870 resultados para Wrapper validation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The deltoid (anterior portion) and pectoralis major (clavicular portion) were evaluated in several execution ways of military press exercises with open and middle grips in order to know their behavior pattern. It was analyzed 24 male volunteers, using a 2-channel TECA TE4 electromyograph and Hewllet Packard surface electrodes. It was observed that the execution variation with open and middle grips does not present any significant difference as for the demanding level neither for the pectoralis major muscle nor the deltoid muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validation of a microbiological assay, applying agar diffusion method for determination of the active of cefuroxime in power for injection, is described. Using a strain of Micrococcus luteus ATCC 9341 as the test organism, cefuroxime was measured in concentrations ranging from 30.0 to 120.0 μg/mL. The method validation showed that it is linear (r = 0.9999), precise (relative standard deviation = 0.37%) and accurate (it measured the added quantities). Microbiological assay is satisfactory for quantitation of cefuroxime in powder for injection and the validity of the proposed bioassay, which is a simple and a useful alternative methodology for cefuroxime determination in routine quality control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ceftriaxone sodium is a cephalosporin with broad-spectrum antimicrobial activity and belongs to the third generation of cephalosporins. Regarding the quality control of medicines, a validated microbiological assay for the determination of ceftriaxone sodium in powder for injectable solution has not been reported yet. This paper reports the development and validation of a simple, accurate and reproducible agar diffusion method to quantify ceftriaxone sodium in powder for injectable solution. The assay is based on the inhibitory effect of ceftriaxone sodium on the strain of Bacillus subtilis ATCC 9371 IAL 1027 used as test microorganism. The results were treated statistically by analysis of variance and were found to be linear (r = 0.999) in the selected range of 15.0-60.0 μg/mL, precise with a relative standard deviation (RSD) of repeatability intraday = 1.40%, accurate (100.46%) and robust with a RSD lower than 1.28%. The results demonstrated the validity of the proposed bioassay, which allows reliable ceftriaxone sodium quantitation in pharmaceutical samples and therefore can be used as a useful alternative methodology for the routine quality control of this medicine. © 2012 by the authors; licensee MDPI, Basel, Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of tigecycline in lyophilized powder. The LC method was conducted on a Luna C18 column (250 × 4.6 mm i.d.), maintained at room temperature. The mobile phase consisted of buffer containing sodium phosphate monobasic (0.015M) and oxalic acid (0.015M) (pH 7.0)-acetonitrile (75:25, v/v), run at a flow rate of 1.0 mL/min and using ultraviolet detection at 280 nm. The chromatographic separation was obtained with a retention time of 8.6 min, and was linear in the range of 40-100 μg/mL (r2 = 0.9997). The specificity and stability-indicating capability of the method was proven through forced degradation studies, which also showed no interference of the excipients. The accuracy was 99.01% with a bias lower than 1.81%. The limits of detection and quantitation were 1.67 and 5.05 μg/mL, respectively. Moreover, method validation demonstrated satisfactory results for precision and robustness. The proposed method was applied for the analysis of the lyophilized powder formulation, contributing to improve the quality control and to assure the therapeutic efficacy. © The Author [2012]. Published by Oxford University Press. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Objective: Simple Measure of the Impact of Lupus Erythematosus in Youngsters (SMILEY) is a health-related quality of life (HRQOL) assessment tool for pediatric systemic lupus erythematosus (SLE), which has been translated into Portuguese for Brazil. We are reporting preliminary data on cross-cultural validation and reliability of SMILEY in Portuguese (Brazil). Methods: In this multi-center cross-sectional study, Brazilian children and adolescents 5-18 years of age with SLE and parents participated. Children and parents completed child and parent reports of Portuguese SMILEY and Portuguese Pediatric Quality of Life Inventory (PedsQLTM) Generic and Rheumatology modules. Parents also completed the Childhood Health Assessment Questionnaire (CHAQ). Physicians completed the SLE disease activity index (SLEDAI), Physician's Global Assessment of disease activity (PGA) and Systemic Lupus Erythematosus International Collaborating Clinics ACR Damage Index (SDI). Results: 99 subjects (84 girls) were enrolled; 93 children and 97 parents filled out the SMILEY scale. Subjects found SMILEY relevant and easy to understand and completed SMILEY in 5-15 minutes. Brazilian SMILEY was found to have good psychometric properties (validity and reliability), and the child-parent agreement was moderate. Conclusion: SMILEY may eventually be used routinely as a research/clinical tool in Brazil. It may be also adapted for other Portuguese-speaking nations offering critical information regarding the effect of SLE on HRQOL for children with SLE. © The Author(s), 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lubricating oils are crucial in the operation of automotive engines because they both reduce friction between moving parts and protect against corrosion. However, the performance of lubricant oil may be affected by contaminants, such as gasoline, diesel, ethanol, water and ethylene glycol. Although there are many standard methods and studies related to the quantification of contaminants in lubricant oil, such as gasoline and diesel oil, to the best of our knowledge, no methods have been reported for the quantification of ethanol in used Otto cycle engine lubrication oils. Therefore, this work aimed at the development and validation of a routine method based on partial least-squares multivariate analysis combined with attenuated total reflectance in the mid-infrared region to quantify ethanol content in used lubrication oil. The method was validated based on its figures of merit (using the net analyte signal) as follows: limit of detection (0.049%), limit of quantification (0.16%), accuracy (root mean square error of prediction=0.089% w/w), repeatability (0.05% w/w), fit (R 2 =0.9997), mean selectivity (0.047), sensitivity (0.011), inverse analytical sensitivity (0.016% w/w-1) and signal-to-noise ratio (max: 812.4 and min: 200.9). The results show that the proposed method can be routinely implemented for the quality control of lubricant oils. © 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mitochondrial DNA (mtDNA) analysis is usually a last resort in routine forensic DNA casework. However, it has become a powerful tool for the analysis of highly degraded samples or samples containing too little or no nuclear DNA, such as old bones and hair shafts. The gold standard methodology still constitutes the direct sequencing of polymerase chain reaction (PCR) products or cloned amplicons from the HVS-1 and HVS-2 (hypervariable segment) control region segments. Identifications using mtDNA are time consuming, expensive and can be very complex, depending on the amount and nature of the material being tested. The main goal of this work is to develop a less labour-intensive and less expensive screening method for mtDNA analysis, in order to aid in the exclusion of non-matching samples and as a presumptive test prior to final confirmatory DNA sequencing. We have selected 14 highly discriminatory single nucleotide polymorphisms (SNPs) based on simulations performed by Salas and Amigo (2010) [1] to be typed using SNaPShotTM (Applied Biosystems, Foster City, CA, USA). The assay was validated by typing more than 100 HVS-1/HVS-2 sequenced samples. No differences were observed between the SNP typing and DNA sequencing when results were compared, with the exception of allelic dropouts observed in a few haplotypes. Haplotype diversity simulations were performed using 172 mtDNA sequences representative of the Brazilian population and a score of 0.9794 was obtained when the 14 SNPs were used, showing that the theoretical prediction approach for the selection of highly discriminatory SNPs suggested by Salas and Amigo (2010) [1] was confirmed in the population studied. As the main goal of the work is to develop a screening assay to skip the sequencing of all samples in a particular case, a pair-wise comparison of the sequences was done using the selected SNPs. When both HVS-1/HVS-2 SNPs were used for simulations, at least two differences were observed in 93.2% of the comparisons performed. The assay was validated with casework samples. Results show that the method is straightforward and can be used for exclusionary purposes, saving time and laboratory resources. The assay confirms the theoretic prediction suggested by Salas and Amigo (2010) [1]. All forensic advantages, such as high sensitivity and power of discrimination, as also the disadvantages, such as the occurrence of allele dropouts, are discussed throughout the article. © 2013 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: A scale validated in one language is not automatically valid in another language or culture. The purpose of this study was to validate the English version of the UNESP-Botucatu multidimensional composite pain scale (MCPS) to assess postoperative pain in cats. The English version was developed using translation, back-translation, and review by individuals with expertise in feline pain management. In sequence, validity and reliability tests were performed.Results: Of the three domains identified by factor analysis, the internal consistency was excellent for 'pain expression' and 'psychomotor change' (0.86 and 0.87) but not for 'physiological variables' (0.28). Relevant changes in pain scores at clinically distinct time points (e.g., post-surgery, post-analgesic therapy), confirmed the construct validity and responsiveness (Wilcoxon test, p < 0.001). Favorable correlation with the IVAS scores (p < 0.001) and moderate to very good agreement between blinded observers and 'gold standard' evaluations, supported criterion validity. The cut-off point for rescue analgesia was > 7 (range 0-30 points) with 96.5% sensitivity and 99.5% specificity.Conclusions: The English version of the UNESP-Botucatu-MCPS is a valid, reliable and responsive instrument for assessing acute pain in cats undergoing ovariohysterectomy, when used by anesthesiologists or anesthesia technicians. The cut-off point for rescue analgesia provides an additional tool for guiding analgesic therapy. © 2013 Brondani et al.; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Apathy is a frequent neuropsychiatric condition in neurodegenerative disorders, depression, and often in mild cognitive impairment. The Apathy Inventory (AI) is a reliable instrument for improving the accuracy of the apathy diagnosis. The aim was to establish the validity of the Apathy Inventory for the Brazilian community. Methods We established the concurrent validity, internal consistency, inter-rater reliability, and the sensitivity and specificity of AI for the Brazilian community in a cohort of 175 individuals with Alzheimer's disease, Parkinson's disease, depression, mild cognitive impairment, and healthy controls. The three dimensions of the AI (emotional blunting, lack of initiative, and lack of interest) were compared with the Apathy domain of the Neuropsychiatric Inventory-Clinician rating scale (NPI-C) in an independent scheme. Results The analyses demonstrated high correlation coefficients in AI's individual dimensions and in AI-total score (F = 0.965). Concerning the NPI-C/Apathy domain, intra-class correlation coefficients were also high (F = 0.977). Concurrent validity was high according to both raters on AI dimensions × NPI-C/Apathy domain and regarding total score (rater 1: rho = 0.956 vs. rater 2: rho = 0.970). The internal consistency of the AI was also high concerning the AI's individual dimensions and total score (rater 1: 0.945 vs. rater 2: 0.958). Conclusion We observed high internal consistency, high concurrent validity, and inter-rater reliability of the Apathy Inventory. In addition, we found that its sensitivity and specificity were high. We suggest that the Brazilian version of the Apathy Inventory would be an appropriate instrument to identify the apathy syndrome in Brazilian patients. © 2012 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to optimize an internal control to improve SYBR-Green-based qPCR to amplify/detect the BoHV-5 US9 gene in bovine embryos produced invitro and experimentally exposed to the virus. We designed an SYBR-Green-based binding assay that is quick to perform, reliable, easily optimized and compares well with the published assay. Herein we demonstrated its general applicability to detect BoHV-5 US9 gene in bovine embryos produced invitro experimentally exposed to BoHV-5. In order to validate the assay, three different reference genes were tested; and the histone 2a gene was shown to be the most adequate for normalizing the qPCR reaction, by considering melting and standard curves ( p<0.05). On the other hand, no differences were found in the development of bovine embryos invitro whether they were exposed to BoHV-5 reference and field strains comparing to unexposed embryos. The developed qPCR assay may have important field applications as it provides an accurate BoHV-5 US9 gene detection using a proven reference gene and is considerably less expensive than the TaqMan qPCR currently employed in sanitary programs. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Besides optimizing classifier predictive performance and addressing the curse of the dimensionality problem, feature selection techniques support a classification model as simple as possible. In this paper, we present a wrapper feature selection approach based on Bat Algorithm (BA) and Optimum-Path Forest (OPF), in which we model the problem of feature selection as an binary-based optimization technique, guided by BA using the OPF accuracy over a validating set as the fitness function to be maximized. Moreover, we present a methodology to better estimate the quality of the reduced feature set. Experiments conducted over six public datasets demonstrated that the proposed approach provides statistically significant more compact sets and, in some cases, it can indeed improve the classification effectiveness. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to validate the lactate minimum test as a specific aerobic evaluation protocol for table tennis players. Using the frequency of 72 balls·min-1 for 90 sec, an exercise-induced metabolic acidosis was determined in 8 male table tennis players. The evaluation protocol began with a frequency of 40 balls·min-1 followed by an increase of 8 balls·min-1 every 3 min until exhaustion. The mean values that corresponded to the subjects' lactate minimum (Lacmin) were equal to 53.1 ± 1.5 balls·min-1 [adjusted for the time test (Lacmin_time)] and 51.6 ± 1.6 balls·min-1 [adjusted for the frequency of balls (Lacmin_Freq)], which resulted in a high correlation between the two forms of adjustment (r = 0.96 and (P = 0.01). The mean maximum lactate steady state (MLSS) was 52.6 ± 1.6 balls·min-1. Pearson's correlations between Lacmin_time vs. MLSS and Lacmin_freq vs. MLSS were statistically significant (P = 0.03 and r = 0.86, P = 0.03 and r = 0.85, respectively). These findings indicate that the Lacmin test predicts MLSS. Therefore, it is an excellent method to obtain the athletes' anaerobic threshold. Also, there is the advantage that it can be performed in 1 day in the game area. However, the Lacmin value does not depend on the Lacpeak value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo:Este estudo teve como objetivo construir e validar um instrumento de avaliação da compreensão de leitura a fim de caracterizar o perfil de leitura e detectar dificuldades de compreensão em escolares do terceiro ao quinto ano do Ensino Fundamental.Métodos:Participaram 378 escolares divididos em trés grupos para avaliação da compreensão de proposições literais e inferenciais de micro e macroestruturas de dois textos expositivos e dois textos narrativos por meio de questões de múltipla escolha.Resultados:Os dados analisados estatisticamente indicaram valores do teste alfa de Cronbach apresentando consisténcia interna nos quatros textos aplicados para os trés grupos.Conclusão:Foi possível constatar que os escolares apresentaram menor número de erros com o aumento da escolarização e que cada tipo de texto apresentou uma dificuldade específica para os escolares.