966 resultados para dynamic methods
Resumo:
INTRODUCTION: Methicillin-Resistant Staphylococcus aureus (MRSA) presenting reduced susceptibility to vancomycin has been associated to therapeutic failure. Some methods used by clinical laboratories may not be sufficiently accurate to detect this phenotype, compromising results and the outcome of the patient. OBJECTIVES: To evaluate the performance of methods in the detection of vancomycin MIC values among clinical isolates of MRSA. MATERIAL AND METHODS: The Vancomycin Minimal Inhibitory Concentration was determined for 75 MRSA isolates from inpatients of Mãe de Deus Hospital, Porto Alegre, Brazil. The broth microdilution (BM) was used as the gold-standard technique, as well as the following methods: E-test® strips (BioMérieux), M.I.C.E® strips (Oxoid), PROBAC® commercial panel and the automated system MicroScan® (Siemens). Besides, the agar screening test was carried out with 3 µg/mL of vancomycin. RESULTS: All isolates presented MIC ≤ 2 µg/mL for BM. E-test® had higher concordance (40%) in terms of global agreement with the gold standard, and there was not statistical difference among E-test® and broth microdilution results. PROBAC® panels presented MICs, in general, lower than the gold-standard panels (58.66% major errors), while M.I.C.E.® MICs were higher (67.99% minor errors). CONCLUSIONS: For the population of MRSA in question, E-test® presented the best performance, although with a heterogeneous accuracy, depending on MIC values.
Resumo:
Os sistemas de monitorização de estruturas fornecem diversas vantagens, não só no que diz respeito à durabilidade da obra, ao aumento da segurança e do conhecimento relativamente ao comportamento das estruturas ao longo do tempo, à otimização do aspeto estrutural, bem como aos aspetos económicos do processo de construção e manutenção. A monitorização deve realizar-se durante a fase de construção e/ou de exploração da obra para permitir o registo integral do seu comportamento no meio externo. Deve efetuar-se de forma contínua e automática, executando intervenções de rotina para que se possa detetar precocemente sinais de alterações, respetivamente à segurança, integridade e desempenho funcional. Assim se poderá manter a estrutura dentro de parâmetros aceitáveis de segurança. Assim, na presente dissertação será concebido um demonstrador experimental, para ser estudado em laboratório, no qual será implementado um sistema de monitorização contínuo e automático. Sobre este demonstrador será feita uma análise de diferentes grandezas em medição, tais como: deslocamentos, extensões, temperatura, rotações e acelerações. Com carácter inovador, pretende-se ainda incluir neste modelo em sintonia de medição de coordenadas GNSS com o qual se torna possível medir deslocamentos absolutos. Os resultados experimentais alcançados serão analisados e comparados com modelos numéricos. Conferem-se os resultados experimentais de natureza estática e dinâmica, com os resultados numéricos de dois modelos de elementos finitos: um de barras e outro de casca. Realizaram-se diferentes abordagens tendo em conta as características identificadas por via experimental e calculadas nos modelos numéricos para melhor ajuste e calibração dos modelos numéricos Por fim, recorre-se a algoritmos de processamento e tratamento do respetivo sinal com aplicação de filtros, que revelam melhorar com rigor o sinal, de forma a potenciar as técnicas de fusão multisensor. Pretende-se integrar o sinal GNSS com os demais sensores presentes no sistema de monitorização. As técnicas de fusão multisensor visam melhor o desempenho deste potencial sistema de medição, demonstrando as suas valências no domínio da monitorização estrutural.
Resumo:
Neste documento, são investigados vários métodos usados na inteligência artificial, com o objetivo de obter previsões precisas da evolução dos mercados financeiros. O uso de ferramentas lineares como os modelos AR, MA, ARMA e GARCH têm muitas limitações, pois torna-se muito difícil adaptá-los às não linearidades dos fenómenos que ocorrem nos mercados. Pelas razões anteriormente referidas, os algoritmos como as redes neuronais dinâmicas (TDNN, NARX e ESN), mostram uma maior capacidade de adaptação a estas não linearidades, pois não fazem qualquer pressuposto sobre as distribuições de probabilidade que caracterizam estes mercados. O facto destas redes neuronais serem dinâmicas, faz com que estas exibam um desempenho superior em relação às redes neuronais estáticas, ou outros algoritmos que não possuem qualquer tipo de memória. Apesar das vantagens reveladas pelas redes neuronais, estas são um sistema do tipo black box, o que torna muito difícil extrair informação dos pesos da rede. Isto significa que estes algoritmos devem ser usados com precaução, pois podem tornar-se instáveis.
Resumo:
SUMMARY Infection by Candidaspp. is associated with high mortality rates, especially when treatment is not appropriate and/or not immediate. Therefore, it is necessary to correctly identify the genus and species of Candida. The aim of this study was to compare the identification of 89 samples of Candida spp. by the manual methods germ tube test, auxanogram and chromogenic medium in relation to the ID 32C automated method. The concordances between the methods in ascending order, measured by the Kappa index were: ID 32C with CHROMagar Candida(κ = 0.38), ID 32C with auxanogram (κ = 0.59) and ID 32C with germ tube (κ = 0.9). One of the species identified in this study was C. tropicalis,which demonstrated a sensitivity of 46.2%, a specificity of 95.2%, PPV of 80%, NPV of 81.1%, and an accuracy of 80.9% in tests performed with CHROMagar Candida;and a sensitivity of 76.9%, a specificity of 96.8%, PPV of 90.9%, NPV of 91%, and an accuracy of 91% in the auxanogram tests. Therefore, it is necessary to know the advantages and limitations of methods to choose the best combination between them for a fast and correct identification of Candidaspecies.
Resumo:
Clinically childhood occipital lobe epilepsy (OLE) manifests itself with distinct syndromes. The traditional EEG recordings have not been able to overcome the difficulty in correlating the ictal clinical symptoms to the onset in particular areas of the occipital lobes. To understand these syndromes it is important to map with more precision the epileptogenic cortical regions in OLE. Experimentally, we studied three idiopathic childhood OLE patients with EEG source analysis and with the simultaneous acquisition of EEG and fMRI, to map the BOLD effect associated with EEG spikes. The spatial overlap between the EEG and BOLD results was not very good, but the fMRI suggested localizations more consistent with the ictal clinical manifestations of each type of epileptic syndrome. Since our first results show that by associating the BOLD effect with interictal spikes the epileptogenic areas are mapped to localizations different from those calculated from EEG sources and that by using different EEG/fMRI processing methods our results differ to some extent, it is very important to compare the different methods of processing the localization of activation and develop a good methodology for obtaining co-registration maps of high resolution EEG with BOLD localizations.
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia Electrotécnica e de Computadores
Resumo:
Trichomonas vaginalis is the etiologic agent of trichomoniasis, the most common non-viral sexually transmitted disease (STD) in the world. The diagnosis is based on wet mount preparation and direct microscopy on fixed and stained clinical specimens. The aim of this study was to compare the performance of different fixing and staining techniques used in the detection of T. vaginalis in urine. The smears were fixed and submitted to different methods of permanent staining and then, the morphological aspects of the parasites were analyzed and compared. The Papanicolaou staining with ethanol as the fixative solution showed to be the best method of permanent staining. Our data suggest that staining techniques in association with wet mount examination of fresh specimens contribute to increase the sensitivity in the diagnosis of trichomoniasis.
Resumo:
Bone histomorphometry is defined as a quantitative evaluation of bone micro architecture, remodelling and metabolism. Bone metabolic assessment is based on a dynamic process, which provides data on bone matrix formation rate by incorporating a tetracycline compound. In the static evaluation, samples are stained and a semi-automatic technique is applied in order to obtain bone microarchitectural parameters such as trabecular area, perimeter and width. These parameters are in 2D, but they can be extrapolated into 3D, applying a stereological formula. Histomorphometry can be applied to different areas; however, in recent decades it has been a relevant tool in monitoring the effect of drug administration in bone. The main challenge for the future will be the development of noninvasive methods that can give similar information. In the herein review paper we will discuss the general principles and main applications of bone histomorphometry.
Resumo:
RESUMO: Objectivo: O presente estudo tem como objectivo caracterizar os níveis de actividade física das pessoas com mais de 75 anos e analisar a sua relação com as diferentes componentes da aptidão física. Enquadramento: A actividade física é indispensável para todos mas, os idosos é quem mais beneficia (Fischer, 2005). Actua na prevenção e na reabilitação, fortalecendo a aptidão física, e a autonomia do idoso, permitindo manter, por mais tempo, a capacidade de execução das actividades de vida diárias (Shephard, 2003). A prática de actividade física contribui por exemplo, para a prevenção de quedas, reforçando a aptidão física e o equilíbrio postural. Por outro lado, o baixo nível de aptidão física repercute-se no aumento da actividade sedentária. Os homens têm uma adesão à actividade física de 45% e as mulheres de 28% (Melo et. al., 2007). Métodos: Este é um estudo observacional, correlacional e transversal. Foram avaliados 66 participantes (média de idade de 80,11 ± 3,83 anos), não institucionalizados. O processo de amostragem foi não probabilístico acidental por conveniência. Todos os idosos deram o seu consentimento informado. A actividade física foi avaliada através do questionário do Yale Physical Activity Survey, e foi desenvolvido um diário, para uma semana-tipo, para averiguar os hábitos de actividades diárias, nas últimas quatro semanas. A aptidão física foi avaliada pela bateria de testes de Rikli e Jones (1999),nomeadamente a força, a flexibilidade, a resistência aeróbia e a agilidade e equilíbrio. Os dados foram analisados através da estatística descritiva e para averiguar as possíveis associações entre a actividade física e a aptidão física, recorreu-se á estatística inferencial. Não tendo sido verificada a normalidade da amostra com o teste kolmogorov-smirnov, foram utilizados testes não paramétricos, nomeadamente o teste U Mann – Whitney e o coeficiente de correlação de Spearman (p≤0,05). Resultados: Constatou-se que os idosos em média praticavam 480, 23 minutos por semana de actividade moderada, cerca 11,04% do seu tempo, superior ao recomendado pela literatura (>150 minutos por semana). A actividade física moderada apresentou relações positivas com a aptidão física, na força dos membros inferiores, na resistência aeróbia e na agilidade e equilíbrio. Os homens têm maior agilidade e equilíbrio (p=0,002) e força dos membros inferiores (p=0,025) que as mulheres. Os homens passam mais tempo em actividade moderada do que as mulheres. Ainda superam no gasto energético em cada actividade que praticam durante a semana. As mulheres passam mais tempo em actividade sedentária e actividade ligeira. Conclusão: Quanto mais tempo de prática de actividade física moderada melhor a força dos membros inferiores, a resistência aeróbia, a agilidade e o equilíbrio dinâmico. Recomenda-se uma reflexão sobre a possível intervenção na estruturação das actividades diárias do idoso e uma intervenção mais direccionada às idosas, na força do membro inferior, na agilidade e na resistência aeróbia.----------------------- ABSTRACT:Purpose: The present study aims to characterize the physical activity levels of people over 75 years and analyze their relationship with the different components of physical fitness. Background: Physical activity is essential for all but the elderly who are more benefit (Fischer, 2005). It works on prevention and rehabilitation, strengthening physical fitness,and independence of older people, maintaining, for longer, the ability to implement the activities of daily living (Shephard, 2003). The physical activity contributes for example, for the prevention of falls by strengthening physical fitness and postural balance. Moreover, the low level of physical fitness level is reflected in the increase of sedentary activity. Men have an adherence to physical activity of 45% and women 28% (Melo et. al, 2007) Methods: This was an observational, cross-sectional and correlational. We evaluated 66 participants (mean age 80.11 ± 3.83 years), not institutionalized. The sampling procedure was non accidental probabilistic convenience. All seniors gave their informed consent. Physical activity was assessed by questionnaire at the Yale Physical Activity Survey was developed and a diary-type for a week, to ascertain the habits of daily activities in the last four weeks. Physical fitness was assessed by the battery of tests Rikli and Jones (1999), including strength, flexibility, endurance and agility and balance. Data were analyzed using descriptive statistics and to investigate possible associations between physical activity and physical fitness, we used will inferential statistics. Not having been verified the sample normality with Kolmogorov-Smirnov test, we used non-parametric tests, including the test U Mann - Whitney and Spearman correlation coefficient (p ≤ 0.05). Results: It was found that older people on average practiced 480, 23 minutes per week of moderate activity, about 11,04% of the time, higher than recommended in the literature (> 150 minutes per week). A moderate physical activity had positive correlations with physical fitness, lower limb strength, endurance and aerobic agility and balance. Men have greater agility and balance (p = 0.002) and lower-limb strength (p = 0.025) than women. Men spend more time in moderate activity than women. Still outweigh the energy expenditure for each activity they practice during the week. Women spend more time in sedentary activity and light activity. Conclusion: The more practice time in moderate physical activity best lower-limb strength,aerobic resistance, agility and dynamic balance. It is recommended that a reflection on the possible intervention in structuring the daily activities of the elderly and a more targeted to the woman elderly, especially lower limb strength, agility and endurance.
Resumo:
RESUMO: Introdução: A relação cinemática entre as articulações do CAO apresenta grande importância na função do MS, e é por isso cada vez mais investigada e descrita. O posicionamento da omoplata ganha um importante papel para compreender as DCAO. É indiscutível o importante papel da omoplata na dinâmica do MS, bem como o posicionamento escapular como parâmetro clínico de disfunção do CAO. Todos estes factores criam a necessidade de desenvolver instrumentos de avaliação da posição da articulação ET. A grande maioria dos testes de avaliação, restringem a sua avaliação às disfunções da articulação GU, não integrando uma avaliação mais dinâmica e interactiva que respeite os pressupostos teóricos inerentes ao REU. È importante também que os métodos de avaliação sejam de fácil aplicabilidade clínica e que avaliem fidedignamente e com validade os outcomes. Objectivos: Contribuir para o desenvolvimento de uma metodologia de avaliação da omoplata em diferentes amplitudes do MS, através do estudo da validade concorrente, da fidedignidade intra e inter-observador. Metodologia: A amostra foi constituída por 20 elementos seleccionados por conveniência, entre o corpo de discentes da ESS-IPS, sem história de disfunção do CAO. Foi realizada uma análise cinemática ao MS de cada sujeito, usando um aparelho de análise por varrimento electromagnético, o FOB. Em cada sujeito foram ainda medidas, as distâncias escapulares em estudo, usando a fita métrica. Cada método de medição foi constituído por dois momento (teste e reteste), em cada momento, as medidas eram recolhidas por dois investigadores distintos. Resultados e Discussão: Foram considerados como positivos os resultados que se apresentassem acima do limiar de 0,5, que classifica uma correlação como moderada a excelente. Os resultados da validade mostram que para o investigador 1 nas medidas M1e M2 apenas houve correlação com valores excelentes a moderados até aos 30º de elevação do MS. Já para M3 apenas aos 30º no plano da omoplata essa mesma correlação não tem valores próximos do cutpoint. Em M4 nenhum valor tem correlação significativa com os valores do FOB, chegando mesmo a haver correlação negativa para os 120º no plano da omoplata. Em M5 apenas os 0º mostram valores correlacionais excelentes a moderados. Para o investigador 2, em M1 e M2 á semelhança do investigador 1, só existem valores de correlação significativos até aos 30º de elevação do MS. Já para M3 todos os valores mostram excelente a moderada correlação á excepção dos 120º no plano frontal. Em M4 este investigador apresenta maus resultados. Já em M5 os valores de correlação são moderados aos 0º e aos 90º. No que diz respeitos aos resultados dos CCI intra-observador,podemos afirmar que foi em M5 que estes valores mais se aproximaram do cut point. M1 e M2 são as medidas onde se encontram resultados menos satisfatórios. É aos 60º que existem valores mais satisfatórios, seguidos pelos 0º e 30º, quando nos aproximamos de graus mais elevados, como 90º e 120º, estes valores tendem a baixar. Quanto á fidedignidade inter-observador para M1 apenas aos 90º e aos 120º houve valores de correlação abaixo do cutpoint. Em M2, só os 60º do plano sagital não teve valores acima do cutpoint, em M3 apenas os 30º plano sagital não obtiveram valores acima do cut-point, o mesmo acontece para M3 aos 30º plano da omoplata e em M5 aos 30º e 120º no plano frontal. Conclusão: Os resultados deste estudo indicam que a metodologia em causa apresenta elevado grau de fidedignidade inter-observador, já no que toca é fidedignidade intra-observador o grau de semelhança não é tão elevado. Também o erro associado á medida não ultrapassou 1,5cm, sendo considerado baixo. Na validade concorrente concluímos que é aos 0º que a metodologia se torna uma opção válida na aferição das distâncias medidas com uma boa a excelente concordância com o FOB. As medidas consideradas como opções válidas, nas diferentes amplitudes, podem funcionar como parâmetros clínicos de caracterização do posicionamento da omoplata, podendo vir a contribuir ainda para a caracterização da orientação da mesma.-------------------- ABSTRACT:Introduction: The kinematic relationship between the joints of the CAO has great importance in the function of MS, which is why more and more investigated and described. The positioning of the blade gets an important role in understanding the DCAO. There is no doubt the important role of the scapula in the dynamics of MS as well as the positioning of scapular dysfunction as a clinical parameter of the CAO. All these factors create the need to develop tools for evaluating the place of articulation ET. Most assessment tests, restrict its assessment to GU joint disorders, not incorporating a more dynamic and interactive way that respects the theoretical assumptions inherent in the REU. It is also important that the methods are easy to apply clinical and reliably to assess the validity and outcomes. Objectives: To contribute to the development of a methodology for evaluating the scapula in different ranges of MS, through the study of concurrent validity, reliability of intra-and inter-observer. Methodology: The sample consisted of 20 selected elements for convenience, between the body of students of IPS-ESS with no history of dysfunction of the CAO. We performed a kinematic analysis of each subject to MS, using a scanning device for electromagnetic analysis, the FOB. In each subject were also measured, the scapular distances under study, using tape measure. Each method of measuring the time consisted of two (test and retest), in each moment, the measures were collected by two different investigators. Results and Discussion: We considered as positive results that were above the threshold of 0.5, which ranks as a moderate to excellent correlation. The results show that the validity for the researcher in an action M1e M2 was only correlated with moderate to excellent values up to 30º of elevation of the MS. As for M3 only to 30º in the plane of the scapula has the same correlation values near the cutpoint. M4 has no value in correlation with the values of the FOB, and even negative correlation to 120 ° in the plane of the scapula. In M5 show only the values 0 ° correlational excellent to moderate. For investigator 2 in M1 and M2 will be like an investigator, there are only significant correlation values up to 30º of elevation of the MS. As for M3 all the values show excellent correlation to moderate with the exception of 120 ° in the frontal plane. In this researcher M4 has bad results. M5 already in the correlation values are moderate to 0º and 90 º. Regarding the results of ICC intra-observer, we can say that M5 was that these values come closest to the cut point. M1 and M2 are measures which are less than satisfactory results. At 60 ° there are more satisfactory values, followed by 0º and 30º, when we approached the highest levels, such as 90 ° and 120 °, these values tend to decrease. The inter-observer reliability for M1 only to 90 º and 120 ºcorrelation values were below the cutpoint. In M2, only 60 of the sagital plane did not have values above the cutpoint in M3 only 30º sagital plane did not obtain values above the cut-point, the same goes for M3 at 30 ° plane of the scapula and M5 at 30 º and 120 º in frontal plane. Conclusion: The results of this study indicate that the methodology in question has a high degree of inter-observer reliability, as far as intra-observer reliability is the degree of similarity is not as high. Also the error of measure did not exceed 1.5 cm, and is considered low. In concurrent validity conclude that it is at 0 ° the methodology becomes a valid option for the measurement of distances measured with a good to excellent agreement with the FOB. The measures considered as valid options in different amplitudes, can function as clinical parameters to characterize the positioning of the shoulder blade and could further contribute to the characterization of the orientation of the same.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
RESUMO - Introdução: A necessidade de gestão da ameaça de uma pandemia obriga à gestão da incerteza absoluta. O desconhecimento científico quanto a uma série de factores tais como, as características dos vírus causadores de infecções, a efectividade das medidas de prevenção e de tratamento, contribuiu para a dificuldade de actuação a vários níveis. Face à evolução da situação epidemiológica mundial no campo da gripe, Portugal reviu e adaptou o seu plano de contingência para a gripe tendo sido homologado, em Janeiro de 2006, um novo plano – Plano de Contingência Nacional do Sector da Saúde para a Pandemia. Objectivos: O presente estudo apresenta como principais objectivos (1) a avaliação das estratégias de intervenção e respectiva implementação das medidas de saúde pública não farmacológicas, durante a pandemia da gripe de 2009; (2) a identificação dos pontos críticos na gestão das medidas de saúde pública não farmacológicas, para preparação e resposta a futuras pandemias da gripe e, por último, (3) a definição de um modelo de acompanhamento, de monitorização e de avaliação das medidas de saúde pública não farmacológicas, que permita identificar os pontos importantes a ter em conta na implementação de boas práticas de saúde pública, nos diferentes níveis de prestação de cuidados de saúde, tendo como limitação o estado da arte dos sistemas de informação e avaliação, nacionais e internacionais, existentes. Material e Métodos: Para a avaliação das estratégias de intervenção e respectiva implementação das medidas de saúde pública não farmacológicas bem como, para a identificação dos pontos críticos na gestão das respectivas medidas foram consideradas duas perspectivas: a avaliação dos resultados através do Relatório da Pandemia da Gripe e a avaliação dos resultados através das avaliações da OMS e da Euro OMS. É apresentado um modelo de acompanhamento, de monitorização e de avaliação das medidas de saúde pública não farmacológicas, a implementar na classe médica que esteve na “linha da frente”, durante a pandemia H1N1 2009 em Portugal, nos cuidados primários, hospitalares e intensivos. Resultados: Deverá existir uma representação dos profissionais de saúde para suporte das decisões de forma a assegurar uma representação alargada não só na preparação mas também, na implementação e na aplicação do Plano de Contingência. O processo de planemanto deverá ter acesso público com possibilidade de participação activa do cidadão na sua implementação. O Plano deve ter a capacidade para se adaptar à situação epidemiológica e, no terreno os exercícios de simulações durante o processo de planeamento são importantes. As orientações técnicas devem ser dinâmicas, práticas, específicas e úteis e, dever-se investir numa cultura de confiança (“right people communicating to right people”). As alterações ao plano devem partir da coordenação, comando e controlo que, nos vários níveis de decisão, devem definir claramente quem toma as decisões. Conclusões: As estratégias para as intervenções ao nível da saúde pública, continuam, no mundo hodierno a desempenhar um papel fundamental e crucial na contenção das pandemias. O modelo apresentado neste estudo procura uma abordagem objectiva para destacar não só, os elementos essenciais de actividades bem-sucedidas, mas também as áreas em que a experiência pandémica sugere que o futuro planeamento deve dar maior ênfase.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Engenharia do Ambiente, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
Multiparametric Magnetic Resonance Imaging has been increasingly used for detection, localization and staging of prostate cancer over the last years. It combines high-resolution T2 Weighted-Imaging and at least two functional techniques, which include Dynamic Contrast–Enhanced Magnetic Resonance Imaging, Diffusion-Weighted Imaging, and Magnetic Resonance Imaging Spectroscopy. Although the combined use of a pelvic phased-array and an Endorectal Coil is considered the state-of-the-art for Magnetic Resonance Imaging evaluation of prostate cancer, Endorectal Coil is only absolute mandatory for Magnetic Resonance Imaging Spectroscopy at 1.5 T. Sensitivity and specificity levels in cancer detection and localization have been improving with functional technique implementation, compared to T2 Weighted-Imaging alone. It has been particularly useful to evaluate patients with abnormal PSA and negative biopsy. Moreover, the information added by the functional techniques may correlate to cancer aggressiveness and therefore be useful to select patients for focal radiotherapy, prostate sparing surgery, focal ablative therapy and active surveillance. However, more studies are needed to compare the functional techniques and understand the advantages and disadvantages of each one. This article reviews the basic principles of prostatic mp-Magnetic Resonance Imaging, emphasizing its role on detection, staging and active surveillance of prostate cancer.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics