979 resultados para approximate calculation of sums
Resumo:
Effective collision strengths for the 10 astrophysically important fine-structure forbidden transitions among the 4So, 2Do and 2Po levels in the 3s23p3 configuration of Cl III are presented. The calculation employs the multichannel R-matrix method to compute the electron-impact excitation collision strengths in a close-coupling expansion, which incorporates the lowest 23 LS target eigenstates of Cl III. These states are formed from the 3s23p3, 3s3p4, 3s23p23d and 3s23p24s configurations. The Maxwellian-averaged effective collision strengths are presented graphically for all 10 fine-structure transitions over a wide range of electron temperatures appropriate for astrophysical applications [log T(K) = 3.3 - log T(K) = 5.9]. Comparisons are made with the earlier seven-state close-coupling calculation of Butler & Zeippen, and in general excellent agreement is found in the low-temperature region where a comparison is possible [log T(K) = 3.3 - log T(K) = 4.7]. However, discrepancies of up to 30 per cent are found to occur for the forbidden transitions which involve the 4So ground state level, particularly for the lowest temperatures considered. At the higher temperatures, the present data are the only reliable results currently available.
Resumo:
Effective collision strengths for electron-impact excitation of the N-like ion NeIV are calculated in the close-coupling approximation using the multichannel R-matrix method. Specific attention is given to the 10 astrophysically important fine-structure forbidden transitions among the 4So, 2Do and 2Po levels in the 2s22p3 ground-state configuration. The expansion of the total wavefunction incorporates the lowest 11 LS eigenstates of NeIV, consisting of eight n = 2 terms with configurations 2s22p3, 2s2p4 and 2p5, together with three n = 3 states of configuration 2s22p23s. We present in graphical form the effective collision strengths obtained by thermally averaging the collision strengths over a Maxwellian distribution of velocities, for all 10 fine-structure transitions, over the range of electron temperatures log T(K) = 3.6 to log T(K) = 6.1 (the range appropriate for astrophysical applications). Comparisons are made with the earlier, less sophisticated close-coupling calculation of Giles, and excellent agreement is found in the limited temperature region where a comparison is possible [log T(K) = 3.7 to log 7(K) = 4.3]. At higher temperatures the present data are the only reliable results currently available.
Resumo:
Reinforced concrete (RC) jacketing is a common method for retrofitting existing columns with poor structural performance. It can be applied in two different ways: if the continuity of the jacket is ensured, the axial load of the column can be transferred to the jacket, which will be directly loaded; conversely, if no continuity is provided, the jacket will induce only confinement action. In both cases the strength and ductility evaluation is rather complex, due to the different physical phenomena included, such as confinement, core-jacket composite action, preload and buckling of longitudinal bars.
Although different theoretical studies have been carried out to calculate the confinement effects, a practical approach to evaluate the flexural capacity and ductility is still missing. The calculation of these quantities is often related to the use of commercial software, taking advantage of numerical methods such as fibre method or finite element method.
This paper presents a simplified approach to calculate the flexural strength and ductility of square RC jacketed sections subjected to axial load and bending moment. In particular the proposed approach is based on the calibration of the stress-block parameters including the confinement effect. Equilibrium equations are determined and buckling of longitudinal bars is modelled with a suitable stress-strain law. Moment-curvature curves are derived with simple calculations. Finally, comparisons are made with numerical analyses carried out with the code OpenSees and with experimental data available in the literature, showing good agreement.
Resumo:
BACKGROUND: The task of revising dietary folate recommendations for optimal health is complicated by a lack of data quantifying the biomarker response that reliably reflects a given folate intake.
OBJECTIVE: We conducted a dose-response meta-analysis in healthy adults to quantify the typical response of recognized folate biomarkers to a change in folic acid intake.
DESIGN: Electronic and bibliographic searches identified 19 randomized controlled trials that supplemented with folic acid and measured folate biomarkers before and after the intervention in apparently healthy adults aged ≥18 y. For each biomarker response, the regression coefficient (β) for individual studies and the overall pooled β were calculated by using random-effects meta-analysis.
RESULTS: Folate biomarkers (serum/plasma and red blood cell folate) increased in response to folic acid in a dose-response manner only up to an intake of 400 μg/d. Calculation of the overall pooled β for studies in the range of 50 to 400 μg/d indicated that a doubling of folic acid intake resulted in an increase in serum/plasma folate by 63% (71% for microbiological assay; 61% for nonmicrobiological assay) and red blood cell folate by 31% (irrespective of whether microbiological or other assay was used). Studies that used the microbiological assay indicated lower heterogeneity compared with studies using nonmicrobiological assays for determining serum/plasma (I(2) = 13.5% compared with I(2) = 77.2%) and red blood cell (I(2) = 45.9% compared with I(2) = 70.2%) folate.
CONCLUSIONS: Studies administering >400 μg folic acid/d show no dose-response relation and thus will not yield meaningful results for consideration when generating dietary folate recommendations. The calculated folate biomarker response to a given folic acid intake may be more robust with the use of a microbiological assay rather than alternative methods for blood folate measurement.
Resumo:
Laser transmission joining (LTJ) is growing in importance, and has the potential to become a niche technique for the fabrication of hybrid plastic-metal joints for medical device applications. The possibility of directly joining plastics to metals by LTJ has been demonstrated by a number of recent studies. However, a reliable and quantitative method for defining the contact area between the plastic and metal, facilitating calculation of the mechanical shear stress of the hybrid joints, is still lacking. A new method, based on image analysis using ImageJ, is proposed here to quantify the contact area at the joint interface. The effect of discolouration on the mechanical performance of the hybrid joints is also reported for the first time. Biocompatible polyethylene terephthalate (PET) and commercially pure titanium (Ti) were selected as materials for laser joining using a 200 W CW fibre laser system. The effect of laser power, scanning speed and stand-off distance between the nozzle tip and top surface of the plastic were studied and analysed by Taguchi L9 orthogonal array and ANOVA respectively. The surface morphology, structure and elemental composition on the PET and Ti surfaces after shearing/peeling apart were characterized by SEM, EDX, XRD and XPS.
Resumo:
Este trabalho apresenta um estudo sobre o dimensionamento de redes ópticas, com vistas a obter um modelo de dimensionamento para redes de transporte sobreviventes. No estudo utilizou-se uma abordagem estatística em detrimento à determinística. Inicialmente, apresentam-se as principais tecnologias e diferentes arquitecturas utilizadas nas redes ópticas de transporte. Bem como os principais esquemas de sobrevivência e modos de transporte. São identificadas variáveis necessárias e apresenta-se um modelo dimensionamento para redes de transporte, tendo-se dado ênfase às redes com topologia em malha e considerando os modos de transporte opaco, transparente e translúcido. É feita uma análise rigorosa das características das topologias de redes de transporte reais, e desenvolve-se um gerador de topologias de redes de transporte, para testar a validade dos modelos desenvolvidos. Também é implementado um algoritmo genético para a obtenção de uma topologia optimizada para um dado tráfego. São propostas expressões para o cálculo de variáveis não determinísticas, nomeadamente, para o número médio de saltos de um pedido, coeficiente de protecção e coeficiente de restauro. Para as duas últimas, também é analisado o impacto do modelo de tráfego. Verifica-se que os resultados obtidos pelas expressões propostas são similares às obtidas por cálculo numérico, e que o modelo de tráfego não influencia significativamente os valores obtidos para os coeficientes. Finalmente, é demonstrado que o modelo proposto é útil para o dimensionamento e cálculo dos custos de capital de redes com informação incompleta.
Resumo:
This paper presents a simple solution for the flexibility calculation of curved profiles having a rectangular thin-walled cross-section. Some assumptions related to geometric details about the shape of the deformed structure are included in the present analysis, aiming at an economic and accurate solution. Results concerning the distortion of the transverse section are compared with the corresponding data from the solution with a thin shell finite element analysis. A flexibility factor for the structure analysed here is presented as a graphical result.
Resumo:
Esta tese apresenta um estudo sobre otimização económica de parques eólicos, com o objetivo de obter um algoritmo para otimização económica de parques eólicos através do custo da energia produzida. No estudo utilizou-se uma abordagem multidisciplinar. Inicialmente, apresentam-se as principais tecnologias e diferentes arquiteturas utilizadas nos parques eólicos. Bem como esquemas de funcionamento e gestão dos parques. São identificadas variáveis necessárias e apresenta-se um modelo dimensionamento para cálculo dos custos da energia produzida, tendo-se dado ênfase às instalações onshore e ligados a rede elétrica de distribuição. É feita uma análise rigorosa das características das topologias dos aerogeradores disponíveis no mercado, e simula-se o funcionamento de um parque eólico para testar a validade dos modelos desenvolvidos. Também é implementado um algoritmo para a obtenção de uma resposta otimizada para o ciclo de vida económico do parque eólico em estudo. A abordagem proposta envolve algoritmos para otimização do custo de produção com multiplas funções objetivas com base na descrição matemática da produção de eletricidade. Foram desenvolvidos modelos de otimização linear, que estabelece a ligação entre o custo económico e a produção de eletricidade, tendo em conta ainda as emissões de CO2 em instrumentos de política energética para energia eólica. São propostas expressões para o cálculo do custo de energia com variáveis não convencionais, nomeadamente, para a produção variável do parque eólico, fator de funcionamento e coeficiente de eficiência geral do sistema. Para as duas últimas, também é analisado o impacto da distribuição do vento predominante no sistema de conversão de energia eólica. Verifica-se que os resultados obtidos pelos algoritmos propostos são similares às obtidas por demais métodos numéricos já publicados na comunidade científica, e que o algoritmo de otimização económica sofre influência significativa dos valores obtidos dos coeficientes em questão. Finalmente, é demonstrado que o algoritmo proposto (LCOEwso) é útil para o dimensionamento e cálculo dos custos de capital e O&M dos parques eólicos com informação incompleta ou em fase de projeto. Nesse sentido, o contributo desta tese vem ser desenvolver uma ferramenta de apoio à tomada de decisão de um gestor, investidor ou ainda agente público em fomentar a implantação de um parque eólico.
Resumo:
Viscoelastic treatments are one of the most efficient treatments, as far as passive damping is concerned, particularly in the case of thin and light structures. In this type of treatment, part of the strain energy generated in the viscoelastic material is dissipated to the surroundings, in the form of heat. A layer of viscoelastic material is applied to a structure in an unconstrained or constrained configuration, the latter proving to be the most efficient arrangement. This is due to the fact that the relative movement of both the host and constraining layers cause the viscoelastic material to be subjected to a relatively high strain energy. There are studies, however, that claim that the partial application of the viscoelastic material is just as efficient, in terms of economic costs or any other form of treatment application costs. The application of patches of material in specific and selected areas of the structure, thus minimising the extension of damping material, results in an equally efficient treatment. Since the damping mechanism of a viscoelastic material is based on the dissipation of part of the strain energy, the efficiency of the partial treatment can be correlated to the modal strain energy of the structure. Even though the results obtained with this approach in various studies are considered very satisfactory, an optimisation procedure is deemed necessary. In order to obtain optimum solutions, however, time consuming numerical simulations are required. The optimisation process to use the minimum amount of viscoelastic material is based on an evolutionary geometry re-design and calculation of the modal damping, making this procedure computationally costly. To avert this disadvantage, this study uses adaptive layerwise finite elements and applies Genetic Algorithms in the optimisation process.
Resumo:
Tese de dout., Ciências do Mar, da Terra e do Ambiente (Ciências do Mar-Oceanografia Física), Faculdade de Ciências e Tecnologia, Univ. do Algarve, 2011
Resumo:
Dissertação de Mestrado, Economia do Turismo e Desenvolvimento Regional, Faculdade de Economia, Universidade do Algarve, 2015
Resumo:
Dissertação de Mestrado, Mestrado em Qualidade em Análises, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2015
Resumo:
Tese de mestrado, Educação (Didáctica da Matemática), Universidade de Lisboa, Instituto de Educação, 2010
Resumo:
Air quality is an increasing concern of the European Union, local authorities, scientists and most of all inhabitants that become more aware of the quality of the surrounding environment. Bioaerosols may be consisted of various elements, and the most important are pollen grains, fungal spores, bacteria, viruses. More than 100 genera of fungal spores have been identified as potential allergens that cause immunological response in susceptible individuals. Alternaria and Cladosporium have been recognised as the most important fungal species responsible for respiratory tract diseases, such as asthma, eczema, rhinitis and chronic sinusitis. While a lot of attention has been given to these fungal species, a limited number of studies can be found on Didymella and Ganoderma, although their allergenic properties were proved clinically. Monitoring of allergenic fungal spore concentration in the air is therefore very important, and in particular at densely populated areas like Worcester, UK. In this thesis a five year spore data set was presented, which was collected using a 7-day volumetric spore trap, analysed with the aid of light microscopy, statistical tests and geographic information system techniques. Although Kruskal-Wallis test detected statistically significant differences between annual concentrations of all examined fungal spore types, specific patterns in their distribution were also found. Alternaria spores were present in the air between mid-May/mid-June until September-October with peak occurring in August. Cladosporium sporulated between mid-May and October, with maximum concentration recorded in July. Didymella spores were seen from June/July up to September, while peaks were found in August. Ganoderma produced spores for 6 months (May-October), and maximum concentration could be found in September. With respect to diurnal fluctuations, Alternaria peaked between 22:00h and 23:00h, Cladosporium 13:00-15:00h, Didymella 04:00-05:00h and 22:00h-23:00h and Ganoderma from 03:00h to 06:00h. Spatial analysis showed that sources of all fungal species were located in England, and there was no evidence for a long distance transport from the continent. The maximum concentration of spores was found several hours delayed in comparison to the approximate time of the spore release from the crops. This was in agreement with diurnal profiles of the spore concentration recorded in Worcester, UK. Spores of Alternaria, Didymella and Ganoderma revealed a regional origin, in contrast to Cladosporium, which sources were situated locally. Hence, the weather conditions registered locally did not exhibit strong statistically significant correlations with fungal spore concentrations. This has had also an impact on the performance of the forecasting models. The best model was obtained for Cladosporium with 66% of the accuracy.
Resumo:
Senior thesis written for Oceanography 445