings with the loss of the eye; relationship shyness; expectations regarding surgery and prosthesis use; a wish to receive explanations and to hold their opinion about the treatment. The questionnaire of the psychosocial profile of the patient with anophthalmia with indication of ocular prosthesis is, therefore, made of 43 questions divided into 5 blocks in order to aid the comprehension of the inquired aspects and to facilitate both the computation of data and discussion, and also to improve the selection of questions according to the objective of the researcher or professional. Conclusions: It was concluded that the questionnaire was viable, can be used in full or by selecting blocks and provide a panorama of the patient's history related to the problem he/she faces, from the loss of the ocular globe to the confection of the prosthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objective: It has been shown that aerobic exercise is useful to reduce arterial pressure, however, the effectiveness of an exercise program is still controversial and not very well analyzed among populations with low-income. The objective of the present study was to set up an individualized physical fitness program - Projeto Hipertensão - focused on hypertensive people, patients from a Health Basic Unit (HBU) and, after that, to investigate the effects of this program on physical fitness, metabolic profile and pressure levels. Methods: Sixteen hypertensive women (56 ± 3yrs) under regular pharmacological treatment underwent 4 months of a supervised aerobic and stretching exercise program (3 sessions/wk, 90 min/session, 60% of V̇O 2 max). Several physical and metabolic variables were compared before and after 4 months of training. Results: Training significantly reduced systolic arterial pressure (SAP, -6%), improved cardio-respiratory fitness (+42% of V̇O2max), flexibility (+11%) and plasma glucose content (-4%). BMI and % fat did not change. Besides modifying metabolic profile, it was found that training presented significant correlations between individual initial values of cholesterol total level (CT), high density lipoprotein (HDL-C) and low density lipoprotein (LDL-C) and its responses after exercise. Conclusions: The study shows that exercise programs can be personalized for hypertensive patients from a HBU and confirms the effectiveness of exercise on AP, physical fitness, flexibility and lipid profile on hypertensive patients. The expressive reduction of AP in hypertensive subjects suggests that this exercise intervention should be emphasized on other health centers which assist low-income population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical excitation of Ce3+-doped SnO2 thin films, obtained by the sol-gel-dip-coating technique, is carried out and the effects on electrical transport are evaluated. Samples are doped with O. lat% of Ce, just above the saturation limit. The excitation is done with an intensity-controlled halogen-tungsten lamp through an interference filter, yielding an excitation wavelength of 513nm, 9 nm wide (width at half intensity peak). Irradiation at low temperature (25K) yields a conductivity increase much lower than above bandgap light. Such a behavior assures the ionization of intra-bandgap defect levels, since the filter does not allow excitation of electron-hole pairs, what would happen only in the UV range (below about 350nm). The decay of intra-bandgap excited levels in the range 250-320 K is recorded, leading to a temperature dependent behavior related to a thermally excited capture cross section for the dominating defect level. © 2008 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess color alteration of the paints used for iris painting in artificial eyes. Five disks of heat cured acrylic resin were confectioned by microwave energy for each paint analyzed, in a total of 40 specimens. Each specimen consisted of a colorless acrylic resin disk and another of equal size, of scleral white colored acrylic resin, with the painting interposed between the two disks. The specimens were submitted to an accelerated aging process in a chamber under ultraviolet radiation for 1,008 hours. To assess color variation, a reflective spectrophotometer was used. The results were statistically analyzed by ANOVA and the Tukey test (p < 0.05). All the paints underwent chromatic alteration. The oil paint presented the highest resistance to accelerated aging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the roughness of colorless ocular button and four brands of colorless acrylic resins designed to fabricate ocular prosthesis as a function of weathering (1008 h) and different thickness (1 and 3.5 mm). Materials and methods: One-hundred-and-twenty specimens were fabricated and distributed in 12 groups. The analysis was carried out by means of digital roughness meter. Results: Data were analyzed statistically by ANOVA and Tukey test at 1% significance. The results showed that there was no statistically significant difference after the weathering period. Both the Vipi Cril acrylic resin with 3.5 mm in thickness and ocular button with 1 mm in thickness presented the lowest roughness values (0.12. Ra). Conclusion: The roughness of the acrylic resins and the ocular button was not affect by the weathering of 1008 h. However, the thickness of the specimens proved to have a major influence on roughness property. © 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Obstructive sleep apnea syndrome is related to cardiopulmonary complications in children. It is important to know its patophysiology and possible complications to help reduce risks in this group. Aims: To report three cases of severe cardiorespiratory complications of obstructive sleep apnea managed in the intensive care unit (ICU). Case report: Two children with no previous diagnosis of obstructive sleep apnea syndrome suffered acute congestive heart failure and acute lung oedema with need of ICU and improved after adenotonsillectomy. In a third case, the patient had acute lung oedema as a complication after adenotonsillectomy. Conclusions: Paediatricians and otolaryngologists must be aware of the clinical manifestations of severe sleep apnea. Early referring to treatment and special attention at pre and post surgical periods are essentials to avoid serious complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Model: Prevalence study. Objectives: To evaluate the presence of self-reported hypertension to compare with blood pressure measurements. Besides, this work investigated health information level of workers and if the job position has any influence on blood pressure (BP). Methods: This study evaluated 349 health workers (44±10 years old) from Bauru and Jau cities, who answered some questions about history of health condition, use of medicines, past surgeries as well as social, scholar and physical conditions and had their blood pressure measured. Each subject selfreported as normotensive or hypertensive. Values of systolic ≥ 140 mmHg and/or diastolic PA ≥ 90 mmHg were considered elevated. Among the health workers evaluated, 198 were submitted to anthropometric and biochemical evaluations. Values are presented as means ± SD and frequency of distribution. It was used T-student test (p<0.05). Results: From all workers evaluated only 16% self-reported as hypertensive, which 56% presented high BP, however 91% used to take antihypertensive medicines. Among the 84% who self-reported as normotensive, 24% presented high BP and 8% used to take medicines. Although most of the employees of each section self-reported as normotensive, more than a half presented high BP and which was more common in the health's section (76.3%). Conclusion: These results suggest that besides the majority of the employees self-reported as normotensive, an elevated number of health workers presented high blood pressure and used to take medicines inappropriately, which indicates that they did not have enough knowledge about their health. Furthermore, it was observed that Health Section presented the higher blood pressure values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the Morrinhos region, Goiás state, Brazil, the rocks of the Araxá Group have mineral assemblages related to the metamorphic peak which occurred in this region and is typical of the amphibolite facies (kyanite zone). These rocks are associated with the initial stage of the main ductile deformation that occurred in this area. Thermobarometric calculations, including the associations, garnet + plagioclase + biotite + muscovite; garnet + plagioclase +biotite + muscovite + kyanite; garnet + plagioclase + biotite + muscovite + amphibole, with quartz in excess, indicate that the metamorphic peak occurred at temperatures of approximately 610°C and pressures in the order of 10 kbar. The P-T path is probably clockwise and is in agreement with the tectonic conditions observed in collisional settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Making an artificial iris with an aesthetically acceptable color is an important aspect of ocular rehabilitation. This work evaluated the influence of different disinfecting solutions on changes to the color of artificial irises used in ocular prostheses. Fifty samples simulating ocular prostheses were produced with cobalt blue artificial irises and divided (n = 10) according to the disinfectant used: neutral soap, Opti-free, Efferdent, 1% hypochlorite, and 4% chlorhexidine. The samples were disinfected for 120 days and subjected to a color readings by spectrophotometry, using the CIE L*a*b* system, before the disinfection period (B), after 60 days of disinfectant exposure (T 1), and after 120 days of disinfectant exposure (T 2). Color differences (ΔE) were calculated for the intervals between T 1 and B (T 1B), and between T 2 and B (T 2B). The data were evaluated by analysis of variance and the Tukey Honestly Significantly Different (α = 0.05). All disinfectant groups exhibited color changes. The mean color change observed for all groups overall during T 2B (ΔE = 3.51) was significantly greater than that observed during T 1B (ΔE = 2.10). All groups exhibited greater color change for the b* values when compared to the a* and L* values. There were no significant differences between the disinfectant groups. It can be concluded that the time period of disinfection and storage significantly affected the stability of artificial iris color, independent of the disinfectant used. © 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the expression of the protein annexin A1 (ANXA1), a potent endogenous regulator of the inflammatory process, in ocular toxoplasmosis. Methods: C57BL/6 female mice were infected using intravitreal injections of either 10 6 tachyzoites of Toxoplasma gondii (RH strain; T. gondii) or PBS only (control groups). After 24, 48, and 72 h, animals were sacrificed and their eyes were harvested for histopathological, immunohistochemical, and ultrastructural immunocytochemical analysis of ANXA1. Human retinal pigment epithelial (RPE) cells (ARPE-19) were infected in vitro with T. gondii and collected after 60, 120, 240 min, and 24 h. Results: Compared with non-infected eyes, an intense inflammatory response was observed in the anterior (24 h after infection) and posterior segments (72 h after infection) of the infected eye, characterized by neutrophil infiltration and by the presence of tachyzoites and their consequent destruction along with disorganization of normal retina architecture and RPE vacuolization. T. gondii infection was associated with a significant increase of ANXA1 expression in the neutrophils at 24, 48, and 72 h, and in the RPE at 48 and 72 h. In vitro studies confirmed an upregulation of ANXA1 levels in RPE cells, after 60 and 120 min of infection with T. gondii. Conclusions: The positive modulation of endogenous ANXA1 in the inflammatory and RPE cells during T. gondii infection suggests that this protein may serve as a therapeutic target in ocular toxoplasmosis. © 2012 Molecular Vision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the improvement in psychosocial awareness of anophthalmic patients wearing ocular prostheses and its relationship with demographic characteristics, factors of loss/treatment, social activity, and relationship between professional and patient. Surveys including a form for evaluation of psychosocial pattern were conducted with 40 anophthalmic patients rehabilitated with ocular prosthesis at the Center of Oral Oncology in the authors' dental school from January 1998 to November 2010. The improvement in psychosocial awareness was assessed by comparing the perception of some feelings reported in the period of eye loss and currently. Wilcoxon tests were applied for comparison of patients' perception between the periods. χ2 tests were used to assess the relationship between the improvement in psychosocial awareness and the variables of the study. In addition, the logistic regression model measured this relationship with the measure of odds ratio. The feelings of shame, shyness, preoccupation with hiding it, sadness, insecurity and fear were significant for improvement in psychosocial awareness. It was concluded that the anophthalmic patients wearing an ocular prosthesis has significant improvement in psychosocial awareness after rehabilitation. © 2012 International Association of Oral and Maxillofacial Surgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ocular prosthesis materials should have specific properties for their indication and durability; therefore, it is important to investigate their physical behaviour when affected by several disinfectants. Objectives: This study evaluated the influence of different disinfecting solutions on the microhardness and surface roughness of acrylic resins for ocular prosthesis. Materials and Methods: Fifty samples simulating ocular prostheses were fabricated with N1 resin and colourless resin and divided (n = 10) according to the disinfectant used: neutral soap, Opti-free, Efferdent, 1% hypochlorite (HYC) and 4% chlorhexidine (CHX). Samples were stored in saline solution at 37°C and disinfected during 120 days. Both microhardness and roughness were investigated before, after 60 days and 120 days of disinfection and storage. Microhardness was measured using a microhardner and the roughness with a roughness device. Results: N1 resin showed lower microhardness when compared with colourless resin (p < 0.05). HYC and CHX groups exhibited the highest change of microhardness and roughness values (p < 0.05). An increase in roughness and reduction in microhardness of ocular acrylic resins were observed after both periods of disinfection and storage (p < 0.05). Conclusion: Both disinfection/storage periods affected the microhardness and roughness values of the samples. © 2012 The Gerodontology Society and John Wiley & Sons A/S.