875 resultados para measurement of power loss


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurements of the self coupling between bosons are important to test the electroweak sector of the Standard Model (SM). The production of pairs of Z bosons through the s-channel is forbidden in the SM. The presence of physics, beyond the SM, could lead to a deviation of the expected production cross section of pairs of Z bosons due to the so called anomalous Triple Gauge Couplings (aTGC). Proton-proton data collisions at the Large Hadron Collider (LHC) recorded by the ATLAS detector at a center of mass energy of 8 TeV were analyzed corresponding to an integrated luminosity of 20.3 fb-1. Pairs of Z bosons decaying into two electron-positron pairs are searched for in the data sample. The effect of the inclusion of detector regions corresponding to high values of the pseudorapidity was studied to enlarge the phase space available for the measurement of the ZZ production. The number of ZZ candidates was determined and the ZZ production cross section was measured to be: rn7.3±1.0(Stat.)±0.4(Sys.)±0.2(lumi.)pb, which is consistent with the SM expectation value of 7.2±0.3pb. Limits on the aTGCs were derived using the observed yield, which are twice as stringent as previous limits obtained by ATLAS at a center of mass energy of 7 TeV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The future goal of modern physics is the discovery of physics beyond the Standard Model. One of the most significant hints for New Physics can be seen in the anomalous magnetic moment of the muon - one of the most precise measured variables in modern physics and the main motivation of this work. This variable is associated with the coupling of the muon, an elementary particle, to an external electromagnetic field and is defined as a = (g - 2)/2, whereas g is the gyromagnetic factor of the muon. The muon anomaly has been measured with a relative accuracy of 0.5·10-6. However, a difference between the direct measurement and the Standard Model prediction of 3.6 standard deviations can be observed. This could be a hint for the existence of New Physics. Unfortunately, it is, yet, not significant enough to claim an observation and, thus, more precise measurements and calculations have to be performed.rnThe muon anomaly has three contributions, whereas the ones from quantum electrodynamics and weak interaction can be determined from perturbative calculations. This cannot be done in case of the hadronic contributions at low energies. The leading order contribution - the hadronic vacuum polarization - can be computed via a dispersion integral, which needs as input hadronic cross section measurements from electron-positron annihilations. Hence, it is essential for a precise prediction of the muon anomaly to measure these hadronic cross sections, σ(e+e-→hadrons), with high accuracy. With a contribution of more than 70%, the final state containing two charged pions is the most important one in this context.rnIn this thesis, a new measurement of the σ(e+e-→π+π-) cross section and the pion form factor is performed with an accuracy of 0.9% in the dominant ρ(770) resonance region between 600 and rn900 MeV at the BESIII experiment. The two-pion contribution to the leading-order (LO) hadronic vacuum polarization contribution to (g - 2) from the BESIII result, obtained in this work, is computed to be a(ππ,LO,600-900 MeV) = (368.2±2.5stat±3.3sys)·10-10. With the result presented in this thesis, we make an important contribution on the way to solve the (g - 2) puzzle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La sezione d’urto totale adronica gioca un ruolo fondamentale nel programma di fisica di LHC. Un calcolo di questo parametro, fondamentale nell’ambito della teoria delle interazioni forti, non é possibile a causa dell’inapplicabilità dell’approccio perturbativo. Nonostante ciò, la sezione d’urto può essere stimata, o quanto meno le può essere dato un limite, grazie ad un certo numero di relazioni, come ad esempio il Teorema Ottico. In questo contesto, il detector ALFA (An Absolute Luminosity For ATLAS) sfrutta il Teorema Ottico per determinare la sezione d’urto totale misurando il rate di eventi elastici nella direzione forward. Un tale approccio richiede un metodo accurato di misura della luminosità in condizioni sperimentali difficoltose, caratterizzate da valori di luminosità istantanea inferiore fino a 7 ordini di grandezza rispetto alle normali condizioni di LHC. Lo scopo di questa tesi è la determinazione della luminosità integrata di due run ad alto β*, utilizzando diversi algoritmi di tipo Event-Counting dei detector BCM e LUCID. Particolare attenzione è stata riservata alla sottrazione del fondo e allo studio delle in- certezze sistematiche. I valori di luminosità integrata ottenuti sono L = 498.55 ± 0.31 (stat) ± 16.23 (sys) μb^(-1) and L = 21.93 ± 0.07 (stat) ± 0.79 (sys) μb^(-1), rispettivamente per i due run. Tali saranno forniti alla comunità di fisica che si occupa della misura delle sezioni d’urto protone-protone, elastica e totale. Nel Run II di LHC, la sezione d’urto totale protone-protone sarà stimata con un’energia nel centro di massa di 13 TeV per capire meglio la sua dipendenza dall’energia in un simile regime. Gli strumenti utilizzati e l’esperienza acquisita in questa tesi saranno fondamentali per questo scopo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective of this project is to experimentally demonstrate geometrical nonlinear phenomena due to large displacements during resonant vibration of composite materials and to explain the problem associated with fatigue prediction at resonant conditions. Three different composite blades to be tested were designed and manufactured, being their difference in the composite layup (i.e. unidirectional, cross-ply, and angle-ply layups). Manual envelope bagging technique is explained as applied to the actual manufacturing of the components; problems encountered and their solutions are detailed. Forced response tests of the first flexural, first torsional, and second flexural modes were performed by means of a uniquely contactless excitation system which induced vibration by using a pulsed airflow. Vibration intensity was acquired by means of Polytec LDV system. The first flexural mode is found to be completely linear irrespective of the vibration amplitude. The first torsional mode exhibits a general nonlinear softening behaviour which is interestingly coupled with a hardening behaviour for the unidirectional layup. The second flexural mode has a hardening nonlinear behaviour for either the unidirectional and angle-ply blade, whereas it is slightly softening for the cross-ply layup. By using the same equipment as that used for forced response analyses, free decay tests were performed at different airflow intensities. Discrete Fourier Trasform over the entire decay and Sliding DFT were computed so as to visualise the presence of nonlinear superharmonics in the decay signal and when they were damped out from the vibration over the decay time. Linear modes exhibit an exponential decay, while nonlinearities are associated with a dry-friction damping phenomenon which tends to increase with increasing amplitude. Damping ratio is derived from logarithmic decrement for the exponential branch of the decay.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lo scopo di questa tesi è la misura di sezione d’urto di produzione di coppie top-antitop nel canale adronico. Per la misura sono stati utilizzati i dati raccolti dall’esperimento CMS in collisioni protone-protone ad LHC, con un’energia nel centro di massa pari a 13 TeV. Il campione di dati utilizzato corrisponde ad una luminosità integrata di 2.474 f b^ −1 . L’analisi dati inizia selezionando gli eventi che soddisfano determinate condizioni (e.g. trigger, tagli cinematici, sei o più jet, almeno 2 jet provenienti dall’adronizzazione di due quark bottom) con lo scopo di incrementare la purezza del segnale scartando il più possibile gli eventi di fondo. A seguire, viene ricostruita la massa del quark top usando un fit cinematico. Sulle distribuzioni di tale massa si basa la stima degli eventi di fondo e di segnale. Infine, attraverso un fit di verosimiglianza, si ottiene il valore della sezione d’urto: σ t t ̄ = 893 ± 57 (stat) ± 104 (syst) pb. Questo risultato è in buon accordo con il valore teorico di 832 pb e con altre misure di CMS effettuate in canali differenti.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study deals with the determination of the retentive force between primary and secondary telescopic crowns under clinical conditions. Forty-three combined fixed-removable prostheses with a total of 140 double crowns were used for retention force measurement of the telescopic crowns prior to cementation. The crowns had a preparation of 1-2°. A specifically designed measuring device was used. The retentive forces were measured with and without lubrication by a saliva substitute. The measured values were analyzed according to the type of tooth (incisors, canines, premolars, and molars). Additionally, a comparison between lubricated and unlubricated telescopic crowns was done. As maximum retention force value 29.98 N was recorded with a telescopic crown on a molar, while the minimum of 0.08 N was found with a specimen on a canine. The median value of retention force of all telescopic crowns reached 1.93 N with an interquartile distance of 4.35 N. No statistically significant difference between lubricated and unlubricated specimens was found. The results indicate that retention force values of telescopic crowns, measured in clinical practice, are often much lower than those cited in the literature. The measurements also show a wide range. Whether this proves to be a problem for the patient's quality of life or not can however only be established by a comparison of the presented results with a follow-up study involving measurement of intraoral retention and determination by e.g. oral health impact profile.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY DESIGN.: Cadaver study. OBJECTIVE.: To determine bone strength in vertebrae by measuring peak breakaway torque or indentation force using custom-made pedicle probes. SUMMARY OF BACKGROUND DATA.: Screw performance in dorsal spinal instrumentation is dependent on bone quality of the vertebral body. To date no intraoperative measuring device to validate bone strength is available. Destructive testing may predict bone strength in transpedicular instrumentations in osteoporotic vertebrae. Insertional torque measurements showed varying results. METHODS.: Ten human cadaveric vertebrae were evaluated for bone mineral density (BMD) measurements by quantitative computed tomography. Peak torque and indentation force of custom-made probes as a measure for mechanical bone strength were assessed via a transpedicular approach. The results were correlated to regional BMD and to biomechanical load testing after pedicle screw implementation. RESULTS.: Both methods generated a positive correlation to failure load of the respective vertebrae. The correlation of peak breakaway torque to failure load was r = 0.959 (P = 0.003), therewith distinctly higher than the correlation of indentation force to failure load, which was r = 0.690 (P = 0.040). In predicting regional BMD, measurement of peak torque also performed better than that of indentation force (r = 0.897 [P = 0.002] vs. r = 0.777 [P = 0.017]). CONCLUSION.: Transpedicular measurement of peak breakaway torque is technically feasible and predicts reliable local bone strength and implant failure for dorsal spinal instrumentations in this experimental setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The goal when resuscitating trauma patients is to achieve adequate tissue perfusion. One parameter of tissue perfusion is tissue oxygen saturation (StO2), as measured by near infrared spectroscopy. Using a commercially available device, we investigated whether clinically relevant blood loss of 500 ml in healthy volunteers can be detected by changes in StO2 after a standardized ischemic event. Methods We performed occlusion of the brachial artery for 3 minutes in 20 healthy female blood donors before and after blood donation. StO2 and total oxygenated tissue hemoglobin (O2Hb) were measured continuously at the thenar eminence. 10 healthy volunteers were assessed in the same way, to examine whether repeated vascular occlusion without blood donation exhibits time dependent effects. Results Blood donation caused a substantial decrease in systolic blood pressure, but did not affect resting StO2 and O2Hb values. No changes were measured in the blood donor group in the reaction to the vascular occlusion test, but in the control group there was an increase in the O2Hb rate of recovery during the reperfusion phase. Conclusion StO2 measured at the thenar eminence seems to be insensitive to blood loss of 500 ml in this setting. Probably blood loss greater than this might lead to detectable changes guiding the treating physician. The exact cut off for detectable changes and the time effect on repeated vascular occlusion tests should be explored further. Until now no such data exist.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To determine the practicability and accuracy of central corneal thickness (CCT) measurements in living chicks utilizing a noncontact, high-speed optical low-coherence reflectometer (OLCR) mounted on a slit lamp. ANIMALS STUDIED Twelve male chicks (Gallus gallus domesticus). Procedures  Measurements of CCT were obtained in triplicate in 24 eyes of twelve 1-day-old anaesthetized chicks using OLCR. Every single measurement taken by OLCR consisted of the average result of 20 scans obtained within seconds. Additionally, corneal thickness was determined histologically after immersion fixation in Karnovsky's solution alone (20 eyes) or with a previous injection of the fixative into the anterior chamber before enucleation (4 eyes). RESULTS Central corneal thickness measurements using OLCR in 1-day-old living chicks provide a rapid and feasible examination technique. Mean CCT measured with OLCR (189.7 ± 3.34 μm) was significantly lower than histological measurements (242.1 ± 47.27 μm) in eyes with fixation in Karnovsky's solution (P = 0.0005). In eyes with additional injection of Karnovsky's fixative into the anterior chamber, mean histologically determined CCT was 195.2 ± 8.25 μm vs. 191.9 ± 8.90 μm with OLCR. A trend for a lower variance was found compared to the eyes that had only been immersion fixed. CONCLUSION Optical low-coherence reflectometry is an accurate examination technique to measure in vivo CCT in the eye of newborn chicks. The knowledge of the thickness of the chick cornea and the ability to obtain noninvasive, noncontact measurements of CCT in the living animal may be of interest for research and development of eye diseases in chick models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Information on the significance of dental care in older adults is limited. We hypothesized that regular dental visits has an effect on the number of remaining teeth and periodontal conditions in older subjects. MATERIALS AND METHODS: 1020 randomly selected individuals age 60 - 96 from the Swedish National Study on Aging and Care Blekinge received a comprehensive oral health examination. RESULTS: Dentate women and men had, on average 18.4 teeth (SD +7.6,) and 18.9 teeth (SD + 7.5) respectively (NS). In the youngest group (60 and 66 years old) with less than one dental visit per year, 37% had >20 teeth, compared with 73% among those with at least annual visits. Among the old-old, comparable figures were 1.8 % and 37% respectively. Across age groups, bleeding on probing was 23 %.When adjusting for age, and number of teeth GLM univariate analysis failed to demonstrate an effect of dental visit frequency on alveolar bone loss (p = 0.18), the number of periapical lesions (p = 0.65), or the number of endodontically treated teeth ( p = 0.41). Frequent dental visitors had more teeth than infrequent visitors (p = 0.001). CONCLUSIONS: Tooth loss and alveolar bone loss severity increase with age. Individuals with regular dental visits retained more teeth but the frequency of dental visits had no impact on plaque deposits, gingival inflammation, or alveolar bone levels.