958 resultados para Tube wells


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Nutrition therapy (NT) is essential for the care of critically ill children. Inadequate feeding leads to malnutrition and may increase the patient`s risk of morbidity and mortality. The aim of this study was to describe the NT used in a tertiary pediatric intensive care unit (PICU). Methods: The authors evaluated NT administered to 90 consecutive patients who were hospitalized for 7 days in the PICU of Instituto da Crianca, Hospital das Clinicas, Universidade de Sao Paulo, Brazil. NT was established according to the protocol provided by the institution`s NT team. NT provided a balance of fluids and nutrients and was monitored with a weekly anthropometric nutrition assessment and an evaluation of complications. Results: NT was initiated, on average, within 72 hours of hospitalization. Most children (80%) received enteral nutrition (EN) therapy; of these, 35% were fed orally and the rest via nasogastric or postpyloric tube. There were gastrointestinal complications in patients (5%) who needed a postpyloric tube. Parenteral nutrition (PN) was used in only 10% of the cases, and the remaining 10% received mixed NT (EN + PN). The average calorie and protein intake was 82 kcal/kg and 2.7 g/kg per day. Arm circumference and triceps skinfold thickness decreased. Conclusions: The use of EN was prevalent in the tertiary PICU, and few clinical complications occurred. There was no statistically significant change in most anthropometric indicators evaluated during hospitalization, which suggests that NT probably helped patients maintain their nutrition status. (JPEN J Parenter Enteral Nutr. 2011;35:523-529)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The morphological characteristics of the oviduct of 12 sexually mature rheas (Rhea americana) were studied. Only the left oviduct is developed as a long tube with a length of 122 +/- 23.1 cm, and is subdivided into infundibulum (15.2 +/- 4.0 cm), magnum (63.3 +/- 9.4 cm), isthmus (5.6 +/- 3.1 cm), uterus (16.0 +/- 4.2 cm) and vagina (11.5 +/- 1.4 cm). The mucous membrane of the oviduct, as a whole, possesses luminal folds covered by ciliated columnar epithelium with secretory cells. The infundibulum part presents a cranial opening with thin and long fimbriae with few tubular glands in caudal tubular portion. In the magnum, the largest portion of the oviduct, the folds are thicker and are filled with tubular glands. The isthmus is short and presents less bulky folds and a few tubular glands. A bag-shaped uterus in the cranial area shows thin folds, and in the caudal region (shell gland) more ramified folds with few tubular glands. The vagina has long luminal folds and a thick muscular tunic; no glands with sperm-storage characteristics have been observed. In conclusion, the oviduct in sexually mature rhea has morphological similarities with the other species of birds already described; however it presents its own characteristics to produce a big egg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The emergence of periodontal medicine increased interest in defining the behaviour of peripheral blood cells in periodontitis subjects in comparison with healthy group. The aim of this study was to evaluate the levels of interleukin (IL)-8, tumour necrosis factor-alpha (TNF-alpha), IL-6 and IL-10 released by Escherichia coli lipopolysaccharide (LPS)-stimulated peripheral blood mononuclear cells (PBMC) obtained from the peripheral blood of chronic periodontitis subjects. Design: PBMC samples were isolated from 19 systemically healthy donors, divided into generalized chronic periodontitis (n = 10) and healthy (n = 9) subjects. Cells were incubated for 24-48 h in 500 mu L wells containing RPM! 1640 and stimulated with 1.0 ng/mL of E. coli LPS. Supernatants were used to quantify the amounts of IL-8, TNF-alpha, IL-6 and IL-10 released using enzyme-linked immunosorbent assay (ELISA). Results: PBMC cells from periodontitis subjects released higher levels of TNF-alpha and IL-6 than those from healthy subjects (P < 0.05). Conversely, the supernatants of the stimulated PBMC cells obtained from healthy subjects presented higher amounts of IL-8 than those from periodontitis (P < 0.05). No differences were observed in the levels of IL-10 (P > 0.05) between groups. Conclusion: In conclusion, the results of the present study showed that E. coli LPS-stimulated PBMC from subjects with periodontitis present a different pattern of cytokine release when compared to PBMC from healthy subjects. This phenomenon could have implications locally, in periodontitis, as well as in systemic diseases. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: To evaluate calcium ion release and pH of Sealer 26 (S26) (Dentsply, Rio de Janeiro, RJ, Brazil), white mineral trioxide aggregate (MTA), Endo CPM Sealer (CPM1) (EGEO SRL Bajo licencia MTM Argentina SA, Buenos Aires, Argentina), Endo CPM Sealer in a thicker consistency (CPM 2), and zinc oxide and eugenol cement (ZOE). Methods: Material samples (n = 10) were placed in polyethylene tubes and immersed in 10 mL of distilled water. After 3, 6,12,24, and 48 hours and 7,14, and 28 days, the water pH was determined with a pH meter, and calcium release was assessed by atomic absorption spectrophotometry. An empty tube was used as the control group. Results: The control group presented a pH value of 6.9 at all studied periods and did not show the presence of calcium ion. S26 presented greater hydroxyl ion release up to 12 hours (p < 0.05). From 24 hours until 28 days, S26, MTA, CPM1, and CPM2 had similar results. in ail periods, ZOE presented the lowest hydroxyl ion release. CPM1, followed by CPM2, released the most calcium ions until 24 hours (p < 0.05). Between 48 hours and 7 days, CPM1 and CPM2 had the highest release. A greater calcium ion release was observed for CPM2, followed by CPM1 at 14 days and for S26, CPM1, and CPM2 at 28 days. ZOE released the least calcium ions in all periods. Conclusion: Sealer 26, MTA, and Endo CPM sealer at normal or thicker consistency release hydroxyl and calcium ions. Endo CPM sealer may be an alternative as root-end filling material. (J Endod 2009;35:1418-1421)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Fibroblasts are considered important cells in periodontitis. When challenged by different agents, they respond through the release of cytokines that participate in the inflammatory process. The aim of this study is to evaluate and compare the expression and production of macrophage inflammatory protein (MIP)-1 alpha, stromal-derived factor (SDF)-1, and interleukin (IL)-6 by human cultured periodontal ligament and gingival fibroblasts challenged with lipopolysaccharide (LPS) from Porphyromonas gingivalis. Methods: Fibroblasts were cultured from biopsies of gingival tissue and periodontal ligament of the same donors and used on the fourth passage. After confluence in 24-well plates, the culture medium alone (control) or with 0.1 to 10 mu g/ml of LPS from P. gingivalis was added to the wells, and after 1, 6, and 24 hours, the supernatant and the cells were collected and analyzed by enzyme-linked immunosorbent assay and real-time polymerase chain reaction, respectively. Results: MIP-1 alpha, SDF-1, and IL-6 protein production was significantly greater in gingival fibroblasts compared to periodontal ligament fibroblasts. IL-6 was upregulated in a time-dependent manner, mainly in gingival fibroblasts (P<0.05), which secreted more MIP-1 alpha in the lowest concentration of LPS used (0.1 mu g/ml). In contrast, a basal production of SDF-1 that was inhibited with the increase of LPS concentration was detected, especially after 24 hours (P<0.05). Conclusion: The distinct ability of the gingival and periodontal ligament fibroblasts to secrete MIP-1 alpha, SDF-1, and IL-6 emphasizes that these cells may differently contribute to the balance of cytokines in the LPS-challenged periodontium. J Periodontol 2010;81:310-317.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the antibacterial effect of different chlorhexidine (CHX) concentrations against Streptococcus mutans using the agar-diffusion method with and without human dentin discs placed between the bacteria and the test substances. Methods: For the direct application (agar-well technique), a base layer containing 15 mL of BHI agar and 300 mu L. of S. mutans inoculum (10(9) cfu/mL) was prepared in Petri dishes. Six wells per dish were made at equidistant points and immediately filled with CHX gels (0.12%, 0.2%, 1% and 2%), 35% phosphoric acid and pure natrosol (n=6 wells/substance). Paper discs soaked in sterile distilled water served as control group (n=6). For the indirect application (transdentinal diffusion), 0.2 mm- and 0.5 mm-thick human dentin discs (36 discs/thickness) had the hydraulic conductance determined, which allowed the homogeneous allocation of them to the experimental and control groups. The discs were placed at equidistant points on the Petri dishes containing BHI with the S. mutans inoculum (six discs per dish; one per substance) with the pulpal side in contact with the bacteria. In the discs treated with CHX gels, dentin surface was etched with H(3)PO(4) and rinsed with distilled water before CHX gel application for 1 minute. After both direct and indirect application, the dishes were incubated for 24 hours and the bacterial growth inhibition zones formed around the wells and dentin discs were measured. Data were analyzed statistically by the non-parametric Kruskal-Wallis and Mann-Whitney tests at 5% significance level. Results: In the direct test, all CHX concentrations presented a dose-dependent antibacterial activity against S. mutans. In the indirect test, there were statistically significant differences (P< 0.05) among all groups and the largest microbial growth inhibition zones were observed when 2% CHX was applied on 0.2 mm-thick discs (P< 0.05). It was concluded that all evaluated CHX gels exhibited both direct and transdentinal antibacterial activity against S. mutans. This effect of CHX was strongly influenced by the CHX concentration as well as the dentin barrier thickness. (Am J Dent 2010;23:255-259).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This study examined the retention of solvents within experimental HEMA/solvent primers after two conditions for solvent evaporation: from a free surface or from dentine surface. Methods: Experimental primers were prepared by mixing 35% HEMA with 65% water, methanol, ethanol or acetone (v/v). Aliquots of each primer (50 mu l) were placed on glass wells or they were applied to the surface of acid-etched dentine cubes (2 mm x 2 mm x 2 mm) (n = 5). For both conditions (i.e. from free surface or dentine cubes), change in primers mass due to solvent evaporation was gravimetrically measured for 10 min at 51% RH and 21 degrees C. The rate of solvent evaporation was calculated as a function of loss of primers mass (%) over time. Data were analysed by two-way ANOVA and Student-Newman-Keuls (p < 0.05). Results: There were significant differences between solvent retention(%) and evaporation rate (%/min) depending on the solvent present in the primer and the condition for evaporation (from free surface or dentine cubes) (p < 0.05). For both conditions, the greatest amount of retained solvent was observed for HEMA/water primer. The rate of solvent evaporation for HEMA/acetone primer was almost 2- to 10-times higher than for HEMA/water primer depending whether evaporation occurred, respectively, from a free surface or dentine cubes. The rate of solvent evaporation varied with time, being in general highest at the earliest periods. Conclusions: The rate of solvent evaporation and its retention into HEMA/solvent primers was influenced by the type of the solvent and condition allowed for their evaporation. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The objective of this study was to evaluate the sealing ability of AH Plus, Epiphany, Acroseal, Endofill, and Polifil after active lateral condensation technique, by using a bacterial test, during 64 days. Study design. One hundred bovine incisors were cleaned and shaped; then they were filled with the endodontic sealers and adapted into a microcentrifuge tube. The setup root/microcentrifuge tube was added to glass flasks containing Brain Heart Infusion broth. A culture of Enterococcus faecalis was inserted into the upper chamber of each assembly. Daily leakage was evaluated through the broth turbidity. Results. The results were submitted to statistical analysis (Kaplan-Meier method, Kruskal-Wallis and Dunn tests). Conclusions. AH Plus and Endofill had the worst sealing ability when compared with Polifil, which showed the least leakage. Acroseal and Epiphany showed a tendency toward having an intermediate behavior; however, there was no significant difference among Acroseal, Epiphany, and the other sealers. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e56-e60)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The purpose of this study was to evaluate the biocompatibility of the root canal filling system Epiphany/Resilon in connective tissue of rats. Methods: Fifteen rats were used, separated into 3 groups in accordance with its period of death (7, 21, 42 days). Four filled dentin tubes were implanted with the tested materials as follows: ERSP group, Epiphany/Resilon with Self-etch Primer; ER group, Epiphany/Resilon without primer; EG group, Endofill/gutta-percha points; and ET group, empty tube. After 7, 21, and 42 days, animals were killed, obtaining 5 samples per group. A grade from I-IV was used to graduate the inflammatory reaction. Results: Results showed that Epiphany/Resilon (ERSP and ER groups) induced a slight (II) inflammatory reaction after 42 days. However, in ER group, in which the self-etch primer was not applied, severe (IV) to moderate (III) inflammatory reactions were observed between 7 and 21 days. When compared with the EG and ET groups, it was observed that these groups presented tissue reaction ranging from slight (II, 7 and 21 days) to no inflammation (I, 42 days). Conclusions: Epiphany/Resilon root canal filling system presented satisfactory tissue reaction. It was biocompatible when tested in connective tissue of rats. (J Endod 2010;36:110-114)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The architectonic features of the thalamic ventrobasal complex (Vb) of two species of Megachiropteran (Grey-headed flying fox, Pteropus poliocephalus, and the Eastern tube-nosed bat, Nyctimene robinsoni) are compared with those of a Microchiropteran (Australian ghost bat, Macroderma gigas). The somatosensory system was chosen for comparison as it represents a sensory system that has undergone analogous modifications in both Chiropteran lineages (the evolution of the wing). The components of Vb were examined as there are taxon-specific features in this region of the brain. Within the Megachiropteran Vb, four subnuclei were recognized: the ventral posterior medial (VPM), the ventral posterior lateral (VPL), the ventral posterior inferior (VPI), and the basal ventral medial (VMb). In the ghost bat only VPM and VPL were identified with certainty. No VPI was evident in the ghost bat, however a putative VMb was observed. Vb of the ghost bat also lacked the arcuate lamina, which distinguishes VPM from VPL in the Megachiropterans and many other mammals. These taxon-specific differences lend support to the proposal that the order Chiroptera has a diphyletic origin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acanthoplacatus gen. nov., a new genus of viviparous gyrodactylid, is described from the rns and skin of siganid fishes from the Great Barrier Reef, Australia. The genus is characterized by a muscular, tube-like haptor with 16 marginal hooks on the posterior margin. The ventral lobe of the haptor is located anteriorly relative to the dorsal lobe and contains a pair of hamuli and a ventral bar with posteriorly-projecting ventral bar membrane. A dorsal bar is absent. Five pairs of posterior gland cells surround the posterior terminations of the gut. The male copulatory organ is a muscular, non-eversible bulb with several spines around the distal opening. Species of Acanthoplacatus have a bilateral excretory system consisting of six pairs of flame cells and a pair of excretory bladders. Seven new species are described: Acanthoplacatus adlardi sp. nov. and A. amplihamus sp. nov. from Siganus punctatus (Forster, 1801), A. brauni sp. nov. from S. corallinus (Valenciennes, 1835), A. parvihamus sp. nov. from S. vulpinus (Schlegel and Mueller, 1845), A. puelli sp. nov. from S. puellus Schlegel, 1852, A. shieldsi sp. nov. from S. lineatus (Valenciennes, 1835) and A. sigani sp. nov. from S. fuscescens (Houttuyn, 1782). Species can be discriminated by shape and size of the hamuli, marginal hooks and ventral bar and by male copulatory organ sclerite morphology. Three species (A. brauni sp. nov., A. shieldsi sp. nov. and A. sigani sp. nov.) were assessed for seasonal variation of sclerite size. Ten of thirteen morphological characters showed seasonal variation in size for at least one of the species. The characters were longer in winter except dorsal root tissue cap width. Only one character, marginal hook length, showed significant seasonal variation for all three species. Species of Acanthoplacatus were observed to attach using only the marginal hooks and the role of hamuli in attachment is unclear. The dorsal rn of the host is the preferred site for most species but the anal fin, caudal fin and body surfaces are preferred by some species. Prevalences for species range from 57 to 100%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modelling and simulation studies were carried out at 26 cement clinker grinding circuits including tube mills, air separators and high pressure grinding rolls in 8 plants. The results reported earlier have shown that tube mills can be modelled as several mills in series, and the internal partition in tube mills can be modelled as a screen which must retain coarse particles in the first compartment but not impede the flow of drying air. In this work the modelling has been extended to show that the Tromp curve which describes separator (classifier) performance can be modelled in terms of d(50)(corr), by-pass, the fish hook, and the sharpness of the curve. Also the high pressure grinding rolls model developed at the Julius Kruttschnitt Mineral Research Centre gives satisfactory predictions using a breakage function derived from impact and compressed bed tests. Simulation studies of a full plant incorporating a tube mill, HPGR and separators showed that the models could successfully predict the performance of the another mill working under different conditions. The simulation capability can therefore be used for process optimization and design. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Near-Resonant Holographic Interferometry is a powerful technique which extends the established advantages of conventional holographic interferometry by allowing a species-specific number density to be determined. It has been tested in the harsh flow conditions generated in a high enthalpy facility yielding information about the shock shape on a cylindrical body and on the distribution of a trace species seeded into the flow.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Expansion tubes operating at total flow enthalpies of 100 MJ kg(-1) or more have characteristical test times of 30-50 mus. Under these conditions, the response time of the Pitot pressure measuring device is critical when performing flow calibration studies. The conventional technique of using a commercial pressure transducer protected by shielding has not always proven to be effective, due to the relatively large (and variable) response time caused by the shielding. A device called the stress wave bar gauge has been designed and calibrated and shown to be an effective way to measure the Pitot pressure with a response time of only 2-3 mus.