928 resultados para femoral artery
Resumo:
AIMS To estimate physical activity trajectories for people who quit smoking, and compare them to what would have been expected had smoking continued. DESIGN, SETTING AND PARTICIPANTS A total of 5115 participants in the Coronary Artery Risk Development in Young Adults Study (CARDIA) study, a population-based study of African American and European American people recruited at age 18-30 years in 1985/6 and followed over 25 years. MEASUREMENTS Physical activity was self-reported during clinical examinations at baseline (1985/6) and at years 2, 5, 7, 10, 15, 20 and 25 (2010/11); smoking status was reported each year (at examinations or by telephone, and imputed where missing). We used mixed linear models to estimate trajectories of physical activity under varying smoking conditions, with adjustment for participant characteristics and secular trends. FINDINGS We found significant interactions by race/sex (P = 0.02 for the interaction with cumulative years of smoking), hence we investigated the subgroups separately. Increasing years of smoking were associated with a decline in physical activity in black and white women and black men [e.g. coefficient for 10 years of smoking: -0.14; 95% confidence interval (CI) = -0.20 to -0.07, P < 0.001 for white women]. An increase in physical activity was associated with years since smoking cessation in white men (coefficient 0.06; 95% CI = 0 to 0.13, P = 0.05). The physical activity trajectory for people who quit diverged progressively towards higher physical activity from the expected trajectory had smoking continued. For example, physical activity was 34% higher (95% CI = 18 to 52%; P < 0.001) for white women 10 years after stopping compared with continuing smoking for those 10 years (P = 0.21 for race/sex differences). CONCLUSIONS Smokers who quit have progressively higher levels of physical activity in the years after quitting compared with continuing smokers.
Resumo:
Aims To explore the impact of the functional severity of coronary artery stenosis on changes in myocardial oxygenation during pharmacological vasodilation, using oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR) imaging and invasive fractional flow reserve (FFR). An FFR is considered a standard of reference for assessing haemodynamic relevance of coronary artery stenosis; yet, the relationship of FFR to changes in myocardial oxygenation during vasodilator stress and thus to an objective marker for ischaemia on the tissue level is not well understood. Methods and results We prospectively recruited 64 patients with suspected/known coronary artery disease undergoing invasive angiography. The FFR was performed in intermediate coronary artery stenosis. OS-CMR images were acquired using a T2*-sensitive sequence before and after adenosine-induced vasodilation, with myocardial segments matched to angiography. Very strict image quality criteria were defined to ensure the validity of results. The FFR was performed in 37 patients. Because of the strict image quality criteria, 41% of segments had to be excluded, leaving 29/64 patients for the blinded OS-CMR analysis. Coronary territories with an associated FFR of <0.80 showed a lack of increase in myocardial oxygenation [mean signal intensity (ΔSI) −0.49%; 95% confidence interval (CI) −3.78 to 2.78 vs. +7.30%; 95% CI 4.08 to 10.64; P < 0.001]. An FFR of <0.54 best predicted a complete lack of a vasodilator-induced oxygenation increase (sensitivity 71% and specificity 75%). An OS-CMR ΔSI <4.78% identified an FFR of <0.8 with a sensitivity of 86% and specificity of 92%. Conclusion An FFR of <0.80 is associated with a lack of an adenosine-inducible increase in oxygenation of the dependent coronary territory, while a complete lack of such an increase was best predicted by an FFR of <0.54. Further studies are warranted to identify clinically meaningful cut-off values for FFR measurements and to assess the utility of OS-CMR as an alternative clinical tool for assessing the functional relevance of coronary artery stenosis.
Resumo:
BACKGROUND AND PURPOSE To determine the frequency of new ischaemic or hemorrhagic brain lesions on early follow-up magnetic resonance imaging (MRI) in patients with cervical artery dissection (CAD) and to investigate the relationship with antithrombotic treatment. METHODS This prospective observational study included consecutive CAD patients with ischaemic or non-ischaemic symptoms within the preceding 4 weeks. All patients had baseline brain MRI scans at the time of CAD diagnosis and follow-up MRI scans within 30 days thereafter. Ischaemic lesions were detected by diffusion-weighted imaging (DWI), intracerebral bleeds (ICBs) by paramagnetic-susceptible sequences. Outcome measures were any new DWI lesions or ICBs on follow-up MRI scans. Kaplan-Meier statistics and calculated odds ratios with 95% confidence intervals were used for lesion occurrence, baseline characteristics and type of antithrombotic treatment (antiplatelet versus anticoagulant). RESULTS Sixty-eight of 74 (92%) CAD patients were eligible for analysis. Median (interquartile range) time interval between baseline and follow-up MRI scans was 5 (3-10) days. New DWI lesions occurred in 17 (25%) patients with a cumulative 30-day incidence of 41.3% (standard error 8.6%). Occurrence of new DWI lesions was associated with stroke or transient ischaemic attack at presentation [7.86 (2.01-30.93)], occlusion of the dissected vessel [4.09 (1.24-13.55)] and presence of DWI lesions on baseline MRI [6.67 (1.70-26.13)]. The type of antithrombotic treatment had no impact either on occurrence of new DWI lesions [1.00 (0.32-3.15)] or on functional 6-month outcome [1.27 (0.41-3.94)]. No new ICBs were observed. CONCLUSION New ischaemic brain lesions occurred in a quarter of CAD patients, independently of the type of antithrombotic treatment. MRI findings could potentially serve as surrogate outcomes in pilot treatment trials.
Resumo:
PURPOSE The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. METHODS The institutional ethics committee approved this prospective study. A total of 41 patients suspected of having internal carotid artery (ICA) stenosis underwent both MDCTA and MRA. CE-MRA and TOF-MRA were performed using a 3.0-T imager with a dedicated eight-element cervical coil. ICA stenoses were measured according to the North American Symptomatic Carotid Endarterectomy Trial criteria and categorized as 0-25 % (minimal), 25-50 % (mild), 50-69 % (moderate), 70-99 % (high grade), and 100 % (occlusion). Sensitivity and specificity for the detection of high-grade ICA stenoses (70-99 %) and ICA occlusions were determined. In addition, intermodality agreement was assessed with κ-statistics for detection of high-grade ICA stenoses (70-99 %) and ICA occlusions. RESULTS A total of 80 carotid arteries of 41 patients were reviewed. Two previously stented ICAs were excluded from analysis. On MDCTA, 7 ICAs were occluded, 12 ICAs presented with and 63 without a high-grade ICA stenosis (70-99 %). For detecting 70-99 % stenosis, both 3D TOF-MRA and CE-MRA were 91.7 % sensitive and 98.5 % specific, respectively. Both MRA techniques were highly sensitive (100 %), and specific (CE-MRA, 100 %; TOF-MRA, 98.7 %) for the detection of ICA occlusion. However, TOF-MRA misclassified one high-grade stenosis as occlusion. Intermodality agreement for detection of 70-99 % ICA stenoses was excellent between TOF-MRA and CE-MRA [κ = 0.902, 95 % confidence interval (CI) = 0.769-1.000], TOF-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000), and CE-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000). CONCLUSION Both 3D TOF-MRA and CE-MRA at 3 T are reliable tools for detecting high-grade proximal ICA stenoses (70-99 %). 3D TOF-MRA might misclassify pseudo-occlusions as complete occlusions. If there are no contraindications for CE-MRA, CE-MRA is recommended as primary MR imaging modality.
Resumo:
PRINCIPLES Prediction of arrhythmic events (AEs) has gained importance with the availability of implantable cardioverter-defibrillators (ICDs), but is still imprecise. This study evaluated the innovative Wedensky modulation index (WMI) as predictor of AEs. METHODS In this prospective cohort, 179 patients with coronary artery disease (CAD) referred for AE risk assessment underwent baseline evaluation including measurement of R-/T-wave WMI (WMI(RT)) and left ventricular ejection fraction (LVEF). Two endpoints were assessed 3 years after the baseline evaluation: sudden cardiac death or appropriate ICD event (EP1) and any cardiac death or appropriate ICD event (EP2). Associations between baseline predictors (WMI(RT) and LVEF) and endpoints were evaluated in regression models. RESULTS Only three patients were lost to follow-up. EP1 and EP2 occurred in 24 and 27 patients, respectively. WMI(RT) (odds ratio [OR] per 1 point increase for EP1 20.1, 95% confidence interval [CI] 1.8-221.4, p = 0.014, and for EP2 73.3, 95% CI 6.6-817.7, p <0.001) and LVEF (OR per 1% increase for EP1 0.94, 95% CI 0.90-0.99, p = 0.013, and for EP2 0.93, 95% CI 0.89-0.97, p = 0.002) were significantly associated with both endpoints. In bivariable regression controlled for LVEF, WMI(RT) was independently associated with EP1 (p = 0.047) and EP2 (p = 0.007). The combination of WMI(RT) ≥0.60 and LVEF ≤30% resulted in a positive predictive value of 36% for EP1 and 50% for EP2. CONCLUSIONS WMI(RT) is a significant predictor of AEs independent of LVEF and has potential to improve AE risk prediction in CAD patients. However, WMI(RT) should be evaluated in larger and independent samples before recommendations for clinical routine can be made.
Resumo:
End caps are intended to prevent nail migration (push-out) in elastic stable intramedullary nailing. The aim of this study was to investigate the force at failure with and without end caps, and whether different insertion angles of nails and end caps would alter that force at failure. Simulated oblique fractures of the diaphysis were created in 15 artificial paediatric femurs. Titanium Elastic Nails with end caps were inserted at angles of 45°, 55° and 65° in five specimens for each angle to create three study groups. Biomechanical testing was performed with axial compression until failure. An identical fracture was created in four small adult cadaveric femurs harvested from two donors (both female, aged 81 and 85 years, height 149 cm and 156 cm, respectively). All femurs were tested without and subsequently with end caps inserted at 45°. In the artificial femurs, maximum force was not significantly different between the three groups (p = 0.613). Push-out force was significantly higher in the cadaveric specimens with the use of end caps by an up to sixfold load increase (830 N, standard deviation (SD) 280 vs 150 N, SD 120, respectively; p = 0.007). These results indicate that the nail and end cap insertion angle can be varied within 20° without altering construct stability and that the risk of elastic stable intramedullary nailing push-out can be effectively reduced by the use of end caps.
Resumo:
AIMS The purpose of the present study was to investigate the relationship between in-stent neoatherosclerosis (NA) and native atherosclerosis progression of untreated coronary segments. METHODS AND RESULTS In-stent NA was assessed by optical coherence tomography (OCT) among patients included in the SIRTAX-LATE OCT study 5 years after drug-eluting stent (DES) (sirolimus-eluting and paclitaxel-eluting stents) implantation. Neoatherosclerosis was defined as the presence of fibroatheroma or fibrocalcific plaque within the neointima of stented segments with a longitudinal extension >1.0 mm. Atherosclerosis progression in untreated native coronary segments was evaluated by serial quantitative coronary angiography (QCA). The change in minimal lumen diameter (MLD) was serially assessed within matched segments at baseline and 5-year angiographic follow-up. The key clinical endpoint was non-target lesion (non-TL) revascularization throughout 5 years. A total of 88 patients with 88 lesions were available for OCT analysis 5 years after DES implantation. In-stent NA was observed in 16% of lesions with the majority of plaques being fibroatheromas (11.4%) followed by fibrocalcific plaques (5.7%). A total of 704 non-TL segments were serially evaluated by QCA. Between baseline and 5-year follow-up, the reduction in MLD was significantly more pronounced in patients with NA (-0.25 mm, 95% CI -0.36 to -0.17 mm) when compared with patients without NA (-0.13 mm, 95% CI -0.17 to -0.10 mm, P = 0.002). Similarly, non-TL revascularization was more frequent in patients with NA (78.6%) when compared with patients without NA (44.6%, P = 0.028) throughout 5 years. CONCLUSIONS In-stent NA is more common among patients with angiographic and clinical evidence of native atherosclerosis progression suggesting similar pathophysiological mechanisms.SIRTAX trial is registered at http://www.clinicaltrials.gov/ct2/show/NCT00617084.
Resumo:
PURPOSE Fluorescence lifetime imaging ophthalmoscopy is a technique to measure decay times of endogenous retinal fluorophores. The purpose of this study was to investigate fluorescence lifetimes in eyes with central and branch retinal artery occlusion. METHODS Twenty-four patients with central or branch retinal artery occlusion were included in this study. The contralateral unaffected fellow eye was used as control. Measurements were performed using a fluorescence lifetime imaging ophthalmoscope based on a HRA Spectralis system. Fluorescence excitation wavelength was 473 nm, and mean lifetimes were measured in a short (498-560 nm) and in a long (560-720 nm) spectral channel. Fluorescence lifetimes in the area of retinal artery occlusion were measured and compared to corresponding areas in contralateral unaffected eyes. Additionally, findings were correlated to optical coherence tomography measurements. RESULTS Retinal lifetime images of 24 patients with retinal artery occlusion were analyzed. Mean retinal fluorescence lifetimes were prolonged by 50% in the short and 20% in the long spectral channel in ischemic retinal areas up to 3 days after retinal artery occlusion compared to the contralateral unaffected eyes. In the postacute disease stage there was no difference between the lifetimes of affected areas and unaffected fellow eyes. CONCLUSIONS Retinal artery occlusion leads to significantly longer fluorescence lifetimes of the retina in the acute phase and may serve as a useful indicator for acute ischemic retinal damage.
Resumo:
BACKGROUND AND PURPOSE Currently one of the most widely used models for the development of endovascular techniques and coiling devices for treatment of aneurysm is the elastase-induced aneurysm model in the rabbit carotid artery. Microsurgical techniques for creating an aneurysm with a venous pouch have also been established, although both techniques usually result in aneurysms less than 1 cm in diameter. We investigated whether an increase in blood flow toward the neck would produce larger aneurysms in a microsurgical venous pouch model. MATERIALS AND METHODS Microsurgical operations were performed on 11 New Zealand white rabbits. Both carotid arteries and the right jugular vein were dissected, and the right carotid artery was temporarily clipped followed by an arteriotomy. The left carotid artery was also clipped proximally, ligated distally, and sutured onto the proximal half of the arteriotomy in the right carotid artery. The venous graft was sutured onto the distal half of the arteriotomy. Digital subtraction angiography was also performed. RESULTS Angiography showed patent anastomosed vessels and aneurysms in the seven surviving rabbits. Mean aneurysm measurements among surviving rabbits with patent vessels were: 13.9 mm length, 9.3 mm width, and neck diameter 4.7 mm. The resulting mean aspect ratio was 3.35 and the mean bottleneck ratio was 3.05. CONCLUSION A large venous graft and increased blood flow toward the base of the aneurysm seem to be key factors in the creation of large venous pouch aneurysms. These large aneurysms allow testing of endovascular devices designed for large and giant aneurysms.
Resumo:
Compared with the coronary setting, knowledge about antithrombotic therapies after endovascular treatment (EVT) is inadequate in patients with peripheral artery disease (PAD). Based on a review of trials and guidelines, which is summarized in this article, there is scant evidence that antithrombotic drugs improve outcome after peripheral EVT. To address this knowledge gap, the randomized, open-label, multinational edoxaban in patients with Peripheral Artery Disease (ePAD) study (ClinicalTrials.gov identifier NCT01802775) was designed to explore the safety and efficacy of a combined regimen of antiplatelet therapy with clopidogrel and anticoagulation with edoxaban, a selective and direct factor Xa inhibitor, both combined with aspirin. As of July 2014, 203 patients (144 men; mean age 67 years) from 7 countries have been enrolled. These patients have been allocated to once-daily edoxaban [60 mg for 3 months (or 30 mg in the presence of factors associated with increased exposure)] or clopidogrel (75 mg/d for 3 months). All patients received aspirin (100 mg/d) for the 6-month duration of the study. The primary safety endpoint is major or clinically relevant nonmajor bleeding; the primary efficacy endpoint is restenosis or reocclusion at the treated segment(s) measured at 1, 3, and 6 months using duplex ultrasound scanning. All outcomes will be assessed and adjudicated centrally in a masked fashion. The ePAD study is the first of its kind to investigate a combined regimen of antiplatelet therapy and anticoagulation through factor Xa inhibition with edoxaban.
Resumo:
PURPOSE To investigate the 2-year technical and clinical results of primary nitinol stent placement in comparison with percutaneous transluminal angioplasty (PTA) in the treatment of de novo lesions of the popliteal artery. METHODS The ETAP study (Endovascular Treatment of Atherosclerotic Popliteal Artery Lesions: balloon angioplasty vs. primary stenting; www.ClinicalTrials.gov identifier NCT00712309) is a prospective, randomized trial that enrolled 246 patients (158 men; mean age 72 years) who were randomly assigned to receive a nitinol stent (n=119) or PTA (n=127) for lesions averaging 42.3 mm in length. The results of the primary study endpoint were published. Secondary outcome measures and endpoints included primary patency (freedom from duplex-detected target lesion restenosis), target lesion revascularization (TLR), secondary patency, changes in ankle-brachial index and Rutherford class, and event-free survival (freedom from target limb amputation, TLR, myocardial infarction, and death). RESULTS In total, 183 patients (89 stent and 94 PTA) were available for the 2-year analysis. The primary patency rate was significantly higher in the stent group (64.2%) than in the PTA group (31.3%, p=0.0001). TLR rates were 22.4% and 59.5%, respectively (p=0.0001). When provisional stent placement in the PTA arm was not considered as TLR and loss in patency, the differences prevailed between the study groups but were not significant (64.2% vs. 56.1% for primary patency, respectively; p=0.44). A significant improvement in ABI and Rutherford category was observed at 2 years in both groups. CONCLUSION In treatment of obstructive popliteal artery lesions, provisional stenting reveals equivalent patency in comparison to primary stenting. However, the 2-year results of this trial suggest the possibility of a shift toward higher patency rates in favor of primary stenting.
Resumo:
UNLABELLED This study aimed to assess the safety and effectiveness of renal denervation using the Symplicity system in real-world patients with uncontrolled hypertension (NCT01534299). The Global SYMPLICITY Registry is a prospective, open-label, multicenter registry. Office and 24-hour ambulatory blood pressures (BPs) were measured. Change from baseline to 6 months was analyzed for all patients and for subgroups based on baseline office systolic BP, diabetic status, and renal function; a cohort with severe hypertension (office systolic pressure, ≥160 mm Hg; 24-hour systolic pressure, ≥135 mm Hg; and ≥3 antihypertensive medication classes) was also included. The analysis included protocol-defined safety events. Six-month outcomes for 998 patients, including 323 in the severe hypertension cohort, are reported. Mean baseline office systolic BP was 163.5±24.0 mm Hg for all patients and 179.3±16.5 mm Hg for the severe cohort; the corresponding baseline 24-hour mean systolic BPs were 151.5±17.0 and 159.0±15.6 mm Hg. At 6 months, the changes in office and 24-hour systolic BPs were -11.6±25.3 and -6.6±18.0 mm Hg for all patients (P<0.001 for both) and -20.3±22.8 and -8.9±16.9 mm Hg for those with severe hypertension (P<0.001 for both). Renal denervation was associated with low rates of adverse events. After the procedure through 6 months, there was 1 new renal artery stenosis >70% and 5 cases of hospitalization for a hypertensive emergency. In clinical practice, renal denervation resulted in significant reductions in office and 24-hour BPs with a favorable safety profile. Greater BP-lowering effects occurred in patients with higher baseline pressures. CLINICAL TRIAL REGISTRATION URL: www.clinicaltrials.gov. Unique identifier: NCT01534299.
Resumo:
We assessed the prevalence of vertebral artery (VA) stenosis or occlusion and its influence on outcome in patients with acute basilar artery occlusion (BAO). We studied 141 patients with acute BAO enrolled in the Basilar Artery International Cooperation Study (BASICS) registry of whom baseline CT angiography (CTA) of the intracranial VAs was available. In 72 patients an additional CTA of the extracranial VAs was available. Adjusted risk ratios (aRRs) for death and poor outcome, defined as a modified Rankin Scale score ≥4, were calculated with Poisson regression in relation to VA occlusion, VA occlusion or stenosis ≥50 %, and bilateral VA occlusion. Sixty-six of 141 (47 %) patients had uni- or bilateral intracranial VA occlusion or stenosis ≥50 %. Of the 72 patients with intra- and extracranial CTA, 46 (64 %) had uni- or bilateral VA occlusion or stenosis ≥50 % and 9 (12 %) had bilateral VA occlusion. Overall, VA occlusion or stenosis ≥50 % was not associated with the risk of poor outcome. Patients with intra- and extracranial CTA and bilateral VA occlusion had a higher risk of poor outcome than patients without bilateral VA occlusion (aRR, 1.23; 95 % CI 1.02-1.50). The risk of death did not depend on the presence of unilateral or bilateral VA occlusion or stenosis ≥50 %. In conclusion, in patients with acute BAO, unilateral VA occlusion or stenosis ≥50 % is frequent, but not associated with an increased risk of poor outcome or death. Patients with BAO and bilateral VA occlusion have a slightly increased risk of poor outcome.